Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Load flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

A new computational model for the prediction of mass loading phenomena for solar wind interactions with cometary and planetary ionospheres

The modified gasdynamic convected-magnetic-field MHD model developed by Spreiter and Stahara (1980) to simulate the supersonic flow of the solar wind past planetary magnetoionospheres is extended to account for cases (such as Venus and comets) in which significant numbers of neutral atmospheric atoms become ionized in the surrounding flow and add to its momentum, energy, and mass. The mathematical model and the solution procedures for the nose and tail regions are explained; typical computational grids are shown; and numerical results for a comet and for the Venus ionosheath and bow shock are presented graphically. It is found that the bow shock weakens and moves further upstream of the obstacle as mass loading is increased and the flow upstream of the bow shock becomes more compressed.

Stahara, Stephen S.↗

Performance of a CW double electric discharge for supersonic CO lasers

The results of an experimental investigation of a CW double discharge in supersonic CO mixtures are reported. Stable discharges in CO/N2 and CO/Ar mixtures, with a maximum energy loading of 0.5 eV/CO molecule, were achieved in a small-scale continuous-flow supersonic channel. Detailed measurements of the discharge characteristics were performed, including electrostatic probe measurements of floating potential and electron number density and spectroscopic measurements of the CO vibrational population distributions. The results of these measurements indicate that the vibrational excitation efficiency of the discharge is approximately 60%, for moderate levels of main discharge current. These experiments, on a small scale, demonstrate that the double-discharge scheme provides adequate vibrational energy loading for efficient CO laser operation under CW supersonic flow conditions.

Stanton, A. C.↗

Thermal Vacuum Testing of a Proto-flight Miniature Loop Heat Pipe with Two Evaporators and Two Condensers

This paper describes thermal vacuum testing of a proto-flight miniature loop heat pipe (MLHP) with two evaporators and two condensers designed for future small systems applications requiring low mass, low power and compactness. Each evaporator contains a wick with an outer diameter of 6.35 mm, and each has its own integral compensation chamber (CC). Miniaturization of the loop components reduces the volume and mass of the thermal system. Multiple evaporators provide flexibility for placement of instruments that need to be maintained at the same temperature, and facilitate heat load sharing among instruments, reducing the auxiliary heater power requirement. A flow regulator is used to regulate heat dissipations between the two condensers, allowing flexible placement of radiators on the spacecraft. A thermoelectric converter (TEC) is attached to each CC for control of the operating temperature and enhancement of start-up success. Tests performed include start-up, power cycle, sink temperature cycle, high power and low power operation, heat load sharing, and operating temperature control. The proto-flight MLHP demonstrated excellent performance in the thermal vacuum test. The loop started successfully and operated stably under various evaporator heat loads and condenser sink temperatures. The TECs were able to maintain the loop operating temperature within b1K of the desired set point temperature at all power levels and all sink temperatures. The un-powered evaporator would automatically share heat from the other powered evaporator. The flow regulator was able to regulate the heat dissipation among the radiators and prevent vapor from flowing into the liquid line.

Ku, Jentung↗

Investigations of the influence of the profile thickness of the compressible plane flow through compressor cascades

Flow-through cascade of an aircraft turbine compressor is studied experimentally over wide range of Reynolds numbers and subsonic Mach numbers; it was found that deterioration of flow properties due to decreasing Reynolds numbers is less noticeable on thin profiles than on thick ones; however, thick profiles are advantageous in compressors designed for efficient partial load behavior because thick profiles have a relatively large range of usable inlet flow angles.

Bahr, J.↗

Dynamic force response of spherical hydrostatic journal bearing for cryogenic applications

Hydrostatic Journal Bearings (HJB's) are reliable and resilient fluid film rotor support elements ideal to replace roller bearings in cryogenic turbomachinery. HJB' will be used for primary space-power applications due to their long lifetime, low friction and wear, large load capacity, large direct stiffness, and damping force coefficients. An analysis for the performance characteristics of turbulent flow, orifice compensated, spherical hydrostatic journal bearings (HJB's) is presented. Spherical bearings allow tolerance for shaft misalignment without force performance degradation and have also the ability to support axial loads. The spherical HJB combines these advantages to provide a bearing design which could be used efficiently on high performance turbomachinery. The motion of a barotropic liquid on the thin film bearing lands is described by bulk-flow mass and momentum equations. These equations are solved numerically using an efficient CFD method. Numerical predictions of load capacity and force coefficients for a 6 recess, spherical HJB in a LO2 environment are presented. Fluid film axial forces and force coefficients of a magnitude about 20% of the radial load capacity are predicted for the case analyzed. Fluid inertia effects, advective and centrifugal, are found to affect greatly the static and dynamic force performance of the bearing studied.

