Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Environmental Sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Laser Ablation Surface Treatment of Structural Aerospace Composites and Metal Alloys for Adhesive Bonding

NASA Langley Research Center (LaRC) has been involved over the past decade in the development of laser ablation as a method to surface treat aerospace structural fiber reinforced composites (CFRPs) and metal alloys. [1- 18] Laser surface treatment has been shown to be a rapid, high precision, and reproducible method for surface treatment of these materials, and is amenable to automation. The laser ablation process removes surface contamination such as silicones, creates surface roughness, and chemically activates a surface for bonding. The degree of ablation is controllable by adjusting laser parameters. In the case of CFRPs, ablation can be performed without damage to any underlying carbon fibers. In the case of metal alloys, ablation is possible without surface embrittlement, heat damage or creation of undesirable grain structures or morphologies. The optimum laser treatment conditions are substrate dependent and generally are influenced by laser wavelength and pulse duration (typically fixed for a laser system), and laser power. In the case of metal alloys such as Ti-6Al-4V, the laser ablation process eliminates the need for several steps of the conventional processes, including hydrofluoric (HF) acid and caustic treatment. These steps are often conducted in dip tanks and require costly facilities and environmentally unfriendly liquids. In addition, the laser can create nano-porosity on the Ti-6Al-4V alloy surface allowing for sol-gel penetration and thereby creating a gradient interface with improved temperature and mechanical performance. NASA LaRC has also been involved with the development of in-line characterization methods compatible with the laser treatment process to rapidly determine the presence of key contaminates such as silicones that, even at very low concentrations, are a threat to adhesive bonding. A spectroscopic technique called micro-laser induced breakdown spectroscopy (u-LIBS) has been developed to rapidly detect silicones at concentrations below those known to cause bonding problems. This technique requires no sample preparation, vacuum or inert atmosphere, has no practical size limitations, and provides nearly instantaneous feedback to the operator. This presentation will give an overview and update of these developments with specific examples highlighted.

Connell, John W.↗

Seasonal and Diurnal Opportunities for XCH4, XCO2, and XCO for the Amazonian Rainforest Region Allowing Sampling and Validation

There is considerable interest in the aggregate methane emissions from the Amazon and similar moist tropical regions, and XCH4 measurements are well suited to constrain sources to the global atmosphere. Similarly, XCO2 measurements constrain CO2 in the region. XCO helps to partition CO2 patterns among burning and respiration processes. GeoCarb may allow these column measurements over the Western Hemisphere, but satellite retrieval require exacting calibration and validation by sun-focused Fourier transform spectrometers (FTS). The rarity of sufficiently large gaps in the cloud cover over the Amazon and similar rainforests restricts the validation opportunities for useful FTS observations and even more the opportunities for accurate retrievals. TropOMI observational statistics are extremely poor for the region. We have used two data sources to evaluate FTS opportunities at Manaus, Brazil, an FTS operated for 8 months near Manaus by Mavendra Dubey, and also sun-photometer measurements at several stations. The promise of using data from other satellites, e.g. GOES-16 ( (Geostationary Operational Environmental Satellite) and CALIOP (Cloud-Aerosol LIdar with Orthogonal Polarization gaps and aerosol layering will be described. We report initial results on five questions: (1) how frequent are observing opportunities of FTS?, (2) What evidence is there that gaps in clouds are wide enough for satellite retrievals at an appropriate accuracy, (3) What is the diurnal and seasonal variability of cloud gaps?, and (4) What limitations are currently suggested for unbiased FTS measurement of XCH4 due to diurnal effects, and (5) What evidence is there for incidence of problematic high aerosol extinction at higher layers of the troposphere (800 hPa to 120 hPa) which alter the XCH4 light-paths?

Chatfield, Robert↗

The use of LANDSAT-1 imagery for water quality studies in southern Scandinavia

The possibilities of using LANDSAT-1 images for environmental studies, with special references to water quality studies, were investigated by selecting test areas in southern Scandinavia. The MSS images of different bands are compared under the magnification of an Interpretoscope and densitometric analyses are performed in a Schnell-photometer. The possibility of tracing pollution plumes is studied in the Oresund outside Copenhagen. The effect of different sewers and the circulation of the polluted water is analyzed in various situations. The variation in reflectivity of a great number of lakes in South and Middle Sweden is studied by means of densitometric analyses and significant regional differences are found. The correlation with in situ measurements of water quality (turbidity and secchi disc transparency) of the sampled lakes (made by the National Swedish Environment Protection Board) is fairly good.

