WISP: Watching grid Infrastructure Stealthily through Proxies (Final Technical Report)

The complex interdependencies of cyber systems (sensors and communications), physical grids and associated electricity market operations make protecting electric power grids a significant challenge. The energy sector is constantly under new, targeted, advanced and dangerous cyber-attacks that have the potential to result in the loss of human life. These threats are further exacerbated by our need to modernize the grid. One focus of cyber security research in smart grids is the securing of the SCADA system through advanced intrusion detection systems (IDS) and bad data detection algorithms in state estimation. These methods either require full knowledge of the system topology and parameters or fail to understand the physical behaviors under attack. WISP (Watching grid Infrastructure Stealthily through Proxies) is designed to provide additional protection to the power grid using only publicly available data. In particular, WISP exploits the spatio-temporal nature of the real time locational marginal prices (LMPs), in conjunction with other information such as bids, weather, outages and load data to analyze anomalous power pricing behaviors and then correlate those observations to localize regions of interest and identify potential cyber events. WISP is non-intrusive as the tool is deployed as a service in the Cloud or on premise and provides reliable information to system operators for enhanced situational awareness, without impeding energy delivery functions. The WISP technology comprises three modules: the data-driven anomaly detection core, the vulnerability and risk analysis and the root cause analysis. The data-driven anomaly detection core performs the tasks of feature selection, anomaly detection and attack region localization. The vulnerability and risk analysis module provides system level information of the vulnerable variables and times, assisting the operators in selecting monitoring and protection nodes. The root cause analysis module takes the detection results and identifies potential operational conditions that contribute to the detected anomalies. In Phase I, we have demonstrated the feasibility and effectiveness of WISP. We developed a realistic electricity market simulator capable of generating normal and attack market data under various operational conditions. We developed a series of cyber-attack detection and analysis algorithms and evaluated them under multiple data sources. Finally, we integrated all modules into an end-to-end software, providing functions for data management, data analytics and visualization. Specifically, we have achieved: (i) real-time data acceptance from external utility interfaces with >99% acceptance rate; (ii) high performance anomaly detection algorithms with >98% detection accuracy and <0.1% false alarm rate; and (iii) ultra-low computing delay <50 milliseconds. Additionally, our team developed algorithms to identify the vulnerable variables in electricity market operations and root cause analysis functions to identify major contributors to the price spikes. These ancillary modules are necessary when deploying WISP in real world industry environment. In Phase II, we have demonstrated the effectiveness of WISP software on realistic largescale power systems. We performed red team testing for the Phase I WISP software and identified software vulnerabilities and implemented corresponding mitigation solutions. We adapted the electricity market simulator for the Texas synthetic 2000-bus system and generated datasets for the false data injection attacks. We created database and visualization interfaces for the Texas system and the ISO New England system. We performed software optimization in terms of operation efficiency, computing speed and detection accuracy. Finally, we tested the software on the Texas system and the ISO New England system and evaluated the detection performance. Overall, we achieved above 89% detection rate, below 3% false alarm rate and below 37 seconds of end-to-end detection delay.

24 POWER TRANSMISSION AND DISTRIBUTION↗

CRADA Number NFE-19-07846 with Grid Fruit, LLC (CRADA Final Report)

Cooperative Research and Development Agreement (CRADA) NFE-19-07846 between Oak Ridge National Laboratory (ORNL) and Grid Fruit, LLC (Grid Fruit) focused on simulating, monitoring, and adjusting controls of commercial refrigerator and freezer systems to provide load flexibility and demand response services from these machines. Viewing these medium and low-temp coolers as thermal masses, the volumes of chilled air in these coolers make them time-shiftable loads ripe for deployment at optimal times. Grid Fruit is a startup company developing methods to schedule the chilling cycles (e.g., in “build load” and “shed load” grid events) to provide energy efficiency, peak shifting, and other benefits both to the grid and the broader environment. These benefits can be magnified by coordinating chillers with HVAC, lights, computers, and other loads. Grid Fruit completed simulations and then selected and ordered controls hardware to prove the technology were successful, but the diversity of chiller models in the field without digital controls, as well as limited market demand at present, make further exploration necessary before commercialization.

