Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Patterns of Retropharyngeal Node Metastasis in Nasopharyngeal Carcinoma

Purpose: To explore the pattern of metastasis to retropharyngeal lymph nodes (RLN) and its relationship with tumor range in nasopharyngeal carcinoma (NPC) patients by using magnetic resonance imaging. Methods and Materials: Magnetic resonance images of 618 NPC patients were reviewed. Nodes were classified as metastatic on the basis of size criteria, the presence of nodal necrosis, and extracapsular spread. Results: A total of 597 involved RLN were detected in 392 patients (63.4%). The sites of RLN metastasis included occipital bone, 37 (6.2%); first cervical vertebra (C1), 453 (75.9%); second cervical vertebra (C2), 104 (17.4%); and third cervical vertebra (C3), 3 (0.5%). The incidence of RLN involvement was less than that of Level IIb node involvement (72.2% vs. 86.5%) in 543 patients with lymphadenopathy. The incidence of RLN metastasis was significantly higher in cases of parapharyngeal space invasion or involvement of Level II, Level III, Level IV, and/or Level V nodes and significantly lower in N0 and Stage I disease. Conversely, the incidence of RLN metastasis did not differ significantly among T1, 2, 3, and 4 disease or among Stage II, III, and IV disease. Conclusions: Level IIb nodes, rather than RLN, seem to be the first-echelon nodes in NPC. The incidence of RLN metastasis decreases steadily from level C1 to level C3. Retropharyngeal lymph node metastasis correlates well with involvement of the parapharyngeal space and metastases to Level II, III, IV, and/or V nodes but not with T stage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Switchable wavelength-selective and diffuse metamaterial absorber/emitter with a phase transition spacer layer

We numerically demonstrate a switchable metamaterial absorber/emitter by thermally turning on or off the excitation of magnetic resonance upon the phase transition of vanadium dioxide (VO{sub 2}). Perfect absorption peak exists around the wavelength of 5 μm when the excitation of magnetic resonance is supported with the insulating VO{sub 2} spacer layer. The wavelength-selective absorption is switched off when the magnetic resonance is disabled with metallic VO{sub 2} that shorts the top and bottom metallic structures. The resonance wavelength can be tuned with different geometry, and the switchable metamaterial exhibits diffuse behaviors at oblique angles. The results would facilitate the design of switchable metamaterials for active control in energy and sensing applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Weak Magnetic Field Resonance Effects in Diamond with Nitrogen-Vacancy Centers

The photoluminescence intensity of the ensemble of NV centers in diamond at weak magnetic field was studied. Two resonances were revealed in the region of weak magnetic fields: the first resonance with a width of the order of 20 G, and the second resonance with a width of the order of 180 G. The presence of these optical resonances makes it possible to propose a new concept for creating magnetic field sensors based on a diamond with an ensemble of NV centers without the use of a microwave field.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Decay time characteristics of La2O2S:Eu and La2O2S:Tb for use within an optical sensor for human skin temperature measurement

We focus on the development of a remote temperature sensing technology, i.e., an optical laser-based sensor, using thermographic phosphors for medical applications, particularly within an electromagnetically hostile magnetic resonance imaging (MRI) environment. A MRI scanner uses a strong magnetic field and radio waves to generate images of the inside of the body. The quality of the image improves with increasing magnetic resonance; however, the drawback of applying a greater magnetic strength is the inducement of heat into the body tissue. Therefore, monitoring the patient's temperature inside MRI is vital, but until now, a practical solution for temperature measurement did not exist. We show europium doped lanthanum oxysulphide (La2O2S:Eu) and terbium doped lanthanum oxysulphide (La2O2S:Tb) are both temperature sensitive to a low temperature range of 10-50 deg. C when under ultraviolet (UV) excitation. The emission spectra and decay time characteristics of these phosphors were demonstrated. The results indicate that La2O2S:Eu has a quenching rate of 13.7 m deg. C{sup -1} and 4 m deg. C{sup -1} at 512 nm and 538 nm, respectively. In addition, La2O2S:Tb has a lower quenching rate of 4.19 m deg. C{sup -1} at 548 nm due to its faster decay time.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Method of performing MRI with an atomic magnetometer

A method and apparatus are provided for performing an in-situ magnetic resonance imaging of an object. The method includes the steps of providing an atomic magnetometer, coupling a magnetic field generated by magnetically resonating samples of the object through a flux transformer to the atomic magnetometer and measuring a magnetic resonance of the atomic magnetometer.