Hellden, U.↗

Feasibility of an integrated X-ray instrument for Mars exobiology and geology

By employing an integrated X-ray instrument on a future Mars mission, data obtained will greatly augment those returned by Viking; details relevant to the possibility of the origin and evolution of life on Mars will be acquired. An integrated combined X Ray Fluorescence/X Ray Detection (XRF/XRD) instrument has been breadboarded and demonstrated to accommodate important exobiology and geology experiment objectives outlined for Mars Environmental Survey (MESUR) and future Mars missions. Among others, primary objectives for the exploration of Mars include: the intense study of local areas on Mars to 'establish the chemical, mineralogical, and petrological character of different components of the surface material; to determine the distribution, abundance and sources and sinks of volatile materials, including an assessment of the biologic potential, now and during past epochs; and to establish the global chemical and physical characteristics of the Martian surface'. The XRF/XRD breadboard instrument identifies and quantifies soil surface elemental, mineralogical, and petrological characteristics and acquires data necessary to address questions on volatile abundance and distribution. Additionally, the breadboard is able to characterize the biogenic element constituents of soil samples providing information on the biologic potential of the Mars environment.

Fonda, M. L.↗

Fungal colonization of fiberglass insulation in the air distribution system of a multi-story office building: VOC production and possible relationship to a sick building syndrome

Complaints characteristic of those for sick building syndrome prompted mycological investigations of a modern multi-story office building on the Gulf coast in the Southeastern United States (Houston-Galveston area). The air handling units and fiberglass duct liner of the heating, ventilating and air conditioning system of the building, without a history of catastrophic or chronic water damage, demonstrated extensive colonization with Penicillium spp and Cladosporium herbarum. Although dense fungal growth was observed on surfaces within the heating-cooling system, most air samples yielded fewer than 200 CFU m-3. Several volatile compounds found in the building air were released also from colonized fiberglass. Removal of colonized insulation from the floor receiving the majority of complaints of mouldy air and continuous operation of the units supplying this floor resulted in a reduction in the number of complaints.

NASA Program Environmental Health↗

Ballooning for Biologists: Mission Essentials for Flying Life Science Experiments to Near Space

Despite centuries of scientific balloon flights, only a handful of experiments have produced biologically-relevant results. Yet unlike orbital spaceflight, it is much faster and cheaper to conduct biology research with balloons, sending specimens to the near space environment of Earth’s stratosphere. Samples can be loaded the morning of a launch and sometimes returned to the laboratory within one day. The National Aeronautics and Space Administration (NASA) flies large, unmanned scientific balloons from all over globe, with missions ranging from hours to weeks in duration. A payload in the middle portion of the stratosphere (~35 km above sea level) will be exposed to an environment similar to the surface of Mars: temperatures as cold as -100 °C, atmospheric pressure at a thin 0.9 kPa, relative humidity levels < 1%, and a harsh illumination of ultraviolet (UV) and cosmic radiation levels (about 100 W/m 2 and 0.07 mGy/d, respectively) that can be obtained nowhere else on the surface of the Earth, including environmental chambers and particle accelerator facilities attempting to simulate space radiation effects. Considering operational advantages of ballooning and the fidelity of space-like stressors in the stratosphere, researchers in aerobiology, astrobiology, and space biology can benefit from balloon flight experiments as an intermediary step on the extraterrestrial continuum (ground, low Earth orbit, and deep space studies). Our review targets biologists with no background or experience in scientific ballooning. We will provide an overview of balloon operations, topics that can be uniquely addressed in the stratosphere, and a roadmap for developing payloads to fly with NASA.

NASA Balloon Program↗

Rationally designed fluorescently labeled sulfate-binding protein mutants: evaluation in the development of a sensing system for sulfate

