Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LUMINESCENCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Ultraviolet Testing of Space Suit Materials for Mars

Human missions to Mars may require radical changes in the approach to extra-vehicular (EVA) suit design. A major challenge is the balance of building a suit robust enough to complete multiple EVAs under intense ultraviolet (UV) light exposure without losing mechanical strength or compromising the suit's mobility. To study how the materials degrade on Mars in-situ, the Jet Propulsion Laboratory (JPL) invited the Advanced Space Suit team at NASA's Johnson Space Center (JSC) to place space suit materials on the Scanning Habitable Environments with Raman & Luminescence for Organics and Chemicals (SHERLOC) instrument's calibration target of the Mars 2020 rover. In order to select materials for the rover and understand the effects from Mars equivalent UV exposure, JSC conducted ground testing on both current and new space suit materials when exposed to 2500 hours of Mars mission equivalent UV. To complete this testing, JSC partnered with NASA's Marshall Space Flight Center to utilize their UV vacuum chambers. Materials tested were Orthofabric, polycarbonate, Teflon, Dacron, Vectran, spectra, bladder, nGimat coated Teflon, and nGimat coated Orthofabric. All samples were measured for mass, tensile strength, and chemical composition before and after radiation. Mass loss was insignificant (less than 0.5%) among the materials. Most materials loss tensile strength after radiation and became more brittle with a loss of elongation. Changes in chemical composition were seen in all radiated materials through Spectral Analysis. Results from this testing helped select the materials that will fly on the Mars 2020 rover. In addition, JSC can use this data to create a correlation to the chemical changes after radiation-which is what the rover will send back while on Mars-to the mechanical changes, such as tensile strength.

Larson, Kristine↗

Lessons from Astrobiological Planetary Analogue Exploration in Iceland: Biomarker Assay Performance and Downselection

Understanding the sensitivity of biomarker assays to the local physicochemical environment, and the underlying spatial distribution of the target biomarkers in 'homogeneous' environments, can increase mission science return. We have conducted four expeditions to Icelandic Mars analogue sites in which an increasingly refined battery of physicochemical measurements and biomarker assays were performed, staggered with scouting of further sites. Completed expeditions took place in 2012 (location scouting and field assay use testing), 2013 (sampling of two major sites with three assays and observational physicochemical measurements), 2015 (repeat sampling of prior sites and one new site, scouting of new sites, three assays and three instruments), and 2016 (preliminary sampling of new sites with analysis of returned samples). Target sites were geologically recent basaltic lava flows, and sample loci were arranged in hierarchically nested grids at 10 cm, 1 m, 10 m, 100 m, and >1 km order scales, subject to field constraints. Assays were intended to represent a diversity of potential biomarker types (cell counting via nucleic acid staining and fluorescence microscopy, ATP quantification via luciferase luminescence, and relative DNA quantification with simple domain-level primers) rather a specific mission science target, and were selected to reduce laboratory overhead, require limited consumables, and allow rapid turnaround. All analytical work was performed in situ or in a field laboratory within a day's travel of the field sites unless otherwise noted. We have demonstrated the feasibility of performing ATP quantification and qPCR analysis in a field-based laboratory with single-day turnaround. The ATP assay was generally robust and reliable and required minimal field equipment and training to produce a large amount of useful data. DNA was successfully extracted from all samples, but the serial-batch nature of qPCR significantly limited the number of primers (hence classifications) and replicates that could be run in a single day. Fluorescence microscopy did not prove feasible under the same constraints, primarily due to the large number of person-hours required to view, analyze, and record results from the images; however, this could be mitigated with higher-quality imaging instruments and appropriate image analysis software.

