Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FINS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Low-GWP Refrigerant Evaluation in AC Systems for High Ambient Temperature Applications – Acquire Nortek Residential AC/HP Units for Evaluation and Model the Units Using HPDM

For the upcoming refrigerant transition from HFCs to minorly flammable HFO refrigerants (A2L), refrigerant charge reduction is important to mitigate the fire hazard. Microchannel heat exchangers (MHXs) are a mature technology, which is effective in reducing system charge while maintaining similar heat transfer performance. MHXs will be applied more widely when the new refrigerants are used. Prior studies of the A2L HFO blends were mostly focused on fin-and-tube coils (FTC). An in-depth study for an air conditioner (AC)/heat pump (HP) system using all microchannel heat exchangers is still lacking. In FY19, a side-to-side comparison will be conducted between two residential split heat pumps, one using all FTCs and the other using all MHXs for drop-in investigation, to identify potential issues for future design. The two heat pumps have similar rated capacity, SEER, HSPF levels, similar fan, blower and compressor, but differ in heat exchangers. Both the HPs use two-stage compressors to facilitate investigating different refrigerant flow rates. We will drop-in HFO refrigerants (replacements for R-410A, e.g. R452B, R447B, R32, etc.). The experiments will reveal the potential of MHXs for charge reduction, and how the two systems using A2L refrigerants operate under standard SEER and HSPF rating conditions. The two units were donated by our partner, i.e. Nortek Global HVAC, an industry leader in making heat pumps using all MHXs as well as FTCs. The units were shipped to ORNL this week, and the product design data were also shared for modeling the two units using HPDM.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rotating Detonation Combustion for Gas Turbines: Modeling and System Synthesis to Exceed 65% Efficiency Goal (Phase II)

As of May 2019, all RDE test hardware and test operations were completed for this program. Over 700 hot fire tests were conducted at 4 facilities with 7 RDE assemblies, with the data available for future analysis. In particular, measured static and dynamic pressure and computational fluid dynamics (CFD) provided basis for pressure gain combustion (PGC) analysis of the Engineering Scale RDE. It was demonstrated via measurements and CFD that a carefully designed diffuser can recover some total pressure of the highly oscillatory RDE exhaust. In general, the isolator/injector is largest contributor of pressure losses; however a low loss design was demonstrated that improves significantly on previous natural-gas/air RDEs. Also, a tailored injector and mixing technique was demonstrated that allowed NG-air RDE operation with overall equivalence ratio of less than 0.6. CFD models by AR, the UofM and Purdue University were extensively used throughout the program to refine diffuser design for improved pressure recovery, to simulate injection and mixing, to estimate turbine interaction, to estimate combustor pressure gain anchored with test data and to provide input to other design and analytical tasks. CFD analyses were completed for many of the configurations tested at Purdue with the 13.4” RDE including the shark fin and low area ratio isolators. Results were compared favorably to available hot fire test particle image velocimetry (PIV) measurements and wave speeds. The results of these CFD analyses suggest a modest pressure gain of 33% with a sufficiently low area ratio isolator. A thermodynamic power plant system model was set up which utilizes an RDE combustor. The performance of the RDE combustor module was scaled based on measurements from the Engineering Scale RDE tests with low loss injector and tailored fuel flow. This combined model indicates potential for significant plant efficiency improvement. The successful tailored fuel injection test result with lower than .6 equivalence ratio has implication that a power plant can use a RDE combustor configuration where all the air flows through the combustion zone thereby not requiring a bypass mixer. In this configuration, the results of the natural gas combined cycle (NGCC) plant system indicate net efficiency of 66.4%.

02 PETROLEUM↗

Verification and Validation of the STAT7 Code

This document presents the verification and validation of the STAT7 Version 1.0 code which has been developed to perform the steady-state thermal hydraulic safety calculation of the MIT Research Reactor required upon conversion of the reactor from high enrichment uranium fuel to low enrichment uranium fuel. The key capabilites of the code including the statistical processing, water property generation, and thermal hydraulic solution are verified independently. While the first two capabilites are checked using statistical tests and NIST data tables, each component of the thermal hydraulic solution is verified using simple geometry test problems. The comparison between results obtained by the code and hand calculations on these problems shows that each of these components work correctly. Additionally, a comprehensive comparison between STAT7 Version 1.0 and PLTEMP/ANL Version 4.2 calculations for a five-channel test problem is performed for the validation. The good agreement between the obtained results for all thermal hydraulic parameters belonging to the fuel core region is achieved. An issue in bypass flowrate calculation was detected when both fin-friction and bypass flow claculations are involved. This problem can be corrected in a later version of the code, however, does not affect the application of STAT7 code as it has been used to date where the flow distribution in the core region and bypass channel is specified as an input parameter.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Revolutionizing Turbine Cooling with Micro-Architectures Enabled by Direct Metal Laser Sintering

