Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Germanium”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Experimental Developments for the Lamb Shift Investigation in Heavy Ions

Novel high-resolution spectrometer setups are presently commissioned for X-ray experiments at the Experimental Storage Ring (ESR) at GSI, Darmstadt, aiming at an accurate determination of QED corrections in the critical field limit via an accurate determination of the ground-state binding energy in a high-Z, H-like ion. Until now for H-like uranium, an accuracy of 1% could be reached in an experiment performed at the electron cooler, due to the deceleration capability of the ESR. A further improvement by almost one order of magnitude is envisaged by a transmission x-ray spectrometer setup in the FOcusing Compensated Asymmetric Laue (FOCAL) geometry, as well as by the implementation of high-resolution microcalorimeter devices.Here we report on the latest commissioning experiment of a two-arm transmission X-ray spectrometer, along with high-performance position-sensitive microstrip germanium detectors. Due to a photon efficiency of only 10{sup -8}, the position sensitivity, as well as the energy and time resolution of segmented solid-state germanium detectors, are absolutely essential for the experiment. In combination with the FOCAL spectrometer, these position-sensitive detectors permit the simultaneous measurement of all energies in the regime of interest.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solid Xenon Project

Crystals like Germanium and Silicon need to be grown in specialized facilities which is time and money costly. It takes many runs to test the detector once it's manufactured and mishaps are very probable. It is of a great challenge to grow big germanium crystals and that's why stacking them up in a tower is the only way at the moment to increase testing mass. Liquid Noble gas experiments experiencing contamination problems, their predicted energy resolution at 10 keV and lower energy range is not as good as predicted. Every experiment is targeting one specific purpose, looking for one thing. Why not to design an experiment that is diverse and build a detector that can search for Dark Matter, Solar Axions, Neutrinoless Double Beta decay, etc. Solid Xenon detector is such detector. We designed a simple Xenon crystal growing chamber that was put together at Fermi National Accelerator Laboratory. The first phase of this experiment was to demonstrate that a good, crack free Xenon crystal can be grown (regardless of many failed attempts by various groups) and our first goal, 1 kg crystal, was successful.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of near-stability nuclei populated as fission fragments in heavy-ion fusion reactions

Examples are presented to illustrate the power of prompt {gamma}-ray spectroscopy of fission fragments from compound nuclei with A{approx}200 formed in fusion-evaporation reactions in experiments using the Gammasphere Ge-detector array. Complementary methods, such as Coulomb excitation and deep-inelastic processes, are also discussed. In other cases (n,xn{gamma}) reactions on stable isotopes have been used to establish neutron excitation functions for {gamma}-rays using a pulsed 'white'-neutron source, coupled to a high-energy-resolution germanium-detector array. The excitation functions can unambiguously assign {gamma}-rays to a specific reaction product. Results from all these methods bridge the gaps in the systematics of high-spin states between the neutron-deficient and neutron-rich nuclei. Results near shell closures should motivate new shell model calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

GIOVE, a shallow laboratory Ge-spectrometer with 100 μBq/kg sensitivity

A new germanium gamma spectrometer called GIOVE (Germanium spectrometer with Inner and Outer Veto) has been set up at the underground/shallow laboratory (15 m w.e.) of MPI-K. Its double plastic scintillator veto system and neutron moderation interlayer lower the background by more than one order of magnitude compared to the other existing spectrometer at this facility. The integral (40-2700 keV) background rate of about 290 counts (day kg){sup −1} is just a factor 4 to 8 above that of the GeMPI spectrometers operated at LNGS (3800 m w.e.) and thus proves that even under shallow overburden sub mBq/kg sensitivities are achievable. Extended material screening and neutron attenuation studies preceded the final design of the spectrometer. The technical realization of the spectrometer is described in detail with special emphasis on the inner veto system. For its optimisation a simulation model was developed for light collection on small low activity PMT’s under various geometrical conditions. Radon suppression is accomplished by employing a gas tight sample container and a nitrogen flushed glove-box system with an airlock. The active volume of the crystal was modelled by absorption scanning measurements and Monte Carlo simulations. The complete shield is implemented in a Geant4 based simulation framework.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low background counting techniques at SNOLAB

Many of the experiments currently searching for dark matter, studying properties of neutrinos or searching for neutrinoless double beta decay require very low levels of radioactive backgrounds both in their own construction materials and in the surrounding environment. These low background levels are required so that the experiments can achieve the required sensitivities for their searches. SNOLAB has several facilities which are used to directly measure these radioactive backgrounds. This proceedings will describe SNOLAB's High Purity Germanium Detectors, one of which has been in continuous use for the past seven years measuring materials for many experiments in operation or under construction at SNOLAB. A description of the characterisation of SNOLAB's new germanium well detector will be presented. In addition, brief descriptions of SNOLAB's alpha-beta and electrostatic counters will be presented and a description of SNOLAB's future low background counting laboratory will be given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-resolved measurements of the hot-electron population in ignition-scale experiments on the National Ignition Facility (invited)