Planetary↗

Mars 2020 Rover SHERLOC Calibration Target

The Scanning Habitable Environments with Raman & Luminescence for Organics & Chemicals (SHERLOC) instrument is a deep ultraviolet (UV) Raman Fluorescence instrument selected as part of the Mars 2020 rover instrument suite. SHERLOC will be mounted on the rover arm and its primary role is to identify carbonaceous species in martian samples. The SHERLOC instrument requires a calibration target which is being designed and fabricated at JSC as part of our continued science participation in Mars robotic missions. The SHERLOC calibration target will address a wide range of NASA goals to include basic science of interest to both the Science Mission Directorate and Human Exploration and Operations Mission Directorate.

Graff, Trevor↗

Flow Structure Comparison for Two 7-Point LDI Configurations

This paper presents a comparison primarily of the 2-D velocity profiles in the non-burning system; and for the luminescent flame structure for a 7-point Lean Direct Injector (LDI). This circular LDI array consists of a center element surrounded by six outer elements spaced 60 degrees apart; the spacing between all adjacent elements is the same. Each element consists of simplex atomizer that injects at the throat of a converging-diverging venturi, and an axial swirler upstream of the venturi throat to generate swirl. The two configurations were: 1) one which consists of all 60 co-swirling axial air swirlers, and; 2) one configuration which uses a 60 swirler in the center, surrounded by counter-swirling 45 swirlers. Testing was done at 5 atm and an inlet temperature of 800F. Two air reference velocities were considered in the cold flow measurements and one common air flow condition for the burning case.The 2D velocity profiles were determined using particle image velocimetry and the flame structure was determined using high speed photography.

velocity↗

Environmental Testing of Tritium-Phosphor Glass Vials for Use in Long-Life Radioisotope Power Conversion Units

Power generation in extreme environments, such as the outer solar system, the night side of planets, or other low-illumination environments, currently presents a technology gap that challenges NASA's ambitious scientific goals. We are developing a radioisotope power cell (RPC) that utilizes commercially available tritium light sources and standard 1.85 eV InGaP2 photovoltaic cells to convert beta particle energy to electric energy. In the test program described here, we perform environmental tests on commercially available borosilicate glass vials internally coated with a ZnS luminescent phosphor that are designed to contain gaseous tritium in our proposed power source. Such testing is necessary to ensure that the glass containing the radioactive tritium is capable of withstanding the extreme environments of launch and space for extended periods of time.

Zemcov, Michael↗

Sensor Integrated Pilot Mask for On-Board, Real-Time, Monitoring of Pilot Breathing Gas

A pilot's job is unique in the demands it places on the human body, and many conditions can seriously affect pilot performance, threatening mission completion and pilot safety. The gas in a flight mask contains key indicators of the pilot's physiological state, including oxygen inhaled and carbon dioxide exhaled, which can signal hypoxia, hyperoxia, hypocapnia, and hypercapnia. A fiber optic-based sensor system, integrated into the pilot mask, has been developed to monitor in real time, during flight, the pilot breathing gas levels. Monitoring the partial pressure of oxygen and carbon dioxide in the pilot mask supports real-time closed loop control of the on-board oxygen generation system, based on a direct reading of what the pilot is actually breathing. The pilot Mask Sensor (MASES) system incorporates luminescence sensors for pO2, pCO2, relative humidity, pressure, and temperature in a compact probe in the pilot mask; it is based on sensor technology developed for gas monitoring in space suit systems, in work supported by NASA under the Small Business Innovation Research program. Relevant requirements for the MASES system include sensor operation while wet, operation at reduced pressure, ability to withstand rapid decompression, operation in a pure oxygen atmosphere, low power consumption, a compact readout unit, and flexible miniature sensors; many of these requirements are shared with gas monitors in space suits. Data are presented from tests conducted with human subjects in an altitude chamber and in a centrifuge.

