Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETOMETERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Significant reduction in the low-field magnetization of Nb 3 Sn superconducting strands using the internal oxidation APC approach

Nb 3 Sn superconductors are promising for building accelerator magnets for future energy-frontier circular colliders. A critical factor for this application is the low-field persistent-current magnetization because it leads to several critical issues: e.g. low-field instability (including flux jumps), hysteresis loss, and field errors in magnet bores. Suppression of low-field magnetization requires reduction of low-field critical current density (J c ) or effective subelement size (d eff ). However, reduction of deff of state-of-the-art Nb 3 Sn conductors—the restacked-rod-process (RRP ® ) type—below 40–50 μm without a pronounced decrease in high-field J c is difficult. On the other hand, the internal oxidation method which forms artificial pinning centers (APC) in Nb 3 Sn offers an alternative approach to reducing the low-field magnetization. Compared with a conventional Nb 3 Sn conductor whose flux pinning force versus field (F p –B) curve peaks at ~20% of its irreversibility field (B irr ), the F p –B curve peaks of APC conductors shift to higher fields due to the point pinning effect, leading to flattening of the J c –B curves. The goal of this paper is to quantitatively study how much the APC approach can reduce the low-field magnetization. Here we measured the J c –B curves of an RRP ® conductor and two APC conductors (reacted at 700 °C) from zero field to B irr using a high-field vibrating sample magnetometer. Here the results showed that the APC conductors have higher non-Cu J c at high fields (e.g. 32%–41% higher at 16 T) and simultaneously lower non-Cu Jc at low fields (e.g. 28%–34% lower at 1 T) compared with the RRP ® . This effect is due to a competition between their Nb3Sn layer fraction ratios and layer F p ratios. Suppose they reach the same 16 T non-Cu J c , then the 1 T non-Cu J c and magnetization of the APC conductors are only half or even less compared with the RRP ® conductor.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Single-trial classification of evoked responses to auditory tones using OPM- and SQUID-MEG

Abstract Objective. Optically pumped magnetometers (OPMs) are emerging as a near-room-temperature alternative to superconducting quantum interference devices (SQUIDs) for magnetoencephalography (MEG). In contrast to SQUIDs, OPMs can be placed in a close proximity to subject’s scalp potentially increasing the signal-to-noise ratio and spatial resolution of MEG. However, experimental demonstrations of these suggested benefits are still scarce. Here, to compare a 24-channel OPM-MEG system to a commercial whole-head SQUID system in a data-driven way, we quantified their performance in classifying single-trial evoked responses. Approach. We measured evoked responses to three auditory tones in six participants using both OPM- and SQUID-MEG systems. We performed pairwise temporal classification of the single-trial responses with linear discriminant analysis as well as multiclass classification with both EEGNet convolutional neural network and xDAWN decoding. Main results. OPMs provided higher classification accuracies than SQUIDs having a similar coverage of the left hemisphere of the participant. However, the SQUID sensors covering the whole helmet had classification scores larger than those of OPMs for two of the tone pairs, demonstrating the benefits of a whole-head measurement. Significance. The results demonstrate that the current OPM-MEG system provides high-quality data about the brain with room for improvement for high bandwidth non-invasive brain–computer interfacing.

Iivanainen, Joonas (ORCID:0000000160344604)↗

Transient shocks beyond the heliopause

The heliopause is a rich, dynamic surface affected by the time-dependent solar wind. Stream interactions due to coronal mass ejections (CMEs), corotating interaction regions (CIRs), and other transient phenomena are known to merge producing global merged interaction regions (GMIRs). Numerical simulations of the solar wind interaction with the local interstellar medium (LISM) show that GMIRs, as well other time-dependent structures in the solar wind, may produce compression/rarefaction waves and shocks in the LISM behind the heliopause. These shocks may initiate wave activity observed by the Voyager spacecraft. The magnetometer onboard Voyager 1 indeed observed a few structures that may be interpreted as shocks. We present numerical simulations of such shocks in the year of 2000, when both Voyager spacecraft were in the supersonic solar wind region, and in 2012, when Voyager 1 observed traveling shocks. In the former case, Voyager observations themselves provide time- dependent boundary conditions in the solar wind. In the latter case, we use OMNI data at 1 AU to analyze the plasma and magnetic field behavior after Voyager 1 crossed the heliospheric boundary. Numerical results are compared with spacecraft observations.

