Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Locating Profile”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

GAS EXCITATION IN ULIRGs: MAPS OF DIAGNOSTIC EMISSION-LINE RATIOS IN SPACE AND VELOCITY

Emission-line spectra extracted at multiple locations across 39 ultraluminous infrared galaxies have been compiled into a spectrophotometric atlas. Line profiles of H{alpha}, [N II], [S II], [O I], H{beta}, and [O III] are resolved and fit jointly with common velocity components. Diagnostic ratios of these line fluxes are presented in a series of plots, showing how the Doppler shift, line width, gas excitation, and surface brightness change with velocity at fixed position and also with distance from the nucleus. One general characteristic of these spectra is the presence of shocked gas extending many kiloparsecs from the nucleus. In some systems, the rotation curves of the emitting gas indicate motions that suggest gas disks, which are most frequent at early merger stages. At these early merger stages, the emission line ratios indicate the presence of shocked gas, which may be triggered by the merger event. We also report the general characteristics of the integrated spectra.

79 ASTRONOMY AND ASTROPHYSICS↗

Dosimetric and geometric evaluation of a novel stereotactic radiotherapy device for breast cancer: The GammaPod Trade-Mark-Sign

Purpose: A dedicated stereotactic gamma irradiation device, the GammaPod Trade-Mark-Sign from Xcision Medical Systems, was developed specifically to treat small breast cancers. This study presents the first evaluation of dosimetric and geometric characteristics from the initial prototype installed at University of Maryland Radiation Oncology Department. Methods: The GammaPod Trade-Mark-Sign stereotactic radiotherapy device is an assembly of a hemi-spherical source carrier containing 36 {sup 60}Co sources, a tungsten collimator, a dynamically controlled patient support table, and the breast immobilization system which also functions as a stereotactic frame. The source carrier contains the sources in six columns spaced longitudinally at 60 Degree-Sign intervals and it rotates together with the variable-size collimator to form 36 noncoplanar, concentric arcs focused at the isocenter. The patient support table enables motion in three dimensions to position the patient tumor at the focal point of the irradiation. The table moves continuously in three cardinal dimensions during treatment to provide dynamic shaping of the dose distribution. The breast is immobilized using a breast cup applying a small negative pressure, where the immobilization cup is embedded with fiducials also functioning as the stereotactic frame for the breast. Geometric and dosimetric evaluations of the system as well as a protocol for absorbed dose calibration are provided. Dosimetric verifications of dynamically delivered patient plans are performed for seven patients using radiochromic films in hypothetical preop, postop, and target-in-target treatment scenarios. Results: Loaded with 36 {sup 60}Co sources with cumulative activity of 4320 Ci, the prototype GammaPod Trade-Mark-Sign unit delivers 5.31 Gy/min at the isocenter using the largest 2.5 cm diameter collimator. Due to the noncoplanar beam arrangement and dynamic dose shaping features, the GammaPod Trade-Mark-Sign device is found to deliver uniform doses to targets with good conformity. The spatial accuracy of the device to locate the radiation isocenter is determined to be less than 1 mm. Single shot profiles with 2.5 cm collimator are measured with radiochromic film and found to be in good agreement with respect to the Monte Carlo based calculations (congruence of FWHM less than 1 mm). Dosimetric verifications corresponding to all hypothetical treatment plans corresponding to three target scenarios for each of the seven patients demonstrated good agreement with gamma index pass rates of better than 97% (99.0%{+-} 0.7%). Conclusions: Dosimetric evaluation of the first GammaPod Trade-Mark-Sign stereotactic breast radiotherapy unit was performed and the dosimetric and spatial accuracy of this novel technology is found to be feasible with respect to clinical radiotherapy standards. The observed level of agreement between the treatment planning system calculations and dosimetric measurements has confirmed that the system can deliver highly complex treatment plans with remarkable geometric and dosimetric accuracy.