Sanandres, Luis↗

A zonal method for modeling powered-lift aircraft flow fields

A zonal method for modeling powered-lift aircraft flow fields is based on the coupling of a three-dimensional Navier-Stokes code to a potential flow code. By minimizing the extent of the viscous Navier-Stokes zones the zonal method can be a cost effective flow analysis tool. The successful coupling of the zonal solutions provides the viscous/inviscid interations that are necessary to achieve convergent and unique overall solutions. The feasibility of coupling the two vastly different codes is demonstrated. The interzone boundaries were overlapped to facilitate the passing of boundary condition information between the codes. Routines were developed to extract the normal velocity boundary conditions for the potential flow zone from the viscous zone solution. Similarly, the velocity vector direction along with the total conditions were obtained from the potential flow solution to provide boundary conditions for the Navier-Stokes solution. Studies were conducted to determine the influence of the overlap of the interzone boundaries and the convergence of the zonal solutions on the convergence of the overall solution. The zonal method was applied to a jet impingement problem to model the suckdown effect that results from the entrainment of the inviscid zone flow by the viscous zone jet. The resultant potential flow solution created a lower pressure on the base of the vehicle which produces the suckdown load. The feasibility of the zonal method was demonstrated. By enhancing the Navier-Stokes code for powered-lift flow fields and optimizing the convergence of the coupled analysis a practical flow analysis tool will result.

Roberts, D. W.↗

Rolling moments in a trailing vortex flow field

Pressure distributions are presented which were measured on a wing in close proximity to a tip vortex of known structure generated by a larger, upstream semispan wing. Overall loads calculated by integration of these pressures are checked by independent measurements made with an identical model mounted on a force balance. Several conventional methods of wing analysis are used to predict the loads on the following wing. Strip theory is shown to give uniformly poor results for loading distribution, although predictions of overall lift and rolling moment are sometimes acceptable. Good results are obtained for overall coefficients and loading distribution by using linearized pressures in vortex-lattice theory in conjunction with a rectilinear vortex. The equivalent relation from reverse-flow theory that can be used to give economic predictions for overall loads is presented.

Mcmillan, O. J.↗

Rolling moments in a trailing vortex flow field

Pressure distributions are presented which were measured on a wing in close proximity to a tip vortex of known structure generated by a larger, upstream semispan wing. Overall loads calculated by integration of these pressures are checked by independent measurements made with an identical model mounted on a force balance. Several conventional methods of wing analysis are used to predict the loads on the following wing. Strip theory is shown to give uniformly poor results for loading distribution, although predictions of overall lift and rolling moment are sometimes acceptable. Good results are obtained for overall coefficients and loading distribution by using linearized pressures in vortex-lattice theory in conjunction with a rectilinear vortex. The equivalent relation from reverse-flow theory that can be used to give economic predictions for overall loads is presented.

Mcmillan, O. J.↗

Fracture Sustainability in Enhanced Geothermal Systems: Experimental and Modeling Constraints

Enhanced geothermal systems (EGS) offer the potential for a much larger energy source than conventional hydrothermal systems. Hot, low-permeability rocks are prevalent at depth around the world, but the challenge of extracting thermal energy depends on the ability to create and sustain open fracture networks. Laboratory experiments were conducted using a suite of selected rock cores (granite, metasediment, rhyolite ash-flow tuff, and silicified rhyolitic tuff) at relevant pressures (uniaxial loading up to 20.7 MPa and fluid pressures up to 10.3 MPa) and temperatures (150–250 °C) to evaluate the potential impacts of circulating fluids through fractured rock by monitoring changes in fracture aperture, mineralogy, permeability, and fluid chemistry. Because a fluid in disequilibrium with the rocks (deionized water) was used for these experiments, there was net dissolution of the rock sample: this increased with increasing temperature and experiment duration. Thermal-hydrological-mechanical-chemical (THMC) modeling simulations were performed for the rhyolite ash-flow tuff experiment to test the ability to predict the observed changes. These simulations were performed in two steps: a thermal-hydrological-mechanical (THM) simulation to evaluate the effects of compression of the fracture, and a thermal-hydrological-chemical (THC) simulation to evaluate the effects of hydrothermal reactions on the fracture mineralogy, porosity, and permeability. Furthermore, these experiments and simulations point out how differences in rock mineralogy, fluid chemistry, and geomechanical properties influence how long asperity-propped fracture apertures may be sustained. Such core-scale experiments and simulations can be used to predict EGS reservoir behavior on the field scale.

