At least 1,081 records · Page 60

Frequency Resilience Enhancement for Power Systems with High Penetration of Grid-Forming Inverters

Abstract—Grid following inverter-based renewable generation has replaced conventional generation in recent years, resulting in lower system inertia. The frequency resilience in such a lower inertia system is critical for emergency mitigation. In this paper, we propose a resilience metric based on frequency recovery to quantitatively represent system resilience in terms of the rate of change of frequency. Application of grid-forming converters provides a means to improve system resilience by providing virtual inertia. An under-frequency load shedding strategy is applied to further support frequency recovery in cases with high penetration of grid-forming inverters. Case studies are designed and performed in a modified IEEE 9-bus test system using the PSCAD/EMTDC platform. Simulation results demonstrate the validity of the proposed resilience metric and the effectiveness of the strategy for reducing frequency excursion in inverter-based power systems. citation: J. Gui, H. Lei, T. R. McJunkin and B. K. Johnson, "Frequency Resilience Enhancement for Power Systems with High Penetration of Grid-Forming Inverters," 2023 IEEE Power & Energy Society Innovative Smart Grid Technologies Conference (ISGT), Washington, DC, USA, 2023, pp. 1-5, doi: 10.1109/ISGT51731.2023.10066357.

14 SOLAR ENERGY↗

Modernizing Distribution System Restoration to Achieve Grid Resiliency Against Extreme Weather Events: An Integrated Solution

Recent severe power outages caused by extreme weather hazards have highlighted the importance and urgency of improving the resilience of the electric power grid. As the distribution grids still remain vulnerable to natural disasters, the power industry has focused on methods of restoring distribution systems after disasters in an effective and quick manner. The current distribution system restoration practice for utilities is mainly based on predetermined priorities and tends to be inefficient and suboptimal, and the lack of situational awareness after the hazard significantly delays the restoration process. As a result, customers may experience an extended blackout, which causes large economic loss. On the other hand, the emerging advanced devices and technologies enabled through grid modernization efforts have the potential to improve the distribution system restoration strategy. However, utilizing these resources to aid the utilities in better distribution system restoration decision-making in response to extreme weather events is a challenging task. Therefore, this paper proposes an integrated solution: a distribution system restoration decision support tool designed by leveraging resources developed for grid modernization. We first review the current distribution restoration practice and discuss why it is inadequate in response to extreme weather events. Then we describe how the grid modernization efforts could benefit distribution system restoration, and we propose an integrated solution in the form of a decision support tool to achieve the goal. The advantages of the solution include improving situational awareness of the system damage status and facilitating survivability for customers. The paper provides a comprehensive review of how the existing methodologies in the literature could be leveraged to achieve the key advantages. The benefits of the developed system restoration decision support tool include the optimal and efficient allocation of repair crews and resources, the expediting of the restoration process, and the reduction of outage durations for customers, in response to severe blackouts due to extreme weather hazards.

Automated feeder switch↗

Safeguarding the Grid: Diverse Resources for Resilience [In My View]

Reports on the vulnerability of the power grid. From wildfires, hurricanes, and floods to cyberattacks, the grid is vulnerable to natural and human-made disasters, which can cause widespread outages that last from hours to months and leave lasting economic impacts. Imagine a coastal region in the United States that has just been hit by a hurricane and lost all power. Besides the electricity infrastructure going out, communications networks, rail transportation, and gasoline pumps may also stop working after the emergency event, which often delays repair efforts to the grid. Unresponsive communications make it difficult to dispatch workers to repair the grid, and missing transportation links delay shipments of replacement equipment for the grid’s restoration.

cybersecurity↗

Grid Forming Inverter With Increased Short-Circuit Contribution to Address Inverter-Based Microgrid Protection Challenges

Substantial differences in fault levels between grid-tied and islanded modes is one of the primary challenges of microgrid protection. During grid-tied mode, the bulk grid provides significant short-circuit, while during islanded operation the short-circuit magnitude is small due to inverter-based resources limiting their current output close to nominal ratings. Consequently, conventional distribution protection strategies based on overcurrent cannot reliably protect microgrids when operating in islanded mode. Fuses and circuit breakers are particularly affected because of their inverse characteristics. Presently, the absence of affordable solutions for protecting microgrids in islanded mode leads to microgrids shutting down during electrical faults. The contribution of this article is two-fold. The first innovation proposes specific hardware modifications to grid-forming inverters to increase their short-circuit current during electrical faults. The second innovation introduces a novel control strategy designed to preserve control stability margins even when the grid-filter saturates, ensuring sinusoidal output currents under normal and fault conditions. Through experimental results, the inverter with the proposed modifications can provide more than three-times its nominal current during electrical faults. For the prototype testbed, this was sufficient to enable the use of traditional legacy overcurrent protection, achieving the fuse-to-relay and relay-to-relay minimum coordination time for the line-to-ground, line-to-line to ground, and three-phase electrical faults.