The objective of this research effort was to explore innovative cooling architectures enabled by additive manufacturing techniques for improved turbine cooling performance. The ability to create complex internal geometries was leveraged to better distribute coolant as well as to integrate inherently unstable flow devices to enhance internal and external heat transfer. This was accomplished with a multi-faceted approach including analytical, experimental, and computational components. This final report documents progress during the total 4.25 year effort that was extended (at no additional cost) from the original 3-year cooperative agreement. Prior to starting the project, significant effort was invested in investigating innovative cooling designs from the open literature. When the project started, we quickly down-selected to 4 configurations: impingement jet fluidic oscillators (for internal leading edge cooling), reverse film cooling (for pressure surface), sweeping film cooling jets (for suction surface), and trailing edge slot cooling with microchannels. During the 2nd year, the reverse film cooling design was shown to be sub-optimal and work on that topic was halted. The three remaining technologies were integrated into a large scale nozzle guide vane and installed into a low-speed linear cascade facility for further interrogation. Initial results showed the sweeping film cooling jets (on the suction surface) to be the most promising technology compared to a baseline diffusion shaped film hole (777 design). The benefit was particularly evident at high blowing ratios (>1.5) when the 777 coolant film separated from the downstream surface. Benefits were also evident at elevated freestream turbulence levels. The leading edge cooling with unsteady jets was less effective in terms of peak or average cooling – however it was superior to round hole impingement cooling in terms of spatial uniformity. Finally, the trailing edge cooling design with micro-channels was scrapped in favor of a pinned arrangement with centerbody. During the 3rd year, the same three technologies were integrated into a transonic linear cascade for an assessment of compressibility effects. Again, the sweeping film cooling jets proved superior at high blowing ratios while the unsteady leading edge impingement and trailing edge pin-fins with centerbody designs yielded mixed results. Finally, during the 4th and final year, these 3 technologies were integrated into a direct metal laser sintered (DMLS) nozzle guide vane for testing in a high temperature, transonic annular vane cascade. The facility matches the flow temperature, Mach number, and coolant pressure ratios of an actual gas turbine. Before doing this, an additional series of tests were completed to validate a redesigned trailing edge cooling architecture. This final design included a centerbody with triangular pins between the centerbody and the vane external skin. The majority of these triangular pins are fabricated with a 30% gap to the centerbody – reducing their pressure drop considerably while still providing excellent heat transfer augmentation. This additional test campaign required an additional 3-month extension request to complete testing in the high temperature NGV test facility (Turbine Reacting Flow Rig – TuRFR). Testing of the DMLS vane in TuRFR pitted the 3 innovative cooling technologies against more traditional technologies (shaped 777 film hole, round impingement jet, and full pin arrangement in the trailing edge. The sweeping film cooling jets (on the suction surface) showed approximately 15% improvement in overall effectiveness compared to the 777 film hole while the trailing edge showed up to 20% improvement. The leading edge impingement was disappointing with a substantially lower effectiveness than traditional direct impingement. In summary, the study was successful in demonstrating that DMLS-enabled cooling technologies can yield significant gains in cooling performance.

03 NATURAL GAS↗

Verification and Validation of the STAT7 Code

This document presents the verification and validation of the STAT7 Version 1.0 code which has been developed to perform the steady-state thermal hydraulic safety calculation of the MIT Research Reactor required upon conversion of the reactor from highly enriched uranium fuel to low- enriched uranium fuel. The key capabilities of the code including the statistical processing, water property generation, and thermal hydraulic solution are verified independently. While the first two capabilities are checked using statistical tests and NIST data tables, each component of the thermal hydraulic solution is verified using simple geometry test problems. The comparison between results obtained by the code and hand calculations on these problems shows that each of these components work correctly. Additionally, a comprehensive comparison between STAT7 Version 1.0 and PLTEMP/ANL Version 4.2 calculations for a five-channel test problem is performed for the validation. The good agreement between the obtained results for all thermal hydraulic parameters belonging to the fuel core region is achieved. An issue in bypass flowrate calculation was detected when both fin-friction and bypass flow calculations are involved. This problem can be corrected in a later version of the code. However, it does not affect the application of STAT7 as it has been used to date where the flow distribution in the core region and bypass channel is specified as an input parameter.