60 APPLIED LIFE SCIENCES↗

CalderaCast User Manual Version 1.0

CalderaCast is a user-friendly web-based tool for electrical-load forecast, providing stakeholders with a fully customizable decision-support framework that estimates the likely power draw from a possible future electric-vehicle (EV) charging station at a given location on a given day along an alternative fuel corridor (AFC). These EV charging profiles are accurately modeled in CalderaCast using the Caldera software framework developed by Idaho National Laboratories (INL), reflecting the realistic charging levels observed in actual charge events. This tool was developed as part of the National Electric Vehicle Infrastructure (NEVI) program, which is quickly generating substantial interest from would-be charging station operators (CSO), large and small electric utilities, and state transportation planners, some of whom had not seriously considered EV charging previously. All these entities—with or without background in EV infrastructure—must estimate the electricity load that a proposed charging station will generate. This load forecast is critically important for a utility to properly assess the capacity of their distribution network to support the proposed station or properly size grid upgrades for potential load growth due to future EV adoption, vehicle technology improvements, or station growth. This document describes each aspect of the CalderaCast tool and provides guidance to users who are interested in utilizing the tool for their work.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Relaxation mechanisms, structure and properties of semi-coherent interfaces

In this work, using the Cu–Ni (111) semi-coherent interface as a model system, we combine atomistic simulations and defect theory to reveal the relaxation mechanisms, structure, and properties of semi-coherent interfaces. By calculating the generalized stacking fault energy (GSFE) profile of the interface, two stable structures and a high-energy structure are located. During the relaxation, the regions that possess the stable structures expand and develop into coherent regions; the regions with high-energy structure shrink into the intersection of misfit dislocations (nodes). This process reduces the interface excess potential energy but increases the core energy of the misfit dislocations and nodes. The core width is dependent on the GSFE of the interface. The high-energy structure relaxes by relative rotation and dilatation between the crystals. The relative rotation is responsible for the spiral pattern at nodes. The relative dilatation is responsible for the creation of free volume at nodes, which facilitates the nodes’ structural transformation. Several node structures have been observed and analyzed. In conclusion, the various structures have significant impact on the plastic deformation in terms of lattice dislocation nucleation, as well as the point defect formation energies.

36 MATERIALS SCIENCE↗

Low altitude temperature and humidity profile data for application to aircraft noise propagation

A data search of the weather statistics from 11 widely dispersed geographical locations within the continental United States was conducted. The sites, located long both sea-coasts and in the interior, span the northern, southern, and middle latitudes. The weather statistics, retrieved from the records of these 11 sites, consist of two daily observations taken over a 10-year period. The data were sorted with respect to precipitation and surface winds and classified into temperature intervals of 5 C and relative humidity intervals of 10 percent for the lower 1400 meters of the atmosphere. These data were assembled in a statistical format and further classified into altitude increments of 200 meters. The data are presented as sets of tables for each site by season of the year and include both daily observations.

Connor, A. B.↗

Effect of fuel/air nonuniformity on nitric oxide emissions

A flame tube combustor holding jet A fuel was used in experiments performed at a pressure of .3 Mpa and a reference velocity of 25 meters/second for three inlet air temperatures of 600, 700, and 800 K. The gas sample measurements were taken at locations 18 cm and 48 cm downstream of the perforated plate flameholder. Nonuniform fuel/air profiles were produced using a fuel injector by separately fueling the inner five fuel tubes and the outer ring of twelve fuel tubes. Six fuel/air profiles were produced for nominal overall equivalence ratios of .5 and .6. An example of three of three of these profiles and their resultant nitric oxide NOx emissions are presented. The uniform fuel/air profile cases produced uniform and relatively low profile levels. When the profiles were either center-peaked or edge-peaked, the overall mass-weighted nitric oxide levels increased.

Lyons, V. J.↗

Microwave radiometer measurements of soil moisture content

A unique set of radiometer measurements is presented, recorded during a 1000-h day and night monitoring of irrigated fields from fully saturated to completely dry. Radiometer measurements were recorded at 2.8-cm (X-band) and 21.4-cm (L-band) wavelengths for a range of incident angles from nadir to 50 deg. Soil moisture and soil temperature profile measurements were recorded to a depth of 15 cm. The test site was located in east-central Texas on a clay soil (Miller clay). Three bare-surface plots were used, each having a distinctly different surface roughness. Vegetated plots were also measured. The data quantify the sensitivity of microwave radiometer measurements to soil moisture variations, the effect of surface roughness on the measurement, and the influence of surface vegetation.

