Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HELICITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Response to “Comment on ‘Motion of a helical vortex filament in superfluid {sup 4}He under the extrinsic form of the local induction approximation”’ [Phys. Fluids 26, 019101 (2014)]

I agree with the authors regarding their comments on the Donnelly-Glaberson instability for such helical filaments as those obtained in my paper. I also find merit in their derivation of the quantum LIA (local induction approximation) in the manner of the LIA of Boffetta et al. However, I disagree with the primary criticisms of Hietala and Hänninen. In particular, though they suggest LIA and local nonlinear equation modes are not comparable since the former class of models contains superfluid friction parameters, note that since these parameters are small one may take them to zero and consider a qualitative comparison of the models (which is what was done in my paper). Second, while Hietala and Hänninen criticize certain assumptions made in my paper (and the paper of Shivamoggi where the model comes from) since the results break-down when Ak → ∞, note that in my paper I state that any deviations from the central axis along which the filament is aligned must be sufficiently bounded in variation. Therefore, it was already acknowledged that Ak(=|Φ{sub x}|) should be sufficiently bounded, precluding the Ak → ∞ case. I also show that, despite what Hietala and Hänninen claim, the dispersion relation obtained in my paper is consistent with LIA, where applicable. Finally, while Hietala and Hänninen claim that the dispersion parameter should be complex valued, I show that their dispersion relation is wrong, since it was derived incorrectly (they assume the complex modulus of the potential function is constant, yet then use this to obtain a potential function with non-constant modulus)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a high dynamic range spectroscopic system for observation of neutral hydrogen atom density distribution in Large Helical Device core plasma

We report development of a high dynamic range spectroscopic system comprising a spectrometer with 30% throughput and a camera with a low-noise fast-readout complementary metal-oxide semiconductor sensor. The system achieves a 10{sup 6} dynamic range (∼20 bit resolution) and an instrumental function approximated by a Voigt profile with Gauss and Lorentz widths of 31 and 0.31 pm, respectively, for 656 nm light. The application of the system for line profile observations of the Balmer-α emissions from high temperature plasmas generated in the Large Helical Device is also presented. In the observed line profiles, emissions are detected in far wings more than 1.0 nm away from the line center, equivalent to neutral hydrogen atom kinetic energies above 1 keV. We evaluate atom density distributions in the core plasma by analyzing the line profiles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Space-resolved extreme ultraviolet spectroscopy free of high-energy neutral particle noise in wavelength range of 10–130 Å on the large helical device

A flat-field space-resolved extreme ultraviolet (EUV) spectrometer system working in wavelength range of 10–130 Å has been constructed in the Large Helical Device (LHD) for profile measurements of bremsstrahlung continuum and line emissions of heavy impurities in the central column of plasmas, which are aimed at studies on Z{sub eff} and impurity transport, respectively. Until now, a large amount of spike noise caused by neutral particles with high energies (≤180 keV) originating in neutral beam injection has been observed in EUV spectroscopy on LHD. The new system has been developed with an aim to delete such a spike noise from the signal by installing a thin filter which can block the high-energy neutral particles entering the EUV spectrometer. Three filters of 11 μm thick beryllium (Be), 3.3 μm thick polypropylene (PP), and 0.5 μm thick polyethylene terephthalate (PET: polyester) have been examined to eliminate the spike noise. Although the 11 μm Be and 3.3 μm PP filters can fully delete the spike noise in wavelength range of λ ≤ 20 Å, the signal intensity is also reduced. The 0.5 μm PET filter, on the other hand, can maintain sufficient signal intensity for the measurement and the spike noise remained in the signal is acceptable. As a result, the bremsstrahlung profile is successfully measured without noise at 20 Å even in low-density discharges, e.g., 2.9 × 10{sup 13} cm{sup −3}, when the 0.5 μm PET filter is used. The iron n = 3–2 Lα transition array consisting of FeXVII to FeXXIV is also excellently observed with their radial profiles in wavelength range of 10–18 Å. Each transition in the Lα array can be accurately identified with its radial profile. As a typical example of the method a spectral line at 17.62 Å is identified as FeXVIII transition. Results on absolute intensity calibration of the spectrometer system, pulse height and noise count analyses of the spike noise between holographic and ruled gratings and wavelength response of the used filters are also presented with performance of the present spectrometer system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Physics of forced magnetic reconnection in coaxial helicity injection experiments in National Spherical Torus Experiment