79 ASTRONOMY AND ASTROPHYSICS↗

A new cryogenic apparatus to search for the neutron electric dipole moment

A cryogenic apparatus is described that enables a new experiment, nEDM@SNS, with a major improvement in sensitivity compared to the existing limit in the search for a neutron Electric Dipole Moment (EDM). This apparatus uses superfluid 4 He to produce a high density of Ultra-Cold Neutrons (UCN) which are contained in a suitably coated pair of measurement cells. The experiment, to be operated at the Spallation Neutron Source at Oak Ridge National Laboratory, uses polarized 3 He from an Atomic Beam Source injected into the superfluid 4 He and transported to the measurement cells where it serves as a co-magnetometer. The superfluid 4 He is also used as an insulating medium allowing significantly higher electric fields, compared to previous experiments, to be maintained across the measurement cells. Finally, these features provide an ultimate statistical uncertainty for the EDM of 2-3× 10 -28 e-cm, with anticipated systematic uncertainties below this level.

47 OTHER INSTRUMENTATION↗

Engineering diamond interfaces free of dark spins

Nitrogen-vacancy (NV) centers in diamond are utilized extensively as quantum sensors for imaging fields at the nanoscale. The ultrahigh sensitivity of NV magnetometers has enabled the detection and spectroscopy of individual electron spins, with potentially far-reaching applications in condensed matter physics, spintronics, and molecular biology. However, the surfaces of these diamond sensors naturally contain electron spins, which create a background signal that can be hard to differentiate from the signal of the target spins. In this study, we develop a surface modification approach that eliminates the unwanted signal of these so-called dark electron spins. Our surface passivation technique, based on coating diamond surfaces with a thin titanium oxide (Ti⁢O 2 ) layer, reduces the dark spin density. The observed reduction in dark spin density aligns with our findings on the electronic structure of the diamond-Ti⁢O 2 interface. The reduction, from a typical value of 2000 μm −2 to a value below that set by the detection limit of our NV sensors (200 μm −2 ), results in a twofold increase in Hahn-echo coherence time of near surface NV centers. Furthermore, we derive a comprehensive spin model that connects dark spin relaxation with NV coherence, providing additional insights into the mechanisms behind the observed spin dynamics. Our findings are directly transferable to other quantum platforms, including nanoscale solid-state qubits and superconducting qubits.

74 ATOMIC AND MOLECULAR PHYSICS↗

Backaction-evading impulse measurement with mechanical quantum sensors

The quantum measurement of any observable naturally leads to noise added by the act of measurement. Approaches to evade or reduce this noise can lead to substantial improvements in a wide variety of sensors, from laser interferometers to precision magnetometers and more. In this paper, we develop a measurement protocol based upon pioneering work by the gravitational wave community which allows for reduction of added noise from measurement by coupling an optical field to the momentum of a small mirror. As a specific implementation, we present a continuous measurement protocol using a double-ring optomechanical cavity. We demonstrate that, with experimentally relevant parameters, this protocol can lead to significant backaction noise evasion, yielding measurement noise below the standard quantum limit over many decades of frequency.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Variational quantum state preparation for quantum-enhanced metrology in noisy systems

Here, we investigate optimized quantum state preparation for quantum metrology applications in noisy environments. Using the QFI-OPT package, we simulate a low-depth variational quantum circuit (VQC) composed of a sequence of global rotations and entangling operations applied to a chain of qubits that are subject to dephasing noise. The parameters controlling the VQC are numerically optimized to maximize the quantum Fisher information, which characterizes the ultimate metrological sensitivity of a quantum state with respect to a global rotation. We find that, regardless of the details of the entangling operation implemented in the VQC, the optimal quantum states can be broadly classified into a trio of qualitative regimes, i.e., catlike, squeezed like, and product states, associated with different dephasing rates. Our findings are relevant for designing optimal state-preparation strategies for next-generation quantum sensors exploiting entanglement, such as time and frequency standards and magnetometers, aimed at achieving state-of-the-art performance in the presence of noise and decoherence.

