Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FRED”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Experiments and Computational Theory for Electrical Breakdown in Critical Components: THz Imaging of Electronic Plasmas.

This report describes the development of ultra-short pulse laser (USPL) induced terahertz (THz) radiation to image electronic plasmas during electrical breakdown. The technique uses three pulses from two USPLs to (1) trigger the breakdown, (2) create a 2 picosecond (ps, 10 -12 s), THz pulse to illuminate the breakdown, and (3) record the THz image of the breakdown. During this three year internal research program, sub-picosecond jitter timing for the lasers, THz generation, high bandwidth (BW) diagnostics, and THz image acquisition was demonstrated. High intensity THz radiation was optically-induced in a pulse-charged gallium arsenide photoconductive switch. The radiation was collected, transported, concentrated, and co-propagated through an electro-optic crystal with an 800 nm USPL pulse whose polarization was rotated due to the spatially varying electric field of the THz image. The polarization modulated USPL pulse was then passed through a polarizer and the resulting spatially varying intensity was detected in a high resolution digital camera. Single shot images had a signal to noise of %7E3:1. Signal to noise was improved to %7E30:1 with several experimental techniques and by averaging the THz images from %7E4000 laser pulses internally and externally with the camera and the acquisition system (40 pulses per readout). THz shadows of metallic films and objects were also recorded with this system to demonstrate free-carrier absorption of the THz radiation and improve image contrast and resolution. These 2 ps THz pulses were created and resolved with 100 femtosecond (fs, 10 -15 s) long USPL pulses. Thus this technology has the capability to time-resolve extremely fast repetitive or single shot phenomena, such as those that occur during the initiation of electrical breakdown. The goal of imaging electrical breakdown was not reached during this three year project. However, plans to achieve this goal as part of a follow-on project are described in this document. Further modifications to improve the THz image contrast and resolution are proposed, and after they are made, images of photo-induced carriers in gallium arsenide and silicon will be acquired to evaluate image sensitivity versus carrier density. Finally electrical breakdown will be induced with the first USPL pulse, illuminated with THz radiation produced with the second USPL pulse and recorded with the third USPL pulse.

36 MATERIALS SCIENCE↗

Data Validation Package April 2016 Groundwater and Surface Water Sampling at the Monticello, Utah, Disposal and Processing Sites August 2016

This semiannual event includes sampling groundwater and surface water at the Monticello Disposal and Processing Sites. Sampling and analyses were conducted as specified in the Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated) and Program Directive MNT-2016-01. Complete sample sets were collected from 42 of 48 planned locations (9 of 9 former mill site wells, 13 of 13 downgradient wells, 7 of 9 downgradient permeable reactive barrier wells, 4 of 7 seeps and wetlands, and 9 of 10 surface water locations). Planned monitoring locations are shown in Attachment 1, Sampling and Analysis Work Order. Locations R6-M3, SW00-01, Seep 1, Seep 2, and Seep 5 were not sampled due to insufficient water availability. A partial sample was collected at location R4-M3 due to insufficient water. All samples from the permeable reactive barrier wells were filtered as specified in the program directive. Duplicate samples were collected from surface water location Sorenson and from monitoring wells 92-07 and RlO-Ml. Water levels were measured at all sampled wells and an additional set of wells. See Attachment2, Trip Report for additional details. The contaminants of concern (COCs) for the Monticello sites are arsenic, manganese, molybdenum, nitrate+ nitrite as nitrogen (nitrate+ nitrite as N), selenium, uranium, and vanadium. Locations with COCs that exceeded remediation goals are listed in Table 1 and Table 2. Time-concentration graphs of the COCs for all groundwater and surface water locations are included in Attachment 3, Data Presentation. An assessment of anomalous data is included in Attachment 4.

