Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMAGE ALIGNMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Hard X-ray imaging with sub-10 nm resolution by scanning bonded 2D multilayer Laue lenses

Multilayer Laue lenses (MLLs) offer significant advantages over traditional diffractive focusing optics, such as zone plates (ZPs), in terms of efficiency and durability when focusing hard X-rays to 10 nm and below. Typically, a pair of 1D MLLs is aligned independently to achieve point focusing. This approach only permits scanning microscopy by moving the sample stage, which presents a limitation when it comes to scanning large or bulky objects at high speed. In this study, we present an experimental demonstration of scanning monolithically bonded 2D MLLs while keeping the sample stationary, effectively addressing the limitation of the sample’s size and weight. We characterized the system’s positional and angular stabilities during scanning, which are critical parameters to the nanofocusing performance of MLLs. In addition, we provided the X-ray measurement results and corresponding image resolution analysis.

36 MATERIALS SCIENCE↗

TU-EF-204-04: Feasibility Study of a Novel Stationary Spectral CT Scanner

Purpose: To evaluate a cadmium zinc telluride (CZT) detector module and to develop a proof-of-concept bench-top system to examine the concept and feasibility of a stationary spectral scanner that would consist of a CZT detector ring and a distributed source for rotationless imaging. Methods: The bench-top system employs a double-rotation set-up with two concentric but independent rotating stages, one for turning the object at sparse angles to mimic the imaging from a sequentially activated source distributed on a ring, while the other for translating the detector module to simulate a projection arc along a virtual detector ring. A source of 30-degree fan is used in the set-up, and the ring is designed to be 85cm in diameter in order to provide a 22cm field-of-view that is large enough for an average human head. The CZT detector module has 16×16 0.5mm pixels and eight global energy thresholds, and is attached to an experimental data acquisition board from the same vendor (Nova R&D). Its pixel gain is first calibrated using radioisotope Tc-99m to align the photo-peaks. Count rate performance is assessed using the X-ray source. Air and offset corrections are done prior to each CT scan. A 10cm acrylic phantom with 5 different inserts is imaged at 100kVp, 2mA, with an effective exposure window of 150ms per projection. Reconstruction is done using a total variation-type iterative method. Results: The detector module exhibited large gain variations among pixels. Average count rate was over 1Mcps per pixel. Parallax effect was observed along the arcs but was corrected. Reconstructed images from two energy bins demonstrated good contrast, spatial resolution and image uniformity, with little artifacts. Conclusion: The CZT detector tested is suitable for imaging relatively small objects. A stationary spectral CT appears feasible should we have enough buttable modules and a distributed source. This work was supported by Ministry of Science and Technology of China through grants 11YQ040082 and 2012BAI13B04.

60 APPLIED LIFE SCIENCES↗

Redshift-dependent RSD bias from intrinsic alignment with DESI Year 1 spectra

ABSTRACT We estimate the redshift-dependent, anisotropic clustering signal in the Dark Energy Spectroscopic Instrument (DESI) Year 1 Survey created by tidal alignments of Luminous Red Galaxies (LRGs) and a selection-induced galaxy orientation bias. To this end, we measured the correlation between LRG shapes and the tidal field with DESI’s Year 1 redshifts, as traced by LRGs and Emission-Line Galaxies. We also estimate the galaxy orientation bias of LRGs caused by DESI’s aperture-based selection, and find it to increase by a factor of seven between redshifts 0.4−1.1 due to redder, fainter galaxies falling closer to DESI’s imaging selection cuts. These effects combine to dampen measurements of the quadrupole of the correlation function (ξ2) caused by structure growth on scales of 10–80 h−1 Mpc by about 0.15 per cent for low redshifts (0.4 < z < 0.6) and 0.8 per cent for high (0.8 < z < 1.1), a significant fraction of DESI’s error budget. We provide estimates of the ξ2 signal created by intrinsic alignments that can be used to correct this effect, which is necessary to meet DESI’s forecasted precision on measuring the growth rate of structure. While imaging quality varies across DESI’s footprint, we find no significant difference in this effect between imaging regions in the Legacy Imaging Survey.