Delgado Alonso, Jesus↗

Mid-infrared Spectroscopy of Pr-Doped Materials

Solid state lanthanide doped lasers primarily operate in the ultraviolet, visible, near infrared and short-wavelength infrared out to around 2.1 μm. At longer wavelengths, the transitions in conventional oxide crystal and glass materials become susceptible to multiphonon quenching due to their relatively large phonon energy. The use of low phonon materials can minimize the nonradiative quenching, opening up possibilities for solid state lanthanide lasers operating in the mid-infrared (MIR). This provides motivation to study the spectroscopy of lanthanide ions in bromide, chloride and fluoride materials, which have relatively low phonon energies. In this article, the MIR spectroscopy or praseodymium ions in five different host materials is studied, specifically KPb2Br5 (KPB), LaF3, KYF4 (KYF), BaY2F8 (BYF) and YLiF4 (YLF) host crystals. The MIR emission cross sections have been measured from 3 to 6 μm and reciprocity of absorption and emission is utilized to validate the results. The lifetime dynamics in the MIR are covered for various pump and emission wavelengths. Results are also presented on MIR emission from 6.5 to 8.5 μm in a Pr: KPB crystal, which, to the best of the authors knowledge, is the first such measurement of luminescence in this wavelength range that has been published.

Brian M Walsh↗

Effect of Electronic Shot Noise on Dynamic Measurements using Optical Techniques: Examples from Rayleigh Scattering and Unsteady PSP

Electronic shot noise is an unavoidable reality in all optical techniques that depend on measuring light intensity. For steady-state, time-averaged measurements the impact of shot noise can be easily reduced by increasing the exposure time, or by averaging over multiple-exposures. That is not the case for unsteady measurements, where time histories of light intensity variations need to be created either by high-speed photography (unsteady PSP) or via photoelectron counting (spectrally resolved Rayleigh scattering) over short time durations using a photo-multiplier tube (PMT) and photon counting electronics. Electronic shot noise introduces a fixed amount of random error, which can overwhelm the light intensity variation caused by turbulent fluctuations. Spectrum computed from such time series shows a fixed noise floor that is independent of the number of data points in the time series. For a fixed optical system, where the collected power of the luminescent light (uPSP), or the scattered light (Rayleigh) is fixed, one needs to resort to special techniques to obtain enough signal-to noise ratio (SNR). For the uPSP application it is shown that averaging of the adjacent pixels improves SNR; although this may lead to a sacrifice of spatial resolution. A second means is to increase the exposure time, which leads to a lowering of the frequency range. For the Rayleigh application, improvements of SNR can be achieved via two different cross-correlation based approaches. The first involves measuring the light intensity using two PMTs using short, contiguous gates; thereby, creating two time-series of data. The second one involves collecting one long time-series of data using one set of measurement device, followed by an odd-even splitting into two time series. When the two time-series are cross-correlated, and a power spectrum is calculated, a significant reduction in the shot noise floor can be achieved. Examples from measurements of density and velocity fluctuations spectra from two different Rayleigh setup are presented to demonstrate the process.

uPSP↗

An Overview of SHERLOC Raman and Fluorescence Spectroscopy Results Obtained During Perseverance’s Green Zone Campaign at Jezero Crater, Mars

The Perseverance rover landed in Jezero crater, Mars, in February 2021. The field site was chosen because orbiter data provided evidence that the crater hosted an ancient (>2.7 Ga) fluvio-lacustrine environment. The Octavia E. Butler landing site is located ~1.9 km east of the erosional remnant of the Jezero river delta. Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) is an arm-mounted instrument that combines fluorescence and Raman spectroscopy with microscopic imaging to analyze geological materials in order to better understand the history of the environments recorded in the rocks within Jezero crater and to search for potential biosignatures. SHERLOC has two microscopic cameras, the Autofocus and Context Imager (ACI) and the Wide-Angle Topographic Sensor for Operations and eNgineering, (WATSON). These subsystems obtain high spatial resolution (10.1–100 µm/pixel) images to identify grain-scale structure and texture. SHERLOC spectroscopy enables high-sensitivity detection, characterization, and spatially-resolved correlation of trace organic materials. SHERLOC’s 248.6 nm deep UV laser generates a 100 µm-diameter spot. Photons generated by Raman scattering and fluorescence emission are collected and the spectra are downlinked to Earth for analysis. Knowledge of where the laser is pointed allows for mineral and compositional maps to be generated and overlain in ACI and WATSON images. Early spectroscopy observations focused on natural rock surfaces at targets named Nataani (sol 83), Bi_la_sana (sol 98) and Foux (sol 141). These surfaces included patches of aeolian dust that had settled upon the rocks. Perseverance’s abrasion tool is expected to become available in August 2021; it will grind to depths of 14 mm to remove dust and penetrate coatings and weathering rinds. This presentation will summarize major results from analysis of the rocks examined by SHERLOC during Perseverance’s first science and sample coring campaign (Green Zone Campaign).