54 ENVIRONMENTAL SCIENCES↗

A Novel Hybrid Reformer-Electrolyzer-Purifier (REP) for Distributed Production of Low-Cost, Low Greenhouse Gas Hydrogen

FuelCell Energy with support from the Department of Energy’s Office of Energy Efficiency and Renewable Energy (EERE) has investigated the production of low-cost, low CO2 hydrogen using a molten carbonate fuel cell operating as an electrolyzer. We confirmed the feasibility of the technology by testing a large-scale short stack. Economic analysis was done with the assistance of the National Fuel Cell Center at the University of California, Irvine and we found the technology to be attractive, especially for distributed hydrogen. We explored the performance under various operating parameters and developed an accurate model for further analysis and development calculations. We achieved the expected results, meeting all program goals. We identified additional uses of the technology such as for CO2 capture, power storage, and power load leveling.

08 HYDROGEN↗

Monticello Mill Tailings Site, Operable Unit lll, Annual Groundwater Report, May 2015 Through April 2016

This report provides the annual analysis of water quality restoration progress, cumulative through April 2016, for Operable Unit (OU) III, surface water and groundwater, of the U.S. Department of Energy (DOE) Office of Legacy Management (LM) Monticello Mill Tailings Site (MMTS). The MMTS is a Comprehensive Environmental Response, Compensation, and Liability Act National Priorities List site located in and near the city of Monticello, San Juan County, Utah. MMTS comprises the 110-acre site of a former uranium- and vanadium-ore-processing mill (mill site) and 1700 acres of surrounding private and municipal property. Milling operations generated 2.5 million cubic yards of waste (tailings) from 1942 to 1960. The tailings were impounded at four locations on the mill site. Inorganic constituents in the tailings drained from the impoundments to contaminate local surface water (Montezuma Creek) and groundwater in the underlying alluvial aquifer. Mill tailings dispersed by wind and water also contaminated properties surrounding and downstream of the mill site. Remedial actions to remove and isolate radiologically contaminated soil, sediment, and debris from the former mill site, Operable Unit I (OU I), and surrounding properties (OU II) were completed in 1999 with the encapsulation of the wastes in an engineered repository located on DOE property 1 mile south of the former mill site. This effectively removed the primary source of groundwater contamination; however, contamination of groundwater and surface water remains within OU III at levels that exceed water quality protection standards. Uranium is the primary contaminant of concern (COC). LM implemented monitored natural attenuation with institutional controls as the OU III remedy in 2004. Because groundwater restoration proceeded more slowly than expected and did not meet performance criteria established in the OU III Record of Decision (June 2004), LM implemented a contingency action in 2009 by an Explanation of Significant Difference to include a pump-and­ treat system using a single extraction well and treatment by zero-valent iron (ex situ treatment system). The contingency action was optimized in 2015 with the installation of8 extraction wells and 16 monitoring wells in a focused area of the aquifer, the area of attainment (AOA). Contaminated water is treated by solar evaporation at an existing facility at the LM repository.

54 ENVIRONMENTAL SCIENCES↗

Data Validation Package October 2016 Groundwater and Surface Water Sampling at the Monticello, Utah, Disposal and Processing Sites January 2017

Sampling Period: October 10–12, 2016. This semiannual event includes sampling groundwater and surface water at the Monticello Disposal and Processing Sites. Sampling and analyses were conducted as specified in the Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated) and Program Directive MNT-2016-01. Samples were collected from 54 of 64 planned locations (16 of 17 former mill site wells, 15 of 18 downgradient wells, 7 of 9 downgradient permeable reactive barrier wells, 3 of 3 bedrock wells, 4 of 7 seeps and wetlands, and 9 of 10 surface water locations).

54 ENVIRONMENTAL SCIENCES↗

Monticello Mill Tailings Site Operable Unit III Annual Groundwater Report May 2014 Through April 2015, October 2015