47 OTHER INSTRUMENTATION↗

Method of performing MRI with an atomic magnetometer

A method and apparatus are provided for performing an in-situ magnetic resonance imaging of an object. The method includes the steps of providing an atomic magnetometer, coupling a magnetic field generated by magnetically resonating samples of the object through a flux transformer to the atomic magnetometer and measuring a magnetic resonance of the atomic magnetometer.

47 OTHER INSTRUMENTATION↗

Magnesium silicate dissolution investigated by Si-29 MAS, H-1-Si-29 CPMAS, Mg-25 QCPMG NMR.

Olivine-(Mg,Fe){sub 2}SiO{sub 4}-has been the subject of frequent investigation in the earth sciences because of its simple structure and rapid dissolution kinetics. Several studies have observed a preferential release of the divalent cation with respect to silicon during weathering under acidic conditions, which has been correlated to the formation of a silicon-rich leached layer. While leached layer formation has been inferred through the changing solution chemistry, a thorough spectroscopic investigation of olivine reacted under acidic conditions has not been conducted. The pure magnesium end member of the olivine series (forsterite-Mg{sub 2}SiO{sub 4}) was chosen for detailed investigations in this study because paramagnetic iron hinders NMR investigations by providing an extra mode of relaxation for neighboring nuclei, causing lineshapes to become significantly broadened and unobservable in the NMR spectrum. For reacting forsterite, spectroscopic interrogations using nuclear magnetic resonance (NMR) can elucidate the changing magnesium coordination and bonding environment. In this study, we combine analysis of the changing solution chemistry with advanced NMR techniques ({sup 29}Si MAS, {sup 1}H-{sup 29}Si CP MAS, {sup 25}Mg QCPMG, and {sup 1}H-{sup 25}Mg CP QCPMG NMR) to probe leached layer formation and secondary phase precipitation during the dissolution of forsterite at 150 C.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exploring a New Regime of Molecular Orbital Physics in 4⁢d Cluster Magnets with Resonant Inelastic X-Ray Scattering

Molecular orbital systems with clusters of heavy transition metal (TM) ions are one of the most important classes of model materials for studying the interplay between local physics and effects of itinerancy. Despite a large number of candidates identified in the family of 4⁢d TM materials, an understanding of their physics from competing microscopic energy scales is still missing. Here, we bridge this gap by reporting the first resonant inelastic x-ray scattering (RIXS) measurement on a well-known series of Ru cluster magnets with a 6⁢H-perovskite structure Ba 3 ⁢M⁢Ru 2 ⁢O 9 (M 3+ = In 3+ , Y 3+ , La 3+ ) comprised of Ru dimers. In addition to providing a microscopic explanation for their anomalous magnetic properties, our RIXS measurements combined with theoretical modeling uncover a new regime of molecular orbital physics where the combined effect of large hopping and small spin-orbit coupling results in highly fragile electronic states in the Ru-dimer compounds directly manifested as an abrupt change in the RIXS spectrum accompanying a tiny change in the local structure tuned by the M-site ion. This unique combination of energy scales found only in the 4⁢d but not the 5⁢d cluster magnets highlights the value of these materials as a new platform for studying quantum phase transition involving molecular orbitals.