Periplasmic binding proteins from E. coli undergo large conformational changes upon binding their respective ligands. By attaching a fluorescent probe at rationally selected unique sites on the protein, these conformational changes in the protein can be monitored by measuring the changes in fluorescence intensity of the probe which allow the development of reagentless sensing systems for their corresponding ligands. In this work, we evaluated several sites on bacterial periplasmic sulfate-binding protein (SBP) for attachment of a fluorescent probe and rationally designed a reagentless sensing system for sulfate. Eight different mutants of SBP were prepared by employing the polymerase chain reaction (PCR) to introduce a unique cysteine residue at a specific location on the protein. The sites Gly55, Ser90, Ser129, Ala140, Leu145, Ser171, Val181, and Gly186 were chosen for mutagenesis by studying the three-dimensional X-ray crystal structure of SBP. An environment-sensitive fluorescent probe (MDCC) was then attached site-specifically to the protein through the sulfhydryl group of the unique cysteine residue introduced. Each fluorescent probe-conjugated SBP mutant was characterized in terms of its fluorescence properties and Ser171 was determined to be the best site for the attachment of the fluorescent probe that would allow for the development of a reagentless sensing system for sulfate. Three different environment-sensitive fluorescent probes (1,5-IAEDANS, MDCC, and acylodan) were studied with the SBP171 mutant protein. A calibration curve for sulfate was constructed using the labeled protein and relating the change in the fluorescence intensity with the amount of sulfate present in the sample. The detection limit for sulfate was found to be in the submicromolar range using this system. The selectivity of the sensing system was demonstrated by evaluating its response to other anions. A fast and selective sensing system with detection limits for sulfate in the submicromolar range was developed. Copyright 2002 Wiley Periodicals, Inc. Biotechnol Bioeng 78: 517-526, 2002.

Evaluation Studies↗

Syringe filtration methods for examining dissolved and colloidal trace element distributions in remote field locations

It is well-established that sampling and sample processing can easily introduce contamination into dissolved trace element samples if precautions are not taken. However, work in remote locations sometimes precludes bringing bulky clean lab equipment into the field and likewise may make timely transport of samples to the lab for processing impossible. Straightforward syringe filtration methods are described here for collecting small quantities (15 mL) of 0.45- and 0.02-microm filtered river water in an uncontaminated manner. These filtration methods take advantage of recent advances in analytical capabilities that require only small amounts of waterfor analysis of a suite of dissolved trace elements. Filter clogging and solute rejection artifacts appear to be minimal, although some adsorption of metals and organics does affect the first approximately 10 mL of water passing through the filters. Overall the methods are clean, easy to use, and provide reproducible representations of the dissolved and colloidal fractions of trace elements in river waters. Furthermore, sample processing materials can be prepared well in advance in a clean lab and transported cleanly and compactly to the field. Application of these methods is illustrated with data from remote locations in the Rocky Mountains and along the Yukon River. Evidence from field flow fractionation suggests that the 0.02-microm filters may provide a practical cutoff to distinguish metals associated with small inorganic and organic complexes from those associated with silicate and oxide colloids.

Colloids/analysis↗

Compound Specific Hydrogen Isotope Composition of Type II and III Kerogen Extracted by Pyrolysis-GC-MS-IRMS

The use of Hydrogen (H) isotopes in understanding oil and gas resource plays is in its infancy. Described here is a technique for H isotope analysis of organic compounds pyrolyzed from oil and gas shale-derived kerogen. Application of this technique will progress our understanding. This work complements that of Pernia et al. (2013, this meeting) by providing a novel method for the H isotope analysis of specific compounds in the characterization of kerogen extracted by analytically diverse techniques. Hydrogen isotope analyses were carried out entirely "on-line" utilizing a CDS 5000 Pyroprobe connected to a Thermo Trace GC Ultra interfaced with a Thermo MAT 253 IRMS. Also, a split of GC-separated products was sent to a DSQ II quadrupole MS to make semi-quantitative compositional measurements of the extracted compounds. Kerogen samples from five different basins (type II and III) were dehydrated (heated to 80 C overnight in vacuum) and analyzed for their H isotope compositions by Pyrolysis-GC-MS-TC-IRMS. This technique takes pyrolysis products separated via GC and reacts them in a high temperature conversion furnace (1450 C) which quantitatively forms H2, following a modified method of Burgoyne and Hayes, (1998, Anal. Chem., 70, 5136-5141). Samples ranging from approximately 0.5 to 1.0mg in size, were pyrolyzed at 800 C for 30s. Compounds were separated on a Poraplot Q GC column. Hydrogen isotope data from all kerogen samples typically show enrichment in D from low to high molecular weight compounds. Water (H2O) average deltaD = -215.2 (V-SMOW), ranging from -271.8 for the Marcellus Shale to -51.9 for the Polish Shale. Higher molecular weight compounds like toluene (C7H8) have an average deltaD of -89.7 0/00, ranging from -156.0 for the Barnett Shale to -50.0 for the Monterey Shale. We interpret these data as representative of potential H isotope exchange between hydrocarbons and sediment pore water during formation within each basin. Since hydrocarbon H isotopes readily exchange with water, these data may provide some useful information on gas-water or oil-water interaction in resource plays, and further as a possible indicator of paleo-environmental conditions. Alternatively, our data may be an indication of H isotope exchange with water and/or acid during the kerogen isolation process. Either of these interpretations will prove useful when deciphering H isotope data derived from kerogen analysis. More experiments are planned to discern these two or other possible scenarios.