15 GEOTHERMAL ENERGY↗

Left ventricular outflow tract mean systolic acceleration as a surrogate for the slope of the left ventricular end-systolic pressure-volume relationship

OBJECTIVE: The goal of this study was to analyze left ventricular outflow tract systolic acceleration (LVOT(Acc)) during alterations in left ventricular (LV) contractility and LV filling. BACKGROUND: Most indexes described to quantify LV systolic function, such as LV ejection fraction and cardiac output, are dependent on loading conditions. METHODS: In 18 sheep (4 normal, 6 with aortic regurgitation, and 8 with old myocardial infarction), blood flow velocities through the LVOT were recorded using conventional pulsed Doppler. The LVOT(Acc) was calculated as the aortic peak velocity divided by the time to peak flow; LVOT(Acc) was compared with LV maximal elastance (E(m)) acquired by conductance catheter under different loading conditions, including volume and pressure overload during an acute coronary occlusion (n = 10). In addition, a clinically validated lumped-parameter numerical model of the cardiovascular system was used to support our findings. RESULTS: Left ventricular E(m) and LVOT(Acc) decreased during ischemia (1.67 +/- 0.67 mm Hg.ml(-1) before vs. 0.93 +/- 0.41 mm Hg.ml(-1) during acute coronary occlusion [p < 0.05] and 7.9 +/- 3.1 m.s(-2) before vs. 4.4 +/- 1.0 m.s(-2) during coronary occlusion [p < 0.05], respectively). Left ventricular outflow tract systolic acceleration showed a strong linear correlation with LV E(m) (y = 3.84x + 1.87, r = 0.85, p < 0.001). Similar findings were obtained with the numerical modeling, which demonstrated a strong correlation between predicted and actual LV E(m) (predicted = 0.98 [actual] -0.01, r = 0.86). By analysis of variance, there was no statistically significant difference in LVOT(Acc) under different loading conditions. CONCLUSIONS: For a variety of hemodynamic conditions, LVOT(Acc) was linearly related to the LV contractility index LV E(m) and was independent of loading conditions. These findings were consistent with numerical modeling. Thus, this Doppler index may serve as a good noninvasive index of LV contractility.

Non-NASA Center↗

Treatment of Lagoon Dairy Manure Wastewater via Iron Electrocoagulation, Microfiltration, and Adsorption

Dairy manure wastewater generated by flushing barn cow waste contains nutrients, pathogens, and organic and inorganic contaminants. This study utilized a process consisting of iron electrocoagulation (Fe-EC), microfiltration (MF), and activated carbon (AC) adsorption to treat farm wastewater and explore the reclamation of clean water for irrigation and livestock consumption. Significant removal (>99.9%) of chemical oxygen demand (COD), total organic carbon (TOC), phosphorus (P), turbidity, and microorganisms, as well as ions including magnesium, calcium, sulfur, and silica was achieved by the combined EC-MF-AC process. Specifically, a charge loading of ∼37,500 C/L in a continuous-flow EC configuration, followed by MF, achieved more than 95% removal of TOC and COD. Characterization of produced flocs and foam via scanning-electron microscopy with energy-dispersal spectroscopy and Fourier transform infrared spectroscopy confirmed the removal of ions, including calcium, sulfur, and silica. A key finding was the electrocatalytic conversion of nitrogen species to ammonia gas through the intermediate reduction of nitrate/nitrite, which led to ∼60% total nitrogen (TN) removal. AC treatment further improved TN removal to ∼70%. The Fe-EC process also eradicated >99.9% of bacteria. Preliminary process cost assessment, based on recycled materials for EC electrodes, showed significant cost savings (∼2 times) compared to commercial electrodes.