97 MATHEMATICS AND COMPUTING↗

Advanced CMOS Reliability Update: Sub 20nm FinFET Assessment

Advances in FinFET design and fabrication enable manufacturing of denser, more compact integrated circuits (ICs) with substantially reduced leakage while shortening the channel-lengths. The same stress-induced leakage and breakdown degradation mechanisms that affect planar transistors also impact FinFET devices. Reliability concerns such as Bias Temperature Instability (BTI), Time Dependent Dielectric Breakdown (TDDB), and Hot Carrier Injection (HCI) become very important with changes to transistor geometry and fin sidewall crystal orientation. Recent testing has shown that FinFETs respond differently to radiation (radiation effects such as total ionizing dose) when compared to planar transistors. These reliability and radiation effects issues become very important when changing transistor geometry and scaling FinFETs towards smaller feature sizes (22-nm, 16-nm, 14- nm, 10-nm, and smaller critical dimensions). The comparable 2019 state of the art transistor densities in current high-volume manufacturing silicon-based foundries is 7-nm (ISMC, Samsung) and 10-nm (Intel) [www.anandtech.com,fuse.wikichip.org]. Released products include supporting components for the cellphone and commercial microprocessor markets respectively. Extensive development in the foundry industry is driving to a 5-nm technology node in late 2020.

47 OTHER INSTRUMENTATION↗

Integrated Heat Exchanger-Phase Change Material Thermal Energy Storage System

The purpose of this study is to experimentally investigate the thermal performance of an innovative thermal energy storage (TES) system that combines the advantages of the phase-change material (PCM)/graphite foam latent heat TES medium developed at Argonne National Laboratory (Argonne) and the internally supported plate-fin (ISPE) cell architecture heat transfer fluid (HTF) flow channels developed at Brayton Energy (Brayton). Several essential tasks were accomplished: (1) Thermal property characterization. Thermal properties of the graphite foam were characterized, providing necessary data for experimental result analysis and numerical simulation. (2) Design and optimization of lab-scale test module. Based on Brayton’s full-scale heat exchanger (HX)-TES system, the experimental test module was designed, optimized, and fabricated. (3) Thermal performance testing and data analysis. Five cycle tests were successfully conducted—including one with approximately 3.5 psig of pressure applied to the diaphragms—to investigate the thermal performance of the experimental test module for charging and discharging. Temperature profiles were generated for each charging test and discharging test as a function of time. The temperature profiles clearly show three TES stages: sensible heat (temperature increase), latent heat (melting), and sensible heat (temperature increase) for the charging process. Similarly, the temperature profiles clearly show three thermal energy release stages: sensible heat (temperature decrease), latent heat (solidification), and sensible heat (temperature decrease). Melting and solidification of the PCM generally occurred in relatively narrow temperature ranges, indicated by the flattened temperature regions in the temperature profiles. These phase changes ranged approximately 3°C for melting and 3.5°C for solidification. The charging and discharging temperature profiles were similar for similar experimental parameter tests whether or not pressure was applied to the diaphragm to eliminate the gap between the HX surface and the TES subsystem. This indicates that the effect of a small gap between the HX surface and the TES subsystem is insignificant for charging and discharging. (4) Comparison of experimental data and simulation results. We compared the experimental data to the numerical simulation results. Numerical simulations were conducted by using the ANSYS FLUENT 2019 R3 commercial computational fluid dynamics software. The predicted phase-change times agreed reasonably well with those from the experimental data. In most cases, the estimated time differences between the relative phase changes were within 16%. The predicted start and end times for the charging process agreed well with those from the experimental data. However, the simulation results showed earlier start and end times than the experimental data for the discharging process. Overall, the experimental data and its comparison with the simulation predictions verified the technical viability of the integrated ISPF HX-PCM/graphite foam latent-heat TES system.

