Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Flow loop”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

The Airspace Concepts Evaluation System Architecture and System Plant

The Airspace Concepts Evaluation System is a simulation of the National Airspace System. It includes models of flights, airports, airspaces, air traffic controls, traffic flow managements, and airline operation centers operating throughout the United States. It is used to predict system delays in response to future capacity and demand scenarios and perform benefits assessments of current and future airspace technologies and operational concepts. Facilitation of these studies requires that the simulation architecture supports plug and play of different air traffic control, traffic flow management, and airline operation center models and multi-fidelity modeling of flights, airports, and airspaces. The simulation is divided into two parts that are named, borrowing from classical control theory terminology, control and plant. The control consists of air traffic control, traffic flow management, and airline operation center models, and the plant consists of flight, airport, and airspace models. The plant can run open loop, in the absence of the control. However, undesired affects, such as conflicts and over congestions in the airspaces and airports, can occur. Different controls are applied, "plug and played", to the plant. A particular control is evaluated by analyzing how well it managed conflicts and congestions. Furthermore, the terminal area plants consist of models of airports and terminal airspaces. Each model consists of a set of nodes and links which are connected by the user to form a network. Nodes model runways, fixes, taxi intersections, gates, and/or other points of interest, and links model taxiways, departure paths, and arrival paths. Metering, flow distribution, and sequencing functions can be applied at nodes. Different fidelity model of how a flight transits are can be used by links. The fidelity of the model can be adjusted by the user by either changing the complexity of the node/link network-or the way that the link models how the flights transit from one node to the other.

Windhorst, Robert↗

The development of a cryogenic over-pressure pump

A cryogenic over-pressure pump (OPP) was tested in the prototype telescope liquid nitrogen (LN2) cooling system for the Dark Energy Survey (DES) Project. This OPP consists of a process cylinder (PC), gas generator, and solenoid operated valves (SOVs). It is a positive displacement pump that provided intermittent liquid nitrogen (LN2) flow to an array of charge couple devices (CCDs) for the prototype Dark Energy Camera (DECam). In theory, a heater submerged in liquid would generate the drive gas in a closed loop cooling system. The drive gas would be injected into the PC to displace that liquid volume. However, due to limitations of the prototype closed loop nitrogen system (CCD cooling system) for DECam, a quasiclosed-loop nitrogen system was created. During the test of the OPP, the CCD array was cooled to its designed set point temperature of 173K. It was maintained at that temperature via electrical heaters. The performance of the OPP was captured in pressure, temperature, and flow rate in the CCD LN2 cooling system at Fermi National Accelerator Laboratory (FNAL)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design Evaluation of a Next-Generation High-Temperature Particle Receiver for Concentrating Solar Thermal Applications

High-temperature particle receivers are being developed to achieve temperatures in excess of 700 °C for advanced power cycles and solar thermochemical processes. This paper describes designs and features of a falling particle receiver system that has been evaluated and tested at the National Solar Thermal Test Facility at Sandia National Laboratories. These advanced designs are intended to reduce heat losses and increase the thermal efficiency. Novel features include aperture covers, active air flow, particle flow obstructions, and optimized receiver shapes that minimize advective heat losses, increase particle curtain opacity and uniformity, and reduce cavity wall temperatures. Control systems are implemented in recent on-sun tests to maintain a desired particle outlet temperature using an automated closed-loop proportional–integral–derivative controller. These tests demonstrate the ability to achieve and maintain particle outlet temperatures approaching 800 °C with efficiencies between 60 and 90%, depending on incident power, mass flow, and environmental conditions. Lessons learned regarding the testing of design features and overall receiver operation are also presented.

Mills, Brantley H.↗

Experimental and computational investigations of ethane and ethylene kinetics with copper oxide particles for Chemical Looping Combustion