79 ASTRONOMY AND ASTROPHYSICS↗

Electric Field Conjugation in the Presence of Model Uncertainty

The Wide-Field Infrared Survey Telescope (WFIRST) is a 2.4-meter-diameter space telescope NASA program. The payload will include a coronagraph instrument (CGI). The CGI designs under development use deformable mirrors (DM) to create a point spread function (PSF) with a dark region around the obscured star object. Electric field conjugation (EFC) is an iterative nonlinear optimization procedure that uses measurements of the electric field at the image to determine the DM displacements to modify the PSF to create the region of high contrast in the image. EFC requires a numerical model of the coronagraph to calculate the Jacobian of the system, which is used, along with regularization, to solve for the DM displacements for each iteration of the nonlinear optimization. Ideally, the coronagraph is aligned and calibrated, and the calibration data are used in the numerical model for calculating the Jacobian. However, calibration and alignment measurements always contain uncertainty resulting in calibration error. Therefore, the Jacobian calculated from the numerical model is not an exact representation of the physical coronagraph, and the resulting DM solution for an EFC iteration does not have the exact impact on the electric field of the coronagraph as predicted by the EFC. The result is slow convergence, and, as will be shown, drives the use of more restrictive regularization. Using Monte Carlo trials, we investigate the effect of calibration error on EFC convergence and regulatization. Comparison to results from the High Contrast Imaging Testbed Hybrid Lyot Coronagraph are also presented.

Marx, David↗

Alignment of the Grating Wheel Mechanism for a Ground-Based, Cryogenic, Near-Infrared Astronomy Instrument

We describe the population, optomechanical alignment, and alignment verification of near-infrared gratings on the grating wheel mechanism (GWM) for the Infrared Multi-Object Spectrometer (IRMOS). IRMOS is a cryogenic (80 K), principle investigator-class instrument for the 2.1 m and Mayall 3.8 m telescopes at Kitt Peak National Observatory, and a MEMS spectrometer concept demonstrator for the James Webb Space Telescope. The GWM consists of 13 planar diffraction gratings and one flat imaging mirror (58 x 57 mm), each mounted at a unique compound angle on a 32 cm diameter gear. The mechanism is predominantly made of Al 6061. The grating substrates are stress relieved for enhanced cryogenic performance. The optical surfaces are replicated from off-the-shelf masters. The imaging mirror is diamond turned. The GWM spans a projected diameter of approx. 48 cm when fully assembled, utilizes several flexure designs to accommodate potential thermal gradients, and is controlled using custom software with an off-the-shelf controller. Under ambient conditions, each grating is aligned in six degrees of freedom relative to a coordinate system that is referenced to an optical alignment cube mounted at the center of the gear. The local tip/tilt (Rx/Ry) orientation of a given grating is measured using the zero-order return from an autocollimating theodolite. The other degrees of freedom are measured using a two-axis cathetometer and rotary table. Each grating's mount includes a one-piece shim located between the optic and the gear. The shim is machined to fine align each grating. We verify ambient alignment by comparing grating difractive properties to model predictions.

Gutkowski, Sharon M.↗

Multipoint Observations of Dispersive Scale Alfvénic Field‐Line Resonances Associated With Substorm Auroral Beads

We present a case study of the field-aligned current (FAC) systems that transpire within the high-altitude auroral acceleration region of an “auroral bead” initiated double oval substorm observed on 23 February 2001 by the Cluster fleet. Conjunctive Cluster measurements and auroral images from IMAGE reveal that auroral bead current system formation and evolution is a multi-scale, injection-mediated process. The FACs at large scales vary on substorm evolution time scales (~minutes) in response to the injection and evolution of hotter denser magnetospheric plasma. Embedded within the large-scale FACs are intense short-scale (≲ few 10s of km) currents comprising dispersive scale Alfvén wave (DAW) fluctuations. The DAWs are a complex mixture of ingoing and reflected components that regularly interfere to form a broad spectrum of kinetic (dispersive) scale Alfvénic field-line resonances (KFLRs). The Alfvénic currents appear as a nested series of upward and downward FAC densities with amplitudes reaching a few 100 nA/m 2 . Energized field-aligned or counterstreaming electrons near keV energies and below are observed with parallel skews that vary in concert with variations in the DAW current sense. Positive correlations between DAW electric field energy densities and the energies of energized H + , He + , and O + outflow are observed, indicative of ion energization within the DAW fields. Due to their L-shell location (L~5.8–7.0) and associations with injections, the KFLRs are interpreted as the high-altitude auroral zone analog of KFLRs observed in the equatorial inner magnetosphere.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-J-44: A Novel Approach to Quantify Patient Setup and Target Motion for Real-Time Image-Guided Radiotherapy (IGRT)