25 ENERGY STORAGE↗

Measuring Heat Transfer Coefficients for Supercritical Carbon Dioxide Cycle Recuperators

This paper describes the measurement of convective heat transfer coefficients and friction factors for sCO 2 flowing in pin-fin patterned pipes at the US DoE’s National Energy Technology Laboratory (NETL) in Morgantown, WV. The measurement procedures were validated by conducting benchmark tests with smooth stainless-steel tube and comparing the results with published correlations for Nusselt number (𝑁𝑢) and friction factor. Over Reynolds numbers (Re D ) ranging from 5×104 to 2.5×105 , measured 𝑁𝑢 was within 5% of the Dittus-Boelter correlation and measured friction factors were within 5% of the McAdams correlation for smooth tube flow.

42 ENGINEERING↗

Computational Fluid Dynamics Simulations to Predict Oxidation in Heat Recovery Steam Generator Tubes

Heat Recovery Steam Generators (HRSGs) are widely used across United States in combined cycle power plants to recover waste heat from the gas turbine (GT). HRSGs are used either to generate electricity or to produce process steam for industrial applications. The primary components of HRSG consists of a duct and a heat exchanger (HX). It is known across the power industry that the high temperature oxidation and ensuing exfoliation problem is a major cause for the damage of HX materials of HRSG. Alloys and/or coatings that can prevent or mitigate oxidation are very expensive, therefore they must be used or applied on the select regions of the HX tubes where the tendency of oxide formation is the highest. The main goal of this project is to identify such regions through Computational Fluid Dynamics (CFD) simulations. Therefore, in this work, we developed a CFD framework using commercial code StarCCM+ for the prediction of the fluid flow and heat transfer in a HRSG and associated oxidation inside the tubes of the HX. The developed CFD framework was verified and validated with experimental data before deployment. We also developed an innovative method to model the effect of the fins on the heat transfer and the pressure drop using a porous media model (PMM) approach to keep the mesh size within reasonable limits. After validation, we performed high-fidelity CFD simulations of a real-scale HRSG using the PMM, with High Performance Computing (HPC) resources of ORNL. From the simulation results, we acquired oxide thickness maps for all the tubes of the select HX sections of HRSG prone to oxidation. These oxide maps can inform regions of the HX tubes that requires oxide-resistant coatings, thereby guiding engineers for cost-efficient manufacturing of the HX that can combat oxidation in HRSGs.

36 MATERIALS SCIENCE↗

Advanced Serpentine Heat Exchangers to Minimize Number of Joints and Leakage in HVAC&R Systems

Refrigerant leakage has a significant impact on heating, ventilation, air conditioning and refrigeration (HVAC&R) industries in terms of both greenhouse gas (GHG) emissions and lost efficiency of the systems themselves. One of the major causes of refrigerant leakage is braze joints within a vapor compression system. The brazing process is often inconsistent and almost always imperfect. As a result, braze joints are left vulnerable to leaks and can be weaker than non-brazed tubing. Conventional tube-fin heat exchangers are manufactured using one brazed joint per tube. An alternative to the conventional approach is the use of a single continuous serpentine tube. An Advanced Serpentine Heat Exchanger was developed to provide a heat transfer solution that meets or exceeds performance while also significantly reducing the number of joints and, consequently, the potential for refrigerant leakage. The developed serpentine heat exchanger not only delivers on performance, but is also cost competitive with conventional heat exchangers on the market.

30 DIRECT ENERGY CONVERSION↗

Exploring the Limits of Cooling for Extreme Heat Flux Applications: Data Centers and Power Electronic

We developed an Extreme Heat Flux Micro-cooler (EHFµ-C) capable of removing heat flux of ~1 kW/cm 2 with a small temperature rise ~10°C. This represents greater than 10× reduction in thermal resistance compared to the state-of-the-art single-phase cooling technologies (~0.5 cm 2 -°C/W) that greatly increases the efficiency, resulting in improved performance and reliability for microprocessors and power electronics. The EHFµ-Cooler utilizes liquid wicking (no pump) and thin-film evaporation in a 30 µm thick wick porous microstructure such as copper inverse opal (CIO), silicon and AlN pin fins along with a 3D manifold (copper wiremesh and silicon) with liquid routing and vapor extraction channels achieving an unprecedented vapor quality ~ >0.9. The proposed EHFµ-Cooler significantly reduces device temperature, resulting in 25-50% improvement in reliability and device performance. Based on very conservative estimates, the total energy saving for data centers due to improved performance can be 6 billion kWh/year (>$300M). Better cooling, leading to more efficient, higher performance and more reliable power electronics, would save the nation 3 Quad of primary energy in 2030. Just for automotive application, a 10% increase in fuel efficiency for SiC-based power electronics equates to >20 million gallons of fuel savings annually. The proposed EHFµ-Cooler technology ensures the United States maintains its technological lead in high-performance computing and high-power electronics, while at the same time improving the energy efficiency, and as a result reducing energy-related emissions such as greenhouse gases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design and Manufacturing of High Performance, Reduced Charge Heat Exchangers