In this work, reaction pathways for the oxidation of methane, ethane, and ethylene with CuO was obtained by ReaxFF Molecular Dynamics (MD) simulations between temperatures of 1000 K and 2000 K. Experiments in a fixed-bed flow reactor were preformed with methane, ethane, and ethylene at temperatures ranging from 500 K to 1000 K with time-dependent species measurements from an Electron-Ionization Molecular Beam Mass Spectrometer (MBMS), and species validation with Gas Chromatography (GC) for detection of complete and intermediate combustion products. The MBMS and GC allow for the detection of oxygenated species and larger species produced from radical reformation. The simulation and experiment agree on the production of such species as CH 3 CHO, CH 2 O, CO, and H 2 O, which allow for the creation of simple C1 and C2 reaction pathways, which can be used in kinetic models of C2 species and larger fuels such as biofuels, which inherently depend on C1 and C2 kinetics and reaction pathway. The simulation and experiment disagree on the formation of C 2 H 2 , CH 3 OH, and CO 2 with large amounts of C 2 H 2 being measured in the ethylene oxidation simulations and CH 3 OH being formed in methane oxidation simulations, while neither species were experimentally found. In the case of CO 2 large amounts of CO 2 are rapidly produced in experiments with C2 fuels at 800 K, while little-to-no CO 2 was observed in simulations. This is believed to be resulting from the extremely short timescale of the simulations, preventing total oxidation of the fuel. Here, the differences in products produced between simulation and experiment allow for the potential to modify the ReaxFF potential functions to more accurately model the experimental products of Cu–H–O–C reaction kinetics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Update on Design of 10 MWe Iron-Based Coal Direct Chemical Looping Demonstration Plant

The Coal-Direct Chemical Looping (CDCL) process is emerging as a promising technology capable of high efficiency for producing electricity with low cost for carbon capture. In the CDCL process, coal is fully combusted to form carbon dioxide (CO2) and water via reaction with Fe2O3-based oxygen-carrier particles in a moving-bed reducer reactor. During reaction with coal, the Fe2O3 is reduced to form a mixture of Fe and FeO. The reduced particles are then transported to the combustor reactor where they are re-oxidized with air. The oxidation of the Fe and FeO mixture generates heat that can be used to produce steam for power generation. Once the particles are fully regenerated, they are pneumatically recycled to the reducer reactor where another reduction-oxidation (Redox) cycle begins. The Babcock & Wilcox Company (B&W) and The Ohio State University (OSU) have been developing the CDCL technology based on iron-based metal oxide particles circulating in a moving-bed reducer coupled with an entrained-flow combustor. As part of a Phase I effort of a DOE-sponsored project, B&W identified scale-up technology gaps for the coal-direct chemical looping reactor process, most of which fall under the moving-bed reactor design and operation. However, after the Phase I research, B&W concluded that the CDCL technology has the potential of generating electricity while meeting the DOE goals of greater than 90% CO2 capture and less than 35% increase in levelized cost of electricity (LCOE). B&W then moved to a Phase II project to design, build and demonstrate the CDCL technology at a 250 kWth capacity. B&W finished the construction and commissioning of the pilot test facility in 2017. The approach used to design a 250 kWth pilot-scale CDCL facility to investigate the technology gaps is presented. Important lessons from the commissioning activities that would transfer to commercial plant start-up are also shared. The findings from the test program are being incorporated into a Pre-FEED study for a 10 MWe large pilot demonstration. Under a separately-funded heat integration project, B&W and OSU are developing a multiphase computational fluid dynamic model (MFIX) of the combustor to quantify heat transfer to embedded steam generation surface, utilizing pinch analysis (ASPEN Energy Analyzer) to identify potential improvements of the heat integration scheme, and developing an integrated dynamic model (ProTRAX) of the steam turbine coupled with the chemical looping process to identify potential start-up and transient operation issues. Under an advanced control system for optimizing operation, B&W is supporting OSU to install a rules-based optimizer (B&W’s FocalPoint) on their 25 kWt bench-scale facility on the OSU West Campus. Finally, B&W and OSU were recently selected to perform a Phase I Feasibility study to evaluate installation of the 10 MWe pilot at the Dover Power & Light Municipal Power Plant in Dover, Ohio. The feasibility study includes compiling an Environmental Information Volume and generating a cost estimate for the design, construction and commissioning of the plant as well as lining up commitments from potential project participants and funding contributors. Updates on each project will be presented. The status of the technology development will be discussed. We focus on the progress made to date towards closing the technology gaps under each project.

