Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FINGERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Issues in human/computer control of dexterous remote hands

Much research on dexterous robot hands has been aimed at the design and control problems associated with their autonomous operation, while relatively little research has addressed the problem of direct human control. It is likely that these two modes can be combined in a complementary manner yielding more capability than either alone could provide. While many of the issues in mixed computer/human control of dexterous hands parallel those found in supervisory control of traditional remote manipulators, the unique geometry and capabilities of dexterous hands pose many new problems. Among these are the control of redundant degrees of freedom, grasp stabilization and specification of non-anthropomorphic behavior. An overview is given of progress made at the MIT AI Laboratory in control of the Salisbury 3 finger hand, including experiments in grasp planning and manipulation via controlled slip. It is also suggested how we might introduce human control into the process at a variety of functional levels.

Salisbury, K.↗

Report on the Stanford/Ames direct-link space suit prehensor

Researchers at the Center for Design Research at Stanford University, in collaboration with NASA Ames at Moffet Field, California, are developing hand-powered mechanical prehensors to replace gloves for EVA spacesuits. The design and functional properties of the first version Direct Link Prehensor (DLP) is discussed. It has a total of six degrees-of-freedom and is the most elaborate of three prehensors being developed for the project. The DLP has a robust design and utilizes only linkages and revolute joints for the drive system. With its anthropomorphic configuration of two fingers and a thumb, it is easy to control and is capable of all of the basic prehension patterns such as cylindrical or lateral pinch grasps. Kinematic analysis reveals that, assuming point contacts, a grasped object can be manipulated with three degrees-of-freedom. Yet, in practice more degrees-of-freedom are possible.

Jameson, J. W.↗

Concept development of a tendon arm manipulator and anthropomorphic robotic hand

AMETEK/ORED inhouse research and development efforts leading toward a next-generation robotic manipulator arm and end-effector technology is summarized. Manipulator arm development has been directed toward a multiple-degree-of-freedom, flexible, tendon-driven concept referred to here as a Tendon Arm Manipulator (TAM). End-effector development has been directed toward a three-fingered, dextrous, tendon-driven, anthropomorphic configuration which is referred to as an Anthropomorphic Robotic Hand (ARH). Key technology issues are identified for both concepts.

Tolman, C. T.↗

Symbolic derivation of material property matrices in finite element analysis

The principles and operation of MMAX, a symbolic-computation program which automates the process of generating property matrices for structural materials, are briefly described and illustrated with sample analyses of a rubberlike material and an elastoplastic material. MMAX is written in LISP under the symbolic finite-element generator FINGER and the general symbolic manipulator MACSYMA; it first derives the formulas required by mathematical manipulation, and then translates the formulas into FORTRAN code, adapted to the particular type of machine to be used for the numerical calculations. This approach is shown to combine efficiently the advantages of symbolic and numerical computation for engineering applications.

Tan, H. Q.↗

Radio emission from young supernova remnants - Effects of an inhomogeneous circumstellar medium

The evolution of young supernova remnants has been modeled using a one-dimensional hydrodynamics code. Rayleigh-Taylor instabilities and the growth of Rayleigh-Taylor fingers have been included in the code. Turbulent dynamo amplification of magnetic fields and both turbulent and shock acceleration of relativistic electrons have been included macroscopically. From this, the distribution of synchrotron luminosity in the remnant has been calculated. It is found that the radio morphology of model remnants expanding into a homogeneous medium does not agree with observations. Expansion into a circumstellar medium with many small cloudlets does produce radio shells which agree with observations. It is suggested that supernova remnants reflect the interaction of ejected matter with a cloudy circumstellar medium.

Dickel, John R.↗

The growth of ZnSe single crystals by physical vapor transport

ZnSe single crystals have been grown in sealed quartz ampoules by the physical vapor transport method. Complete transport of the starting material and single site growth have been achieved with no material adhering to the ampoule wall. Growth is initiated in a narrow channel in the cold finger attached to the growth end of the ampoule. The highest growth rate to date has been 280 mg/day which corresponds to an average transport rate of about 1.93 mmol/day. The largest single crystal, measuring 1 cm x 4 mm x 2 mm, had a total growing time of 11 days or an average growth rate of 171 mg/day.