Purpose Isocenter shifts and rotations to correct patient setup errors and organ motion cannot remedy some shape changes of large targets. We are investigating new methods in quantification of target deformation for realtime IGRT of breast and chest wall cancer. Methods Ninety-five patients of breast or chest wall cancer were accrued in an IRB-approved clinical trial of IGRT using 3D surface images acquired at daily setup and beam-on time via an in-room camera. Shifts and rotations relating to the planned reference surface were determined using iterative-closest-point alignment. Local surface displacements and target deformation are measured via a ray-surface intersection and principal component analysis (PCA) of external surface, respectively. Isocenter shift, upper-abdominal displacement, and vectors of the surface projected onto the two principal components, PC1 and PC2, were evaluated for sensitivity and accuracy in detection of target deformation. Setup errors for some deformed targets were estimated by superlatively registering target volume, inner surface, or external surface in weekly CBCT or these outlines on weekly EPI. Results Setup difference according to the inner-surface, external surface, or target volume could be 1.5 cm. Video surface-guided setup agreed with EPI results to within < 0.5 cm while CBCT results were sometimes (∼20%) different from that of EPI (>0.5 cm) due to target deformation for some large breasts and some chest walls undergoing deep-breath-hold irradiation. Square root of PC1 and PC2 is very sensitive to external surface deformation and irregular breathing. Conclusion PCA of external surfaces is quick and simple way to detect target deformation in IGRT of breast and chest wall cancer. Setup corrections based on the target volume, inner surface, and external surface could be significant different. Thus, checking of target shape changes is essential for accurate image-guided patient setup and motion tracking of large deformable targets. NIH grant for the first author as cionsultant and the last author as the PI.

60 APPLIED LIFE SCIENCES↗

Fiber orientation effects on ultra-high performance concrete formed by 3D printing

Despite the growing interest in 3D concrete printing, its current progress is limited by reinforcing methods. Inclusion of steel fibers is a potential reinforcing solution; however, the effect of printing process on orientation of the fibers is still unknown. This study aims to quantitatively investigate the orientation distribution of steel fibers in 3D printed ultra-high performance concrete. The effects of extrusion nozzle size, Cartesian print speed, and fiber volume fraction on the orientation of fibers were evaluated using digital image analysis. The consequent effects of the fiber orientation on the mechanical properties of the 3D-printed specimens were also determined. The results were compared with those of the conventionally mold-cast specimens. The results revealed that the smaller nozzle size and higher fiber volume fraction significantly enhanced the fiber alignment parallel to the printing direction. This preferential fiber alignment led to superior mechanical performance of the printed specimens to the mold-cast specimens.

36 MATERIALS SCIENCE↗

Gamma-ray imaging and holdup assays of 235-F PuFF cells 1 & 2

Savannah River National Laboratory (SRNL) Nuclear Measurements (L4120) was tasked with performing enhanced characterization of the holdup in the PuFF shielded cells. Assays were performed in accordance with L16.1-ADS-2460 using two high-resolution gamma-ray detectors. The first detector, an In Situ Object Counting System (ISOCS)-characterized detector, was used in conjunction with the ISOCS Geometry Composer software to quantify grams of holdup. The second detector, a Germanium Gamma-ray Imager (GeGI), was used to visualize the location and relative intensity of the holdup in the cells. Carts and collimators were specially designed to perform optimum assays of the cells. Thick, pencil-beam tungsten collimators were fabricated to allow for extremely precise targeting of items of interest inside the cells. Carts were designed with a wide range of motion to position and align the detectors. A total of 24 measurements were made, each typically 24 hours or longer to provide sufficient statistical precision. This report presents the results of the enhanced characterization for cells 1 and 2. The measured gram values agree very well with results from the 2014 study. In addition, images were created using both the 2014 data and the new GeGI data. The GeGI images of the cells walls reveal significant Pu-238 holdup on the surface of the walls in cells 1 and 2. Additionally, holdup is visible in the two pass-throughs from cell 1 to the wing cabinets. This report documents the final element (exterior measurements coupled with gamma-ray imaging and modeling) of the enhanced characterization of cells 1-5 (East Cell Line).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feasibility of Multimodal Deformable Registration for Head and Neck Tumor Treatment Planning

