Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image processing.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Localizing intracavitary brachytherapy applicators from cone-beam CT x-ray projections via a novel iterative forward projection matching algorithm

Purpose: To present a novel method for reconstructing the 3D pose (position and orientation) of radio-opaque applicators of known but arbitrary shape from a small set of 2D x-ray projections in support of intraoperative brachytherapy planning. Methods: The generalized iterative forward projection matching (gIFPM) algorithm finds the six degree-of-freedom pose of an arbitrary rigid object by minimizing the sum-of-squared-intensity differences (SSQD) between the computed and experimentally acquired autosegmented projection of the objects. Starting with an initial estimate of the object's pose, gIFPM iteratively refines the pose parameters (3D position and three Euler angles) until the SSQD converges. The object, here specialized to a Fletcher-Weeks intracavitary brachytherapy (ICB) applicator, is represented by a fine mesh of discrete points derived from complex combinatorial geometric models of the actual applicators. Three pairs of computed and measured projection images with known imaging geometry are used. Projection images of an intrauterine tandem and colpostats were acquired from an ACUITY cone-beam CT digital simulator. An image postprocessing step was performed to create blurred binary applicators only images. To quantify gIFPM accuracy, the reconstructed 3D pose of the applicator model was forward projected and overlaid with the measured images and empirically calculated the nearest-neighbor applicator positional difference for each image pair. Results: In the numerical simulations, the tandem and colpostats positions (x,y,z) and orientations ({alpha},{beta},{gamma}) were estimated with accuracies of 0.6 mm and 2 deg., respectively. For experimentally acquired images of actual applicators, the residual 2D registration error was less than 1.8 mm for each image pair, corresponding to about 1 mm positioning accuracy at isocenter, with a total computation time of less than 1.5 min on a 1 GHz processor. Conclusions: This work describes a novel, accurate, fast, and completely automatic method to localize radio-opaque applicators of arbitrary shape from measured 2D x-ray projections. The results demonstrate {approx}1 mm accuracy while compared against the measured applicator projections. No lateral film is needed. By localizing the applicator internal structure as well as radioactive sources, the effect of intra-applicator and interapplicator attenuation can be included in the resultant dose calculations. Further validation tests using clinically acquired tandem and colpostats images will be performed for the accurate and robust applicator/sources localization in ICB patients.

60 APPLIED LIFE SCIENCES↗

Noise-resolution tradeoffs in x-ray CT imaging: A comparison of penalized alternating minimization and filtered backprojection algorithms

Purpose: In comparison with conventional filtered backprojection (FBP) algorithms for x-ray computed tomography (CT) image reconstruction, statistical algorithms directly incorporate the random nature of the data and do not assume CT data are linear, noiseless functions of the attenuation line integral. Thus, it has been hypothesized that statistical image reconstruction may support a more favorable tradeoff than FBP between image noise and spatial resolution in dose-limited applications. The purpose of this study is to evaluate the noise-resolution tradeoff for the alternating minimization (AM) algorithm regularized using a nonquadratic penalty function. Methods: Idealized monoenergetic CT projection data with Poisson noise were simulated for two phantoms with inserts of varying contrast (7%-238%) and distance from the field-of-view (FOV) center (2-6.5 cm). Images were reconstructed for the simulated projection data by the FBP algorithm and two penalty function parameter values of the penalized AM algorithm. Each algorithm was run with a range of smoothing strengths to allow quantification of the noise-resolution tradeoff curve. Image noise is quantified as the standard deviation in the water background around each contrast insert. Modulation transfer functions (MTFs) were calculated from six-parameter model fits to oversampled edge-spread functions defined by the circular contrast-insert edges as a metric of local resolution. The integral of the MTF up to 0.5 lp/mm was adopted as a single-parameter measure of local spatial resolution. Results: The penalized AM algorithm noise-resolution tradeoff curve was always more favorable than that of the FBP algorithm. While resolution and noise are found to vary as a function of distance from the FOV center differently for the two algorithms, the ratio of noises when matching the resolution metric is relatively uniform over the image. The ratio of AM-to-FBP image variances, a predictor of dose-reduction potential, was strongly dependent on the shape of the AM's nonquadratic penalty function and was also strongly influenced by the contrast of the insert for which resolution is quantified. Dose-reduction potential, reported here as the fraction (%) of FBP dose necessary for AM to reconstruct an image with comparable noise and resolution, for one penalty parameter value of the AM algorithm was found to vary from 70% to 50% for low-contrast and high-contrast structures, respectively, and from 70% to 10% for the second AM penalty parameter value. However, the second penalty, AM-700, was found to suffer from poor low-contrast resolution when matching the high-contrast resolution metric with FBP. Conclusions: The results of this simulation study imply that penalized AM has the potential to reconstruct images with similar noise and resolution using a fraction (10%-70%) of the FBP dose. However, this dose-reduction potential depends strongly on the AM penalty parameter and the contrast magnitude of the structures of interest. In addition, the authors' results imply that the advantage of AM can be maximized by optimizing the nonquadratic penalty function to the specific imaging task of interest. Future work will extend the methods used here to quantify noise and resolution in images reconstructed from real CT data.