Cheng, Hai-Yuin↗

Inhomogeneous diffusion-limited aggregation

It is demonstrated here that inhomogeneous diffusion-limited aggregation (DLA) model can be used to simulate viscous fingering in a medium with inhomogeneous permeability and homogeneous porosity. The medium consists of a pipe-pore square-lattice network in which all pores have equal volume and the pipes have negligible volume. It is shown that fluctuations in a DLA-based growth process may be tuned by noise reduction, and that fluctuations in the velocity of the moving interface are multiplicative in form.

Selinger, Robin Blumberg↗

Handling and analysis of ices in cryostats and glove boxes in view of cometary samples

Comet nucleus sample return mission and other return missions from planets and satellites need equipment for handling and analysis of icy samples at low temperatures under vacuum or protective gas. Two methods are reported which were developed for analysis of small icy samples and which are modified for larger samples in cometary matter simulation experiments (KOSI). A conventional optical cryostat system was modified to allow for transport of samples at 5 K, ion beam irradiation, and measurement in an off-line optical spectrophotometer. The new system consists of a removable window plug containing nozzles for condensation of water and volatiles onto a cold finger. This plug can be removed in a vacuum system, changed against another plug (e.g., with other windows (IR, VIS, VUV) or other nozzles). While open, the samples can be treated under vacuum with cooling by manipulators (cut, removal, sample taking, irradiation with light, photons, or ions). After bringing the plug back, the samples can be moved to another site of analysis. For handling the 30 cm diameter mineral-ice samples from the KOSI experiments an 80x80x80 cm glove box made out of plexiglass was used. The samples were kept in a liquid nitrogen bath, which was filled from the outside. A stream a dry N2 and evaporating gas from the bath purified the glove box from impurity gases and, in particular, H2O, which otherwise would condense onto the samples.

Roessler, K.↗

Rod gripper, changer, and storage system

A rod changer and storage design is presented for the lunar deep drill apparatus to be used in conjunction with the Skitter walking platform. The design must take into account all of the lunar environment and working conditions. Some of these are: (1) the moon has one sixth the gravity of earth; (2) temperature gradients can range from about -170 to 265 C; (3) because of the high transportation costs, the design must be as light as possible; and (4) the process must be remotely operated (from earth or satellite) and must be automated. Because of Skitter's multiple degree of freedom movement, the design will utilize Skitter's movement to locate an implement and transport it from the rack to the drill string. The implement will be gripped by a thumb and two finger device, identified through an electronic sensing device on the thumb, and transported from the rack to the footplate and back from the footplate to the rack. The major designs discussed in this report have been broken down into three major areas: (1) gripper design (linear transport mechanism); (2) indexing system; and (3) rack design.

Benson, Mark↗

Autonomous dexterous end-effectors for space robotics

The development of a knowledge-based controller is summarized for the Belgrade/USC robot hand, a five-fingered end effector, designed for maximum autonomy. The biological principles of the hand and its architecture are presented. The conceptual and software aspects of the grasp selection system are discussed, including both the effects of the geometry of the target object and the task to be performed. Some current research issues are presented.

Bekey, George A.↗

The JAU-JPL anthropomorphic telerobot

Work in progress on the new anthropomorphic telerobot is described. The initial robot configuration consists of a seven DOF arm and a sixteen DOF hand, having three fingers and a thumb. The robot has active compliance, enabling subsequent dual arm manipulations. To control the rather complex configuration of this robot, an exoskeleton master arm harness and a glove controller were built. The controller will be used for teleoperational tasks and as a research tool to efficiently teach the computer controller advanced manipulation techniques.

Jau, Bruno M.↗

Finite element simulations of thermosolutal convection in vertical solidification of binary alloys

Dendritic vertical solidification of a binary alloy is modeled using the finite element method to assess the effect of thermosolutal convection in macrosegregation. The mathematical model assumes steady-state solidification with a planar, undeformable surface defined by the dendrite tips and the eutectic isotherm. The dendritic region is assumed to advance at a constant solidification velocity v. The stability of the modeled system has been investigated and nonlinear calculations performed that show finger-like convection when the system is unstable. Results for lead-tin alloys show that when the system is unstable, convection is only significant in the uppermost part of the mush and is entirely driven by convection in the bulk fluid.