This report provides the annual analysis of water quality restoration progress, cumulative through April 2015, for Operable Unit (OU) III, surface water and groundwater, of the U.S. Department of Energy (DOE) Office of Legacy Management Monticello Mill Tailings Site (MMTS). The MMTS is a Comprehensive Environmental Response, Compensation, and Liability Act National Priorities List site located in and near the city of Monticello, San Juan County, Utah. MMTS comprises the 110-acre site of a former uranium- and vanadium-ore-processing mill (mill site) and 1,700 acres of surrounding private and municipal property. Milling operations generated 2.5 million cubic yards of waste (tailings) from 1942 to 1960. The tailings were impounded at four locations on the mill site. Inorganic constituents in the tailings drained from the impoundments to contaminate local surface water (Montezuma Creek) and groundwater in the underlying alluvial aquifer. Mill tailings dispersed by wind and water also contaminated properties surrounding and downstream of the mill site. Remedial actions to remove and isolate radiologically contaminated soil, sediment, and debris from the former mill site (OU I) and surrounding properties (OU II) were completed in 1999 with the encapsulation of the wastes in an engineered repository located on DOE property 1 mile south of the former mill site. Contamination of groundwater and surface water remains within OU III at levels that exceed water quality protection standards. Uranium is the primary contaminant of concern. LM implemented monitored natural attenuation with institutional controls as the OU III remedy in 2004. Because groundwater restoration proceeded more slowly than expected and did not meet performance criteria established in the OU III Record of Decision (June 2004), LM implemented a contingency action in 2009 by an Explanation of Significant Difference to include a pump-and-treat system using a single extraction well and treatment by zero-valent iron (ex-situ treatment system). The contingency action was optimized in 2015 with the installation of 8 extraction wells and 16 monitoring wells in a focused area of the aquifer (area of attainment). Contaminated water is treated by solar evaporation at an existing onsite LM facility. Environmental monitoring at OU III consists of twice-yearly (April and October) collection and analysis of hydrologic and water-quality data from an established network of observation wells, seeps, and surface water locations. The scope of monitoring was expanded in 2009 for the ex situ treatment system and in 2015 for the remedy optimization system. Operation and monitoring of the ex situ treatment system was discontinued in 2014 with the start-up of the remedy optimization system. No data anomalies for OU III water quality trending or restoration progress are identified for the May 2014 through April 2015 reporting period. Although some regions of the aquifer demonstrate decreasing concentration trends, such trending is not evident for the bulk of the aquifer and a prolonged restoration period is indicated. The groundwater contingency remedy optimization system captures significant contaminant mass (primarily uranium) from the area of attainment; however, because that system only became operational in 2015, a long-term forecast of restoration progress is premature.

54 ENVIRONMENTAL SCIENCES↗

Data Validation Package October 2015 Groundwater and Surface Water Sampling at the Monticello, Utah, Processing Site January 2016

Sampling Period: October 12–14, 2015. This semiannual event includes sampling groundwater and surface water at the Monticello Mill Tailings Site. Sampling and analyses were conducted as specified in the 2004 Monticello Mill Tailings Site Operable Unit III Post-Record of Decision Monitoring Plan, Draft Final and Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated). Samples were collected from 52 of 61 planned locations (15 of 17 former mill site wells, 17 of 18 downgradient wells, 9 of 9 downgradient permeable reactive barrier wells, 2 of 7 seeps and wetlands, and 9 of 10 surface water locations). Locations MW00-07, Seep 1, Seep 2, Seep 3, Seep 5, Seep 6, SW00-01, T01-13, and T01-19 were not sampled because of insufficient water availability. All samples were filtered as specified in the monitoring plan. Duplicate samples were collected from surface water location W3-04 and from monitoring wells 82-08, 92-09, and 92-10. Water levels were measured at all but one sampled well and an additional set of wells. The contaminants of concern (COCs) for the Monticello Mill Tailings Site are arsenic, manganese, molybdenum, nitrate + nitrite as nitrogen (nitrate + nitrite as N), selenium, uranium, and vanadium. Time-concentration graphs of the COCs for all groundwater and surface water locations are included in this report. Locations with COCs that exceeded remediation goals are listed.