42 ENGINEERING↗

Survey and Benchmark of Benefits of High Voltage SiC Applications in Medium Voltage Power Distribution Grids

The main objective of this survey and benchmark study is to identify and document potential high-impact applications in today's and future medium voltage (MV) distribution grids that will significantly benefit from high voltage (HV) (i.e. > 3.3 kV) SiC-based power electronics equipment. In particular, it is desirable to identify applications that can utilize the high switching speed and high control bandwidth enabled by SiC-based equipment. Specifically, the benefits of using SiC are quantified through the benchmark analysis and design using simulation for the selected high-impact applications. In addition, to provide grid support services, it is necessary to consider grid requirements in the grid-connected converter's design. Therefore, the impact of grid requirements on the HV SiC-based grid-connected converter is evaluated.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Vehicle-to-Grid Electric School Bus Commercialization Project

The Vehicle-to-Grid Electric School Bus Commercialization Project was chartered to advance the idea that the batteries in electric vehicles can play a valuable role in supporting the electric grid. As deployment of wind and solar generating resources accelerates to provide an ever-greater share of the nation’s electricity, concurrent investment in solutions that can offset their inherent intermittency will be necessary. Many types of energy storage systems have been proposed, and more than one type will find an economic fit in the grid of the future. Electric vehicle batteries have the potential to provide grid support services in an advantaged manner. The project’s method of exploring this proposition called for development and demonstration of a fleet of vehicle-to-grid (V2G) electric school buses. School buses were chosen because their energy storage capacity is large relative light-duty vehicles; they are typically domiciled in fleet settings; and the number of hours per year they are available for grid support services is high on an absolute basis (generally 80-85% of the hours in a year) and relative to other categories of medium- and heavy-duty vehicles.

33 ADVANCED PROPULSION SYSTEMS↗

Grid-Integrated Production of Fischer-Tropsch Synfuels from Nuclear Power

Idaho National Laboratory (INL) investigates the relative economic profitability of an integrated energy system (IES) coupling an NPP with a synfuel production process at selected case study locations across the United States. In the synfuel IES, a high-temperature steam electrolysis (HTSE) plant is thermally and electrically coupled with an NPP to produce zero-carbon hydrogen. The synthetic fuel is produced from this H 2 combined with a CO 2 supply using the reverse water gas shift process followed by the Fischer-Tropsch (FT) reaction. This analysis considers a system in which the CO 2 is sourced from regional CO 2 emitters via the construction and operation of pipeline-based CO 2 supply networks. Locating the FT plant at the same site as the NPP and HTSE plants enables the NPP to provide zero-carbon heat and power to the HTSE plant and zero-carbon power to the FT plant as well as avoid the requirement for long-distance H 2 product transport from the HTSE plant to the FT plant. Hydrogen storage is used to enable the NPP to dispatch power to the electrical grid (instead of the HTSE plant) when grid demand increases, thus enabling the FT plant to continue to operate in a steady-state production mode. The ability to cease hydrogen production for several hours within each day enables the NPP to provide power to the grid to balance the electricity market during peak periods and maximize revenues for the nuclear synfuel IES. The FT process design considered has a 99% carbon conversion efficiency. The use of nuclear energy and nuclear energy-derived hydrogen enables synfuel production to achieve this high level of carbon utilization. Additionally, the life-cycle carbon emissions of the nuclear-based synfuel production process are very low, with WTW emissions of approximately 25 gCO 2 e/MJ, including steam credits (generated from FT process excess heat), and approximately 7 gCO 2 e/MJ, if steam credits are excluded. This compares favorably with the WTW emissions of 90.5 gCO 2 e/MJ for a compression-ignition, direct injection (CIDI) vehicle with a fuel economy of 31.6 miles per gallon gasoline equivalent (MPGGE), using low-sulfur diesel produced using conventional petroleum production and refining processes. Several NPPs in various regions of the U.S. are considered as case study analyses. Supply locations and transportation via pipeline of the CO 2 feedstock to the NPP site are analyzed through the National Energy Technology Laboratory (NETL) CO 2 Transport Cost model. The team finds that the amount of CO 2 generated by different sectors is sufficient for the synfuel production process at all locations considered. The CO 2 transportation costs are functions of the distance of the source to the NPP location, the CO 2 capture cost at the source, and the quantity of CO 2 transported. Historical electricity prices for the NPP case study locations are collected and analyzed. Monthly average prices, price range, and duration of negative-price periods vary among these locations. For each location, an auto-regressive moving average (ARMA) model is trained on historical electricity price data. ARMA validation is done to ensure the synthetic price distributions represent one of historical prices with high fidelity. Synthetic time series from these ARMA models are used in a coupled dispatch and system optimization in the Holistic Energy Resource Optimization Network (HERON) to compute the differential net present value (NPV) of the IES. The team finds that this econometric is positive, ranging from $14M–1.3bn (2020) depending on the location. The optimal synfuel IES configuration to obtain this increase in NPV often maximizes the size of the synfuel production process with regards to the size of the NPP. However, the team shows that the NPP still plays a stabilizing role for the grid: In periods of high prices and high loads, more electricity from the NPP is sent to the grid. A high variability of electricity prices and extreme maximum prices tend to drive up electricity production. While it requires significant investment, the synfuel IES could increase the economic profitability for the existing fleet of LWRs across the country while still maintaining the grid stabilizer role of NPPs. During its lifetime, the main costs for the nuclear synfuel IES are the carbon feedstock transportation costs, followed by the capital expenses (CAPEX) and operation and maintenance (O&M) costs while the revenue comes first from the IRA H 2 production tax credit (PTC) and then from the sales of synfuel products. The profitability of the synfuel IES is most sensitive to the value of the hydrogen PTC and the synfuel products as well as the cost of the carbon feedstock, highlighting the importance of governmental incentives regarding hydrogen, carbon emissions, and synfuel in driving the deployment of future nuclear synfuel IESs.