42 ENGINEERING↗

Grid Integration of Renewable Energy and Energy Storage

Grid integration of renewable energy and energy storage requires forward-looking planning process, and increased emphasizes on reliability, resilience, and equity. Power-electronics based energy generation including solar, wind, distributed energy resources (DERs), and various types of grid-tied energy storage and emerging loads, are reshaping grid operator's understanding on interconnection level performance and responses. This paper will present the ongoing work at PNNL related to power electronics R&D, energy modeling and analysis, and a wide spectrum of grid stability studies and technologies in support of grid integration of renewable energy and energy storage.

Power Electronics, grid integration of renewable e↗

A Transductive Graph Neural Network learning for Grid Resilience Analysis

Power grids are critical infrastructures that require robust resilience analysis to ensure reliable and uninterrupted electricity supply. Traditional simulation-based methods for grid resilience analysis suffer from computational complexity and limited ability to capture the full spectrum of potential disruptions. This paper presents a novel approach to enhance grid resilience by leveraging transductive graph neural network (GNN) learning to identify critical nodes and links. By leveraging the graph structure and system features, GNNs effectively learn resilience metrics and accurately identify critical nodes based on actual grid operational behavior. The efficacy of the proposed approach is demonstrated through case studies on node criticality scoring and critical node/line identification in cascading outage scenarios. The results highlight the advantages of learning-based methods over traditional simulation-based approaches and their potential to revolutionize grid resilience analysis. The contributions of this paper include a graph-based scalable approach for fast cascading analysis, an inductive formulation for training GNN models, and a transfer learning-based approach to scale the model to largescale power systems.

grid resilience, graph neural networks, transducti↗

Smart Grid Constraint Violation Management for Balancing and Regulating Purposes

The gradual active load penetration in low voltage distribution grids is expected to challenge their network capacity in the near future. Distribution system operators should for this reason resort to either costly grid reinforcements or to demand side management mechanisms. Since demand side management implementation is usually cheaper, it is also the favorable solution. To this end, this article presents a framework for handling grid limit violations, both voltage and current, to ensure a secure and qualitative operation of the distribution grid. This framework consists of two steps, namely a proactive centralized and subsequently a reactive decentralized control scheme. The former is employed to balance the one hour ahead load while the latter aims at regulating the consumption in real-time. In both cases, the importance of fair use of electricity demand flexibility is emphasized. Thus, it is demonstrated that this methodology aids in keeping the grid status within preset limits while utilizing flexibility from all flexibility participants.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transient Stability-Enhancing Method for Grid-Forming Inverters Under Current Limiting

The primary controller of a grid-forming (GFM) inverter governs the internal reference voltage and angle, which enables the inverter to naturally synchronize and share power with the connected grid; however, during disturbances on the grid caused by, e.g., line faults, overloading, or frequency and phase shifts, a GFM inverter can be pushed into a current-limited operation to protect the device against thermal damage. This can lead to a windup of the internal reference frequency generated by the primary controller and cause a total loss of synchronism with the grid. Here, to make the primary controller of GFM inverters more robust against transient instability, this paper proposes a method that manipulates the reference signals governed by the primary controller by introducing the concept of fictitious power. The fictitious power counteracts the integrator windup in the primary controller, which enables the current-limited inverter to conceive a stable operating point. This method is benchmarked against five state-of-the-art GFM inverter stabilization methods to evaluate its stability-enhancing performance. Full-order electromagnetic-transient simulations and experimental results of a hardware inverter test setup validate the benefits of the method to improve the transient stability of GFM inverters in the face of grid disturbances.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A New Type of Weak Grid IBR Oscillations

This letter presents the discovery of a new type oscillations associated with inverter-based resources (IBRs) in weak grids. While typical weak grid oscillations become worse when the grid strength decreases and the power exporting level increases, this new type of oscillations appear when the grid becomes weaker and the power exporting level decreases. Electromagnetic transient (EMT) simulation results are presented, along with eigenvalue loci for a varying power. The notable signatures of such oscillations are also remarked. In further analysis, a feedback system consisting of two blocks is derived with one block associated with the phase-locked-loop (PLL) and the other associated with the rest of the system. Here, this feedback system quantitatively demonstrates why insufficient damping in the PLL may be an issue for stability. Open-loop analysis shows that a larger phase lag in angle tracking in the low-frequency range due to high power exporting level at the weak grid condition is beneficial to the open-loop poles introduced by the PLL. And this is the reason why such oscillations may appear when power is ramping down.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Unified Model of Current-Limiting Grid-Forming Inverters for Large-Signal Analysis