2015 Monticello↗

Safety Testing of AGR-2 UCO Compacts 6-4-2 and 2-3-1

Post-irradiation examination (PIE) and elevated-temperature safety testing are being performed on tristructural-isotropic (TRISO) coated-particle fuel compacts from the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program second irradiation experiment (AGR-2). Details on this irradiation experiment have been previously reported [Collin 2014]. The AGR-2 PIE effort builds upon the understanding acquired throughout the AGR-1 PIE campaign [Demkowicz et al. 2015] and is establishing a database for the different AGR-2 fuel designs.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fundamental Processes in Plasmas

This Final Technical Report gives brief summaries of the plasma physics results developed under DOE grant DE-SC0002451; and provides reference to the published journal articles giving full scientific descriptions. General topics include 1) cyclotron modes; 2) damping and decay of Langmuir modes; 3) 2D vortex dynamics and diocotron modes; 4) separatrix-induced transport and damping; and 5) long-range collisional velocity slowing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Californium-252 Program Equipment Evaluation

To successfully continue the 252 Cf production and meet the needs of the customers, a comprehensive evaluation of the Building 7920 processing equipment was requested to identify equipment critical to the operational continuity of the program.

47 OTHER INSTRUMENTATION↗

Confirmatory LBL Analysis of AGR-5/6/7 Compacts and Over-Coated Particles BWXT Batches 11034, 14154C, 14156C, AND 14156D

Fuel for the Advanced Gas Reactor Fuel Development and Qualification (AGR) Program’s AGR-5/6/7 irradiation test in the Idaho National Laboratory (INL) Advanced Test Reactor (ATR) was produced by BWX Technologies (BWXT) Nuclear Operations Group in Lynchburg, Virginia. Tristructural isotropic (TRISO) coatings were deposited using a 150-mm-diameter production-scale fluidized-bed chemical vapor deposition (CVD) furnace on 425-μm-nominal-diameter spherical kernels from Lot J52R-16-69317 containing a mixture of 15.5% 235U low-enriched uranium carbide and uranium oxide (UCO). The TRISO coatings consisted of four consecutive CVD layers: a ~50% dense carbon buffer layer with 100-μmnominal thickness, a dense inner pyrolytic carbon (IPyC) layer with 40-μm-nominal thickness, a silicon carbide (SiC) layer with 35-μm-nominal thickness, and a dense outer pyrolytic carbon (OPyC) layer with 40-μm-nominal thickness. TRISO-coated particle Lot J52R-16-98005 was over-coated with a graphite/resin blend and these over-coated particles were pressed in half-inch-diameter, one-inch-long cylindrical compacts. Two packing fractions (PF) were produced, 40%PF and 25%PF, where the TRISO particle volume made up approximately 40% and 25% of the total compact volume, respectively. The AGR-5/6/7 Fuel Specification, SPC-1352 [Marshall 2016], provides the requirements necessary for acceptance of the fuel manufactured for the AGR-5/6/7 irradiation test. Quality control (QC) acceptance testing for all AGR-5/6/7 composited lots and single batches was performed by BWXT, with the exception of pyrolytic carbon (PyC) anisotropy and defective IPyC fraction in the TRISO candidate batches and final composite, which were measured at the Oak Ridge National Laboratory (ORNL) and reported in ORNL/TM-2017/036 [Hunn et al. 2017] and ORNL/TM-2017/037 [Helmreich et al. 2017a].

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of a Solar Heat and Power Co-Generation System Final Report CRADA No. TC02152.0

This was a collaborative effort between Lawrence Livermore National Security, LLC as manager and operator of Lawrence Livermore National Laboratory (LLNL) and Tassajara Technologies, Inc. (TTI), to develop, fabricate and demonstrate a Solar Heat and Power Co-generation System. The technical objectives of this CRADA were to engineer, design and build a prototype Solar Thermal Process Heat and Power Demonstration System that would be suitable for use at the Arc of Hilo food processing facility. This would be accomplished in two phases. The first phase would entail the building of a prototype at Tassajara facilities. Base design parameters, including the subsystem interactions that would produce reliable performance at the lowest cost per watt of energy generated with the desired balance of power and heat to meet the requirements of the designated food processing applications from Arc of Hilo, would be provided by LLNL. The data and design development would be integrated into the second phase engine prototype and solar thermal system that would be built and delivered, with interface requirements to the Miko Building.

