Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Measurement of Doubly Charged Ions in Ion Thruster Plumes

The ratio of doubly to singly charged ions was measured in the plumes of a 30 cm and of a 40 cm ion thruster. The measured ratio was correlated with observed erosion rates and thruster operating conditions. The measured and calculated erosion rates paralleled variation in the j(sup ++)/j(sup +) ratio and indicated that the erosion was dominated by Xe III. Simple models of cathode potential surfaces which were developed in support of this work were in agreement with this conclusion and provided a predictive capability of the erosion given the ratio of doubly to singly charged ion currents.

Williams, George J., Jr.↗

Ring Current Ion Coupling with Electromagnetic Ion Cyclotron Waves

A new ring current global model has been developed that couples the system of two kinetic equations: one equation describes the ring current (RC) ion dynamic, and another equation describes wave evolution of electromagnetic ion cyclotron waves (EMIC). The coupled model is able to simulate, for the first time self-consistently calculated RC ion kinetic and evolution of EMIC waves that propagate along geomagnetic field lines and reflect from the ionosphere. Ionospheric properties affect the reflection index through the integral Pedersen and Hall conductivities. The structure and dynamics of the ring current proton precipitating flux regions, intensities of EMIC global RC energy balance, and some other parameters will be studied in detail for the selected geomagnetic storms.

Khazanov. G. V.↗

Ring Current Ion Coupling with Electromagnetic Ion Cyclotron Waves

A new ring current global model has been developed for the first time that couples the system of two kinetic equations: one equation describes the ring current (RC) ion dynamic, and another equation describes wave evolution of electromagnetic ion cyclotron waves (EMIC). The coupled model is able to simulate, for the first time self-consistently calculated RC ion kinetic and evolution of EMIC waves that propagate along geomagnetic field lines and reflect from the ionosphere. Ionospheric properties affect the reflection index through the integral Pedersen and Hall coductivities. The structure and dynamics of the ring current proton precipitating flux regions, intensities of EMIC, global RC energy balance, and some other parameters will be studied in detail for the selected geomagnetic storms. The space whether aspects of RC modelling and comparison with the data will also be discussed.

Khazanov, George V.↗

On Alfvenic Waves and Stochastic Ion Heating with 1Re Observations of Strong Field-aligned Currents, Electric Fields, and O+ ions

The role that the cleft/cusp has in ionosphere/magnetosphere coupling makes it a very dynamic region having similar fundamental processes to those within the auroral regions. With Polar passing through the cusp at 1 Re in the Spring of 1996, we observe a strong correlation between ion heating and broadband ELF (BBELF) emissions. This commonly observed relationship led to the study of the coupling of large field-aligned currents, burst electric fields, and the thermal O+ ions. We demonstrate the role of these measurements to Alfvenic waves and stochastic ion heating. Finally we will show the properties of the resulting density cavities.

Coffey, Victoria↗

Ion Propulsion Thruster Including a Plurality of Ion Optic Electrode Pairs

Ion optics for use in a conventional or annular or other shaped ion thruster are disclosed including a plurality of planar, spaced apart ion optic electrode pairs sized to include a diameter smaller than the diameter of thruster exhaust and retained in, on or otherwise associated with a frame across the thruster exhaust. An electrical connection may be provided for establishing electrical connectivity among a set of first upstream electrodes and an electrical connection may be provided for establishing electrical connectivity among the second downstream electrodes.

Patterson, Michael J.↗

Device for separating non-ions from ions

A device for separating non-ions from ions is disclosed. The device includes a plurality of electrodes positioned around a center axis of the device and having apertures therein through which the ions are transmitted. An inner diameter of the apertures varies in length. At least a portion of the center axis between the electrodes is non-linear.

47 OTHER INSTRUMENTATION↗

Rechargeable metal-ion battery with non-aqueous hybrid ion electrolyte

A method is provided for forming a rechargeable metal-ion battery with a non-aqueous hybrid ion electrolyte. The method provides a transition metal hexacyanometallate (TMHCM) cathode (AXM1YM2Z(CN)N.MH2O), where “A” is from a first group of metals, and M1 and M2 are transition metals. The electrolyte includes a first type of cation from the first group of metals, different than “A”. The method connects the cathode and anode to external circuitry to perform initial charge/discharge operations. As a result, a hybrid ion electrolyte is formed including the first type of cation and “A” cations. Subsequently, cations are inserted into the anode during charging, which alternatively may be only “A” cations, only the first type of cation, or both the “A” cations and the first type of cation. Only “A” cations, only the first type, or both “A” and the first type of cation are inserted into the TMHCM during discharge.