60 APPLIED LIFE SCIENCES↗

Objective characterization of GE Discovery CT750 HD scanner: Gemstone spectral imaging mode

Purpose: To objectively characterize the performance of the gemstone spectral imaging (GSI) mode of GE CT750 HD scanner from a user's perspective. Methods: A regular scan protocol that approximates the adult abdomen scan protocol frequently used in the authors' institute was selected as the baseline, and a GSI protocol (preset 11) that is similar to the regular protocol and has a moderate dose level (CTDI{sub vol}=26.27 mGy) was compared to the baseline protocol. The resolving power of both protocols was characterized in terms of modulation transfer functions and high contrast resolution bar readings. Their noise characteristics were studied through noise power spectra, and their low contrast detectability was compared via contrast-to-noise ratio. Material decomposition capability of GSI was evaluated by scanning iodine solutions of 9-24 mg/ml iodine concentration in a Gammex CT phantom and by examining the estimated iodine concentration. In addition, a formula describing the dependency of HU in iodine enhanced area on GSI monochromatic energies and iodine concentrations was provided and the theoretical values were compared with the measured results. Results: The resolutions levels of 50%, 10%, and 5% MTF of GSI monochromatic images at 65 keV agree with those of the regular protocol within 0.1 lp/cm. GSI monochromatic images at 65 keV demonstrated the lowest noise level among GSI images of different monochromatic energies and showed very similar noise magnitude and noise power distribution as compared to the regular protocol images. The CNR of 60 and 65 keV GSI monoimages are approximately 100% of those of the regular protocol images. Estimated iodine concentration levels agreed with the actual values within 2% when the iodine solutions were placed at 3, 9, 12 o'clock positions of the phantom; when iodine solutions were placed at the phantom center and at 6 o'clock position, higher discrepancies of 2%-10% were observed. The observed dependency of HU on keV and iodine concentration levels agreed with the expectation from x-ray attenuations. Conclusions: Equivalent performances were observed in the comparison between GSI 65 keV monochromatic images and images from a regular abdomen scan protocol. This suggests the possibility of GSI to be employed in routine abdominal scans, which would potentially offer more information through its capabilities of material decomposition.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation for 2D/3D registration I: A new gold standard data set

Purpose: In this article, the authors propose a new gold standard data set for the validation of two-dimensional/three-dimensional (2D/3D) and 3D/3D image registration algorithms. Methods: A gold standard data set was produced using a fresh cadaver pig head with attached fiducial markers. The authors used several imaging modalities common in diagnostic imaging or radiotherapy, which include 64-slice computed tomography (CT), magnetic resonance imaging using Tl, T2, and proton density sequences, and cone beam CT imaging data. Radiographic data were acquired using kilovoltage and megavoltage imaging techniques. The image information reflects both anatomy and reliable fiducial marker information and improves over existing data sets by the level of anatomical detail, image data quality, and soft-tissue content. The markers on the 3D and 2D image data were segmented using ANALYZE 10.0 (AnalyzeDirect, Inc., Kansas City, KN) and an in-house software. Results: The projection distance errors and the expected target registration errors over all the image data sets were found to be less than 2.71 and 1.88 mm, respectively. Conclusions: The gold standard data set, obtained with state-of-the-art imaging technology, has the potential to improve the validation of 2D/3D and 3D/3D registration algorithms for image guided therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation for 2D/3D registration II: The comparison of intensity- and gradient-based merit functions using a new gold standard data set