20 FOSSIL-FUELED POWER PLANTS↗

A RELAP5-3D Model of the Lobo Lead Loop

The goal of our research is to build upon the capability of RELAP5-3D to model molten lead systems. Molten lead has several potential uses in future advanced reactors like the lead fast reactor or fusion reactors that utilize dual-coolant lead lithium blankets. This potential for use in future generations of reactors highlights the necessity to develop molten lead models to ensure that they can accurately predict the thermohydraulic behavior. We have developed a RELAP5-3D model of the Lobo Lead Loop facility, located at the University of New Mexico, to verify the accuracy of RELAP5-3D via comparison to existing computational fluid dynamics results and analytical calculations. It was found that RELAP5-3D accurately calculated radiative heat transfer (within < 1%) when compared to theoretical calculations. In addition, pressure drop calculations done in RELAP5-3D demonstrated reasonable agreement within 20 kPa, mostly within ~7-15%, when compared to the computational fluid dynamics model of the facility developed by the University of New Mexico, and captured the dependence of pressure drop on flow velocity accurately. Finally, a hypothetical loss of flow transient was imposed on the RELAP5-3D model to determine the feasibility of performing a similar experiment with the Lobo Lead Loop. It was found that such an experiment could be possible as the RELAP5-3D model indicated that the temperatures of the fluid would not exceed limiting temperatures of the structure (1658 K) nor the maximum temperature of the electromagnetic pump inlet (823 K). Although there is not experimental data to begin validation, the model will be readily available for future validation studies when the experimental data is generated, especially as the model continues to evolve over time. Furthermore, the results so far demonstrate a promising first step in the verification/validation of the RELAP5-3D model of the Lobo Lead Loop.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fixed bed reduction of hematite under alternating reduction and oxidation cycles

The rate of the reduction reaction of a low cost natural hematite oxygen carrier for chemical looping combustion was investigated in a fixed bed reactor where hematite samples of about 1 kg were exposed to a flowing stream of methane and argon. The investigation aims to develop understanding of the factors that govern the rate of reduction with in larger reactors as compared to mostly TGA investigations in the literature. Comparison of the experimental data with a model indicated that reaction between the methane and the iron oxide shows multi-step reactions. The analysis also shows that the conversion occurs with a process that likely consumes all the oxygen close to the surface of the hematite particles and another process that is likely controlled by the diffusion of oxygen to the surface of the particles. Additional analysis shows that the thickness of the fast layer is on the order of 8 unit crystals. As a result, this is about 0.4% of the hematite; however, it comprises about 20 to 25% of the conversion for the 10 min reduction cycle.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Energy saving potential of a two-pipe system for simultaneous heating and cooling of office buildings

This paper analyzes the performance of a novel two-pipe system that operates one water loop to simultaneously provide space heating and cooling with a water supply temperature of around 22 °C. To analyze the energy performance of the system, a simulation-based research was conducted. The two-pipe system was modelled using the equation-based Modelica modeling language in Dymola. A typical office building model was considered as the case study. Simulations were run for two construction sets of the building envelope and two conditions related to inter-zone air flows. To calculate energy savings, a conventional four-pipe system was modelled and used for comparison. The conventional system presented two separated water loops for heating and cooling with supply temperatures of 45 °C and 14 °C, respectively. Simulation results showed that the two-pipe system was able to use less energy than the four-pipe system thanks to three effects: useful heat transfer from warm to cold zones, higher free cooling potential and higher efficiency of the heat pump. In particular, the two-pipe system used approximately between 12% and 18% less total annual primary energy than the four-pipe system, depending on the simulation case considered.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Three-dimensional vortical structures of transition in plane channel flow

Three-dimensional visualization of flwo field structures in transitional plane channel flow obtained from a numerical simulation are presented at two Reynolds numbers. It is revealed that at the one-spike stage, independent of Reynolds number, the flow is characterized by a multi-layer vortex system. In the upper layer, total vorticity vector plots indicate a high-shear layer dominated by spanwise vorticity, whereas the middle layer (corresponding approximately to the critical layer) forms a vortex loop (alpha-vortex) consisting of strong streamwise and spanwise vorticity components. At the three-spike stage, the breakdown of the vortical structure proceeds in a manner similar to frontal relaminarization of turbulent spots. This process is accompanied by intense vortex lift-up activity near the wall which seems to originate at the legs of the vortex loop trailing the high-shear layer. Finally, at the five-spike stage, it is shown that high-vorticity regions (vortical structures) develop into horseshow eddies in planes inclined to the main flow direction.