Newton, R. W.↗

Flow improvements in the circuit of the Langley 4- by 7-meter tunnel

In order to identify the most promising means for improving the flow in the Langley 4- by 7-Meter Tunnel, detailed surveys of the mean velocity profiles were measured in both the horizontal and vertical planes of symmetry at specific locations throughout the tunnel circuit. These data were obtained at test-section dynamic pressures of 1.53, 2.78, and 4.79 kPa (3 2, 58, and 100 psf, respectively) for tunnel operation in both the closed and open test-section configurations. In the base-line tunnel-flow surveys, the flow patterns near the end of the test section indicate a uniform mean velocity distribution. Downstream of the test section, unsymmetrical flow patterns result in low velocities along the inner walls and in flow separation along the inner wall of the diffuser upstream of the drive fan and along the outer wall of the large diffuser downstream of the drive fan. In order to correct these unsymmetrical flow patterns, a set of trailing-edge flaps attached to the five flow-control vanes located just downstream of the first corner were installed. These flaps were very successful in making the tunnel flow more symmetrical and in eliminating the regions of separation in the diffusers upstream and downstream of the drive fan.

Zachary T Applin↗

Vector wind gust model

The development of a vector wind gust model through statistical analysis is described. Wind perturbation statistics which include location, altitude, season, and wavelength range are used in the synthesis of detailed wing profiles. These profiles provide the basis for the establishment of improved discrete gust design criteria guidelines for ascending launch vehicles.

Adelfang, S. I.↗

Clear air turbulence avoidance using an airborne microwave radiometer

The avoidance of Clear Air Turbulence (CAT) is theoretically possible by selecting flight levels that are a safe distance from the tropopause and inversion layers. These favored sites for CAT generation can be located by an 'airborne microwave radiometer' (AMR) passive sensor system that measures altitude temperature profiles. A flight evaluation of the AMR sensor shows that most CAT could be avoided by following sensor-based advisories. Some limitations still exist for any hypothetical use of the sensor. The principal need is to augment the sensor's 'where' advisories to include useful 'when' forecasts.

Gary, B. L.↗

Incorporating geometric and radiative effects into infrared scanning computer analysis

A NASA program, the SILTS experiment (Shuttle Infrared Leeside Temperature Sensing) will utilize an infrared scanning system mounted at the tip of the vertical stabilizer to remotely measure the surface temperature of the leeside of the Space Shuttle during entry from orbit. Scans of the fuselage and one wing will be made alternately. The experiment will correlate real full scale data to ground-based information. In order to quantitatively assess the temperature profile of the surface, an algorithm is required which incorporates the Space Shuttle shape, location of specific materials on the surface, and the measurement geometry between the camera and the surface. This paper will discuss the algorithm.

Myrick, D. L.↗

Calculated occultation profiles of Io and the hot spots

Occultations of Io by other Galilean satellites in 1985 provide a means to locate volcanic hot spots and to model their temperatures. The expected time variations in the integral reflected and emitted radiation of the occultations are computed as a function of wavelength (visual to 8.7 microns). The best current ephemerides were used to calculate the geometry of each event as viewed from earth. Visual reflectances were modeled from global mosaics of Io. Thermal emission from the hot spots was calculated from Voyager 1 IRIS observations and, for regions unobserved by IRIS, from a model based on the distribution of low-albedo features. The occultations may help determine (1) the location and temperature distribution of Loki; (2) the source(s) of excess emission in the region from long 50 deg to 200 deg and (3) the distribution of small, high-temperature sources.

Mcewen, A. S.↗

Field experiment for measurement of the radiative characteristics of a hazy atmosphere

Theoretical two-dimensional and three-dimensional solutions to the radiative-transfer equation have been applied to the earth-atmosphere system. A field experiment was conducted to test this theory. In the experiment the upward radiance was measured above and below a haze layer during simultaneous measurements of the haze characteristics. The measurements were conducted at a narrow near-IR channel (773 + or - 22 nm) which represents the visible and near-IR spectral region. The aerosol vertical optical thickness at eight wavelengths, as well as the vertical and horizontal profiles of the scattering coefficient, the temperature, and dew point were measured at several locations. These measurements quantified the vertical and spatial structure of the atmospheric haze and the atmospheric radiation. The result was a well-defined radiative-transfer experiment. The experimental data set is used to quantify the haze effect on upward radiance, including the adjacency effect (the effect of a bright area on the upward radiance measured above a dark adjacent area), and to test radiative-transfer models for a plane-parallel atmosphere above a nonuniform surface. A comparison is given between the theoretical prediction of upward radiance above the haze and the measurement. Agreement between theory and the experiment is discussed.