08 HYDROGEN↗

Rapidly Viable Sustained Grid

Rapid recovery of power flow, possibly after a blackout, is a crucial need arising in scenarios that are increasingly becoming more frequent; here, solutions for rapid viability of power while the grid is being restored are urgently needed to keep critical infrastructure (CI) online. Increasingly, after the initial recovery phase, sustenance of reliable power requires assistive services to the grid for long periods of time. Even though the need is urgent, there is only sparse effort present toward a comprehensive framework/strategy for making power rapidly viable with an emphasis on sustained grid ancillary services; which is the focus of this proposal. The proposed concept envisions four phases. In the first phase, when a large portion of power is disrupted (see Figure 1(a)), emphasis is on bringing CI online with the objective of maximizing the time horizon of power viability using resources available at the CI. In the second phase (Figure 1(b)), neighborhood resources are tightly coordinated that forms the CI’s central-core (CC) to provide guaranteed viability of CI over a longer horizon. In the third phase, self-organizing power networks are expanded in a distributed layer supporting the central-core (Figure 1(c)). In the fourth phase, separate CI-networks coalesce and are controlled in a coordinated fashion to provide grid ancillary services (AS), such as primary frequency control and enhancing grid resiliency. With time, system efficiencies and penetration of renewables increase, while the time-horizon of guaranteed sustenance of CI is maximized. Under proposed work, the concept will be instantiated with a focus on medical centers as CI. Comprehensive power hardware in the loop strategies and emulated field tests will guide and validate devised solutions. A strong T2M effort to commercialize resulting technology is outlined. The proposed technology will be transformative for the grid. It will fundamentally change the way large contingencies are managed where power systems and critical infrastructure transition from being fragile to being robust using intelligent, self-organizing control for coordinating resources, enhanced resiliency and use of sustainable energy sources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Discovery of False Data Injection Attacks on Power Grid Frequency Controllers with Reinforcement Learning [Poster]

While inverter-based DER (distributed energy resources) are instrumental to integrating renewable energy into the power grid, they reduce the grid's mechanical inertia, thereby increasing the risk of frequency instabilities. To compensate for frequency instability risks, the grid must also undergo a transformation to include digital technologies that allow for two-way communication between the utility and customers. The current and future state of the power grid allows for building a cleaner energy landscape. However, the grid may also become vulnerable to novel cyber threats. To preemptively protect the power grid against elaborate cyber-attacks, we propose to discover potential threats via reinforcement learning. In this work, the focus is on studying false data injection attacks that target the control logic of frequency controllers. We show that a reinforcement learning agent can successfully discover how to best inject false data into linear droop controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Communication-Constrained Robust Control and Learning of Grid-Connected