Purpose: A new gold standard data set for validation of 2D/3D registration based on a porcine cadaver head with attached fiducial markers was presented in the first part of this article. The advantage of this new phantom is the large amount of soft tissue, which simulates realistic conditions for registration. This article tests the performance of intensity- and gradient-based algorithms for 2D/3D registration using the new phantom data set. Methods: Intensity-based methods with four merit functions, namely, cross correlation, rank correlation, correlation ratio, and mutual information (MI), and two gradient-based algorithms, the backprojection gradient-based (BGB) registration method and the reconstruction gradient-based (RGB) registration method, were compared. Four volumes consisting of CBCT with two fields of view, 64 slice multidetector CT, and magnetic resonance-T1 weighted images were registered to a pair of kV x-ray images and a pair of MV images. A standardized evaluation methodology was employed. Targets were evenly spread over the volumes and 250 starting positions of the 3D volumes with initial displacements of up to 25 mm from the gold standard position were calculated. After the registration, the displacement from the gold standard was retrieved and the root mean square (RMS), mean, and standard deviation mean target registration errors (mTREs) over 250 registrations were derived. Additionally, the following merit properties were computed: Accuracy, capture range, number of minima, risk of nonconvergence, and distinctiveness of optimum for better comparison of the robustness of each merit. Results: Among the merit functions used for the intensity-based method, MI reached the best accuracy with an RMS mTRE down to 1.30 mm. Furthermore, it was the only merit function that could accurately register the CT to the kV x rays with the presence of tissue deformation. As for the gradient-based methods, BGB and RGB methods achieved subvoxel accuracy (RMS mTRE down to 0.56 and 0.70 mm, respectively). Overall, gradient-based similarity measures were found to be substantially more accurate than intensity-based methods and could cope with soft tissue deformation and enabled also accurate registrations of the MR-T1 volume to the kV x-ray image. Conclusions: In this article, the authors demonstrate the usefulness of a new phantom image data set for the evaluation of 2D/3D registration methods, which featured soft tissue deformation. The author's evaluation shows that gradient-based methods are more accurate than intensity-based methods, especially when soft tissue deformation is present. However, the current nonoptimized implementations make them prohibitively slow for practical applications. On the other hand, the speed of the intensity-based method renders these more suitable for clinical use, while the accuracy is still competitive.

60 APPLIED LIFE SCIENCES↗

Deformable planning CT to cone-beam CT image registration in head-and-neck cancer

Purpose: The purpose of this work was to implement and validate a deformable CT to cone-beam computed tomography (CBCT) image registration method in head-and-neck cancer to eventually facilitate automatic target delineation on CBCT. Methods: Twelve head-and-neck cancer patients underwent a planning CT and weekly CBCT during the 5-7 week treatment period. The 12 planning CT images (moving images) of these patients were registered to their weekly CBCT images (fixed images) via the symmetric force Demons algorithm and using a multiresolution scheme. Histogram matching was used to compensate for the intensity difference between the two types of images. Using nine known anatomic points as registration targets, the accuracy of the registration was evaluated using the target registration error (TRE). In addition, region-of-interest (ROI) contours drawn on the planning CT were morphed to the CBCT images and the volume overlap index (VOI) between registered contours and manually delineated contours was evaluated. Results: The mean TRE value of the nine target points was less than 3.0 mm, the slice thickness of the planning CT. Of the 369 target points evaluated for registration accuracy, the average TRE value was 2.6{+-}0.6 mm. The mean TRE for bony tissue targets was 2.4{+-}0.2 mm, while the mean TRE for soft tissue targets was 2.8{+-}0.2 mm. The average VOI between the registered and manually delineated ROI contours was 76.2{+-}4.6%, which is consistent with that reported in previous studies. Conclusions: The authors have implemented and validated a deformable image registration method to register planning CT images to weekly CBCT images in head-and-neck cancer cases. The accuracy of the TRE values suggests that they can be used as a promising tool for automatic target delineation on CBCT.