Biringen, S.↗

Optimum design of ninety degree bends

An algorithm for the optimum design of an internal flow component to obtain the maximum pressure rise is presented. Maximum pressure rise in a duct with simultaneous turning and diffusion is shown to be related to the control of flow separation on the passage walls. Such a flow is usually associated with downstream conditions that are desirable in turbomachinery and propulsion applications to ensure low loss and stable performance. The algorithm requires the solution of an 'adjoint' problem in addition to the 'direct' equations governing the flow in a body, which in the present analysis are assumed to be the laminar Navier-Stokes equations. The theoretical framework and computational algorithms presented in this study are for the steady Navier-Stokes equations. A procedure is developed for the numerical solution of the adjoint equations. This procedure is coupled with a direct solver in a design iteration loop, that provides a new shape with a higher pressure rise. This procedure is first validated for the design of optimum plane diffusers in two-dimensional flow. The direct Navier-Stokes and the 'adjoint' equations are solved using a finite volume formulation for spatial discretization in an artificial compressibility framework. A simplified version of the above approach is then utilized to design ninety degree diffusing bends. Calculations were carried out for a mean radius ratio at inlet of 2.5 and Reynolds numbers varying from 100 to 500. While at this stage laminar flows is assumed, it is shown that a similar approach can be conceived for turbulent flows.

Modi, Vijay↗

Coal Direct Chemical Looping Retrofit to Pulverized Coal Power Plants for In-Situ CO2 Capture

A novel Coal Direct Chemical Looping (CDCL) system is proposed to effectively capture CO2 from existing PC power plants. The work during the past three years has led to an oxygen carrier particle with satisfactory performance. Moreover, successful laboratory, bench scale, and integrated demonstrations have been performed. The proposed project further advanced the novel CDCL technology to sub-pilot scale (25 kWth). To be more specific, the following objectives attained in the proposed project are: 1. to further improve the oxygen carrying capacity as well as the sulfur/ash tolerance of the current (working) particle; 2. to demonstrate continuous CDCL operations in an integrated mode with > 99% coal (bituminous, subbituminous, and lignite) conversion as well as the production of high temperature exhaust gas stream that is suitable for steam generation in existing PC boilers; 3. to identify, via demonstrations, the fate of sulfur and NOx; 4. to conduct thorough techno-economic analysis that validates the technical and economical attractiveness of the CDCL system. The objectives outlined above were achieved through collaborative efforts among all the participants. CONSOL Energy Inc. performed the techno-economic analysis of the CDCL process. Shell/CRI was able to perform feasibility and economic studies on the large scale particle synthesis and provide composite particles for the sub-pilot scale testing. The experience of B&W (with boilers) and Air Products (with handling gases) assisted the retrofit system design as well as the demonstration unit operations. The experience gained from the sub-pilot scale demonstration of the Syngas Chemical Looping (SCL) process at OSU was able to ensure the successful handling of the solids. Phase 1 focused on studies to improve the current particle to better suit the CDCL operations. The optimum operating conditions for the reducer reactor such as the temperature, char gasification enhancer type, and flow rate were identified. The modifications of the existing bench scale reactor were completed in order to use it in the next phase of the project. In Phase II, the optimum looping medium was selected, and bench scale demonstrations were completed using them. Different types of coal char such as those obtained from bituminous, subbituminous, and lignite were tested. Modifications were made on the existing sub-pilot scale unit for coal injection. Phase III focused on integrated CDCL demonstration in the sub-pilot scale unit. A comprehensive ASPEN® simulations and economic analysis was completed by CONSOL t is expected that the CDCL process will be ready for further demonstrations in a scale up unit upon completion of the proposed project.

Zeng, Liang↗

Full Aerothermal Characterization of the NASA Glenn Research Center 9- by 15-Foot Low-Speed Wind Tunnel (2019 Test)

Following completion of the 9- by 15-Foot Low Speed Wind Tunnel acoustic improvement modification project, a characterization of the flow field throughout the 9- by 15-foot test section was conducted in 2019. The acoustic improvement modifications project included several large-scale tunnel loop modifications and reconstruction of the 9- by 15-Foot Low Speed Wind Tunnel test section and diffuser to decrease the noise floor in the test section. Data were collected at three cross-sectional planes in the 9- by 15-ft test section using a 15-foot traversing calibration rake and a set of eight boundary layer rakes. The data from the characterization test were used to generate calibration relationships for facility operation and understand the flow quality in the new test section, including uniformity, flow angularity, turbulence intensity, and boundary layer characteristics. Additionally, the subsonic quick check rake was used to baseline the check calibration data set for the new test section.