14 SOLAR ENERGY↗

AGR-2 Safety-Tested UCO Compact 6-4-2 PIE Report

As discussed in a previous report [Hunn et al. 2016] and reproduced in the following four paragraphs to provide background information and common terminology, post-irradiation examination (PIE) is being performed on tristructural-isotropic (TRISO) coated-particle fuel compacts from the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program second irradiation experiment (AGR-2) [Collin 2014]. This effort builds upon the understanding acquired throughout the AGR-1 PIE campaign [Demkowicz et al. 2015] and is establishing a database for the different AGR-2 fuel designs.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AGR-2 As-Irradiated UCO Compact 5-4-2 PIE Report

As discussed in a previous report [Hunn et al. 2016] and reproduced in the following three paragraphs to provide background information and common terminology, post-irradiation examination (PIE) is being performed on tristructural-isotropic (TRISO) coated-particle fuel compacts from the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program second irradiation experiment (AGR-2) [Collin 2014]. This effort builds upon the understanding acquired throughout the AGR-1 PIE campaign [Demkowicz et al. 2015] and is establishing a database for the different AGR-2 fuel designs.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Safety Testing and Post-Safety Test Examination of AGR-2 UCO Compact 2-3-2 and AGR-2 UO2 Compact 3-4-1

In this report, results from 1800°C safety testing and post-safety-test PIE of AGR-2 UCO Compact 2-3-2 and 1700°C safety testing of AGR-2 UO2 Compact 3-4-1 are discussed and compared to previously reported results from 1800°C safety testing of AGR-2 UCO Compact 5-4-1 and 1600°C safety testing of compact “twins”: AGR-2 UCO Compact 2-3-1 and AGR-2 UO 2 Compact 3-4-2. These compact pairs are called “twins” because their symmetric locations in the irradiation test train resulted in similar irradiation conditions. Table 1 shows the calculated burnup in percent fissions per initial metal atom (FIMA), the fast neutron fluence (neutron energies > 0.18 MeV), and the average compact temperatures during irradiation for these compacts. Capsule 2 Compacts 2-3-2 and 2-3-1 were intentionally irradiated at notably higher temperature than compacts in the other AGR-2 capsules or those previously studied in the AGR-1 irradiation test. The Capsule 2 compacts provide insight into the irradiation and post-irradiation safety test performance at higher temperatures than typical HTGR operating temperatures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measurement of Average Burnup in TRISO-Coated Particles from AGR-2 UCO Compacts 2-2-2 and 6-4-2

Burnup analysis was performed on tristructural-isotropic (TRISO)-coated particles deconsolidated from compacts irradiated by the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program in the second irradiation experiment (AGR-2) [Collin 2014]. The AGR-2 irradiation experiment included TRISO fuel particles with kernels containing both uranium oxide and uranium carbide, called UCO, where uranium carbide is included with the commonly-used uranium oxide in the kernel to provide a getter for oxygen liberated during fission and limit CO production. This allows the UCO-TRISO particles to be taken to higher burnup without failure from excessive internal CO pressure or CO-corrosion of the SiC layer. The UCO kernels were fabricated and coated at BWX Technologies Nuclear Operations Group (BWXT-NOG) with a 150-mm-diameter engineering-scale coater. The UCO-TRISO batch used in the AGR-2 irradiation experiment was Batch 93073, which had kernels with an average diameter of 426.7 μm and average coating thicknesses moving out from the kernel of 98.9 μm (buffer), 40.4 μm (IPyC), 35.2 μm (SiC), 43.4 μm (OPyC) [Barnes and Marshall 2009]. The TRISO particle were shipped to ORNL to be formed into compacts for irradiation testing. The compact lot qualified for the AGR-2 irradiation test was lot LEU09-OP2-Z and had an average of 3176 UCO-TRISO particles in each compact [Hunn, Montgomery, and Pappano 2010]. Compilations of the properties data for the particles and compacts are available in a pre-irradiation characterization summary report for the AGR-2 fuel composites [Hunn, Savage, and Silva 2010].

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