Grid-forming (GFM) inverters can hardly withstand any overloading. As such, GFM inverters need a current limiter in their control system to avoid hardware damage during overloading or grid disturbances. When the current limiter is engaged for inverter protection, however, it dynamically changes the inverter output impedance, which can significantly affect the system behavior against large disturbances. For example, when the current limiter curtails the output power, the primary controller of the GFM inverter-which generates the voltage and angle reference-is prone to losing synchronization with the grid. This can cause large-signal instability in the network. This paper presents a unified GFM current-limiter model to gain a deeper understanding of the impact of the GFM inverter current limiting on large-signal instability and other system behaviors. The unified model captures several well-known current limiters for GFM inverters, and it reveals their large-signal equivalence characterized by the limiter angle. We use the unified model to present in-depth insights into the driving forces that cause large-signal instability in GFM inverter-driven grids. Further, this paper illustrates that the unified model can be used as a tool for assessing the system-level impacts of various GFM current-limiter designs during grid disturbances. Using numerical, analytical, electromagnetic transient models, and a hardware setup, the validity of the unified model is evaluated.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis on the Influence of an Energy Storage System and its Impact to the Grid for a Wave Energy Converter

Reducing power fluctuations is essential for controlling the integration impacts of wave energy converter (WEC) plants in both distribution and transmission grids, and in stand-alone isolated power systems. This paper presents an analysis on the cost of and how a battery storage system can be used to further reduce the variation of power generated from the WEC due to the fluctuating nature of waves and its impact to the grid. The electrical power output from WEC-Sim simulations for the six sea states used in the Wave Energy Prize was analyzed to compute the peak power and power time history. The results were used to evaluate the battery storage capacity that is needed for a WEC system to provide reasonable power flow to the grid and estimate its cost based on the latest cost information for battery technologies published by the U.S. Energy Information Administration. Finally, a preliminary grid integration analysis was performed to demonstrate how WEC-generated power would contribute to a small island electricity system. As shown in the study, the instantaneous peak power is the primary cost driver for the battery storage and the power take-off system, and reducing the power fluctuations is essential for reducing the overall levelized cost of energy (LCOE). The power flow variation from WECs can be significantly reduced using battery storage without adding significant overall system costs, and the implementation of battery storage is essential for grid integration applications. There may also be additional opportunities to further investigate energy storage technologies that are specific to WEC applications to reduce these costs even further.

16 TIDAL AND WAVE POWER↗

Optimal net-load balancing in smart grids with high PV penetration

Mitigating mismatches in supply demand curve is critical for smooth power grid operation. Traditionally, load curtailment techniques such as Demand Response (DR) have been used for this purpose. However, smart grids with high PV penetration sometimes exhibit supply surplus causing over-voltages. Thus, load curtailment techniques cannot be the only component of a net-load balancing framework. Supply curtailment techniques such as Volt-Var Optimizations are complex and computationally expensive. This increases the complexity of net-load balancing systems used by the grid operator and limits their scalability. Recently, new technologies have been developed that enable the rapid and selective connection of PV modules of an installation to the grid. Taking advantage of these advancements, we develop a unified optimal net-load balancing framework which performs both load and solar curtailment. We show that when the available curtailment values are discrete, this problem is NP-hard and develop bounded approximation algorithms for minimizing the curtailment cost. Our algorithms produce fast solutions, given the tight timing constraints required for grid operation. We also incorporate the notion of fairness to ensure that curtailment is evenly distributed among all the nodes. Finally, we develop an online algorithm which performs net-load balancing using only data available for the current interval. Using both theoretical analysis and practical evaluations, we show that our net-load balancing algorithms provide solutions which are close to optimal in a small amount of time.

14 SOLAR ENERGY↗

Grid Architecture 2

The report describes work done on Grid Architecture under the auspices of the Department of Electricity Office of Electricity Delivery and Reliability in 2015. As described in the first Grid Architecture report, the primary purpose of this work is to provide stakeholder insight about grid issues so as to enable superior decision making on their part. Doing this requires the creation of various work products, including oft-times complex diagrams, analyses, and explanations. This report provides architectural insights into several important grid topics and also describes work done to advance the science of Grid Architecture as well.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of a Hydrogen Energy System as a Grid Frequency Management Tool