Wang, Long↗

Fourier Transform-Ion Cyclotron Resonance Mass Spectrometry as a Platform for Characterizing Multimeric Membrane Protein Complexes

Membrane protein characterization is consistently hampered by challenges with expression, purification, and solubilization. Among several biophysical techniques employed for their characterization, native-mass spectrometry (MS) has emerged as a powerful tool for the analysis of membrane proteins and complexes. Here, two MS platforms, the FT-ICR and Q-ToF, have been explored to analyze the homotetrameric water channel protein, AquaporinZ (AqpZ), under non-denaturing conditions. This 97 kDa membrane protein complex can be readily liberated from the octylglucoside (OG) detergent micelle under a range of instrument conditions on both MS platforms. Increasing the applied collision energy of the FT-ICR collision cell yielded varying degrees of tetramer (97 kDa) liberation from the OG micelles, as well as dissociation into the trimeric (72 kDa) and monomeric (24 kDa) substituents. Tandem-MS on the Q-ToF yielded higher intensity tetramer signal and, depending on the m/z region selected, the observed monomer signal varied in intensity. Precursor ion selection of an m/z range above the expected protein signal distribution, followed by mild collisional activation, is able to efficiently liberate AqpZ with a high S/N ratio. The tetrameric charge state distribution obtained on both instruments demonstrated superpositioning of multiple proteoforms due to varying degrees of N-terminal formylation. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Native Top-Down Mass Spectrometry and Ion Mobility MS for Characterizing the Cobalt and Manganese Metal Binding of α-Synuclein Protein

Structural characterization of intrinsically disordered proteins (IDPs) has been a major challenge in the field of protein science due to limited capabilities to obtain full-length high-resolution structures. Native ESI-MS with top-down MS was utilized to obtain structural features of protein-ligand binding for the Parkinson’s disease-related protein, α-synuclein (αSyn), which is natively unstructured. Binding of heavy metals has been implicated in the accelerated formation of αSyn aggregation. Using high-resolution Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry, native top-down MS with various fragmentation methods, including electron capture dissociation (ECD), collisional activated dissociation (CAD), and multistage tandem MS (MS{sup 3}), deduced the binding sites of cobalt and manganese to the C-terminal region of the protein. Ion mobility MS (IM-MS) revealed a collapse toward compacted states of αSyn upon metal binding. The combination of native top-down MS and IM-MS provides structural information of protein-ligand interactions for intrinsically disordered proteins. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Native Ion Mobility Mass Spectrometry: When Gas-Phase Ion Structures Depend on the Electrospray Charging Process

Ion mobility spectrometry (IMS) has become popular to characterize biomolecule folding. Numerous studies have shown that proteins that are folded in solution remain folded in the gas phase, whereas proteins that are unfolded in solution adopt more extended conformations in the gas phase. Here, we discuss how general this tenet is. We studied single-stranded DNAs (human telomeric cytosine-rich sequences with CCCTAA repeats), which fold into an intercalated motif (i-motif) structure in a pH-dependent manner, thanks to the formation of C–H{sup +}–C base pairs. As i-motif formation is favored at low ionic strength, we could investigate the ESI-IMS-MS behavior of i-motif structures at pH ~ 5.5 over a wide range of ammonium acetate concentrations (15 to 100 mM). The control experiments consisted of either the same sequence at pH ~ 7.5, wherein the sequence is unfolded, or sequence variants that cannot form i-motifs (CTCTAA repeats). The surprising results came from the control experiments. We found that the ionic strength of the solution had a greater effect on the compactness of the gas-phase structures than the solution folding state. This means that electrosprayed ions keep a memory of the charging process, which is influenced by the electrolyte concentration. We discuss these results in light of the analyte partitioning between the droplet interior and the droplet surface, which in turn influences the probability of being ionized via a charged residue-type pathway or a chain extrusion-type pathway. .

74 ATOMIC AND MOLECULAR PHYSICS↗

Facile electrostatic self-assembly of silicon/reduced graphene oxide porous composite by silica assist as high performance anode for Li-ion battery

Silicon(Si)/graphene composite has been regarded as one of the most promising candidates for next generation anode materials with high power and energy density in lithium ion batteries. Introduction of graphene in Si anodes could improve the electronic conductivity, suppress the severe volume expansion of Si, and facilitate the formation of stable solid electrolyte interphase, etc. However, traditionally mechanical mixing of Si and graphene cannot realize uniform distribution of Si particles on the graphene sheets, which would largely weaken the effectiveness of the graphene in the composite. In this work, nano-Si/reduced graphene oxide porous composite (p Si/rGO) has been fabricated by a facile electrostatic self-assembly approach via using SiO2 as the sacrificial template. Compared with the simply mechanically mixed nano-Si and rGO (Si/rGO), the nano-Si particles could be more uniformly dispersed among the rGO sheets in the p Si/rGO, which significantly increases its electronic conductivity. Moreover, the drastic volume expansion of nano-Si during repeated lithiation/delithiation cycles also has been effectively accommodated by the large number of pores left after removing the SiO2 template in the composite. Thus, the p Si/rGO presented largely enhanced electrochemical performances, showing a high reversible capacity up to 1849?mA?h?g-1 at 0.2?A?g-1 with good capacity retention, and high rate capability (535?mA?h?g-1 at 2?A?g-1).