60 APPLIED LIFE SCIENCES↗

A method for robust segmentation of arbitrarily shaped radiopaque structures in cone-beam CT projections

Purpose: Implanted markers are commonly used in radiotherapy for x-ray based target localization. The projected marker position in a series of cone-beam CT (CBCT) projections can be used to estimate the three dimensional (3D) target trajectory during the CBCT acquisition. This has important applications in tumor motion management such as motion inclusive, gating, and tumor tracking strategies. However, for irregularly shaped markers, reliable segmentation is challenged by large variations in the marker shape with projection angle. The purpose of this study was to develop a semiautomated method for robust and reliable segmentation of arbitrarily shaped radiopaque markers in CBCT projections. Methods: The segmentation method involved the following three steps: (1) Threshold based segmentation of the marker in three to six selected projections with large angular separation, good marker contrast, and uniform background; (2) construction of a 3D marker model by coalignment and backprojection of the threshold-based segmentations; and (3) construction of marker templates at all imaging angles by projection of the 3D model and use of these templates for template-based segmentation. The versatility of the segmentation method was demonstrated by segmentation of the following structures in the projections from two clinical CBCT scans: (1) Three linear fiducial markers (Visicoil) implanted in or near a lung tumor and (2) an artificial cardiac valve in a lung cancer patient. Results: Automatic marker segmentation was obtained in more than 99.9% of the cases. The segmentation failed in a few cases where the marker was either close to a structure of similar appearance or hidden behind a dense structure (data cable). Conclusions: A robust template-based method for segmentation of arbitrarily shaped radiopaque markers in CBCT projections was developed.

60 APPLIED LIFE SCIENCES↗

Epp: A C++ EGSnrc user code for x-ray imaging and scattering simulations

Purpose: Easy particle propagation (Epp) is a user code for the EGSnrc code package based on the C++ class library egspp. A main feature of egspp (and Epp) is the ability to use analytical objects to construct simulation geometries. The authors developed Epp to facilitate the simulation of x-ray imaging geometries, especially in the case of scatter studies. While direct use of egspp requires knowledge of C++, Epp requires no programming experience. Methods: Epp's features include calculation of dose deposited in a voxelized phantom and photon propagation to a user-defined imaging plane. Projection images of primary, single Rayleigh scattered, single Compton scattered, and multiple scattered photons may be generated. Epp input files can be nested, allowing for the construction of complex simulation geometries from more basic components. To demonstrate the imaging features of Epp, the authors simulate 38 keV x rays from a point source propagating through a water cylinder 12 cm in diameter, using both analytical and voxelized representations of the cylinder. The simulation generates projection images of primary and scattered photons at a user-defined imaging plane. The authors also simulate dose scoring in the voxelized version of the phantom in both Epp and DOSXYZnrc and examine the accuracy of Epp using the Kawrakow-Fippel test. Results: The results of the imaging simulations with Epp using voxelized and analytical descriptions of the water cylinder agree within 1%. The results of the Kawrakow-Fippel test suggest good agreement between Epp and DOSXYZnrc. Conclusions: Epp provides the user with useful features, including the ability to build complex geometries from simpler ones and the ability to generate images of scattered and primary photons. There is no inherent computational time saving arising from Epp, except for those arising from egspp's ability to use analytical representations of simulation geometries. Epp agrees with DOSXYZnrc in dose calculation, since they are both based on the well-validated standard EGSnrc radiation transport physics model.