In laser-driven inertial confinement fusion, hot electrons can preheat the fuel and prevent fusion-pellet compression to ignition conditions. Measuring the hot-electron population is key to designing an optimized ignition platform. The hot electrons in these high-intensity, laser-driven experiments, created via laser-plasma interactions, can be inferred from the bremsstrahlung generated by hot electrons interacting with the target. At the National Ignition Facility (NIF) [G. H. Miller, E. I. Moses, and C. R. Wuest, Opt. Eng. 43, 2841 (2004)], the filter-fluorescer x-ray (FFLEX) diagnostic–a multichannel, hard x-ray spectrometer operating in the 20–500 keV range–has been upgraded to provide fully time-resolved, absolute measurements of the bremsstrahlung spectrum with ∼300 ps resolution. Initial time-resolved data exhibited significant background and low signal-to-noise ratio, leading to a redesign of the FFLEX housing and enhanced shielding around the detector. The FFLEX x-ray sensitivity was characterized with an absolutely calibrated, energy-dispersive high-purity germanium detector using the high-energy x-ray source at NSTec Livermore Operations over a range of K-shell fluorescence energies up to 111 keV (U K{sub β}). The detectors impulse response function was measured in situ on NIF short-pulse (∼90 ps) experiments, and in off-line tests.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a broadband reflectivity diagnostic for laser driven shock compression experiments

Here, a normal-incidence visible and near-infrared shock wave optical reflectivity diagnostic was constructed to investigate changes in the optical properties of materials under dynamic laser compression. Documenting wavelength- and time-dependent changes in the optical properties of laser-shock compressed samples has been difficult, primarily due to the small sample sizes and short time scales involved, but we succeeded in doing so by broadening a series of time delayed 800-nm pulses from an ultrafast Ti:sapphire laser to generate high-intensity broadband light at nanosecond time scales. This diagnostic was demonstrated over the wavelength range 450–1150 nm with up to 16 time displaced spectra during a single shock experiment. Simultaneous off-normal incidence velocity interferometry (velocity interferometer system for any reflector) characterized the sample under laser-compression and also provided an independent reflectivity measurement at 532 nm wavelength. The shock-driven semiconductor-to-metallic transition in germanium was documented by the way of reflectivity measurements with 0.5 ns time resolution and a wavelength resolution of 10 nm.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Schottky diodes from 2D germanane

We report on the fabrication and characterization of a Schottky diode made using 2D germanane (hydrogenated germanene). When compared to germanium, the 2D structure has higher electron mobility, an optimal band-gap, and exceptional stability making germanane an outstanding candidate for a variety of opto-electronic devices. One-atom-thick sheets of hydrogenated puckered germanium atoms have been synthesized from a CaGe{sub 2} framework via intercalation and characterized by XRD, Raman, and FTIR techniques. The material was then used to fabricate Schottky diodes by suspending the germanane in benzonitrile and drop-casting it onto interdigitated metal electrodes. The devices demonstrate significant rectifying behavior and the outstanding potential of this material.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low background materials and fabrication techniques for cables and connectors in the Majorana Demonstrator

Here, the Majorana Collaboration is searching for the neutrinoless double-beta decay of the nucleus 76 Ge. The Majorana Demonstrator is an array of germanium detectors deployed with the aim of implementing background reduction techniques suitable for a tonne scale 76 Ge-based search (the LEGEND collaboration). In the Demonstrator, germanium detectors operate in an ultra-pure vacuum cryostat at 80 K. One special challenge of an ultra-pure environment is to develop reliable cables, connectors, and electronics that do not significantly contribute to the radioactive background of the experiment. This paper highlights the experimental requirements and how these requirements were met for the Majorana Demonstrator, including plans to upgrade the wiring for higher reliability in the summer of 2018. Also described are requirements for LEGEND R&D efforts underway to meet these additional requirements

74 ATOMIC AND MOLECULAR PHYSICS↗

Photo-induced enhancement of the dark conductivity in nanocrystalline germanium/amorphous silicon composite thin films

A light-induced increase in the dark conductivity is observed in composite thin films consisting of hydrogenated amorphous silicon (a-Si:H) containing nanocrystalline germanium (nc-Ge) inclusions, synthesized by co-deposition in a dual-chamber plasma enhanced chemical vapor deposition system. Unlike the Staebler-Wronski effect or persistent photoconductivity observed in amorphous semiconductors, this photo-induced excess conductivity is observed even in composite nc-Ge/a-Si:H films with a minimal photosensitivity. The decay of the excess conductivity follows a single-exponential time dependence, with a temperature independent time constant. We propose that spatial separation of photo-excited charge carriers by the compositional morphology present in the film, with tunneling of photo-excited holes into the germanium nanocrystalline inclusions, is involved in the creation and removal of this effect.