Socki, Richard A.↗

Assessment of NO2 Observations During DISCOVER-AQ and KORUS-AQ Field Campaigns

NASA’s Deriving Information on Surface Conditions from Column and Vertically Resolved Observations Relevant to Air Quality (DISCOVER-AQ, conducted in 2011–2014) campaign in the United States and the joint NASA and National Institute of Environmental Research (NIER) Korea–United States Air Quality Study (KORUS-AQ, conducted in 2016) in South Korea were two field study programs that provided comprehensive, integrated data sets of airborne and surface observations of atmospheric constituents, including nitrogen dioxide (NO2), with the goal of improving the interpretation of spaceborne remote sensing data. Various types of NO2 measurements were made, including in situ concentrations and column amounts of NO2 using ground- and aircraft-based instruments, while NO2 column amounts were being derived from the Ozone Monitoring Instrument (OMI) on the Aura satellite. This study takes advantage of these unique datasets by first evaluating in situ data taken from two different instruments on the same aircraft platform, comparing coincidently sampled profile-integrated columns from aircraft spirals with remotely sensed column observations from ground-based Pandora spectrometers, intercomparing column observations from the ground (Pandora), aircraft (in situ vertical spirals), and space (OMI), and evaluating NO2 simulations from coarse Global Modeling Initiative (GMI) and high-resolution regional models. We then use these data to interpret observed discrepancies due to differences in sampling and deficiencies in the data reduction process. Finally, we assess satellite retrieval sensitivity to observed and modeled a priori NO2 profiles. Contemporaneous measurements from two aircraft instruments that likely sample similar air masses generally agree very well but are also found to differ in integrated columns by up to 31.9 %. These show even larger differences with Pandora, reaching up to 53.9 %, potentially due to a combination of strong gradients in NO2 fields that could be missed by aircraft spirals and errors in the Pandora retrievals. OMI NO2 values are about a actor of 2 lower in these highly polluted environments due in part to inaccurate retrieval assumptions (e.g., a priori pro-files) but mostly to OMI’s large footprint (>312 km2).

Nitrogen dioxide↗

Design and Analysis of an Isokinetic Sampling Probe for Submicron Particle Measurements at High Altitude

An isokinetic dilution probe has been designed with the aid of computational fluid dynamics to sample sub-micron particles emitted from aviation combustion sources. The intended operational range includes standard day atmospheric conditions up to 40,000-ft. With dry nitrogen as the diluent, the probe is intended to minimize losses from particle microphysics and transport while rapidly quenching chemical kinetics. Initial results indicate that the Mach number ratio of the aerosol sample and dilution streams in the mixing region is an important factor for successful operation. Flow rate through the probe tip was found to be highly sensitive to the static pressure at the probe exit. Particle losses through the system were estimated to be on the order of 50% with minimal change in the overall particle size distribution apparent. Following design refinement, experimental testing and validation will be conducted in the Particle Aerosol Laboratory, a research facility located at the NASA Glenn Research Center to study the evolution of aviation emissions at lower stratospheric conditions. Particle size distributions and number densities from various combustion sources will be used to better understand particle-phase microphysics, plume chemistry, evolution to cirrus, and environmental impacts of aviation.