We numerically examine the physics of fast flux closure in transient coaxial helicity injection (CHI) experiments in National Spherical Torus Experiment (NSTX). By performing resistive Magnetohydrodynamics (MHD) simulations with poloidal injector coil currents held constant in time, we find that closed flux surfaces are formed through forced magnetic reconnection. Through a local Sweet-Parker type reconnection with an elongated current sheet in the injector region, closed flux surfaces expand in the NSTX global domain. Simulations demonstrate outflows approaching poloidally Alfvénic flows and reconnection times consistent with the Sweet-Parker model. Critical requirements for magnetic reconnection and flux closure are studied in detail. These primary effects, which are magnetic diffusivity, injector flux, injector flux footprint width, and rate of injector voltage reduction, are simulated for transient CHI experiments. The relevant time scales for effective reconnection are τ{sub V}<τ{sub rec}≈τ{sub A}√(S)(1+Pm){sup 1/4}<τ{sub R}, where τ{sub V} is the time for the injector voltage reduction, τ{sub A} is the poloidal Alfvén transit time, τ{sub R} is the global resistive diffusion time, and Pm and S are Prandtl and Lundquist numbers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of steady-state operation using ion cyclotron heating in the Large Helical Device

Using a handshake shape (HAS) antenna phasing dipole for ion cyclotron heating (ICH), the heating efficiency was higher than that using a previous poloidal array antenna in the Large Helical Device. In order to sustain the dipole operation, real-time feedback for impedance matching and maintaining the same phase and power was adopted during long-pulse discharge. The HAS antenna was designed to reduce parasitic losses associated with energetic particle and radio-frequency (RF) sheath effects by field-aligned current concentration on the midplane. Local hot spots and the inhomogeneity of the diverter heat profile in the toroidal direction were reduced. The long-pulse discharge with an electron density (n{sub e0}) of 1 × 10{sup 19} m{sup −3}, center electron temperature (T{sub e0}) of 2.5 keV, a plasma duration time (t{sub d}) of 19 min, and RF heating power (P{sub RF}) of 1 MW was achieved by ICH and electron cyclotron heating.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Extension of high T{sub e} regime with upgraded electron cyclotron resonance heating system in the Large Helical Device

Enhancement of the output power per gyrotron has been planned in the Large Helical Device (LHD). Three 77-GHz gyrotrons with an output power of more than 1 MW have been operated. In addition, a high power gyrotron with the frequency of 154 GHz (1 MW/5 s, 0.5 MW/CW) was newly installed in 2012, and the total injection power of Electron cyclotron resonance heating (ECRH) reached 4.6 MW. The operational regime of ECRH plasma on the LHD has been extended due to the upgraded ECRH system such as the central electron temperature of 13.5 keV with the line-averaged electron density n{sub e-fir} = 1 × 10{sup 19} m{sup −3}. The electron thermal confinement clearly improved inside the electron internal transport barrier, and the electron thermal diffusivity reached neoclassical level. The global energy confinement time increased with increase of n{sub e-fir}. The plasma stored energy of 530 kJ with n{sub e-fir} = 3.2 × 10{sup 19} m{sup −3}, which is 1.7 times larger than the previous record in the ECRH plasma in the LHD, has been successfully achieved.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Line spectrum and ion temperature measurements from tungsten ions at low ionization stages in large helical device based on vacuum ultraviolet spectroscopy in wavelength range of 500–2200 Å

Vacuum ultraviolet spectra of emissions released from tungsten ions at lower ionization stages were measured in the Large Helical Device (LHD) in the wavelength range of 500–2200 Å using a 3 m normal incidence spectrometer. Tungsten ions were distributed in the LHD plasma by injecting a pellet consisting of a small piece of tungsten metal and polyethylene tube. Many lines having different wavelengths from intrinsic impurity ions were observed just after the tungsten pellet injection. Doppler broadening of a tungsten candidate line was successfully measured and the ion temperature was obtained.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress in development of the neutron profile monitor for the large helical device