Air-to-fluid heat exchangers (HXs) play a critical role as the main heat transfer component in Heating, Ventilation, Air-Conditioning, and Refrigeration (HVAC&R) systems. However, their airside thermal resistance significantly inhibits their overall performance. Furthermore, these HXs must be continually more compact to meet the latest refrigerant charge limits to reduce emissions. Recent literature suggests that traditional HX geometries (e.g., round or flat tubes with fins), have reached their limits, and more sophisticated shape- and topology-optimized designs are required to achieve the next jump in performance. This research sheds light on the next generation of air-to-refrigerant HXs and aims to address several practical issues to commercialization such as novelty challenges (improved performance for significant charge reduction; modeling expertise & time investment), manufacturing challenges (non-round tube manufacturing; tube-header integration; product qualification, e.g., burst pressure testing, extreme operational environment, etc.), and operational challenges (flow maldistribution, fouling & wetting, noise & vibration). For example, a >20% improvement on one (or more) HX-level performance metrics (e.g., envelope volume, airside pressure drop, face area, capacity, refrigerant charge, weight, cost, etc.) must be achieved before a HX design is considered for commercialization. We present a new, comprehensive and experimentally validated air-to-refrigerant HX optimization framework with simultaneous thermal-hydraulic performance and mechanical strength considerations for novel, non-round, shape- and topology-optimized tubes capable of optimizing single and two-phase HX designs for any refrigerant choice and performance requirement with significant engineering time savings compared to conventional design practices. The framework was exercised for a wide range of applications and refrigerants, resulting in HXs which achieved greater than 20% improved performance, 20% reductions in size, and 25% reductions in refrigerant charge. To enable non-round tube bundle use in next generation HVAC&R equipment, novel manufacturing techniques were investigated, including the development of conventional manufacturing methods for small diameter, non-round tubes and novel tube-header integration strategies. In total, ten HX prototypes were manufactured, nine using conventional methods directly attributed to this project and one using advanced additive manufacturing methods. The five-year manufacturing feasibility of the proposed HXs was found to have a good outlook. The non-round tube HX simulated performance was validated through comprehensive experimental testing, including nine in-house component-level tests, one independent component-level test at an industry partner laboratory, and in-house system-level tests of using a commercially-available, residential packaged A/C unit which was retrofitted with a non-round tube prototype HX. It was found that HX designs proposed by the new framework can successfully predict experimental thermal-hydraulic performance within ±10-20% the first time with no manual design changes, eliminating the need for time-consuming and expensive prototyping efforts. This work will accelerate design and time to market for next generation HXs while simultaneously facilitating industry transition to new refrigerants at lower charge.

42 ENGINEERING↗

Developing an Ultra-Compact, Topology-Optimized Heat Exchanger using Additive Manufacturing

Traditional heat exchanger designs have relied on a plate-fin architecture, assembled in a crossflow configuration. These HX designs are limited in their maximum allowable temperature and, therefore, efficiency. More advanced designs, such as those containing counter-flow, microtube cores, can yield higher efficiencies, but generally require complex headers. The design of such headers is usually determined based on user experience rather than on rigorous design tools, which can lead to lossy architectures; conventional headers can generate up to 50% of the total pressure loss through the HX. Furthermore, the consequences of manufacturing techniques are rarely considered during the design phase. Our team has developed an ultra-compact, topology-optimized heat exchanger capable of operating in environments with temperatures and pressures up to 800°C (1472°F) and 250 bar (3626 psi), respectively. Throughout the program, the team leveraged extensive additive manufacturing research and experience in supercritical carbon dioxide (sCO 2 ) power generation experience to develop and commercialize the technology. The final power density numbers for the subscale and full-scale heat exchangers are >15 kW/kg and >50 kW/L, which includes the core and the headers. The team has involved the RTX business units, notably Collins Aerospace, in discussions for commercializing the technology.