Silicon, Reduced graphene oxide, Electrostatic sel↗

Methodologies for Design, Characterization and Testing of Electrolytes that Enable Extreme Fast Charging of Lithium-ion Cells

Selection, testing and validation of electrolyte candidates for Li-ion cells are discussed, based on a 10-minute target for extreme fast charge (XFC). A combination of modeling and laboratory measurements create a timely and synergistic approach to identifying candidate electrolyte formulations. Multi-solvent systems provide a balanced set of properties, wherein lower molecular-weight solvents offer reduced viscosity, increased species diffusivity, and mitigation of concentration polarization at high charge rates. Carefully selected formulations can exhibit peak conductivity and usable conductivity range of two to three times that of the baseline EC-EMC (3:7, wt.) + LiPF 6 . Candidates are also chosen based on stability and longevity within the cell environment. Lab testing coincides with property predictions from the Advanced Electrolyte Model (AEM) and a macro-scale cell model. Furthermore, cell testing utilized coin and pouch cells having NMC532 or NMC811 cathodes with graphite electrodes. Results indicate combinations of low-molecular weight solvents are key for fast-charge electrolytes as they extend the useful conductivity range to both low and higher salt concentrations, and possess higher self-diffusivities compared to conventional solvents. This reduces impacts from concentration polarization. The choice of electrolyte also influences the tendency for lithium metal deposition at the anode, as showcased by experimental and modeling results herein.

25 ENERGY STORAGE↗

Separation of cobalt, nickel, and manganese in leach solutions of waste lithium-ion batteries using Dowex M4195 ion exchange resin

Current methods to separate and recover critical metals from waste lithium-ion battery (LIB) scrap require multiple unit operations that involve selective leaching and a combination of separation methods. These methods include impurity removal, solvent extraction, ion exchange, and precipitation, to achieve high purity Co and Ni products. In this paper an efficient extraction strategy was developed to individually separate Ni and Co from a LIB leachate that was generated from an electrochemical leaching process. By using Dowex M4195 resin, as the only method of separation, additional impurity removal operations were not needed. After loading and eluting, three different fractions were obtained: 99.0% Ni concentrate, 98.5% Co concentrate, and a Li/Mn rich concentrate allowing the separation of Ni, Co and Mn. Here, the developed process is then presented as an alternative for metal recovery from leachates from scrap LIBs with minimum chemical addition and pH adjustment.

36 MATERIALS SCIENCE↗

Influence of Ga{sup 3+} ions on spectroscopic and dielectric features of multi component lithium lead boro bismuth silicate glasses doped with manganese ions

Graphical abstract: The plots between ε″(ω)ω vs. ε′(ω) and ε″(ω)/ω vs. ε′(ω) yield straight lines with slope 1/τ and τ, respectively. Considerable deviation from the straight line is observed in the high frequency region. Such deviation suggests spreading of relaxation times and this is attributed to the presence of multiple type of dipoles in the glass matrix. Variation of the parameters ωε″(ω) and ε″(ω)/ω with ε′(ω) of glass Li{sub 2}O–PbO–B{sub 2}O{sub 3}–SiO{sub 2}–Bi{sub 2}O{sub 3}–MnO multi-component glasses mixed with 2.0 mol% of Ga{sub 2}O{sub 3} measured at 373 K. - Highlights: • A series of Li{sub 2}O–PbO–B{sub 2}O{sub 3}–SiO{sub 2}–Bi{sub 2}O{sub 3}–MnO:Ga{sub 2}O{sub 3} glasses have been synthesized. • A variety of spectroscopic and dielectric properties have been investigated. • Analysis of the results indicated that glasses with below 3.0 mol% Ga{sub 2}O{sub 3} are good conducting materials. - Abstract: Multi-component glasses of the chemical composition 19.5Li{sub 2}O–20PbO–20B{sub 2}O{sub 3}–30SiO–(10 − x)Bi{sub 2}O{sub 3}–0.5MnO:xGa{sub 2}O{sub 3} with 0 ≤ x ≤ 5.0 have been synthesized. Spectroscopic (optical absorption, IR, Raman and ESR) and dielectric properties were investigated. Optical absorption and ESR spectral studies have indicated that managanese ions do exist in Mn{sup 3+} state in addition to Mn{sup 2+} state in the samples containing low concentration of Ga{sub 2}O{sub 3}. The IR and Raman studies indicated increasing degree of disorder in the glass network with the concentration of Ga{sub 2}O{sub 3} up to 3.0 mol%. The dielectric constant, loss and ac conductivity are observed to increase with the concentration of Ga{sub 2}O{sub 3} up to 3.0 mol%. The quantitative analysis of the results of dielectric properties has indicated an increase in the insulating strength of the glasses as the concentration of Ga{sub 2}O{sub 3} is raised beyond 3.0 mol%. This has been attributed to adaption of gallium ions from octahedral to tetrahedral coordination.

36 MATERIALS SCIENCE↗