The electric grid of things (EGoT) promises great potential for innovative grid services by tapping into vast load flexibility. However, the unique characteristics of EGoT, being a part of the cyber-physical electric power system, present both opportunities and challenges, especially concerning supply-demand balancing, stability, and communication constraints. Traditionally, centralized control was employed to ensure balance and stability in power systems. However, with the massive influx of EGoT devices, new strategies are needed to efficiently coordinate and control these distributed devices for optimal grid operations. While some studies have explored efficiency and economic models, there remains a gap in ensuring reliability under everyday operations and resilience during extreme conditions. Addressing this gap, this project develops the technology for an Energy Service Interface (ESI) that includes novel pricing, control, learning, and distributed optimization algorithms, which will enable utilities to recruit EGoT assets for crucial grid services such as load flexibility, voltage regulation, and situation-awareness. The key novelty of the proposed technology is the careful distribution of learning and control functions across utility and EGoT asset owners such that provably efficient and resilient grid operations are attained while respecting communication and information-exchange constraints. Specifically, the project team develops machine-learning enhanced load modeling methods to allow EGoT asset owners to learn their load capability and flexibility, and develops pricing-based and decentralized learning-based control so that asset owners can coordinate to meet system-wide demand-supply balance and reliability goals. For extreme situations involving high-impact, low-probability catastrophic events (termed the “black-sky” events), the team also develops (1) a “Feeder-Operating Center-on-a-Laptop” (FOCAL) software that can assist utility personnel in leveraging EGoT assets to accelerate the service recovery of damaged feeders, and (2) distributed optimization algorithms that can coordinate the operation points of EGoT devices under severe communication constraints. The proposed technology has been extensively tested and evaluated through simulations and on a testbed. In summary, as we transition into a more interconnected and digital power grid era, our project’s findings and developments offer a pivotal step toward guaranteeing both efficiency and resilience in the face of both everyday operations and rare “black-sky” events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Decarbonized Electric Grid: Defining, Measuring, and Integrating Decarbonization into Electricity Sector Policy and Planning

Traditionally, electric grid planning seeks to maintain safe, reliable, efficient, and affordable service for current and future customers. As policies, expectations of the energy system, and the threat landscape evolve, additional objectives for power system planners are emerging, including decarbonization, resilience, and equity. Renewable and clean energy goals, especially in the context of deep decarbonization strategies, are changing the mix of resources on the electric grid and prompting new considerations for grid architecture. The increased frequency and severity of extreme weather events over the last two decades, coupled with cybersecurity concerns, have elevated resilience as a key system need. More recently, there has been greater focus on equity and energy justice in grid planning to ensure that disadvantaged communities are not adversely affected by grid modernization and have equal access to its benefits. In response, new thinking around multi-objective decision planning is exploring improvements in grid planning processes to better integrate approaches to meet decarbonization, resilience, and equity objectives. To provide a foundation for this work, a series of white papers was produced to summarize these emerging objectives.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resilient Electric Grid: Defining, Measuring, and Integrating Resilience into Electricity Sector Policy and Planning

Traditionally, electric grid planning seeks to maintain safe, reliable, efficient, and affordable service for current and future customers. As policies, expectations of the energy system, and the threat landscape evolve, additional objectives for power system planners are emerging, including decarbonization, resilience, and equity. Renewable and clean energy goals, especially in the context of deep decarbonization strategies, are changing the mix of resources on the electric grid and prompting new considerations for grid architecture. The increased frequency and severity of extreme weather events over the last two decades, coupled with cybersecurity concerns, have elevated resilience as a key system need. More recently, there has been greater focus on equity and energy justice in grid planning to ensure that disadvantaged communities are not adversely affected by grid modernization and have equal access to its benefits. In response, new thinking around multi-objective decision planning is exploring improvements in grid planning processes to better integrate approaches to meet decarbonization, resilience, and equity objectives. To provide a foundation for this work, a series of white papers was produced to summarize these emerging objectives.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Equitable Electric Grid: Defining, Measuring, and Integrating Equity into Electricity Sector Policy and Planning