60 APPLIED LIFE SCIENCES↗

Measurement of regional compliance using 4DCT images for assessment of radiation treatment

Purpose: Radiation-induced damage, such as inflammation and fibrosis, can compromise ventilation capability of local functional units (alveoli) of the lung. Ventilation function as measured with ventilation images, however, is often complicated by the underlying mechanical variations. The purpose of this study is to present a 4DCT-based method to measure the regional ventilation capability, namely, regional compliance, for the evaluation of radiation-induced lung damage. Methods: Six 4DCT images were investigated in this study: One previously used in the generation of a POPI model and the other five acquired at Henry Ford Health System. A tetrahedral geometrical model was created and scaled to encompass each of the 4DCT image domains. Image registrations were performed on each of the 4DCT images using a multiresolution Demons algorithm. The images at the end of exhalation were selected as a reference. Images at other exhalation phases were registered to the reference phase. For the POPI-modeled patient, each of these registration instances was validated using 40 landmarks. The displacement vector fields (DVFs) were used first to calculate the volumetric variation of each tetrahedron, which represents the change in the air volume. The calculated results were interpolated to generate 3D ventilation images. With the computed DVF, a finite element method (FEM) framework was developed to compute the stress images of the lung tissue. The regional compliance was then defined as the ratio of the ventilation and stress values and was calculated for each phase. Based on iterative FEM simulations, the potential range of the mechanical parameters for the lung was determined by comparing the model-computed average stress to the clinical reference value of airway pressure. The effect of the parameter variations on the computed stress distributions was estimated using Pearson correlation coefficients. Results: For the POPI-modeled patient, five exhalation phases from the start to the end of exhalation were denoted by P{sub i}, i=1,...,5, respectively. The average lung volume variation relative to the reference phase (P{sub 5}) was reduced from 18% at P{sub 1} to 4.8% at P{sub 4}. The average stress at phase P{sub i} was 1.42, 1.34, 0.74, and 0.28 kPa, and the average regional compliance was 0.19, 0.20, 0.20, and 0.24 for i=1,...,4, respectively. For the other five patients, their average R{sub v} value at the end-inhalation phase was 21.1%, 19.6%, 22.4%, 22.5%, and 18.8%, respectively, and the regional compliance averaged over all six patients is 0.2. For elasticity parameters chosen from the potential parameter range, the resultant stress distributions were found to be similar to each other with Pearson correlation coefficients greater than 0.81. Conclusions: A 4DCT-based mechanical model has been developed to calculate the ventilation and stress images of the lung. The resultant regional compliance represents the lung's elasticity property and is potentially useful in correlating regions of lung damage with radiation dose following a course of radiation therapy.

60 APPLIED LIFE SCIENCES↗

Investigation of a breathing surrogate prediction algorithm for prospective pulmonary gating

Purpose: A major challenge of four dimensional computed tomography (4DCT) in treatment planning and delivery has been the lack of respiration amplitude and phase reproducibility during image acquisition. The implementation of a prospective gating algorithm would ensure that images would be acquired only during user-specified breathing phases. This study describes the development and testing of an autoregressive moving average (ARMA) model for human respiratory phase prediction under quiet respiration conditions. Methods: A total of 47 4DCT patient datasets and synchronized respiration records was utilized in this study. Three datasets were used in model development and were removed from further evaluation of the ARMA model. The remaining 44 patient datasets were evaluated with the ARMA model for prediction time steps from 50 to 1000 ms in increments of 50 and 100 ms. Thirty-five of these datasets were further used to provide a comparison between the proposed ARMA model and a commercial algorithm with a prediction time step of 240 ms. Results: The optimal number of parameters for the ARMA model was based on three datasets reserved for model development. Prediction error was found to increase as the prediction time step increased. The minimum prediction time step required for prospective gating was selected to be half of the gantry rotation period. The maximum prediction time step with a conservative 95% confidence criterion was found to be 0.3 s. The ARMA model predicted peak inhalation and peak exhalation phases significantly better than the commercial algorithm. Furthermore, the commercial algorithm had numerous instances of missed breath cycles and falsely predicted breath cycles, while the proposed model did not have these errors. Conclusions: An ARMA model has been successfully applied to predict human respiratory phase occurrence. For a typical CT scanner gantry rotation period of 0.4 s (0.2 s prediction time step), the absolute error was relatively small, 0.06{+-}0.02 s at peak inhalation and 0.05{+-}0.04 s at peak exhalation. The application of the ARMA model for prospective pulmonary gating has been demonstrated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computer-aided detection of breast masses: Four-view strategy for screening mammography