The neutron profile monitor stably operated at a high-count-rate for deuterium operations in the Large Helical Device has been developed to enhance the research on the fast-ion confinement. It is composed of a multichannel collimator, scintillation-detectors, and a field programmable gate array circuit. The entire neutron detector system was tested using an accelerator-based neutron generator. This system stably acquires the pulse data without any data loss at high-count-rate conditions up to 8 × 10{sup 5} counts per second.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study on in situ calibration for neutron flux monitor in the Large Helical Device based on Monte Carlo calculations

Neutron monitoring is important to manage safety of fusion experiment facilities because neutrons are generated in fusion reactions. Monte Carlo simulations play an important role in evaluating the influence of neutron scattering from various structures and correcting differences between deuterium plasma experiments and in situ calibration experiments. We evaluated these influences based on differences between the both experiments at Large Helical Device using Monte Carlo simulation code MCNP5. A difference between the both experiments in absolute detection efficiency of the fission chamber between O-ports is estimated to be the biggest of all monitors. We additionally evaluated correction coefficients for some neutron monitors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2D potential measurements by applying automatic beam adjustment system to heavy ion beam probe diagnostic on the Large Helical Device

Two-dimensional potential profiles in the Large Helical Device (LHD) were measured with heavy ion beam probe (HIBP). To measure the two-dimensional profile, the probe beam energy has to be changed. However, this task is not easy, because the beam transport line of LHD-HIBP system is very long (∼20 m), and the required beam adjustment consumes much time. To reduce the probe beam energy adjustment time, an automatic beam adjustment system has been developed. Using this system, required time to change the probe beam energy is dramatically reduced, such that two-dimensional potential profiles were able to be successfully measured with HIBP by changing the probe beam energy shot to shot.

43 PARTICLE ACCELERATORS↗

Coaxial pellets for metallic impurity injection on the large helical device

Two coaxial pellets with tungsten inserted into graphite carbon and polyethylene (PE) tubes are compared for tungsten spectroscopic study in the Large Helical Device. The tungsten pellet with carbon tube causes plasma collapse, while that with PE tube smoothly ablates without collapse. The deposition profile of the pellets is analyzed with a help of pellet ablation spectroscopy. It is found that the tungsten pellet with carbon tube can significantly penetrate into the core plasma and leads to the plasma collapse. A tungsten spectrum with radial profile is successfully observed when the tungsten pellet with PE tube is used.

36 MATERIALS SCIENCE↗

Mode couplings in a two-stream free-electron laser with a helical wiggler and an ion-channel guiding

In this study, the method of perturbation has been applied to obtain the dispersion relation (DR) of a two-stream free-electron laser (FEL) with a helical wiggler and an ion-channel with all relativistic effects on waves. This DR has been solved numerically to find the unstable modes and their growth rate. Numerical solutions of DR show that the growth rate is considerably enhanced in comparison with single-stream free-electron laser. In group II orbits, with relatively large wiggler induced velocities, new couplings are found. The effect of the velocity difference of the two electron beams on the instabilities has also been investigated in this study. Moreover, the effect of the ion-channel density on the maximum growth rate of FEL resonance has been analyzed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron cyclotron beam measurement system in the Large Helical Device

In order to evaluate the electron cyclotron (EC) heating power inside the Large Helical Device vacuum vessel and to investigate the physics of the interaction between the EC beam and the plasma, a direct measurement system for the EC beam transmitted through the plasma column was developed. The system consists of an EC beam target plate, which is made of isotropic graphite and faces against the EC beam through the plasma, and an IR camera for measuring the target plate temperature increase by the transmitted EC beam. This system is applicable to the high magnetic field (up to 2.75 T) and plasma density (up to 0.8 × 10{sup 19} m{sup −3}). This system successfully evaluated the transmitted EC beam profile and the refraction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spin transport in helical biological systems

Motivated by the recent experimental demonstration of spin selective effects in monolayers of double-stranded DNA oligomers, our work presents a minimal model to describe electron transmission through helical fields. Our model highlight that the lack of inversion symmetry due to the chirality of the potential is a key factor which will lead to a high spin-polarization (SP). We also study the stability of the SP against fluctuations of the electronic structure induced by static disorder affecting the on-site energies. In the energy regions where the spin-filtering occurs, our results remain stable against moderate disorders although the SP is slightly reduced.