Traditionally, electric grid planning seeks to maintain safe, reliable, efficient, and affordable service for current and future customers. As policies, expectations of the energy system, and the threat landscape evolve, additional objectives for power system planners are emerging, including decarbonization, resilience, and equity. Renewable and clean energy goals, especially in the context of deep decarbonization strategies, are changing the mix of resources on the electric grid and prompting new considerations for grid architecture. The increased frequency and severity of extreme weather events over the last two decades, coupled with cybersecurity concerns, have elevated resilience as a key system need. More recently, there has been greater focus on equity and energy justice in grid planning to ensure that disadvantaged communities are not adversely affected by grid modernization and have equal access to its benefits. In response, new thinking around multi-objective decision planning is exploring improvements in grid planning processes to better integrate approaches to meet decarbonization, resilience, and equity objectives. To provide a foundation for this work, a series of white papers was produced to summarize these emerging objectives.

24 POWER TRANSMISSION AND DISTRIBUTION↗

FY22 Grid Modernization & Energy Storage Program: Accomplishments & Impacts

Sandia’s Grid Modernization and Energy Storage program works to advance a national vision of a secure, resilient, and sustainable electric system for all users. Our achievements reflect a strategic approach combining technology development; modeling, simulation, and data analytics; and partnered demonstrations and outreach to further the adoption of advanced grid and storage technologies. Our FY22 efforts leverage the strengths of our partnerships—spanning Sandia’s core science and technology competencies as well as external technology leaders—to develop the solutions today which enable the grid of tomorrow. Much of the material in this report comes from the separate 2022 Accomplishments Report compiled by our Energy Storage subprogram team, a cornerstone of our grid research and achievements. The Grid Energy Storage Program at Sandia is focused on making energy storage cost-effective through research and development (R&D) in new battery technologies, advanced power electronics and power conversion systems, improved safety and reliability for energy storage systems, analytical tools for the valuation of energy storage, and the validation of new energy storage technologies through demonstration projects. During the 2022 fiscal year, Sandia executed R&D work supported by the U.S. Department of Energy’s (DOE) Office of Electricity – Energy Storage Program under the leadership of Dr. Imre Gyuk. This report indicates key areas of research and engagement and summarizes the impact of Sandia’s contributions through notable accomplishments, journal publications, patents, and technical conferences and presentations. It is provided with the hope that readers discover ways we can further team to create our modern grid and apply the outcomes of our efforts. The bulk of work described herein is funded by the DOE Office of Electricity and key programs within the DOE Office of Energy Efficiency and Renewable Energy. As we indicated in our report from last year, the contributors to our successes are too numerous to name here, though our team wishes to express our deep gratitude to the numerous program and project sponsors at the US Department of Energy, who often function equally as technical collaborators; our many partners in industry, academia, utilities, and other national labs; and fellow researchers and business partners at Sandia whose leadership and creativity have enabled the accomplishments described herein.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bias Correcting NOAA's High-Resolution Rapid Refresh (HRRR) Wind Resource Data for Grid Integration Applications [Slides]

Many weather years of high-quality wind data are widely accepted in the grid integration community to be important for studying wind energy technical potential, energy system operations, and grid resilience. NREL makes high-quality wind and solar resource data available. NREL's Grid-Atmosphere workshop (March 2024) identified NREL National Solar Radiation Database as widely used in grid integration modeling, but there is less agreement on commonly used wind datasets. One important factor identified by ESIG's 2023 report 'Weather Dataset Needs for Planning and Analyzing Modern Power Systems' for gold standard wind data is regular updates. To address the need for regular updates, NREL's team can now process all currently available and regularly updated High-Resolution Rapid Refresh (HRRR) outputs. HRRR is an hourly-updated operational forecast product produced by the National Oceanic and Atmospheric Administration (NOAA) (Dowell et al., 2022). One barrier to NREL using HRRR is systematic bias and consistency with NREL's existing wind datasets (e.g. WIND Toolkit, 'WTK') across weather years. To address this barrier, we show that the HRRR can be interpolated and bias-corrected to be consistent with NRE's existing datasets. We call the new dataset BC-HRRR (bias-corrected HRRR). As with historical datasets like the WTK, BC-HRRR is intended for use in grid integration modeling (e.g., capacity expansion, production cost, and resource adequacy modeling). BC-HRRR's (2015-present) consistency with WTK (2007-2013) allows NREL to extend internal grid integration tooling with 15+ weather years of wind data with low-overhead extensibility to future years as they are made available by NOAA. The rest of this slide deck documents the BC-HRRR processing methods, validation, and its implications for intended use.