Wind↗

Test Section Characterization of the 9- by 15-Foot Low Speed Wind Tunnel

Following completion of the 9- by 15-Foot Low Speed Wind Tunnel acoustic improvement modification project, a characterization of the flow field throughout the 9- by 15-foot test section was conducted in 2019. The acoustic improvement modifications project included several large-scale tunnel loop modifications and reconstruction of the 9- by 15-Foot Low Speed Wind Tunnel test section and diffuser to decrease the noise floor in the test section. Data were collected at three cross-sectional planes in the 9- by 15-ft test section using a 15-foot traversing calibration rake and a set of eight boundary layer rakes. The data from the characterization test were used to generate calibration relationships for facility operation and understand the flow quality in the new test section, including uniformity, flow angularity, turbulence intensity, and boundary layer characteristics. Additionally, the subsonic quick check rake was used to baseline the check calibration data set for the new test section.

Calibration↗

Experience with Chemical Looping Combustion of Coal in a 200 kW Dual Fluidized Bed Reactor

The University of Utah recently commissioned a dual fluidized bed process development unit (PDU) for investigating chemical looping combustion (CLC) and chemical looping with oxygen uncoupling (CLOU) of coal. The reactors and supporting systems were sized to support at least 200 kW of coal input based on available reaction rate data. Both the air reactor and fuel reactor are circulating fluidized beds and bed material passes between the reactors via loop seals. The reactors are refractory-lined rather than electrically heated, so the system must be preheated with natural gas before chemical looping combustion can begin. Air and steam are preheated through a combination of electric heating and natural gas burners and reactor product gas flows through heat exchangers and bag houses to cool and clean the gas of particulate. As is typical with pilot-scale systems, several operational challenges were encountered as the system was brought online and operation progressed from heatup and initial testing with gaseous fuels towards full CLOU processing of coal. The system hardware and operational procedures have undergone several modifications, but the PDU can now reliably be preheated to the operating temperature and coal can be fed at the target feed rate. This paper presents the PDU, describes the procedures for evaluating carbon conversion, CO2 capture and CO2 purity, and presents initial results from chemical looping combustion of coal with non-CLOU and CLOU carriers. General experience of operating the plant and notable challenges and solutions are also presented.

Whitty, Kevin J.↗

FLOCCULENT FLOWS IN THE CHROMOSPHERIC CANOPY OF A SUNSPOT

High-quality imaging spectroscopy in the H{alpha} line, obtained with the CRisp Imaging SpectroPolarimeter (CRISP) at the Swedish 1-m solar Telescope (SST) at La Palma and covering a small sunspot and its surroundings, is studied. They exhibit ubiquitous flows both along fibrils making up the chromospheric canopy away from the spot and in the superpenumbra. We term these flows 'flocculent' to describe their intermittent character, that is, morphologically reminiscent of coronal rain. The flocculent flows are investigated further in order to determine their dynamic and morphological properties. For the measurement of their characteristic velocities, accelerations, and sizes, we employ a new versatile analysis tool, the CRisp SPectral EXplorer (CRISPEX), which we describe in detail. Absolute velocities on the order of 7.2-82.4 km s{sup -1} are found, with an average value of 36.5 {+-} 5.9 km s{sup -1} and slightly higher typical velocities for features moving toward the sunspot than away. These velocities are much higher than those determined from the shift of the line core, which shows patches around the sunspot with velocity enhancements of up to 10-15 km s{sup -1} (both red- and blueshifted). Accelerations are determined for a subsample of features that show clear accelerating or decelerating behavior, yielding an average of 270 {+-} 63 m s{sup -2} and 149 {+-} 63 m s{sup -2} for the accelerating and decelerating features, respectively. Typical flocculent features measure 627 {+-} 44 km in length and 304 {+-} 30 km in width. On average, 68 features are detected per minute, with an average lifetime of 67.7 {+-} 8.8 s. The dynamics and phenomenology of the flocculent flows suggest they may be driven by a siphon flow, where the flocculence could arise from a density perturbation close to one of the footpoints or along the loop structure.