Heinrich, J. C.↗

The stability of individual patterns of autonomic responses to motion sickness stimulation

As part of a program to develop a treatment for motion sickness based on self-regulation of autonomic nervous system (ANS) activity, this study examined the stability of an individual's pattern of ANS responses to motion sickness stimulation on repeated occasions. Motion sickness symptoms were induced in 58 people during two rotating chair test. Physiological responses measured were heart rate, finger pulse volume, respiration rate, and skin conductance. Using standard scores, stability of responses of specific magnitudes across both tests is as examined. Correlational analyses, analysis of variance, and a components of variance analysis all revealed marked, but quite stable, individual differences in ANS responses to both mild and severe motion sickness. These findings confirm the prior observation that people are sufficiently unique in their ANS responses to motion sickness provocation to make it nesessary to individually tailor self-regulation training. Further, these data support the contention that individual ANS patterns are sufficiently consistent from test to test so as to serve as an objective indicator of individual motion sickness malaise levels.

Cowings, Patricia S.↗

Work/control stations in Space Station weightlessness

An ergonomic integration of controls, displays, and associated interfaces with an operator, whose body geometry and dynamics may be altered by the state of weightlessness, is noted to rank in importance with the optimal positioning of controls relative to the layout and architecture of 'body-ported' work/control stations applicable to the NASA Space Station Freedom. A long-term solution to this complex design problem is envisioned to encompass the following features: multiple imaging, virtual optics, screen displays controlled by a keyboard ergonomically designed for weightlessness, cursor control, a CCTV camera, and a hand-controller featuring 'no-grip' vernier/tactile positioning. This controller frees all fingers for multiple-switch actuations, while retaining index/register determination with the hand controller. A single architectural point attachment/restraint may be used which requires no residual muscle tension in either brief or prolonged operation.

Willits, Charles↗

Rotationally Actuated Prosthetic Hand

Prosthetic hand attached to end of remaining part of forearm and to upper arm just above elbow. Pincerlike fingers pushed apart to degree depending on rotation of forearm. Simpler in design, simpler to operate, weighs less, and takes up less space.

Norton, William E.↗

Anthropomorphic Remote Manipulator

Two-armed telerobot undergoing development manipulates objects with dexterity approaching that of human. Designed to be remotely operated by human. Operator wears harness with exoskeletonlike sleeves and gloves; remote manipulator follows operator's arm, hand, and finger movements and feeds back position and force information so operator has sense of manipulating object held by telerobot. Developed for use in outer space. Suited for such terrestrial uses as handling materials and maintaining equipment in hazardous environments where mechanical dexterity and nearly instantaneous feedback of sensory information needed.

Jau, Bruno M.↗

Probing the Interstellar Medium of External Galaxies Using Quasar Absorption Lines: the 3C 232/NGC 3067 System

Quasar absorption lines offer unique opportunities to probe the interstellar medium of external galaxies. Researchers present new optical and UV absorption line spectroscopy of the quasar 3C232 (z=0.55) revealing new detail in the foreground absorption system due to the bright, spiral galaxy NGC 3067 (cz=1420 km/s). Specifically, the spectra show evidence for two and possibly three separate absorption components in CaII and Na I spanning approx. 150 km/s. The original HI detection of Haschick and Burke (1975) corresponds to the strongest of these metal systems which exhibits doublet ratios consistent with saturation in both CaII and Na I. Due to the recent detection in HI emission of a tidal tail or finger of HI extending from the western edge of NGC 3067 through the position of 3C 232 (Carilli, van Gorkom and Stocke, 1989), the morphology of the HI absorber is now known and is not either a warped disk nor a spherical halo as had been proposed. New deep continuum and H alpha imaging provides a sensitive upper limit on the the ionizing continuum impinging upon this cloud (and thus a limit on the intensity of the extragalactic ionizing radiation field). Together with the observed UV spectrum of 3C 232, the optical emission line ratios and the deep H alpha imaging set a minimum distance between the quasar and the HI cloud disregarding redshift information. This limit strains the non-cosmological redshift interpretation for 3C 232 -- and this quasar is one of the original 5 3C quasars found to be too close to NGC galaxies as if by chance (Burbidge, Burbidge, Solomon and Strittmatter, 1972).

Stocke, John T.↗

Spiral lead platen robotic end effector

A robotic end effector is disclosed which makes use of a rotating platen with spiral leads used to impact lateral motion to gripping fingers. Actuation is provided by the contact of rolling pins with the walls of the leads. The use of the disclosed method of actuation avoids jamming and provides excellent mechanical advantage while remaining light in weight and durable. The entire end effector is compact and easily adapted for attachment to robotic arms currently in use.

Beals, David C.↗