17 WIND ENERGY↗

CFD-Informed Spacer Grid Models in CTF: Heat Transfer Enhancement and Form Pressure Losses

This report presents the current status of the pressure loss coefficient and heat transfer enhancement models derived for CTF from computational fluid dynamics (CFD) data. This is an effort to improve the modeling capabilities of CTF using results from a higher-fidelity code such as STAR-CCM+. The following four phenomena are the current scope of CFD-informed spacer grid models for CTF: (1) grid directed lateral cross-flow effects; (2) grid-induced turbulent-mixing effects; (3) grid-induced heat transfer enhancement downstream of the grid; and (4) the detailed pressure-loss effects caused by the spacer grid. This document covers phenomena (3) and (4) and how they are captured using CFD data. Please refer to CASL-U-2015-0020-000 for a discussion on phenomena (1) and (2).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Designing Yield Grids for Airborne Nuclear Explosions to Maintain Decrements in Rayleigh Waveform Amplitudes

This document details a method for selecting grid points that sample the yields of airborne, low yield nuclear explosions that constrains the relative size of seismic waveforms sourced by explosions that are parameterized by this grid. In detail, we impose this constraint so that the vertical component of ground displacement that is sourced by explosions with a fixed height of burst (HoB) at grid point k change by a fixed factor of a when compared to the waveform amplitudes sourced by explosions at grid point k + 1, as observed at a fixed standoff distance. This gridding thereby preserves amplitude ratios along the grid so that they are agnostic to k. We assert that this method is useful in tests that apply algorithms against synthetic or augmented datasets for which the performance of the algorithm must be measured against source size, and waveform amplitudes must change uniformly (e.g., Berg et al, 2025).

58 GEOSCIENCES↗

From Modular ADMS to Plug-and-Play Ops: Distribution Grid Operations with Platform-Level Orchestration to Enable Ambitious App Hosting

The core function of the distribution grid is to provide electricity to consumers affordably, reliably, and securely. In pursuing these core objectives, distribution utilities are accountable to customers, regulators, and in some cases, shareholders. Other third parties such as aggregators and microgrids can also have a stake in the smooth operation of the grid. Each of these stakeholders has economic, business, and/or governance objectives that inform their expectations of the distribution grid. This multi-objective, multi-stakeholder environment creates tension that must be reconciled to successfully design and operate the distribution grid. Innovative companies are competing to bring high-tech solutions to electric utilities and their customers that address each of these objectives. Many developers of advanced distribution management systems (ADMS) and distributed energy resource management systems (DERMS) have adopted a modular architecture that allows grid operators to select functions and features according to their individual system needs. A modular platform also allows the solution provider to develop and integrate specific new product modules; however, the need to pursue multiple objectives with a fixed set of controllable devices makes integration expensive whether it is done at the product development stage or the deployment stage. This cost creates a significant barrier to adoption and can lengthen the product to market time of new solutions. To fundamentally address the complexity of system integration for distribution grid operations, the U.S. Department of Energy Office of Electricity has funded the GridAPPS-D project at PNNL, which streamlines integration by contributing to standards development, defining system architecture, applying advanced mathematics, and developing open-source software to demonstrate the concept of an open data-integration platform for distribution operations. The open data-integration platform concept enables system operators and solution providers to deploy ambitious, best-of-breed applications (or apps) without continually reengineering for integration. Ambitious apps developed by different solution providers will inevitably attempt to achieve different control objectives with the same set of controllable devices. If the open platform itself can resolve these conflicts in a way that achieves the best available outcomes for all apps, doesn’t restrict the ambitious design of apps, and ensures safe and secure operations, apps will be able to plug-and-play with the platform at the same time as other ambitious apps. In this paper, we describe a framework called App Deconfliction that empowers a platform to assign setpoints to controllable devices based on the values preferred by different apps (and even external stakeholder entities like customers or aggregators). The App Deconfliction framework is compatible with several methods for determining setpoint values. We present two methods based on game theory that provide a subtle built-in incentive structure for developers to adapt their apps to the fact that they will be operating in a moderated multi-app environment and to favor device setpoints that have the most effect on their objectives over those that have the least effect. Our simulation-based demonstrations have shown that game-theory-based deconfliction can lead to a 7% improvement in control space utilization compared to design-based methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bias Corrected NOAA HRRR Wind Resource Data for Grid Integration Applications