79 ASTRONOMY AND ASTROPHYSICS↗

POST-CORONAL MASS EJECTION PLASMA OBSERVED BY HINODE

In the present work we study the evolution of an active region after the eruption of a coronal mass ejection (CME) using observations from the EIS and XRT instruments on board Hinode. The field of view includes a post-eruption arcade, a current sheet, and a coronal dimming. The goal of this paper is to provide a comprehensive set of measurements for all these aspects of the CME phenomenon made on the same CME event. The main physical properties of the plasma along the line of sight-electron density, thermal structure, plasma composition, size, and, when possible, mass-are measured and monitored with time for the first three hours following the CME event of 2008 April 9. We find that the loop arcade observed by EIS and XRT may not be related to the post-eruption arcade. Post-CME plasma is hotter than the surrounding corona, but its temperature never exceeds 3 MK. Both the electron density and thermal structure do not show significant evolution with time, while we found that the size of the loop arcade in the Hinode plane of the sky decreased with time. The plasma composition is the same in the current sheet, in the loop arcade, and in the ambient plasma, so all these plasmas are likely of coronal origin. No significant plasma flows were detected.

79 ASTRONOMY AND ASTROPHYSICS↗

Syracuse Univesity Test Report On Uptake Factor Resulting From A Dropped Storage Container - Phase II

Under certain circumstances, powder from an accidently dropped container can become airborne and inhaled by people nearby such as those who are moving the containers. The inhaled fine particles can deposit on respiratory tracts and lungs, causing asthma, lung cancer, and other acute respiratory illnesses and chronic symptoms. The objective of this study was to develop a standard procedure to measure the airborne concentrations of different size particles within the vicinity of a dropped container where a significant portion of the contained powder is ejected. Tungsten oxide (WO 3 ) was selected in this study to represent relatively heavy powders (7.16 g/cm 3 specific gravity for WO 3 ). A typical can with the outer dimensions of 4.25” diameter and 4.875” tall was used as the container. The powder was dropped in two different configurations: 1) contained within a can covered by a lid that has a 0.25” diameter hole, and 2) contained within a can without a lid. The packing volume of the powder was 51.4 in 3 (842.7 cm 3 ) and the target mass was 1936 g. The tests were carried out in a full-scale stainless steel environmental chamber with an interior volume of 852 ft 3 (24.1 m3). The chamber system includes an internal recirculation loop with a rectangular air diffuser and 10 variable frequency drive fans to provide a typical room air recirculation flow pattern. Two air filters were installed in the chamber air supply duct and return duct to achieve the required low background particle concentration. The initial chamber air conditions were set at 70°F (± 5°F) and 50% (± 10%) RH. A supporting frame and releasing device were designed and built to trigger consistently the dropping of the can. The particle sampling inlet was placed 5 ft above the floor and 6 inches laterally away from the can’s falling path. Concentrations of particles between 0.5 μm and 20 μm were recorded in units of mass and number of particles per unit volume. The data acquisition rate was once every 2 seconds during the first 2 hours. A test procedure was developed and verified. A total of thirty two drop tests were performed, eight in Phase I and twenty four in Phase II, covering variations in dropping height (8 ft or 4 ft from the floor), room air movement (0.25-0.30 m/s or 0.10-0.15 m/s near the ceiling), landing scenario (on a flat plate or a block), and lid condition (¼” lid hole or no lid). There were ten tests with flat plate and ¼” lid hole, ten tests with flat plate no lid and twelve tests with block no lid.

42 ENGINEERING↗

A Graph Theory Method for Identification of a Minimum Breakpoint Set for Directional Relay Coordination

The energy grid becomes more complex with increasing penetration of renewable resources, distributed energy storage, distributed generators, and more diverse loads such as electric vehicle charging stations. The presence of distributed energy resources (DERs) requires directional protection due to the added potential for energy to flow in both directions down the line. Additionally, contingency requirements for critical loads within a microgrid may result in looped or meshed systems. Computation speeds of iterative methods required to coordinate loops are improved by starting with a minimum breakpoint set (MBPS) of relays. A breakpoint set (BPS) is a set of breakers such that, when opened, breaks all loops in a mesh grid creating a radial system. A MBPS is a BPS that consists of the minimum possible number of relays required to accomplish this goal. In this paper, a method is proposed in which a minimum spanning tree is computed to indirectly break all loops in the system, and a set difference is used to identify the MBPS. The proposed method is found to minimize the cardinality of the BPS to achieve a MBPS.

24 POWER TRANSMISSION AND DISTRIBUTION↗