Purpose: To investigate the feasibility of using deformable registration in clinical practice to fuse MR and CT images of the head and neck for treatment planning. Method and Materials: A state-of-the-art deformable registration algorithm was optimized, evaluated, and compared with rigid registration. The evaluation was based on manually annotated anatomic landmarks and regions of interest in both modalities. We also developed a multiparametric registration approach, which simultaneously aligns T1- and T2-weighted MR sequences to CT. This was evaluated and compared with single-parametric approaches. Results: Our results show that deformable registration yielded a better accuracy than rigid registration, without introducing unrealistic deformations. For deformable registration, an average landmark alignment of approximatively 1.7 mm was obtained. For all the regions of interest excluding the cerebellum and the parotids, deformable registration provided a median modified Hausdorff distance of approximatively 1 mm. Similar accuracies were obtained for the single-parameter and multiparameter approaches. Conclusions: This study demonstrates that deformable registration of head-and-neck CT and MR images is feasible, with overall a significanlty higher accuracy than for rigid registration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Unraveling the Mechanism of Interfacial Charge Transfer and Photoresponsivity of WS 2 Quantum Dots/MoS 2 (0D–2D) Heterostructure-Based Transistors

To assess the efficacy of a mixed-dimensional van der Waals (vdW) heterostructure in modulating the optoelectronic responses of nanodevices, the charge transport properties of the transition-metal dichalcogenide (TMD)-based heterostructure comprising zero-dimensional (0D) WS 2 quantum dots (QDs) and two-dimensional (2D) MoS 2 flakes are critically analyzed. Herein, a facile strategy was materialized in developing an atomically thin phototransistor assembled from mechanically exfoliated MoS 2 and WS 2 QDs synthesized using a one-pot hydrothermal route. The amalgamated photodetectors exhibited a high responsivity of ∼8000 A/W at an incident power of 0.05 nW of white light, surpassing that of the pristine MoS 2 devices. Furthermore, the detectivity of pristine MoS 2 , which was on the order of 10 10 , increased to 10 12 Jones for the WS 2 QDs/MoS 2 heterostructure photodetector, outperforming other WS 2 -based materials. The quasiparticle band gap and density of states (DOS) are further analyzed to elucidate the photophysics of the WS 2 QD/MoS 2 hybrid assembly. The difference in the work function between MoS 2 and WS 2 QDs gives rise to an electric field across the 0D–2D interface, facilitating effective charge separation and migration and contributing to the enhancement of photoresponsivity. The analysis of optical responses using density functional theory (DFT) revealed stronger absorption and less reflection over a broader spectrum of wavelengths for the heterostructure compared to the pristine materials. The estimated optical conductivity aligns well with the experimentally predicted maximum photoresponsivity under visible light, which is attributed to the high absorbance of 2D MoS 2 . In conclusion, combining diverse spectroscopic and imaging techniques with quantum simulation provides insights that clarify the pertinence of 0D–2D TMDs in designing phototransistors.

WS2 QDs/MoS2 heterostructure↗

Nuclear imaging to diagnose and correct target-driver registration at high-repetition-rate for improved reactor efficiency

Inertial Confinement Fusion produces energy from a burning plasma lasting a fraction of a nanosecond. Power plant designs based on Inertial Fusion Energy (IFE) will need to ignite targets 1-10 times a second, fired as projectiles into a chamber and delivering the driver to the target location. Driver asymmetry is known to impact ICF experiments at gain near unity and remains a candidate for primary yield degradation, and therefore fusion power plant energy output, for high-gain target designs. For a Fusion Power Plant (FPP), continuous and real-time monitoring of target performance provides an opportunity to stabilize or correct the target-driver registration. This requires x-ray and neutron imaging with a large field-of-view, sufficiently high resolution, fast analysis and to subtend a minimal solid angle. We introduce design criteria for such an imaging system that uses a coded aperture and time-gated, lens-coupled scintillators as a viable solution and outline the research steps required to field such a system. Integrating the imaging system into an IFE power plant as part of an active feedback loop could increase average power output by reducing the failure rate due to mis-aligned drivers with respect to the target.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental test of magnetospheric models.

The barium cloud injection deep into the magnetosphere of Sept. 21, 1971, has revealed that the quiet-time near-equatorial nightside magnetic field is significantly different from that predicted by existing quite-time models. The influence of currents flowing on or near the geomagnetic equator gives the field a more tail-like structure at a distance as close as 5 earth radii. Several models have been tried out to obtain a best fit to the experimental observations of the shape of the field-aligned ion cloud. Although this method does not lead to a unique solution, the most acceptable option emerging from this analysis is a quiet-time tilted image-dipole model with a Williams-Mead tail field and a disclike ring current on the geomagnetic equator.