60 APPLIED LIFE SCIENCES↗

Magnetic turbulence and pressure gradient feedback effect of the 1/2 mode soft-hard magnetohydrodynamic limit in large helical device

The aim of this study was to analyze the feedback process between the magnetic turbulence and the pressure gradients in Large Helical Device (LHD) inward-shifted configurations as well as its role in the transition between the soft-hard magnetohydrodynamic (MHD) regimes for instabilities driven by the mode 1/2 in the middle plasma. In the present paper, we summarize the results of two simulations with different Lundquist numbers, S=2.5×10{sup 5} and 10{sup 6}, assuming a plasma in the slow reconnection regime. The results for the high Lundquist number simulation show that the magnetic turbulence and the pressure gradient in the middle plasma region of LHD are below the critical value to drive the transition to the hard MHD regime, therefore only relaxations in the soft MHD limit are triggered (1/2 sawtooth-like events) [Phys. Plasmas 19, 082512 (2012)]. In the case of the simulation with low Lundquist number, the system reaches the hard MHD limit and a plasma collapse is observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling, measurement, and 3-D equilibrium reconstruction of the bootstrap current in the Helically Symmetric Experiment

The bootstrap current for three electron cyclotron resonance heated plasma scenarios in a quasihelically symmetric stellarator (the Helically Symmetric Experiment) are analyzed and compared to a neoclassical transport code PENTA. The three conditions correspond to 50 kW input power with a resonance that is off-axis, 50 kW on-axis heating and 100 kW on-axis heating. When the heating location was moved from off-axis to on-axis with 50 kW heating power, the stored energy and the extrapolated steady-state current were both observed to increase. When the on-axis heating power was increased from 50 kW to 100 kW, the stored energy continued to increase while the bootstrap current slightly decreased. This trend is qualitatively in agreement with the calculations which indicate that a large positive electric field for the 100 kW case was driving the current negative in a small region close to the magnetic axis and accounting for the decrease in the total integrated current. This trend in the calculations is only observed to occur when momentum conservation between particle species is included. Without momentum conservation, the calculated bootstrap current increases monotonically. We show that the magnitude of the bootstrap current as calculated by PENTA agrees better with the experiment when momentum conservation between plasma species is included in the calculation. The total current was observed in all cases to flow in a direction to unwind the transform, unlike in a tokamak in which the bootstrap current adds to the transform. The 3-D inductive response of the plasma is simulated to predict the evolution of the current profile during the discharge. The 3-D equilibrium reconstruction code V3FIT is used to reconstruct profiles of the plasma pressure and current constrained by measurements with a set of magnetic diagnostics. The reconstructed profiles are consistent with the measured plasma pressure profile and the simulated current profile when the reconstruction is constrained by the measured data from a diagnostic array that is internal to the vacuum chamber.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In situ calibration of an infrared imaging video bolometer in the Large Helical Device

The InfraRed imaging Video Bolometer (IRVB) is a powerful diagnostic to measure multi-dimensional radiation profiles in plasma fusion devices. In the Large Helical Device (LHD), four IRVBs have been installed with different fields of view to reconstruct three-dimensional profiles using a tomography technique. For the application of the measurement to plasma experiments using deuterium gas in LHD in the near future, the long-term effect of the neutron irradiation on the heat characteristics of an IRVB foil should be taken into account by regular in situ calibration measurements. Therefore, in this study, an in situ calibration system was designed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of polarizers for a mega-watt long-pulse millimeter-wave transmission line on the large helical device

The polarizer is one of the critical components in a high-power millimeter-wave transmission line. It requires full and highly efficient coverage of any polarization states, high-power tolerance, and low-loss feature. Polarizers with rounded shape at the edge of the periodic groove surface are designed and fabricated by the machining process for a mega-watt long-pulse millimeter-wave transmission line of the electron cyclotron resonance heating system in the large helical device. The groove shape of λ/8- and λ/4-type polarizers for an 82.7 GHz transmission line is optimally designed in an integral method developed in the vector theories of diffraction gratings so that the efficiency to realize any polarization state can be maximized. The dependence of the polarization states on the combination of the two polarizer rotation angles (Φ{sub λ/8}, Φ{sub λ/4}) is examined experimentally in a low-power test with the newly developed polarization monitor. The results show that the measured polarization characteristics are in good agreement with the calculated ones.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