Luther W Beegle↗

Calibration and Validation of the SHERLOC Instrument Operating in Jezero Crater, Mars

The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemistry (SHERLOC) is an instrument onboard the Mars 2020 Perseverance rover. It consists of a spectrometer that measures deep ultraviolet (DUV) resonance Raman and native fluorescence photons generated through surface interactions with a 248.6 nm pulsed laser. Two microscopic imagers, the Autofocus Context Imager (ACI) and the Wide-Angle Topographic Sensor for Operations and eNgineering (WATSON), provide high-resolution context images of SHERLOC targets. The ACI is co-boresighted with the spectrometer. To ensure proper calibration, the SHERLOC calibration target (SCT) is mounted on the front of the rover and consists of ten different materials. The SCT was designed, fabricated, assembled, and tested by Jacobs Technology, Inc., and NASA Johnson Space Center. The dimensions of the calibration target housing are 150 x 89 x 33 mm and it weighs ~437 g. The ten targets are arranged in two rows; the first six are hard targets (AlGaN for Raman and fluorescence, diffuse transmission target, a slice of the SaU008 Mars meteorite, an intensity maze, and polycarbonate over geocache coin) and the remaining four are soft-goods targets (Vectran, Ortho-Fabric, Teflon, and nGimat-coated Teflon). The hard targets calibrate the spectrometer’s Raman and fluorescence spectral accuracy, ambient light reflection, and Raman response curve, while the soft-goods targets are spacesuit materials that function as human exploration targets, some of which are also used for spectral calibration. SHERLOC also has an internal calibration target consisting of AlGaN on sapphire (275 nm) located inside the ACI opaque dust cover to ensure proper instrument functioning between calibration target analyses. Initial SHERLOC, ACI, and WATSON calibration and validation on Mars was performed using the internal calibration target on sols 59, 83, 98, and 141; WATSON imaging of the SCT on sols 26 and 62, and SHERLOC spectroscopy and ACI imaging of the SCT on sol 59. These early data provide initial insights into instrument performance and the stability and degradation of the calibration target materials relative to the Martian surface and dust environment. Early observations also have implications for future astronaut spacesuit materials.

Trevor G Graff↗

Exploring rock-regolith interfaces in Jezero crater with Mars 2020 SHERLOC

The Perseverance rover successfully landed in Jezero crater, Mars in February 2021 at the Octavia E. Butler landing site and began its mission to explore and sample an ancient crater lake basin. Principal goals of the Mars 2020 mission include characterizing the geology of Mars and seeking signs of ancient microbial life via the spacecraft cameras and spectroscopic instruments onboard. The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) instrument is a deep UV Raman spectrometer that utilizes a 248.6nm pulsed laser. Part of SHERLOC is a color camera known as the Wide Angle Topographic Sensor for Operations and eNgineering (WATSON). The SHERLOC suite provides coordinated, spectroscopic and imaging capabilities at high spatial resolution, to detect minerals and organic molecules in microtextural context. By pairing high spatial resolution (~100 μm) resonance Raman and native fluorescence spectroscopy with microscopic imaging in a novel spacecraft capability, SHERLOC enables texture-specific molecular composition measurements of rock and regolith targets on Mars. Coordinated rock-regolith observations illuminate unique insights into weathering processes and thereby to primary properties of rocks in Jezero crater. This work describes the potential of rock-regolith interfaces to preserve unique records of geological processes in Jezero crater and can powerfully supplement observations of the more general rock record on Mars. Linking observations of local rock texture with associated regolith reveals important lithologic information based on the interrelationship between differential weathering behavior and mineralogy, grain size, and cement chemistry. Preliminary observations indicate that the polygonally fractured lithotype common near the Octavia E. Butler landing site may weather by granular disintegration and/or surface creep, a relation that can be uniquely observed at the rock-regolith interface. SHERLOC -specific observations of microtextural and elemental composition transitions presented here trace rock-regolith boundaries at multiple indurated surfaces adjacent to regolith. At these locales, grain-scale based examinations suggest chemical weathering could be related to a variably distributed coating or rind on dark rock targets that may be mafic in composition. Granule deposits overlying widely distributed fine-grained material are also observable. Mineral identifications of each phase are presented, with cross-scale comparisons to the remote insights gained by the SuperCam instrument.