Barish, F. D.↗

Mesoscale waves as a probe of Jupiter's deep atmosphere

Images from the Voyager north/south mapping sequences were searched for waves. A remarkable class of mesoscale waves was identified, with the following features: (1) the wavetrains are usually aligned zonally, i.e., wavecrests are north-south; (2) the average wavelength is 300 km with a standard deviation of only 20%; (3) the wavetrains are long; (4) the waves occur within 25 degrees of the equator, the bulk being at the equator itself; (5) the waves are centered at the extrema (in latitude) of the zonal flow; and (6) the meridional extent of the waves is typically 1 degree of latitude. These observations are interpreted as evidence of gravity waves propagating vertically within a leaky duct. A three-level model is assumed composed of a stable duct which extends up to the base of the NH3 cloud deck near 600 mb. Above this is a thin wave-trapping region characterized by a Richardson number Ri less than 1/4 and containing a critical level, where the local value of the zonal flow velocity equals the phase speed of the wave. This in turn is overlain by a stable region, representing the tropopause region and stratosphere.

Flaser, F. M.↗

Ultrasonic and radiographic evaluation of advanced aerospace materials: Ceramic composites

Two conventional nondestructive evaluation techniques were used to evaluate advanced ceramic composite materials. It was shown that neither ultrasonic C-scan nor radiographic imaging can individually provide sufficient data for an accurate nondestructive evaluation. Both ultrasonic C-scan and conventional radiographic imaging are required for preliminary evaluation of these complex systems. The material variations that were identified by these two techniques are porosity, delaminations, bond quality between laminae, fiber alignment, fiber registration, fiber parallelism, and processing density flaws. The degree of bonding between fiber and matrix cannot be determined by either of these methods. An alternative ultrasonic technique, angular power spectrum scanning (APSS) is recommended for quantification of this interfacial bond.

Generazio, Edward R.↗

Monitoring of the Greenland Ice Sheet using ERS-1 synthetic aperture radar imagery

ERS-1 Synthetic Aperture Radar (SAR) imagery is shown to be suitable for monitoring the climate of the Greenland ice sheet and for measuring changes in its marginal position. Four distinct hydrologic zones are easily recognized. Zone boundaries align closely with elevation. Seasonal changes in at least one of these zones indicate that late Winter is a better time than late Summer for the collection of images intended for long term monitoring. Subtle variations of the backscatter intensity from the highest portions of the ice sheet where melting never occurs are believed to indicate surface topography.

Bindschadler, Robert↗

SOHO-Ulysses Coordinated Studies During the Two Extended Quadratures and the Radial Alignment of 2007-2008

During quadrature, plasma seen on the limb of the Sun, along the radi al direction to Ulysses, by SOHO or STEREO can be sampled in situ as lt later passes Ulysses. A figure shows a coronagraph image, the rad ial towards Ulysses at 58 deg. S. and the SOHO/UVCS slit positions d uring one set of observations. A CME subsequently occurred and passed Ulysses (at 3/4 AU) 15 days later.

Suess, S. T.↗

Pattern-Recognition System for Approaching a Known Target

A closed-loop pattern-recognition system is designed to provide guidance for maneuvering a small exploratory robotic vehicle (rover) on Mars to return to a landed spacecraft to deliver soil and rock samples that the spacecraft would subsequently bring back to Earth. The system could be adapted to terrestrial use in guiding mobile robots to approach known structures that humans could not approach safely, for such purposes as reconnaissance in military or law-enforcement applications, terrestrial scientific exploration, and removal of explosive or other hazardous items. The system has been demonstrated in experiments in which the Field Integrated Design and Operations (FIDO) rover (a prototype Mars rover equipped with a video camera for guidance) is made to return to a mockup of Mars-lander spacecraft. The FIDO rover camera autonomously acquires an image of the lander from a distance of 125 m in an outdoor environment. Then under guidance by an algorithm that performs fusion of multiple line and texture features in digitized images acquired by the camera, the rover traverses the intervening terrain, using features derived from images of the lander truss structure. Then by use of precise pattern matching for determining the position and orientation of the rover relative to the lander, the rover aligns itself with the bottom of ramps extending from the lander, in preparation for climbing the ramps to deliver samples to the lander. The most innovative aspect of the system is a set of pattern-recognition algorithms that govern a three-phase visual-guidance sequence for approaching the lander. During the first phase, a multifeature fusion algorithm integrates the outputs of a horizontal-line-detection algorithm and a wavelet-transform-based visual-area-of-interest algorithm for detecting the lander from a significant distance. The horizontal-line-detection algorithm is used to determine candidate lander locations based on detection of a horizontal deck that is part of the lander.

Huntsberger, Terrance↗