quantum Fisher information↗

High-Field Magnetoresistance of Organic Semiconductors

The magnetoelectronic field effects in organic semiconductors at high magnetic fields are described by field-dependent mixing between singlet and triplet states of weakly bound charge-carrier pairs due to small differences in their Landé g factors that arise from the weak spin-orbit coupling in the material. In this work, we corroborate theoretical models for the high-field magnetoresistance of organic semiconductors, in particular of diodes made of the conducting polymer poly(3,4-ethylenedioxythiophene):poly(styrene-sulfonate) (PEDOT:PSS) at low temperatures, by conducting magnetoresistance measurements along with multifrequency continuous-wave electrically detected magnetic-resonance experiments. The measurements are performed on identical devices under similar conditions in order to independently assess the magnetic-field-dependent spin-mixing mechanism, the so-called Δg mechanism. Finally, an understanding of the microscopic origin of magnetoresistance in organic semiconductors is crucial for developing reliable magnetometer devices capable of operating over a broad range of magnetic fields of order 10 -7 - 10 T.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multifunctional Superconducting Nanowire Quantum Sensors

Superconducting nanowire single-photon detectors (SNSPDs) offer high-quantum-efficiency and low-dark-count-rate single-photon detection. In a growing number of cases, large magnetic fields are being incorporated into quantum microscopes, nanophotonic devices, and sensors for nuclear and high-energy physics that rely on SNSPDs, but superconducting devices generally perform poorly in large magnetic fields. Here, we demonstrate robust performance of amorphous SNSPDs in magnetic fields of up to ±6 T with a negligible dark-count rate and unchanged quantum efficiency at typical bias currents. Critically, we also show that the SNSPD can be used as a magnetometer with a sensitivity of better than 100μT/√Hz and as a thermometer with a sensitivity of 20μK/√Hz at 1 K. Thus, a single-photon detector integrated into a quantum device can be used as a multifunctional quantum sensor capable of describing the temperature and magnetic field on chip simply by varying the bias current to change the operating modality from single-photon detection to thermometry or magnetometry.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fermi-surface topologies and low-temperature phases of the filled skutterudite compounds CeOs 4 Sb 12 and NdOs 4 Sb 12

We use MHz conductivity, torque magnetometer, and magnetization measurements to report on single crystals of CeOs 4 Sb 12 and NdOs 4 Sb 12 using temperatures down to 0.5 K and magnetic fields of up to 60 tesla. The field-orientation dependence of the de Haas-van Alphen and Shubnikov-de Haas oscillations is deduced by rotating the samples about the [ 010 ] and [ 0 $\bar{1}$ 1 1 ] directions. Our results indicate that NdOs 4 Sb 12 has a similar Fermi surface topology to that of the unusual superconductor PrOs 4 Sb 12 , but with significantly smaller effective masses, supporting the importance of local phonon modes in contributing to the low-temperature heat capacity of NdOs 4 Sb 12 . By contrast, CeOs 4 Sb 12 undergoes a field-induced transition from an unusual semimetal into a high-field, high-temperature state characterized by a single, almost spherical Fermi-surface section. Furthermore, the behavior of the phase boundary and comparisons with models of the band structure lead us to propose that the field-induced phase transition in CeOs 4 Sb 12 is similar in origin to the well-known α - γ transition in Ce and its alloys.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Earth as a transducer for dark-photon dark-matter detection

We propose the use of the Earth as a transducer for ultralight dark-matter detection. In particular, we point out a novel signal of kinetically mixed dark-photon dark matter: a monochromatic oscillating magnetic field generated at the surface of the Earth. Similar to the signal in a laboratory experiment in a shielded box (or cavity), this signal arises because the lower atmosphere is a low-conductivity air gap sandwiched between the highly conductive interior of the Earth below and ionosphere or interplanetary medium above. At low masses (frequencies) the signal in a laboratory detector is usually suppressed by the size of the detector multiplied by the dark-matter mass. Crucially, in our case the suppression is by the radius of the Earth, and not by the (much smaller) height of the atmosphere. We compute the size and global vectorial pattern of our magnetic field signal, which enables sensitive searches for this signal using unshielded magnetometers dispersed over the surface of the Earth. In principle, the signal we compute exists for any dark photon in the mass range 10 –21 eV ≲ m A' ≲ 3 × 10 –14 eV . We summarize the results of our companion paper [M. A. Fedderke et al., Search for dark-photon dark matter in the SuperMAG geomagnetic field dataset, arXiv:2108.08852], in which we detail such a search using a publicly available dataset from the SuperMAG Collaboration: we report no robust signal candidates and so place constraints in the (more limited) dark-photon dark-matter mass range 2 × 10 –18 eV ≲ m A' ≲ 7 × 10 –17 eV (corresponding to frequencies 6 × 10 –4 Hz ≲ f ≲ 2 × 10 –2 Hz). These constraints are complementary to existing astrophysical bounds. Future searches for this signal may improve the sensitivity over a wide range of ultralight dark-matter candidates and masses.