20 FOSSIL-FUELED POWER PLANTS↗

Development of an Integrated Thermal Energy Storage Heat Exchanger for Concentrating Solar Power

In this design and development effort a latent-heat energy storage heat exchanger was designed for a 10MW e sCO 2 power plant as a basis for detailed design and testing of a new phase-change heat exchanger technology. High efficiency thermal conductors of graphite foam or folded copper were employed within chloride salt phase-change volumes bounded by alternating high density compact plate-fin heat exchange cells in this new heat exchanger technology. Test articles were constructed at Brayton Energy and tested at Argonne National Laboratory. Copper-conducting samples were constructed and tested at Brayton Energy.

14 SOLAR ENERGY↗

3D Printing of Solar Absorber Tube with Internal/External Structures for Heat Transfer Enhancement and Temperature Leveling using Additive Manufacturing Technology

In this project, to tackle the technical obstacles, we utilized Laser Additive Alloying (LAA), an additive manufacturing (AM) technology, to 3D print the entire absorber tube with optimized helical fins to improve heat transfer at the expense of minimized pressure drop increase. The 3D printed absorber tubes can increase the uniformity of circumferential temperature distribution, reduced the thermal stresses, decrease the heat loss, and reach the target receiver thermal efficiency.

14 SOLAR ENERGY↗

Development of Additive Manufacturing for Ceramic Matrix Composite Vanes

This report discusses the development of additive manufacturing for polymer-derived ceramic materials to create novel cooled gas turbine airfoils made from ceramics. Gas turbine engines have extremely high temperatures in the hot section of the engine that exceed the melting point of nickel superalloy materials that the engine is made from. Advanced cooling technologies have been developed over decades for metallic parts. Ceramic materials have higher temperature capabilities than superalloys, but are difficult to shape in the complex designs used in modern turbines. Several thrusts were investigated during the project, including development of higher material strength resins, improvement of ultraviolet (UV) photopolymerization and post-processing techniques to increase survivability of ceramic parts, thermomechanical modeling of novel ceramic airfoil designs for higher cooling effectiveness, and experimental validation of the modeling and manufacturing in a turbine vane test facility at nondimensional conditions that are relevant to modern gas turbines. Some major findings of the work include a significant increase in ceramic survivability during pyrolysis (a high temperature process that converts the organic material to a ceramic) by adjusting the composition ratios of the resins, as well as a tolulene soak after printing to remove unreacted polymer material. Thermomechanical optimization of the internal cooling structure indicated that a high density pin fin array would enable an 80% increase in overall cooling effectiveness relative to a baseline geometry, which was later verified during experimental testing in a high speed linear cascade. Ceramic vanes were tested at Mach numbers of up to 0.9 which is relevant to modern gas turbines. High temperature capability of the ceramic vanes was not tested in this work.

36 MATERIALS SCIENCE↗

Multi-Physics Topology Optimization for Dual Flow Heat Exchangers

Current heat exchanger (HX) designs are subjected to strict constraints pertaining to their manufacturability through conventional lengthy and expensive processes consisting of subtractive, forming and brazing processes. Therefore, existing HXs are typically restricted to the classical and rather simple geometries, such as plate-fin or shell-tube geometries, with lower efficiency and larger size. To increase HX efficiencies, novel designs are needed. Recent advances in topology optimization (TO) and additive manufacturing (AM) offer significant flexibility in design and fabrication of complex geometries, with potentially superior thermo-mechanical performance and high-power density. On the other hand, there is no commercially available software tool that addresses the combined coupling of structural, fluid dynamics, and thermal with multiple materials (hot and cold streams, solid, and void space) in TO of HXs. The goal of this project is to develop a multi-physics multi-phase TO approach to enhance the performance of HXs. The optimized design will be additively manufactured and tested in a physical environment to quantify its performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of Frost Formation and Novel Defrost Techniques for Commercial Refrigeration Applications (NFE-19-07879)

The purpose of this Cooperative Research and Development Agreement (CRADA) was to test a heat exchanger defrosting approach using radiant energy, including ultraviolet-C, -B, and -A. A preliminary test conducted at Oak Ridge National Laboratory demonstrated the concept of ultraviolet-based defrosting, which melts frost on the fin surface of a heat exchanger without increasing its overall temperature, thereby offering a new defrosting method that does not interrupt heat exchanger operation. Building on this key finding, this CRADA outlines a plan for upgrading the test equipment and for further testing to bridge the gap between the concept and its feasibility for industrial applications. This report also provides a brief review of existing defrosting technologies, the current state of the experimental system, and future parametric experiment plans.

99 GENERAL AND MISCELLANEOUS↗