Dutta, Swapnamoy [ORNL]↗

Feasibility of an Accelerometer-Based Structural Health Monitoring System for the LANL Blast Tube

A modeling- and simulation-based study was conducted on the feasibility of implementing an accelerometer-based SHM system on the Los Alamos National Laboratory blast tube. A blast tube experiment was modeled using the Abaqus explicit finite element solver. A custom user subroutine was written to apply test-like pressure loading to the inside surface of the blast tube. The subroutine applies analytically defined pressure loads derived from tracer output taken from a Compressible Flow Computational Fluid Dynamics Solver model of the blast tube. Five unique versions of the model were created: an undamaged reference model at 65°F was used as the baseline and compared to equivalent models at 10°F and 100°F. These three models were compared to models with small damage at the reference temperature. The two types of damage considered were a radial (circumferential) crack in the main tube body and a longitudinal crack in the supports. Acceleration outputs were extracted from accelerometer bodies included in the model and were post processed using a variety of standard SHM techniques. Different potential features signaling failure were extracted and compared using statistical methods in the time and frequency domains. A method was identified that clearly shows that differences in structural response resulting from the modeled damage can be differentiated from the structural response resulting from changing environmental conditions. However, the amount of damage applied to create observable differences in the accelerometer data was so large that simpler methods of damage detection would be more cost effective in locating damage.

42 ENGINEERING↗

8-Plate Multi-Resonant Coupling Using a Class-E 2 Power Converter for Misalignments in Capacitive Wireless Power Transfer

Misalignment is a common issue in wireless power transfer systems. It shifts the resonant frequency away from the operating frequency that affects the power flow and efficiency from the charging station to the load. This work proposes a novel capacitive wireless power transfer (CPT) using an 8-plate multi-resonant capacitive coupling to minimize the effect of misalignments. A single-active switch class-E 2 power converter is utilized to achieve multi-resonance through the selection of different resonant inductors. Simulations show a widening of the resonant frequency band which offers better performance than a regular 4-plate capacitive coupling for misalignments. The hardware results of the 8-plate multi-resonant coupling show an efficiency of 88.5% for the 20.8 W test, which is 18.3% higher than that of the regular 4-plate coupling. Because of the wider resonant frequency band {455–485 kHz}, compared with the regular 4-plate coupling, the proposed design minimized the output voltage drop by 15% for a 10% misalignment. Even for large misalignments, the 8-plate performance improved by 40% compared with the 4-plate coupling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal Design of Intensified Towers for CO2 Capture with Internal, Printed Heat Exchangers

Solvent-based carbon capture processes typically suffer from the temperature rise of the solvent due to the heat of absorption of CO2. This increased temperature is not thermodynamically favor-able and results in a significant reduction in performance in the absorber column. As opposed to interstage coolers, which only remove, cool, and return the solvent at discrete locations in the column, internal coolers that are integrated with the packing can cool the process inline, which can result in improved efficiency. This work presents the modeling of these internal coolers within an existing generic, equation-oriented absorber column model that can cool the process while allowing for simultaneous mass transfer. Optimization of this model is also performed, which is capable of optimally choosing the best locations to place these devices, such that heat removal and mass transfer area are balanced. Results of the optimization have shown that optimally placed cooling elements result in a significant increase in the capture efficiency of the process, compared to a similar column with no internal cooling, with a common trend being the cooling of the column in the temperature bulge region. It is observed that by optimally placing an internal cooler, the solvent flow rate can be decreased, and the CO2 lean loading can be increased while still maintaining the same efficiency. These process changes can lead to a substantial reduction in costs due to lower reboiler duty.

Summits, Stephen↗

Preliminary design of an auxiliary power unit for the space shuttle. Volume 1: Summary

Numerous candidate APU concepts are considered, each meeting the space shuttle APU problem statement. Evaluation of these concepts indicates that the optimum concept is a hydrogen-oxygen APU incorporating a recuperator to utilize the exhaust energy and using the cycle hydrogen flow as a means of cooling the component heat loads. A preliminary design of the selected APU concept is presented, placing primary emphasis on the cycle thermal management and the controls. Results for both steady state and transient APU performance are also included, based on digital computer programs developed during the study. The selected APU provides up to 400 hp out of the gearbox, has a fixed weight of about 277 lb, and requires about 2 lb/shp-hr of propellants.

Hamilton, M. L.↗