Purpose: To improve the performance of a computer-aided detection (CAD) system for mass detection by using four-view information in screening mammography. Methods: The authors developed a four-view CAD system that emulates radiologists' reading by using the craniocaudal and mediolateral oblique views of the ipsilateral breast to reduce false positives (FPs) and the corresponding views of the contralateral breast to detect asymmetry. The CAD system consists of four major components: (1) Initial detection of breast masses on individual views, (2) information fusion of the ipsilateral views of the breast (referred to as two-view analysis), (3) information fusion of the corresponding views of the contralateral breast (referred to as bilateral analysis), and (4) fusion of the four-view information with a decision tree. The authors collected two data sets for training and testing of the CAD system: A mass set containing 389 patients with 389 biopsy-proven masses and a normal set containing 200 normal subjects. All cases had four-view mammograms. The true locations of the masses on the mammograms were identified by an experienced MQSA radiologist. The authors randomly divided the mass set into two independent sets for cross validation training and testing. The overall test performance was assessed by averaging the free response receiver operating characteristic (FROC) curves of the two test subsets. The FP rates during the FROC analysis were estimated by using the normal set only. The jackknife free-response ROC (JAFROC) method was used to estimate the statistical significance of the difference between the test FROC curves obtained with the single-view and the four-view CAD systems. Results: Using the single-view CAD system, the breast-based test sensitivities were 58% and 77% at the FP rates of 0.5 and 1.0 per image, respectively. With the four-view CAD system, the breast-based test sensitivities were improved to 76% and 87% at the corresponding FP rates, respectively. The improvement was found to be statistically significant (p<0.0001) by JAFROC analysis. Conclusions: The four-view information fusion approach that emulates radiologists' reading strategy significantly improves the performance of breast mass detection of the CAD system in comparison with the single-view approach.

60 APPLIED LIFE SCIENCES↗

A constrained, total-variation minimization algorithm for low-intensity x-ray CT

Purpose: The authors developed an iterative image-reconstruction algorithm for application to low-intensity computed tomography projection data, which is based on constrained, total-variation (TV) minimization. The algorithm design focuses on recovering structure on length scales comparable to a detector bin width. Methods: Recovering the resolution on the scale of a detector bin requires that pixel size be much smaller than the bin width. The resulting image array contains many more pixels than data, and this undersampling is overcome with a combination of Fourier upsampling of each projection and the use of constrained, TV minimization, as suggested by compressive sensing. The presented pseudocode for solving constrained, TV minimization is designed to yield an accurate solution to this optimization problem within 100 iterations. Results: The proposed image-reconstruction algorithm is applied to a low-intensity scan of a rabbit with a thin wire to test the resolution. The proposed algorithm is compared to filtered backprojection (FBP). Conclusions: The algorithm may have some advantage over FBP in that the resulting noise level is lowered at equivalent contrast levels of the wire.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deconvolution by finite-size-source effects of x-ray phase-contrast images