The Hawai‘i Natural Energy Institute (HNEI) is conducting research to assess the technical potential of using an electrolyzer-based hydrogen (H2) production and storage system as a grid demand response tool using battery data from a 200 MW grid to show the kind of response required. The hydrogen produced by the electrolyzer is used for transportation. A 65 kg/day hydrogen energy system (HES) consisting of a PEM electrolyzer, 35 bar buffer tank, 450 bar compressor, and associated chiller systems was purchased and installed at the Hawaii Natural Energy Laboratory Hawaii Authority (NELHA) to demonstrate long-term durability of the electrolyzer under cyclic operation required for frequency regulation on an island grid system. The excess hydrogen was stored for use by three fuel-cell buses to be operated at Hawai‘i Volcanoes National Park (HAVO) and by the County of Hawai‘i Mass Transit Agency (MTA). This paper describes the site selection and equipment commissioning, plus a comprehensive test plan that was developed to characterize the performance and durability of the electrolyzer under dynamic load conditions. The controls were modified for the operating envelope and dynamic limits of the electrolyzer. While the data showed these modifications significantly improved the system response time, it is not fast enough to match a BESS response time for grid frequency management. The electrolyzer can only be used for slower acting changes (1 to 0.5 Hz). A potential solution is to design an electrolyzer/BESS hybrid system and develop a modeling program to find the optimum mix of battery and electrolyzer to provide the maximum grid regulation services at minimum cost.

08 HYDROGEN↗

Comparison of Standards and Technical Requirements of Grid-Connected Wind Power Plants in China and the United States

The rapid deployment of wind power has made grid integration and operational issues focal points in industry discussions and research. Compliance with grid connection standards for wind power plants (WPPs) is crucial to ensuring the reliable and stable operation of the electric power grid. This report compares the standards for grid-connected WPPs in China to those in the United States to facilitate further improvements in wind power standards and enhance the development of wind power equipment. Detailed analyses of power quality, low-voltage ride-through capability, active power control, reactive power control, voltage control, and wind power forecasting are provided to enhance the understanding of grid codes in the two largest markets of wind power. This study compares WPP interconnection standards and technical requirements in China to those in the United States.

17 WIND ENERGY↗

Grid Ready: Strategies for Interconnecting Large-Scale PV in New York City

This Grid Ready Solar project is intended to help create transparency for building owners and developers, so they can better understand and more quickly navigate the interconnection process for large-scale photovoltaic (PV) projects on Con Edison's electrical grid in New York City. Phase 1 of the project provided high-level technical screens of grid interconnection requirements in an attempt to streamline the interconnection of large-scale solar PV systems to the New York City grid. In Phase 2 of the Grid Ready project, the focus of this report, Sustainable CUNY worked with NREL to evaluate a range of solutions for improving the economics of large-scale (over 200 kW) PV within the five boroughs of New York City that are in Con Edison's service territory, as identified on the NY Solar Map.

14 SOLAR ENERGY↗

Valuation of Hydrogen Technology on the Electric Grid Using Production Cost Modeling: Cooperative Research and Development Final Report, CRADA Number CRD-18-00736

This research project will estimate the value to the United States electric grid of deploying hydrogen technology (such as electrolyzers and hydrogen-fueled generation) under projected conditions of high renewable penetration. The analysis will advance the state of the art in systems-level cost-benefit analysis of hydrogen technology for the electric grid by incorporating production cost modeling results in the analysis. Large-scale grid simulation tools will be used to evaluate total system production cost and grid operation when hydrogen technology is deployed for applications such as energy storage and demand response. Scenarios will include one or more future grid mixes in the Western Interconnect (WI) with a high proportion of intermittent renewables. Electric Power Research Institute (EPRI) will work with four utility companies to refine scenarios. Results of the analysis will include comparing the net cost of hydrogen to other technologies for long duration storage, and of power-to-gas (P2G) scenarios including merchant hydrogen sale and hydrogen-fueled generation.

08 HYDROGEN↗

Multi-Fidelity Stochastic Economic Dispatch for Operating Low Carbon Power Grids

Grid operators can address the inherently stochastic nature of renewables by solving a two-stage stochastic programming model that minimizes the cost of dispatch decisions while accounting for the complex grid dynamics. It is common to use a sample average approximation to estimate the expectation of the second stage costs in this model. However, the large sample count needed for numerical accuracy makes effective modeling large-scale electric grids computationally intractable. We introduce a control variate multi-fidelity estimator for the second-stage recourse that enables high quality dispatch decisions in real-time with a reduced computational burden. We obtain a hierarchy of model fidelities by linearizing the AC power flow system representation to DC power flow, and by relaxing transmission and voltage network constraints. We evaluate the performance of our proposed method on a synthetic grid with 73 buses against a deterministic baseline with persistence forecast and a high-fidelity reference. Our analysis shows a computational speed-up of 7.62x with a minimal loss in accuracy. The multi-fidelity method is well suited to fidelity combinations that use a simplified network topology in their lower fidelity model and is an attractive option for applications where accurate grid modeling needed on a limited computational budget.