To address the need for regularly updated wind resource data, NREL has processed the High-Resolution Rapid Refresh (HRRR) outputs for use in grid integration modeling. The HRRR is an hourly-updated operational forecast product produced by the National Oceanic and Atmospheric Administration (NOAA) (Dowell et al., 2022). Several barriers have prevented the HRRR's widespread proliferation in the wind energy industry: missing timesteps (prior to 2019), challenging file format for wind energy analysis, limited vertical height resolution, and negative bias versus legacy WIND Toolkit data (2007-2013). NREL has applied re-gridding, interpolation, and bias-correction to the native HRRR data to overcome these limitations. This results in the now-publicly-available bias corrected and interpolated HRRR (BC-HRRR) dataset for weather years 2015 to 2023. Bias correction is necessary for wind resource consistency across weather years to be used simultaneously in planning-focused grid integration studies alongside the original WIND Toolkit data. We show that quantile mapping with the WIND Toolkit as a historical baseline is an effective method for bias correcting the interpolated HRRR data: the BC-HRRR has reduced mean bias versus comparable gridded wind resource datasets (+0.12 m/s versus Vortex) and has very low mean bias versus ground measurement stations (+0.01 m/s) (Buster et al., 2024). BC-HRRR's consistency with the legacy WIND Toolkit allows NREL to extend grid integration analysis to 15+ weather years of wind data with low-overhead extensibility to future years as they are made available by NOAA. As with historical datasets like the WIND Toolkit, BC-HRRR is intended for use in grid integration modeling (e.g., capacity expansion, production cost, and resource adequacy modeling) both independently and alongside the legacy WIND Toolkit.

Array↗

An Updated Global Grid Point Surface Air Temperature Anomaly Data Set: 1851-1990 (revised 1991) (NDP-020)

This NDP presents land-based monthly surface-air-temperature anomalies (departures from a 1951-1970 reference period mean) on a 5° latitude by 10° longitude global grid. Monthly surface-air-temperature anomalies (departures from a 1957-1975 reference period mean) for the Antarctic (grid points from 65°S to 85°S) are presented in a similar way as a separate data set. The data were derived primarily from the World Weather Records and from the archives of the United Kingdom Meteorological Office. This long-term record of temperature anomalies may be used in studies addressing possible greenhouse-gas-induced climate changes. To date, the data have been employed in producing regional, hemispheric, and global time series for determining whether recent (i.e., post-1900) warming trends have taken place. The present updated version of this data set is identical to the earlier version for all records from 1851-1978 except for the addition of the Antarctic surface-air-temperature anomalies beginning in 1957. Beginning with the 1979 data, this package differs from the earlier version in several ways. Erroneous data for some sites have been corrected after a review of the actual station temperature data, and inconsistencies in the representation of missing values have been removed. For some grid locations, data have been added from stations that had not contributed to the original set. Data from satellites have also been used to correct station records where large discrepancies were evident. The present package also extends the record by adding monthly surface-air-temperature anomalies for the Northern (grid points from 85°N to 0°) and Southern (grid points from 5°S to 60°S) Hemispheres for 1985-1990. In addition, this updated package presents the monthly-mean-temperature records for the individual stations that were used to produce the set of gridded anomalies. The periods of record vary by station. Northern Hemisphere data have been corrected for inhomogeneities, while Southern Hemisphere data are presented in uncorrected form.For access to the data files, click this link to the CDIAC data transition website: http://cdiac.ess-dive.lbl.gov/ndps/ndp020.html