Kaufman, Y. J.↗

Planetary Spectroscopy

The goal of this task is to acquire physical data on the atmospheres of the outer planets and Titan by means of ground-based spectroscopy, spectrophotometry, and spectral imaging at visible to near-infrared wavelengths (approximately 0.3 to 2.5 micrometer). These data constrain physical parameters which characterize properties and distribution of aerosols in the atmospheres of these bodies. Reduced spectral imaging of Neptune was accomplished. The data were analyzed in several ways. Direct inspection of images reveals the distribution of discrete clouds in the atmosphere, which indicate that the global distribution of clouds has changed since earlier imaging. Disk-integrated photometry obtained from the images demonstrates that the diurnal variability at methane-band wavelengths is caused by the presence of discrete clouds; short-term variability is also seen in the rotational light curve, providing evidence for modification of cloud structure on the planet. The center-to-limb brightness profiles of the equatorial region of Neptune were analyzed, which provided constraints on the location, albedos, and optical depths of aerosol scattering layers in the troposphere and lower stratosphere.

Bergstralh, Jay T.↗

Determination of shuttle orbiter center of gravity from flight measurements

Flight measurements of pitch, yaw, and roll rates and the resultant rotationally induced linear accelerations during three orbital maneuvers on Shuttle mission space transportation system (STS) 61-C were used to calculate the actual orbiter center-of-gravity location. The calculation technique reduces error due to lack of absolute calibration of the accelerometer measurements and compensates for accelerometer temperature bias and for the effects of gravity gradient. Accuracy of the technique was found to be limited by the nonrandom and asymmetrical distribution of orbiter structural vibration at the accelerometer mounting location. Fourier analysis of the vibration was performed to obtain the power spectral density profiles which show magnitudes in excess of 10(exp 4) ug (sup 2)/Hz for the actual vibration and over 500 ug (sup 2)/Hz for the filtered accelerometer measurements. The data from this analysis provide a characterization of the Shuttle acceleration environment which may be useful in future studies related to accelerometer system application and zero-g investigations or processes.

Hinson, E. W.↗

Analysis, design, and experimental results for lightweight space heat receiver canisters, phase 1

Critical technology experiments have been performed on thermal energy storage modules in support of the Brayton Advanced Heat Receiver program. The modules are wedge-shaped canisters designed to minimize the mechanical stresses that occur during the phase change of the lithium fluoride phase change material. Nickel foam inserts were used in some of the canisters to provide thermal conductivity enhancement and to distribute the void volume. Two canisters, one with a nickel foam insert, and one without, were thermally cycled in various orientations in a fluidized bed furnace. The only measurable impact of the nickel foam was seen when the back and short sides of the canister were insulated to simulate operation in the advanced receiver design. In tests with insulation, the furnace to back side delta T was larger in the canister with the nickel foam insert, probably due to the radiant absorptivity of the nickel. However, the differences in the temperature profiles of the two canisters were small, and in many cases the profiles matched fairly well. Computed Tomography (CT) was successfully used to nondestructively demarcate void locations in the canisters. Finally, canister dimensional stability, which was measured throughout the thermal cycling test program with an inspection fixture was satisfactory with a maximum change of 0.635 mm (0.025 in.).

Schneider, Michael G.↗

A description of QUALCOMM Automatic Satellite Position Reporting (QASPR(R)) for mobile communications

Two satellite position reporting has been introduced into the OmniTRACS mobile satellite communication system. This system significantly improves position reporting reliability and accuracy while simplifying the terminal's hardware. The positioning technique uses the original OmniTRACS TDMA timing signal formats in the forward and return link directions plus an auxiliary, low power forward link signal through a second satellite to derive distance values. The distances are then converted into the mobile terminal's latitude and longitude in real time. A minor augmentation of the spread spectrum profile of the return link allowed the resolution of periodic ambiguities. The system also locates the two satellites in real time with fixed platforms in known locations using identical mobile terminal hardware. Initial accuracies of 1/4 mile have been realized uniformly throughout the USA using a satellite separation of 22 degrees and there are no dead zones, skywaves, or cycle slips as found in terrestrial systems like LORAN-C.

Ames, William G.↗