79 ASTRONOMY AND ASTROPHYSICS↗

Sensitivity of ultralight axion dark matter search with optical quantum sensors

An optical quantum sensor (OQS) based on lasers and alkali-metal atoms is a sensitive ambient-temperature magnetometer that can be used in axion dark matter search with an inductor-capacitor (LC) circuit at kHz and MHz frequencies. We have previously investigated the sensitivity of an LC circuit-OQS axion detector to ultralight axion dark matter that could be achieved using a fT-noise OQS constructed in our lab. In this paper, we investigate the sensitivity that could be potentially reached by an OQS performing close to the fundamental quantum noise levels of 10 aT / $\sqrt{Hz}$. To take advantage of the quantum-limited OQS, the LC circuit has to be made of a superconductor and cooled to low temperature of a few K. After considering the intrinsic noise of the advanced axion detector and characterizing possible background noises, we estimate that such an experiment could probe benchmark QCD axion models in an unexplored mass range near 10 neV. Reaching such a high sensitivity is a difficult task, so we have conducted some preliminary experiments with a large-bore magnet and a prototype axion detector consisting of a room-temperature LC circuit and a commercial OQS unit. In conclusion, this paper describes the prototype experiment and its projected sensitivity to axions in detail.

79 ASTRONOMY AND ASTROPHYSICS↗

Ultralight dark matter detection with levitated ferromagnets

Levitated ferromagnets act as ultraprecise magnetometers, which can exhibit high quality factors due to their excellent isolation from the environment. These instruments can be utilized in searches for ultralight dark matter candidates, such as axionlike dark matter or dark-photon dark matter. In addition to being sensitive to an axion-photon coupling or kinetic mixing, which produce physical magnetic fields, ferromagnets are also sensitive to the effective magnetic field (or “axion wind”) produced by an axion-electron coupling. While the dynamics of a levitated ferromagnet in response to a dc magnetic field have been well studied, all of these couplings would produce ac fields. In this work, we study the response of a ferromagnet to an applied ac magnetic field and use these results to project their sensitivity to axion and dark-photon dark matter. We pay special attention to the direction of motion induced by an applied ac field, in particular, whether it precesses around the applied field (similar to an electron spin) or librates in the plane of the field (similar to a compass needle). We show that existing levitated ferromagnet setups can already have comparable sensitivity to an axion-electron coupling as comagnetometer or torsion balance experiments. In addition, future setups can become sensitive probes of axion-electron coupling, dark-photon kinetic mixing, and axion-photon coupling, for ultralight dark matter masses m DM ≲ feV . Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for ultralight dark matter in the SuperMAG high-fidelity dataset

Ultralight dark matter, such as kinetically mixed dark-photon dark matter (DPDM) or axion-like-particle dark matter (axion DM), can source an oscillating magnetic-field signal at Earth’s surface. Previous work searched for this signal in a publicly available dataset of global magnetometer measurements maintained by the SuperMAG collaboration. This “low-fidelity” dataset reported measurements with a 1-min time resolution, allowing the search to set leading direct constraints on DPDM and axion DM with Compton frequencies f DM ≤ 1 / ( 1 min ) (corresponding to masses m DM ≤ 7 × 10 − 17 eV ). More recently, a dedicated experiment undertaken by the SNIPE Hunt collaboration has also searched for this same signal at higher frequencies f DM ≥ 0.5 Hz (or m DM ≥ 2 × 10 − 15 eV ). In this work, we search for this signal of ultralight DM in the SuperMAG “high-fidelity” dataset, which features a 1-sec time resolution, allowing us to probe the gap in parameter space between the low-fidelity dataset and the SNIPE Hunt experiment. The high-fidelity dataset exhibits lower geomagnetic noise than the low-fidelity dataset and features more data than the SNIPE Hunt experiment, making it a powerful probe of ultralight DM. Our search finds no robust DPDM or axion DM candidates. We set constraints on DPDM and axion DM parameter space for 10 − 3 Hz ≤ f DM ≤ 0.98 Hz (or 4 × 10 − 18 eV ≤ m DM ≤ 4 × 10 − 15 eV ). Our results are the leading direct constraints on both DPDM and axion DM in this mass range, and our DPDM constraint surpasses the leading astrophysical constraint in a narrow range around m A ′ ≈ 2 × 10 − 15 eV . Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Proposal for Axion Dark Matter Detection Using an L C Circuit