Nangoi, J. K.↗

Recent results of the Majorana Demonstrator experiment

The Majorana Demonstrator is searching for neutrinoless double-beta decay in 76Ge with two modular arrays of natural and 76Ge-enriched germanium detectors. It is located at the 4850' level of Sanford Underground Research Facility in Lead, South Dakota, USA, and its total mass of germanium detectors is 44.1 kg, of which 29.7 kg is enriched. The analysis of the first 26 kg-yr of data provides an unprecedented energy resolution of 0.13% in the region of interest at 2039 keV and a background level of 15.4 ±2.0 counts/(FWHM t yr). It establishes the lower limit of the half-life of neutrinoless double beta decay as 2.7 1025 yr in 76Ge at 90% CL. This analysis will be summarized here with an emphasis on the energy determination.

López-Castaño, JM↗

Electrical, optical, and magnetic properties of amorphous yttrium iron oxide thin films and consequences for non-local resistance measurements

We present magnetic characterization, charge resistivity, and optical photoluminescence measurements on amorphous yttrium iron oxide thin films ( ⁠a-Y–Fe–O), with supporting comparisons to amorphous germanium (⁠ a-Ge) films. We measured magnetic properties with both SQUID magnetometry and polarized neutron reflectometry. These results not only confirm that a-Y–Fe–O is a disordered magnetic material with strong predominantly antiferromagnetic exchange interactions and a high degree of frustration, but also that it is best understood electrically as a disordered semiconductor. As with amorphous germanium, a-Y–Fe–O obeys expectations for variable-range hopping through localized electron states over a wide range of temperature. We also clarify the consequences of charge transport through such a semiconducting medium for non-local voltage measurements intended to probe spin transport in nominally insulating magnetic materials. We further compare non-local resistance measurements made with “quasi-dc” automated current reversal to ac measurements made with a lock-in amplifier. These show that the “quasi-dc” measurement has an effective ac current excitation with frequency up to approximately 22 Hz, and that this effective ac excitation can cause artifacts in these measurements including incorrect sign of the non-local resistance. Here, this comprehensive investigation of non-local resistance measurements in a-Y–Fe–O shows no evidence of spin transport on micrometer length scales, which is contrary to our original work, and in line with more recent investigations by other groups.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Modeling backgrounds for the majorana demonstrator

The MAJORANA DEMONSTRATOR is a neutrinoless double-beta decay (0?ß ß ) experiment containing ~30 kg of p-type point contact germanium detectors enriched to 88% in 76Ge and ~14 kg of natural germanium detectors. The detectors are housed in two electroformed copper cryostats and surrounded by a graded passive shield with active muon veto. An extensive radioassay campaign was performed prior to installation to insure the use of ultra-clean materials. The DEMONSTRATOR achieved one of the lowest background rates in the region of the 0?ß ß Q-value, 15.7 ± 1.4 cts/(FWHM t y) from the low-background configuration spanning most of the 64.5 kg-yr active exposure. Nevertheless this background rate is a factor of five higher than the projected background rate. This discrepancy arises from an excess of events from the 232Th decay chain. Background model fits aim to understand this deviation from assay-based projections, potentially determine the source(s) of observed backgrounds, and allow a precision measurement of the two-neutrino double-beta decay half-life. The fits agree with earlier simulation studies, which indicate the origin of the 232Th excess is not from a near-detector component and have informed design decisions for the next-generation LEGEND experiment. Recent findings have narrowed the suspected locations for the excess activity, motivating a final simulation and assay campaign to complete the background model.

Haufe, Christopher R.↗

Phonon-mediated quantum efficiency measurement in semiconductors

Accurate quantum efficiency measurement not only provides crucial information for the photovoltaic cell industry but also supports experiments aimed at directly detecting dark matter and elastic neutrino interactions. The dark matter direct searches paradigm has recently expanded to include particles with masses below 1,MeV/c2, where the expected signal in an electron–recoil interaction is approximately in the eV range, just above the energy gap for silicon and germanium. A robust calibration method for ionization signals in this lower energy region is essential. This paper presents a method for measuring quantum efficiency and yield (q/E) in semiconductors using phonon-mediated calorimetry. The Neganov–Trofimov–Luke phonon amplification method in low-temperature semiconductor crystals has been employed to indirectly measure ionization down to single-electron accuracy. Specifically, at zero bias, the phonon readout directly quantifies the total energy deposited within the detector, independent of the ionization yield. This eliminates a significant source of systematic uncertainty in quantum efficiency estimates associated with total energy uncertainty. The paper includes results from an updated ionization efficiency measurement in a germanium detector.