Purpose: In the hard x-ray region, the cross sections for the phase shift of low-Z elements are about 1000 times larger than the absorption ones. As a consequence, phase contrast is detectable even when absorption contrast is minimal or absent. Therefore, phase-contrast imaging could become a valid alternative to absorption contrast without delivering high dose to tissue/human body parts. Methods: To enhance the quality of phase-contrast images without increasing the dose, a possible approach could be the partial deconvolution of the finite source size effects by experimental phase-contrast images. The deconvolution procedure, the authors propose, employs the acquisition of two images on a suitable well-known test sample, one in contact and the other in phase-contrast conditions. Both acquired images are used along with a simulated phase-contrast image (obtained from the test sample in ideal conditions of pointlike source illumination) to correctly retrieve the experimental source distribution function. This information allows a generic experimental phase-contrast image, acquired in the same conditions, to be partially deconvolved by finite source size effects. Results: The performed experimental tests indicate that deconvolved images are equivalent to those which would be obtained with a source 40% smaller than the actual size. In turn, this finding is equivalent to an increase of the ''effective'' lateral spatial coherence length. The corresponding quality improvement of the phase-contrast imaging is directly deducible by the presence of many Fresnel fringes, much better visible with respect to the original experimental phase-contrast images. Conclusions: The use of a test standard sample, always possible in every experimental setup, to partially deconvolve the finite-size-source blurring effects shows that higher quality phase-contrast images could be readily available, making easier diagnoses and tissue/sample analyses. The method could give, in the future, the possibility to further lower the delivered dose to patients, organs, and tissues when compact room-sized and brilliant microfocus x-ray sources will be available for clinical applications in hospitals.

60 APPLIED LIFE SCIENCES↗

Development and evaluation of a computer-aided diagnostic scheme for lung nodule detection in chest radiographs by means of two-stage nodule enhancement with support vector classification

Purpose: To develop a computer-aided detection (CADe) scheme for nodules in chest radiographs (CXRs) with a high sensitivity and a low false-positive (FP) rate. Methods: The authors developed a CADe scheme consisting of five major steps, which were developed for improving the overall performance of CADe schemes. First, to segment the lung fields accurately, the authors developed a multisegment active shape model. Then, a two-stage nodule-enhancement technique was developed for improving the conspicuity of nodules. Initial nodule candidates were detected and segmented by using the clustering watershed algorithm. Thirty-one shape-, gray-level-, surface-, and gradient-based features were extracted from each segmented candidate for determining the feature space, including one of the new features based on the Canny edge detector to eliminate a major FP source caused by rib crossings. Finally, a nonlinear support vector machine (SVM) with a Gaussian kernel was employed for classification of the nodule candidates. Results: To evaluate and compare the scheme to other published CADe schemes, the authors used a publicly available database containing 140 nodules in 140 CXRs and 93 normal CXRs. The CADe scheme based on the SVM classifier achieved sensitivities of 78.6% (110/140) and 71.4% (100/140) with averages of 5.0 (1165/233) FPs/image and 2.0 (466/233) FPs/image, respectively, in a leave-one-out cross-validation test, whereas the CADe scheme based on a linear discriminant analysis classifier had a sensitivity of 60.7% (85/140) at an FP rate of 5.0 FPs/image. For nodules classified as ''very subtle'' and ''extremely subtle,'' a sensitivity of 57.1% (24/42) was achieved at an FP rate of 5.0 FPs/image. When the authors used a database developed at the University of Chicago, the sensitivities was 83.3% (40/48) and 77.1% (37/48) at an FP rate of 5.0 (240/48) FPs/image and 2.0 (96/48) FPs /image, respectively. Conclusions: These results compare favorably to those described for other commercial and noncommercial CADe nodule detection systems.

60 APPLIED LIFE SCIENCES↗

Technical Note: Unsupervised C-arm pose tracking with radiographic fiducial

Purpose: C-arm fluoroscopy reconstruction, such as that used in prostate brachytherapy, requires that the relative poses of the individual C-arm fluoroscopy images must be known prior to reconstruction. Radiographic fiducials can provide excellent C-arm pose tracking, but they need to be segmented in the image. The authors report an automated and unsupervised method that does not require prior segmentation of the fiducial. Methods: The authors compute the individual C-arm poses relative to a stationary radiographic fiducial of known geometry. The authors register a filtered 2D fluoroscopy image of the fiducial to its 3D model by using image intensity alone without prior segmentation. To enhance the C-arm images, the authors investigated a three-step cascade filter and a line enhancement filter. The authors tested the method on a composite fiducial containing beads, straight lines, and ellipses. Ground-truth C-arm pose was provided by a clinically proven method. Results: Using 111 clinical C-arm images and {+-}10 deg. and {+-}10 mm random perturbation around the ground-truth pose, a total of 2775 cases were evaluated. The average rotation and translation errors were 0.62 deg. (STD=0.31 deg.) and 0.72 mm (STD=0.55 mm) for the three-step filter and 0.67 deg. (STD=0.40 deg.) and 0.87 mm (STD=0.27 mm) using the line enhancement filter. Conclusions: The C-arm pose tracking method was sufficiently accurate and robust on human patient data for subsequent 3D implant reconstruction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