Here, we show that dark matter axions cause an oscillating electric current to flow along magnetic field lines. The oscillating current induced in a strong magnetic field B → 0 produces a small magnetic field B → a . We propose to amplify and detect B → a using a cooled LC circuit and a very sensitive magnetometer. This appears to be a suitable approach to searching for axion dark matter in the 10 –7 to 10 –9 eV mass range.

79 ASTRONOMY AND ASTROPHYSICS↗

New Limit on the Permanent Electric Dipole Moment of 129 Xe Using 3 He Comagnetometry and SQUID Detection

We report results of a new technique to measure the electric dipole moment of 129 Xe with 3 He comagnetometry. In this work, both species are polarized using spin-exchange optical pumping, transferred to a measurement cell, and transported into a magnetically shielded room, where SQUID magnetometers detect free precession in applied electric and magnetic fields. The result from a one week measurement campaign in 2017 and a 2.5 week campaign in 2018, combined with detailed study of systematic effects, is d A ( 129 Xe) = 1.4 ± 6.6 stat ± 2.0 syst ) × 10 –28 e cm. This corresponds to an upper limit of |d A ( 129 Xe)| < 1.4 × 10 –27 e cm (95% C.L.), a factor of 5 more sensitive than the limit set in 2001.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Exploiting Spin Fluctuations for Enhanced Pure Spin Current

We demonstrate the interplay of pure spin current, spin-polarized current, and spin fluctuation in 3d Ni x Cu 1–x . By tuning the compositions of the Ni x Cu 1–x alloys, we separate the effects due to the pure spin current and spin-polarized current. By exploiting the interaction of spin current with spin fluctuation in suitable Ni-Cu alloys, we obtain an unprecedentedly high spin Hall angle of 46%, about 5 times larger than that in Pt, at room temperature. Furthermore, we show that spin-dependent thermal transport via anomalous Nernst effect can serve as a sensitive magnetometer to electrically probe the magnetic phase transitions in thin films with in-plane anisotropy. As a result, the enhancement of spin Hall angle by exploiting spin current fluctuation via composition control makes 3d magnets functional materials in charge-to-spin conversion for spintronic application.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Rolling Root Mean Square Based Multimodal Anomaly Detection for Real Time Monitoring of Smart Grid

Reliable real-time monitoring is valuable for maintaining the operational integrity of modern electrical smart grids. Deployment of heterogeneous sensing technologies in substations has enabled high-resolution, multichannel waveform monitoring, but also introduces challenges for anomaly detection due to noise, baseline drift, and modality-dependent signal characteristics. In this work, we present a computationally efficient unsupervised method for multimodal event detection based on Rolling Root Mean Square based Event Detection (RRMSED). The method is developed using in-house, field deployed sensors collecting data at a utility substation. The sensing system comprises voltage and current sensors, triaxial accelerometers, and magnetometers, collectively capturing electrical, vibrational, and magnetic waveform measurements at high temporal resolution. RRMSED operates by extracting rolling RMS energy features and their first-order temporal differences from consecutive waveform segments for each channel and then applying channel-specific statistical thresholds learned from historical data. A persistence-based exceedance logic is employed to robustly identify transient events while suppressing impulsive noise, and to provide precise temporal localization with high resolution. The framework is designed for continuous server-side operation and can be deployed in real time without requiring complex models. Experiments on simulated waveform data with known ground truth demonstrate low false positive (FP) and false negative (FN) rates. Application to real substation data shows RRMSED to identify events that are not captured by conventional monitoring indicators including fast transient detection algorithm currently deployed in the system. These results indicate that rolling RMS based features provide an effective and practical basis for real-time multimodal event detection in smart-grid substations.

Mukherjee, Subrata [ORNL] (ORCID:0000000309930338)↗