36 MATERIALS SCIENCE↗

MR-Guided High-Intensity Focused Ultrasound: Current Status of an Emerging Technology

The concept of ideal tumor surgery is to remove the neoplastic tissue without damaging adjacent normal structures. High-intensity focused ultrasound (HIFU) was developed in the 1940s as a viable thermal tissue ablation approach. In clinical practice, HIFU has been applied to treat a variety of solid benign and malignant lesions, including pancreas, liver, prostate, and breast carcinomas, soft tissue sarcomas, and uterine fibroids. More recently, magnetic resonance guidance has been applied for treatment monitoring during focused ultrasound procedures (magnetic resonance-guided focused ultrasound, MRgFUS). Intraoperative magnetic resonance imaging provides the best possible tumor extension and dynamic control of energy deposition using real-time magnetic resonance imaging thermometry. We introduce the fundamental principles and clinical indications of the MRgFUS technique; we also report different treatment options and personal outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Observation of a topological insulator Dirac cone reshaped by non-magnetic impurity resonance

The massless Dirac electrons found at topological insulator surfaces are thought to be influenced very little by weak, non-magnetic disorder. However, a resonance effect of strongly perturbing non-magnetic impurities has been theoretically predicted to change the dispersion and physical nature of low-energy quasiparticles, resulting in unique particle-like states that lack microscopic translational symmetry. Here we report the direct observation of impurities reshaping the surface Dirac cone of the model three-dimensional topological insulator bismuth selenide. A pronounced kink-like dispersion feature is observed in disorder-enriched samples, and found to be closely associated with the anomaly caused by impurity resonance in the surface state density of states, as observed by dichroic angle-resolved photoemission spectroscopy. The experimental observation of these features, which closely resemble theoretical predictions, has significant implications for the properties of topological Dirac cones in applied scenarios that commonly feature point-defect disorder at surfaces or interfaces. Topological insulators - influence of surface impurities: The electronic properties of topological insulators are robust against perturbations, including the presence of non-magnetic impurities. However, surface impurities can give rise to resonant states near the Dirac point, and if their density becomes sufficiently high it is predicted that they can substantially modify the dispersion of the Dirac cone and develop a collective behaviour that results in the formation of particle-like states that lack microscopic translational symmetry. L. Andrew Wray at Purdue University and at the New York University Shanghai, and colleagues, used angle-resolved photoemission spectroscopy to experimentally observe the reshaping of the surface Dirac cone in a defect-rich sample of the topological insulator Bi 2 Se 3 . These results indicate that surface impurities can provide a useful handle to control the properties of topological insulators.

36 MATERIALS SCIENCE↗

A system to detect cerebral aneurysms in multimodality angiographic data sets

Purpose: The early detection of cerebral aneurysms plays a major role in preventing subarachnoid hemorrhage. The authors present a system to automatically detect cerebral aneurysms in multimodal 3D angiographic data sets. The authors’ system is parametrizable for contrast-enhanced magnetic resonance angiography (CE-MRA), time-of-flight magnetic resonance angiography (TOF-MRA), and computed tomography angiography (CTA). Methods: Initial volumes of interest are found by applying a multiscale sphere-enhancing filter. Several features are combined in a linear discriminant function (LDF) to distinguish between true aneurysms and false positives. The features include shape information, spatial information, and probability information. The LDF can either be parametrized by domain experts or automatically by training. Vessel segmentation is avoided as it could heavily influence the detection algorithm. Results: The authors tested their method with 151 clinical angiographic data sets containing 112 aneurysms. The authors reach a sensitivity of 95% with CE-MRA data sets at an average false positive rate per data set (FP{sub DS}) of 8.2. For TOF-MRA, we achieve 95% sensitivity at 11.3 FP{sub DS}. For CTA, we reach a sensitivity of 95% at 22.8 FP{sub DS}. For all modalities, the expert parametrization led to similar or better results than the trained parametrization eliminating the need for training. 93% of aneurysms that were smaller than 5 mm were found. The authors also showed that their algorithm is capable of detecting aneurysms that were previously overlooked by radiologists. Conclusions: The authors present an automatic system to detect cerebral aneurysms in multimodal angiographic data sets. The system proved as a suitable computer-aided detection tool to help radiologists find cerebral aneurysms.