Emily L. Cardarelli↗

Implications of Deep UV Raman Spectra of Gypsum and Fe-Bearing Dust Mixtures for Gypsum Detectability by the SHERLOC M2020 Instrument

Key science objectives of the Mars2020 Scanning Habitable Environments with Raman & Luminescence for Organics & Chemicals (SHERLOC) instrument suite include identification and characterization of inorganic and bio-logic phases and investigation of the past habitability of Jezero crater [1, 2]. To fully interpret in situ data received from SHERLOC, databases of deep ultraviolet (DUV) Raman spectra from a wide variety of martian analogue materials are being developed by us and others [e.g., 3]. Ferrous and ferric iron are abundant on the martian surface in bas-alt and, depending on alteration and transport processes, its alteration products. Fe-bearing phases are important to characterize with respect to detect-ability by DUV Raman spectroscopy because they strongly absorb DUV radiation, thereby decreasing Raman peak intensity [3, 4]. Ca-sulfates and Fe-bearing minerals have been commonly detected on the martian surface [5, 6]. In this analogue study, we collected Raman spectra of mechanical mixtures of powders of hematite HMS3 (~120 nm discrete particle diameter [7]), palagonite HWMK919 (<5 μm size fraction [8]) and gypsum WD163 (<150 μm size fraction) t o ex-amine the detectability of gypsum in the presence of relatively finer-grained, Fe bearing material. Be-cause of the difference in particle diameters, hematite and palagonite powders act as surrogates for martian dust, coating at small concentrations and then enveloping larger gypsum particles.

N C Haney↗

Relative Detectability of Iron-Bearing Phases for the Mars 2020 Sherloc Deep UV Raman Instrument: 1. Focusing on Carbonates

A deep ultraviolet (DUV) Raman and fluorescence instrument is a surface standoff instrument mounted on the robotic arm of the Mars 2020 (M2020) rover Perseverance, and it is a key element of the Scanning Habitable Environments with Luminescence for Organics and Chemicals (SHERLOC) investigation [1]. Measurement and science objectives include mineralogical and organic images (~100 μm/pixel) that map sub-millimeter spatial distributions and characterization of primary and secondary minerals, potential organics, and their interaction/alteration products. The results of data analysis pertain to understanding igneous and alteration processes on Mars through time, assessing habitability, evidencing in situ biosignatures, and, along with results from other Perseverance instruments, selecting samples to cache for Mars sample return. Acceptance of the SHERLOC investigation for the NASA M2020 mission [2] created a need for Mars-relevant DUV Raman spectra, particularly for inorganic materials [e.g., 3, 4]. As reported previously [e.g., 4, 5], phases with Fe cations as essential elements (e.g., siderite (FeCO3) and ankerite (FeCa(CO3)2) for carbonates) significantly hinder detection by DUV Raman because of intense absorption of incident and scattered DUV laser radiation by Fe cations. We report here the relative detectability of carbonates (Mg,Ca,Fe,Mn)CO3 by DUV Raman using a SHERLOC analog laboratory instrument.