Physics↗

Study of phase decoherence in GeSn (8%) through measurements of the weak antilocalization effect

Alloying germanium with tin offers a means to modulate germanium's electronic structure, enabling a greater degree of control over quantum properties such as the retention of the phase or spin of the electron wave. However, the extent to which the presence of high dopant concentrations in GeSn alters these quantum behaviors is poorly understood. Here, we investigate the role of dopant concentrations on phase coherence through measurements of the weak antilocalization (WAL) effect at temperatures between 30 mK and 10 K in p-GeSn (8%) thin films, which were doped to a series of carrier densities on the order of 10 12 cm –2 . Phase coherence and spin–orbit lengths were extracted from the magnetoconductivities using the 2D Hikami–Larkin–Nagaoka model. Phase coherence lengths peaked at 577, 593, and 737 nm for the low-, mid-, and high-density samples, while upper limits on the spin–orbit lengths of less than 25 nm were relatively independent of carrier density and temperature. The phase coherence lengths increased as the temperature decreased but changed only minimally with carrier density, contrary to common models of temperature-dependent inelastic scattering. Saturation of the phase coherence lengths occurred below 600 mK. Based on these findings, intrinsically generated inelastic scattering mechanisms such as two-level systems or impurity band scattering likely contribute to phase decoherence in these alloys. Our results provide insight into the inelastic scattering mechanisms of GeSn, while suggesting a need for further investigation into phase decoherence mechanisms in doped group-IV alloys.

42 ENGINEERING↗

Design improvements to cables and connectors in the Majorana Demonstrator

The Majorana Demonstrator is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a ton-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and 76 Ge-enriched germanium p-type point contact detectors totaling 44.1 kg, located at the 4850 level of the Sanford Underground Research Facility in Lead, South Dakota, USA. The Demonstrator uses custom high voltage cables to bias the detectors, as well as custom signal cables and connectors to read out the charge deposited at the point contact of each detector. These low-mass cables and connectors must meet stringent radio purity requirements while being subjected to thermal and mechanical stress. A number of issues have been identified with the currently installed cables and connectors. An improved set of cables and connectors for the Majorana Demonstrator are being developed with the aim of increasing their overall reliability and connectivity. In conclusion, we will discuss some of the issues encountered with the current cables and connectors as well as our improved designs and their initial performance.

42 ENGINEERING↗

Dark matter sensitivities of the Majorana Demonstrator

The Majorana Demonstrator is an array of natural and enriched high purity germanium detectors that will search for the neutrinoless double-beta decay of Germanium-76 and perform a search for weakly interacting massive particles with masses below 10 GeV. To reach the background rate goal in the neutrinoless double-beta decay region of interest of 4 counts/keV/t/y, the DEMONSTRATOR will utilize a number of background reduction strategies, including a time-correlated event cut for 68Ge that requires a sub-keV energy threshold. This low energy threshold allows the DEMONSTRATOR to extend its physics reach to include a search for light WIMPs. We will discuss the detector systems and data analysis techniques required to achieve sub-keV thresholds as well as present the projected dark matter sensitivities of the Majorana Demonstrator.

Giovanetti, G. K.↗

Investigation of ASIC-based signal readout electronics for LEGEND-1000

LEGEND, the Large Enriched Germanium Experiment for Neutrinoless ββ Decay, is a ton-scale experimental program to search for neutrinoless double beta (0νββ) decay in the isotope 76 Ge with an unprecedented sensitivity. Building on the success of the low-background 76 Ge-based GERDA and Majorana Demonstrator experiments, the LEGEND collaboration is targeting a signal discovery sensitivity beyond 10 28 yr on the decay half-life with approximately 10 t∙yr of exposure. Signal readout electronics in close proximity to the detectors plays a major role in maximizing the experiment's discovery sensitivity by reducing electronic noise and improving pulse shape analysis capabilities for the rejection of backgrounds. However, the proximity also poses unique challenges for the radiopurity of the electronics. Application-specific integrated circuit (ASIC) technology allows the implementation of the entire charge sensitive amplifier (CSA) into a single low-mass chip while improving the electronic noise and reducing the power consumption. In this work, we investigated the properties and electronic performance of a commercially available ASIC CSA, the XGLab CUBE preamplifier, together with a p-type point contact high-purity germanium detector. We show that low noise levels and excellent energy resolutions can be obtained with this readout. Moreover, we demonstrate the viability of pulse shape discrimination techniques for reducing background events.

47 OTHER INSTRUMENTATION↗