Heath, Christopher M.↗

Ballooning for Biologists: Mission Essentials for Flying Experiments on Large NASA Balloons

Despite centuries of scientific balloon flights, only a handful of experiments have produced biologically-relevant results. Yet unlike orbital spaceflight, it is much faster and cheaper to conduct biology research with balloons, sending specimens to the near space environment of Earths stratosphere. Samples can be loaded the morning of a launch and sometimes returned to the laboratory within one day after flying. The National Aeronautics and Space Administration (NASA) flies large, unmanned scientific balloons from all over the globe, with missions ranging from hours to weeks in duration. A payload in the middle portion of the stratosphere (approx. 35 km above sea level) will be exposed to an environment similar to the surface of Mars: temperatures generally around -36 C, atmospheric pressure at a thin 1 kPa, relative humidity levels <1%, and a harsh illumination of ultraviolet (UV) and cosmic radiation levels (about 100 W/sq m and 0.1 mGy/d, respectively) that can be obtained nowhere else on the surface of the Earth, including environmental chambers and particle accelerator facilities attempting to simulate space radiation effects. Considering the operational advantages of ballooning and the fidelity of space-like stressors in the stratosphere, researchers in aerobiology, astrobiology, and space biology can benefit from balloon flight experiments as an intermediary step on the extraterrestrial continuum (ground, low Earth orbit, and deep space studies). Our presentation targets biologists with no background or experience in scientific ballooning. We will provide an overview of large balloon operations, biology topics that can be uniquely addressed in the stratosphere, and a roadmap for developing payloads to fly with NASA.

Smith, David J.↗

Cognitive Performance in ISS Astronauts on 6-Month Low Earth Orbit Missions

Introduction: Current and future astronauts will endure prolonged exposure to spaceflight hazards and environmental stressors that could compromise cognitive functioning, yet cognitive performance in current missions to the International Space Station remains critically under-characterized. We systematically assessed cognitive performance across 10 cognitive domains in astronauts on 6-month missions to the ISS. Methods: Twenty-five professional astronauts were administered the Cognition Battery as part of National Aeronautics and Space Administration (NASA) Human Research Program Standard Measures Cross-Cutting Project. Cognitive performance data were collected at five mission phases: pre-flight, early flight, late flight, early post-flight, and late post-flight. We calculated speed and accuracy scores, corrected for practice effects, and derived z-scores to represent deviations in cognitive performance across mission phases from the sample’s mean baseline (i.e., pre-flight) performance. Linear mixed models with random subject intercepts and pairwise comparisons examined the relationships between mission phase and cognitive performance. Results: Cognitive performance was generally stable over time with some differences observed across mission phases for specific subtests. There was slowed performance observed in early flight on tasks of processing speed, visual working memory, and sustained attention. We observed a decrease in risk-taking propensity during late flight and post-flight mission phases. Beyond examining group differences, we inspected scores that represented a significant shift from the sample’s mean baseline score, revealing that 11.8% of all flight and post-flight scores were at or below 1.5 standard deviations below the sample’s baseline mean. Finally, exploratory analyses yielded no clear pattern of associations between cognitive performance and either sleep or ratings of alertness. Conclusions: There was no evidence for a systematic decline in cognitive performance for astronauts on a 6-month missions to the ISS. Some differences were observed for specific subtests at specific mission phases, suggesting that processing speed, visual working memory, sustained attention, and risk-taking propensity may be the cognitive domains most susceptible to change in Low Earth Orbit for high performing, professional astronauts. We provide descriptive statistics of pre-flight cognitive performance from 25 astronauts, the largest published preliminary normative database of its kind to date, to help identify significant performance decrements in future samples.

Data curation↗

Anticipating the reaction: public concern about sample return missions

Shifts in public attitude that may affect extraterrestrial sample return include increased public participation in the legal and regulatory environment, institutionalized public vigilance, politicization of technological debates and shifts in the nature of public decision-making, and a risk-averse public accustomed to mass media coverage that focuses on hazards and disasters. The ice-minus recombinant DNA experiment is used as an example of the effects of public opinion on scientific experimentation.

NASA Center ARC↗

Monitoring occupational exposure to cancer chemotherapy drugs

Reports of the health effects of handling cytotoxic drugs and compliance with guidelines for handling these agents are briefly reviewed, and studies using analytical and biological methods of detecting exposure are evaluated. There is little conclusive evidence of detrimental health effects from occupational exposure to cytotoxic drugs. Work practices have improved since the issuance of guidelines for handling these drugs, but compliance with the recommended practices is still inadequate. Of 64 reports published since 1979 on studies of workers' exposure to these drugs, 53 involved studies of changes in cellular or molecular endpoints (biological markers) and 12 described chemical analyses of drugs or their metabolites in urine (2 involved both, and 2 reported the same study). The primary biological markers used were urine mutagenicity, sister chromatid exchange, and chromosomal aberrations; other studies involved formation of micronuclei and measurements of urinary thioethers. The studies had small sample sizes, and the methods were qualitative, nonspecific, subject to many confounders, and possibly not sensitive enough to detect most occupational exposures. Since none of the currently available biological and analytical methods is sufficiently reliable or reproducible for routine monitoring of exposure in the workplace, further studies using these methods are not recommended; efforts should focus instead on wide-spread implementation of improved practices for handling cytotoxic drugs.