R V Morris↗

Calibration of the SHERLOC Deep Ultraviolet Fluorescence–Raman Spectrometer on the Perseverance Rover

We describe the wavelength calibration of the spectrometer for the scanning of habitable environments with Raman and luminescence for organics and chemicals (SHERLOC) instrument onboard NASA’s Perseverance Rover. SHERLOC utilizes deep ultraviolet Raman and fluorescence (DUV R/F) spectroscopy to enable analysis of samples from the Martian surface. SHERLOC employs a 248.6 nm deep ultraviolet laser to generate Raman-scattered photons and native fluorescence emission photons from near-surface material to detect and classify chemical and mineralogical compositions. The collected photons are focused on a charge-coupled device and the data are returned to Earth for analysis. The compact DUV R/F spectrometer has a spectral range from 249.9 nm to 353.6 nm (200 cm1 to 12, 000 cm1) (with a spectral resolution of 0.296 nm (40 cm1)). The compact spectrometer uses a custom design to project a high-resolution Raman spectrum and a low-resolution fluorescence spectrum on a single charge-coupled device. The natural spectral separation enabled by deep ultraviolet excitation enables wavelength separation of the Raman/fluorescence spectra. The SHERLOC spectrometer was designed to optimize the resolution of the Raman spectral region and the wavelength range of the fluorescence region. The resulting illumination on the charge-coupled device is curved, requiring a segmented, nonlinear wavelength calibration in order to understand the mineralogy and chemistry of Martian materials.

Kyle Uckert↗

The first 300 sols of the SHERLOC investigation on the Mars 2020 rover

The Mars2020 mission is NASA’s latest flagship mission to Mars. The spacecraft launched in July 2020, and landed in Jezero crater on February 18, 2021 at the Octavia Butler Landing site. The rocks and sediments of Jezero crater have been argued to have preserved records of past, potentially habitable environments. The mission is characterizing the field site by analyzing chemistry, looking for organics and searching for potential biosignatures. The Scanning Habitable Environments with Ra-man and Luminescence for Organics and Chemicals (SHERLOC) is a robotic arm mounted instrument. SHERLOC combines imaging with UV resonance Raman and native deep UV fluorescence spectroscopy to identify potential biosignatures and understand the aqueous history of the Jezero Region. WATSON (Wide Angle Topographic Sensor for Operations and eNgineering), a refight of the Mars Hand Lens Imager (MAHLI) on the Curiosity rover is capable of color imaging over a wide range of resolutions (from infinity to 13.1 micron/pixel) and is used for both science and engineering. A second imager, the Autofocusing Con-textual Imager (ACI), produces gray scale images at 10.1 micron/pixel resolution at a 48 mm range.

A. E. Murphy↗

SHERLOC Investigations at the Máaz and Séítah formations within Jezero crater

Introduction: The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) instrument combines microscopic imaging, native fluorescence and Raman spectroscopy to better understand the mineral and chemical makeup of rocks on the martian surface. Native fluorescence emissions from aromatic organic species allow for detection and classification of aromatic organic molecules, whereas Raman scattered photons from molecules allow identification of functional groups of organics, chemicals, and minerals. These signatures are obtained on a 100 micron spatial scale and collocated to images so textures, minerals and chemicals can all be compared [1]. Results: SHERLOC has been operating on Mars since February 18, 2021. As of this writing, we have analyzed 3 natural surfaces, and 5 abraded rock patches created during the Crater Floor Campaign within Jezero crater [2]. The Guillaumes target (from the Roubion outcrop, Roubion member of the Máaz Formation) is dominated by Ca-sulfate with patches of perchlorate. The Bellegarde target (from the Rochette outcrop, Rochette member of the Máaz Formation) exhibits Raman peaks that match hydrated Ca-sulfate, amorphous/microcrystalline silicate (AMS), carbonate, and phosphate phases. A fluorescence doublet at ~305 and ~325 nm was detected and is most likely due to indigenous organic material in the sample. The Garde target (from the Bastide outcrop, Bastide member of the Séítah Formation) is dominated by olivine and carbonate with AMS occurring across the material. The Dourbes target (from the Brac outcrop, Bastide member of the Séítah Formation) is dominated by olivine and shows minor amounts of carbonate, hydrated Ca-sulfate, and AMS. The Quartier target exhibits a large sulfate feature, as well as carbonate, perchlorate, olivine and a fluorescence doublet at 305 and 325 nm and is very similar to that observed at Bellegarde. In each of these samples we have identified fluorescence features that are likely aromatic organics native to the rock interiors. Acknowledgments: This work was carried out at the Jet Propulsion Laboratory, The California Institute of Technology under a contract from NASA.