60 APPLIED LIFE SCIENCES↗

Inter- and Intrafractional Tumor and Organ Movement in Patients With Cervical Cancer Undergoing Radiotherapy: A Cinematic-MRI Point-of-Interest Study

Purpose: Internal tumor and organ movement is important when considering intensity-modulated radiotherapy for patients with cancer of the cervix because of the tight margins and steep dose gradients. In this study, the internal movement of the tumor, cervix, and uterus were examined using serial cinematic magnetic resonance imaging scans and point-of-interest analysis. Methods and Materials: Twenty patients with Stage IB-IVA cervical cancer underwent pelvic magnetic resonance imaging before treatment and then weekly during external beam radiotherapy. In each 30-min session, sequential T{sub 2}-sagittal magnetic resonance imaging scans were obtained. The points of interest (cervical os, uterine canal, and uterine fundus) were traced on each image frame, allowing the craniocaudal and anteroposterior displacements to be measured. The mean displacements and trends were analyzed using mixed linear models. Prediction intervals were calculated to determine the internal target margins. Results: Large interscan motion was found for all three points of interest that was only partially explained by the variations in bladder and rectal filling. The intrascan motion was much smaller. Both inter- and intrascan motion was greatest at the fundus of the uterus, less along the canal, and least at the cervical os. The isotropic internal target margins required to encompass 90% of the interscan motion were 4 cm at the fundus and 1.5 cm at the os. In contrast, smaller margins of 1 cm and 0.45 cm, respectively, were adequate to encompass the intrascan motion alone. Conclusion: Daily soft-tissue imaging with correction for interfractional motion or adaptive replanning will be important if the benefits of intensity-modulated radiotherapy are to be maximized in women with cervical cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Postpartum Hemorrhage Treated with Gelfoam Slurry Embolization Using the Superselective Technique: Immediate Results and 1-Month MRI Follow-up

To evaluate the efficacy and safety of superselective embolization of the uterine arteries in a postpartum hemorrhage. Between November 2004 and January 2011, a total of 44 consecutive women (median {+-} standard deviation age 34 {+-} 3 years, range 23-41 years) were referred to our institution for postpartum intractable hemorrhage management. All patients were embolized with a microcatheter that was placed deep into the uterine arteries upstream of the cervical arteries. The embolic agent was a mixture of contrast medium and 5 Multiplication-Sign 5 Multiplication-Sign 5 cm pieces of gelfoam (Gelita-Spon) modified into a gelatin emulsion as follows: rapid mixing through a three-way stopcock with two 2.5-ml syringes. A 1-ml syringe was used for injection. One month after embolization, all patients underwent magnetic resonance imaging and clinical examination. Technical and clinical success was obtained in all cases. Thirty-five patients experienced bleeding related to poor retraction of the uterus, 7 patients because of a tear of the cervix and 2 because of a vaginal hematoma. Pre- and postembolization red blood cell transfusions were (mean {+-} standard deviation [SD]) 6 {+-} 1.2 (range 3-8) U and 2 {+-} 0.7 (range 2-4) U, respectively. One-month magnetic resonance imaging follow-up revealed no sign of ischemic myometrium or necrosis, and no instances of uterine rupture and no pelvic vein thrombosis. Incidental findings included two small intramyometrial hematic collections. All uterine arteries were patent via magnetic resonance angiography. Seventeen patients had concomitant fibroids, all of which appeared hypovascular. This technique permits good, safe clinical results with no marked damage to the uterine arteries or the uterus itself.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single-resonator double-negative metamaterial

Resonances can be tuned in dielectric resonators in order to construct single-resonator, negative-index metamaterials. For example, high-contrast inclusions in the form of metallic dipoles can be used to shift the first electric resonance down (in frequency) to the first magnetic resonance, or alternatively, air splits can be used to shift the first magnetic resonance up (in frequency) near the first electric resonance. Degenerate dielectric designs become especially useful in infrared- or visible-frequency applications where the resonator sizes associated with the lack of high-permittivity materials can become of sufficient size to enable propagation of higher-order lattice modes in the resulting medium.