FBP and BPF reconstruction methods for circular X-ray tomography with off-center detector

Purpose: Circular scanning with an off-center planar detector is an acquisition scheme that allows to save detector area while keeping a large field of view (FOV). Several filtered back-projection (FBP) algorithms have been proposed earlier. The purpose of this work is to present two newly developed back-projection filtration (BPF) variants and evaluate the image quality of these methods compared to the existing state-of-the-art FBP methods. Methods: The first new BPF algorithm applies redundancy weighting of overlapping opposite projections before differentiation in a single projection. The second one uses the Katsevich-type differentiation involving two neighboring projections followed by redundancy weighting and back-projection. An averaging scheme is presented to mitigate streak artifacts inherent to circular BPF algorithms along the Hilbert filter lines in the off-center transaxial slices of the reconstructions. The image quality is assessed visually on reconstructed slices of simulated and clinical data. Quantitative evaluation studies are performed with the Forbild head phantom by calculating root-mean-squared-deviations (RMSDs) to the voxelized phantom for different detector overlap settings and by investigating the noise resolution trade-off with a wire phantom in the full detector and off-center scenario. Results: The noise-resolution behavior of all off-center reconstruction methods corresponds to their full detector performance with the best resolution for the FDK based methods with the given imaging geometry. With respect to RMSD and visual inspection, the proposed BPF with Katsevich-type differentiation outperforms all other methods for the smallest chosen detector overlap of about 15 mm. The best FBP method is the algorithm that is also based on the Katsevich-type differentiation and subsequent redundancy weighting. For wider overlap of about 40-50 mm, these two algorithms produce similar results outperforming the other three methods. The clinical case with a detector overlap of about 17 mm confirms these results. Conclusions: The BPF-type reconstructions with Katsevich differentiation are widely independent of the size of the detector overlap and give the best results with respect to RMSD and visual inspection for minimal detector overlap. The increased homogeneity will improve correct assessment of lesions in the entire field of view.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Zone-based analysis for automated detection of abnormalities in chest radiographs

Purpose: The aim of this study was to develop an automated method for detection of local texture-based and density-based abnormalities in chest radiographs. Methods: The method was based on profile analysis to detect abnormalities in chest radiographs. In the method, one density-based feature, Density Symmetry Index, and two texture-based features, Roughness Maximum Index and Roughness Symmetry Index, were used to detect abnormalities in the lung fields. In each chest radiograph, the lung fields were divided into four zones initially and then the method was applied to each zone separately. For each zone, Density Symmetry Index was obtained from the projection profile of each zone, and Roughness Maximum Index and Roughness Symmetry Index were obtained by measuring the roughness of the horizontal profiles via moving average technique. Linear discriminant analysis was used to classify normal and abnormal cases based on the three indices. The discriminant performance of the method was evaluated using ROC analysis. Results: The method was evaluated on a database of 250 normal and 250 abnormal chest images. In the optimized conditions, the zone-based performance Az of the method for zones 1, 2, 3, and 4 were 0.917, 0.897, 0.892, and 0.814, respectively, and the case-based performance Az of the method was 0.842. Our previous method for detection of gross abnormalities was also evaluated on the same database. The case-based performance of our previous method was 0.689. Conclusions: In comparing the previous method and the new method proposed in this study, there was a great improvement by the new method for detection of local texture-based and density-based abnormalities. The new method combined with the previous one has potential for screening abnormalities in chest radiographs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