L W Beegle↗

The Mars 2020 Watson Imaging Subsystem of the Sherloc Investigation and Anticpated Early Results

In February 2021, the Mars 2020 Perseverance rover is anticipated to touch down in Jezero crater, Mars. Perseverance is unique in that it will conduct in situ science as well as cache samples for eventual return to Earth for analysis in terrestrial laboratories. It will explore the geologic setting within Jezero over a range of scales in order to address fundamental questions about the evolution of Mars and assess whether there is evidence of past or present Martian life. The Wide Angle Topographic Sensor for Operations and eNgineering (WATSON), one of two imaging subsystems within the Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) instrument[1,2], acquires images that support scientific study of Jezero crater and sample acquisition, as well as rover and instrument operations(Fig. 1).WATSON serves a number of roles; it 1) provides color context imaging of SHERLOC and Planetary Instrument for X-Ray Litho chemistry (PIXL)analysis locations, placing the spatial distribution of organics and mineralogy detected by SHERLOC and the elemental maps generated by PIXL within the context of rock texture and structure; 2)acquires stand-alone observations of rock structures and textures from the outcrop to the grain scale; and 3)images rover components and other instruments to monitor their health and condition. We plan to present images acquired within the first ~30 sols of operations.

M E Minitti↗

SHERLOC: Results of the first 350 sols of operations

On February 18th 2021, the Perseverance rover landed in Jezero crater, Mars. This site was chosen because orbiter data analysis provides evidence that the crater hosted a stream-fed lake during the Martian Noachian period. The Octavia Butler landing site is located ~1.9 km east of the remnants of a river delta. Deltaic and lacustrine sediments can preserve biosignatures, making Jezero crater a prime target for Mars sample return science. One of the seven instruments on Perseverance’s science payload is SHERLOC –Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals. SHERLOC combines fluorescence and Raman spectroscopy with microscopic imaging to analyze surface material to better understand the history of the aqueous environments recorded in the rocks of Jezero crater and to search for potential biosignatures. SHERLOC imaging obtains high spatial resolution images of geological targets to identify grain-scale structure and texture. SHERLOC spectroscopy enables high-sensitivity detection, characterization, and spatially resolved correlation of trace organic materials. Native fluorescence emissions from aromatic organic species allow for detection and classification of aromatic organic molecules, whereas Raman scattered photons from molecules allow identification of functional groups of organics, chemicals, and minerals. In the first 300 sols, SHERLOC has analyzed 3 natural surfaces, and 5 abraded rock patches created during the Crater Floor Campaign within Jezero crater. SHERLOC has been able to identify phosphates, amorphous/microcrystalline silicate (AMS), olivine, sulfates, and carbonates in abraded patches in the green zone campaign within Jezero Crater Máaz and Séítah formations. Within these detections we have begun to tell the story of what this crater was like when it was full of liquid water over 3 billion years ago. In each of these samples we have identified fluorescence features that are likely aromatic organics native to the rock interiors. We have identified multiple unique fluorescence signatures, within each of the abraded patches. The organic signatures have either been widely distributed over an extended area, which is probably due to planetary wide dust, or have spatially resolved locations that are collocated with different mineral signatures. Note: Additional information available on attachment.

L. W. Beegle↗