Review, Academic↗

Measured Spacecraft Dynamic Effects on Atmospheric Science Instruments

On September 1991, NASA launched the Upper Atmosphere Research Satellite. In addition to its atmospheric science mission, spacecraft dynamic effects on science measurements were analyzed. The investigation included two in-flight experiments to determine how each on-board instrument, subsystem and environmental disturbance contributed to the spacecraft dynamic response and how these disturbances affected science measurements. Three case studies are presented which show the impact of spacecraft dynamic response on science measurements. In the first case, correlation of independent atmospheric meridional wind measurements taken by two instruments with the spacecraft dynamic response demonstrated that excessive vibration (exceeding instrument pointing requirements) resulted in wind measurement disagreement. In the second case, solar array disturbances produced a spacecraft response signature on radiometer measurements. The signature explicitly demonstrated that if an instrument has sufficient spatial and temporal resolution, spacecraft dynamic response could impact measurements. In the final case, correlation of an instrument's fine sun sensor data and CO2 measurements demonstrated the effect of temporal and spatial sampling resolution and active pointing control on science measurements. The sun sensor had a frequency modulated characteristic due to spacecraft vibration and the periodic scanning of another instrument which was not present on the CO2 measurements.

Woodard, Stanley E.↗

Remote sensing of effects of land-use practices on water quality

Research efforts are presented for the use of remote sensing in environmental surveys in Kentucky. Ground truth parameters were established that represent the vegetative cover of disturbed and undisturbed watersheds in the Cumberland Plateau of eastern Kentucky. Several water quality parameters were monitored of the watersheds utilized in the establishment of ground truth data. The capabilities of multistage-multispectral aerial photography and satellite imagery were evaluated in detecting various land use practices. The use of photographic signatures of known land use areas utilizing manually-operated spot densitometers was studied. The correlation of imagery signature data to water quality data was examined. Potential water quality predictions were developed from forested and nonforested watersheds based upon the above correlations. The cost effectiveness of predicting water quality values was evaluated using multistage and satellite imagery sampling techniques.

Graves, D. H.↗

Mapping Weathering and Alteration Minerals in the Comstock and Geiger Grade Areas using Visible to Thermal Infrared Airborne Remote Sensing Data

To support research into both precious metal exploration and environmental site characterization a combination of high spatial/spectral resolution airborne visible, near infrared, short wave infrared (VNIR/SWIR) and thermal infrared (TIR) image data were acquired to remotely map hydrothermal alteration minerals around the Geiger Grade and Comstock alteration regions, and map the mineral by-products of weathered mine dumps in Virginia City. Remote sensing data from the Airborne Visible Infrared Imaging Spectrometer (AVIRIS), SpecTIR Corporation's airborne hyperspectral imager (HyperSpecTIR), the MODIS-ASTER airborne simulator (MASTER), and the Spatially Enhanced Broadband Array Spectrograph System (SEBASS) were acquired and processed into mineral maps based on the unique spectral signatures of image pixels. VNIR/SWIR and TIR field spectrometer data were collected for both calibration and validation of the remote data sets, and field sampling, laboratory spectral analyses and XRD analyses were made to corroborate the surface mineralogy identified by spectroscopy. The resulting mineral maps show the spatial distribution of several important alteration minerals around each study area including alunite, quartz, pyrophyllite, kaolinite, montmorillonite/muscovite, and chlorite. In the Comstock region the mineral maps show acid-sulfate alteration, widespread propylitic alteration and extensive faulting that offsets the acid-sulfate areas, in contrast to the larger, dominantly acid-sulfate alteration exposed along Geiger Grade. Also, different mineral zones within the intense acid-sulfate areas were mapped. In the Virginia City historic mining district the important weathering minerals mapped include hematite, goethite, jarosite and hydrous sulfate minerals (hexahydrite, alunogen and gypsum) located on mine dumps. Sulfate minerals indicate acidic water forming in the mine dump environment. While there is not an immediate threat to the community, there are clearly sources of acidic drainage that were identified remotely.

imaging spectroscopy↗