36 MATERIALS SCIENCE↗

Manipulation of quantum dot emission with semiconductor metasurfaces exhibiting magnetic quadrupole resonances

Optical metasurfaces were suggested as a route for engineering advanced light sources with tailored emission properties. In particular, they provide a control over the emission directionality, which is essential for single-photon sources and LED applications. Here, we experimentally study light emission from a metasurface composed of III-V semiconductor Mie-resonant nanocylinders with integrated quantum dots (QDs). Specifically, we focus on the manipulation of the directionality of spontaneous emission from the QDs due to excitation of different magnetic quadrupole resonances in the nanocylinders. To this end, we perform both back focal plane imaging and momentum-resolved spectroscopy measurements of the emission. This allows for a comprehensive analysis of the effect of the different resonant nanocylinder modes on the emission characteristics of the metasurface. Our results show that the emission directionality can be manipulated by an interplay of the excited quadrupolar nanocylinder modes with the metasurface lattice modes and provide important insights for the design of novel smart light sources and new display concepts.

Vaskin, Aleksandr↗

Microstructure from joint analysis of experimental data and ab initio interactions: Hydrogenated amorphous silicon

A study of the formation of voids and molecular hydrogen in hydrogenated amorphous silicon is presented based upon a hybrid approach that involves inversion of experimental nuclear magnetic resonance data in conjunction with ab initio total-energy relaxations in an augmented solution space. The novelty of this approach is that the voids and molecular hydrogen appear naturally in the model networks unlike conventional approaches, where voids are created artificially by removing silicon atoms from the networks. Two representative models with 16 and 18 at. % of hydrogen are studied in this work. The result shows that the microstructure of the a-Si:H network consists of several microvoids and few molecular hydrogen for concentration above 15 at. % H. The microvoids are highly irregular in shape and size, and have a linear dimension of 5–7 Å. The internal surface of a microvoid is found to be decorated with 4–9 hydrogen atoms in the form of monohydride Si–H configurations as observed in nuclear magnetic resonance experiments. The microstructure consists of (0.9–1.4)% hydrogen molecules of total hydrogen in the networks. These observations are consistent with the outcome of infrared spectroscopy, nuclear magnetic resonance, and calorimetry experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Taming harmful bursts and heat flux in high-confinement tokamak plasmas

A major challenge in tokamak fusion research is first-wall erosion caused by steady heat loads and sudden energy bursts known as edge-localized modes. Divertor detachment reduces steady-state heat flux, while resonant magnetic perturbations can suppress these instabilities. However, integrating the two has been difficult because they require conflicting operating conditions. Here we demonstrate simultaneous achievement of resonant magnetic perturbations mitigated small edge-localized modes and impurity seeded partial divertor detachment in plasmas with an ITER-similar shape on the DIII-D tokamak. Experiments and simulations show that resonant magnetic perturbations facilitate detachment by redistributing particles, lowering the core density and increasing the scrape-off layer density, thereby reducing the amount of injected gas required. Cooling-gas injection eliminates the secondary heat-flux peak created by three-dimensional magnetic lobes, while edge cooling weakens the plasma response to the applied magnetic fields. These advances illustrate a viable pathway for integrating edge stability control with power exhaust in future fusion reactors.

magnetically confined plasmas↗

Low-noise pulsed pre-polarization magnet system for ultra-low field NMR

A liquid cooled, pulsed electromagnet of solenoid configuration suitable for duty in an ultra-low field nuclear magnetic resonance system has been designed, fabricated and successfully operated. The magnet design minimizes Johnson noise, minimizes the hydrogen signal and incorporates minimal metal and no ferromagnetic materials. In addition, an acoustically quiet cooling system permitting 50% duty cycle operation was achieved by designing for single-phase, laminar flow, forced convection cooling. Winding, conductor splicing and epoxy impregnation techniques were successfully developed to produce a coil winding body with integral cooling passageways and adequate structural integrity. Issues of material compatibility, housing, coolant flow system and heat rejection system design will be discussed. Additionally, this pulsed electromagnet design has been extended to produce a boiling liquid cooled version in a paired solenoid configuration suitable for duty in an ultra-low field nuclear magnetic resonance system. This pair of liquid nitrogen cooled coils is currently being tested and commissioned. Issues of material compatibility, thermal insulation, thermal contraction, housing and coolant flow design are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