Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy Management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Using Blockchain Technology, NREL Opens Window to Peer-to-peer Energy Transactions

With its new application, developed in partnership with BlockCypher, NREL has laid the groundwork to help make peer-to-peer energy transactions possible. This technology leans on NREL-developed Foresee, an innovative user-centric home energy management system. NREL’s Dylan Cutler explains the impact this application may one day have on the future of the energy market.

97 MATHEMATICS AND COMPUTING↗

Development of Supervisory Control System for Thermal Energy Distribution System

The integrated energy system (IES) refers to the combination of nuclear energy generation with other energy sources to enable the efficiency and reliability of power generations. To create technologically viable and economically competitive systems, supervisory control strategies are critical for optimizing performance and ensuring stability across different energy generation, transportation, and utilization. This work focuses on the control strategies for the thermal energy distribution system (TEDS), which is a cornerstone of the Dynamic Energy Transport and Integration Laboratory at Idaho National Laboratory. TEDS currently relies on operators to coordinate across different components to manage energy storage and ensure efficiency. This work demonstrates the use of model predictive control (MPC) with surrogate models in determining optimal setpoints for major TEDS components. The capability of MPC-based supervisory control system is evaluated by autonomously matching the power outputs from a Dymola-based TEDS with target heat demands.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Metatranscriptomic insights on gene expression and regulatory controls in Candidatus Accumulibacter phosphatis

Previous studies on enhanced biological phosphorus removal (EBPR) have focused on reconstructing genomic blueprints for the model polyphosphate-accumulating organism Candidatus Accumulibacter phosphatis. Here, a time series metatranscriptome generated from enrichment cultures of Accumulibacter was used to gain insight into anerobic/aerobic metabolism and regulatory mechanisms within an EBPR cycle. Co-expressed gene clusters were identified displaying ecologically relevant trends consistent with batch cycle phases. Transcripts displaying increased abundance during anerobic acetate contact were functionally enriched in energy production and conversion, including upregulation of both cytoplasmic and membrane-bound hydrogenases demonstrating the importance of transcriptional regulation to manage energy and electron flux during anerobic acetate contact. We hypothesized and demonstrated hydrogen production after anerobic acetate contact, a previously unknown strategy for Accumulibacter to maintain redox balance. Genes involved in anerobic glycine utilization were identified and phosphorus release after anerobic glycine contact demonstrated, suggesting that Accumulibacter routes diverse carbon sources to acetyl-CoA formation via previously unrecognized pathways. A comparative genomics analysis of sequences upstream of co-expressed genes identified two statistically significant putative regulatory motifs. One palindromic motif was identified upstream of genes involved in PHA synthesis and acetate activation and is hypothesized to be a phaR binding site, hence representing a hypothetical PHA modulon. A second motif was identified ~35 base pairs (bp) upstream of a large and diverse array of genes and hence may represent a sigma factor binding site. As a result, this analysis provides a basis and framework for further investigations into Accumulibacter metabolism and the reconstruction of regulatory networks in uncultured organisms.

54 ENVIRONMENTAL SCIENCES↗

Modelling of Wastewater Heat Recovery Heat Pump Systems

Wastewater heat recovery is currently an underutilized technology that could be part of solving the climate crisis. A large portion of the heat that leaves a building in the form of wastewater is potentially recoverable for pre-heating domestic hot water or other service water systems. While there are several different approaches to wastewater heat recovery, this project focused on creating detailed, integrated building models for wastewater heat recovery heat pump systems. EnergyPlus models were developed featuring inputs and assumptions corresponding to manufacturers’ specifications, performance lab test data and feedback from engineering consultants. EnergyPlus’s supervisory control Energy Management System objects were heavily relied upon to overcome modelling challenges. The developed EnergyPlus model was integrated into U.S. Department of Energy New Construction Reference Building models for various climate zones and building types to assess potential energy use, energy cost and greenhouse gas emission reductions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar Panels on Hudson County Facilities

This project involved the installation of an 83 kW grid-connected photovoltaic system tied into the energy management system of Hudson County's new 60,000 square foot Emergency Operations and Command Center and staff offices. Other renewable energy features of the building include a 15 kW wind turbine, geothermal heating and cooling, natural daylighting, natural ventilation, gray water plumbing system and a green roof. The County intends to seek Silver LEED certification for the facility.

Photovoltaic↗

The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures: January 2012 - September 2016

This is the complete set of Uniform Methods Project protocols for determining energy efficiency savings for specific measures, all within one report. The report includes the following chapters: Chapter 1: Introduction. Chapter 2: Commercial and Industrial Lighting Evaluation Protocol. Chapter 3: Commercial and Industrial Lighting Controls Evaluation Protocol. Chapter 4: Small Commercial and Residential Unitary and Split System HVAC Cooling Equipment-Efficiency Upgrade Evaluation Protocol. Chapter 5: Residential Furnaces and Boilers Evaluation Protocol. Chapter 6: Residential Lighting Evaluation Protocol. Chapter 7: Refrigerator Recycling Evaluation Protocol. Chapter 8: Whole-Building Retrofit with Consumption Data Analysis Evaluation Protocol. Chapter 9: Metering Cross-Cutting Protocol. Chapter 10: Peak Demand and Time-Differentiated Energy Savings Cross-Cutting Protocol. Chapter 11: Sample Design Cross-Cutting Protocol. Chapter 12: Survey Design and Implementation for Estimating Gross Savings Cross-Cutting Protocol. Chapter 13: Assessing Persistence and Other Evaluation Issues Cross-Cutting Protocol. Chapter 14: Chiller Evaluation Protocol. Chapter 15: Commercial New Construction Evaluation Protocol. Chapter 16: Retrocommissioning Evaluation Protocol. Chapter 17: Residential Behavior Evaluation Protocol. Chapter 18: Variable Frequency Drive Evaluation Protocol. Chapter 19: HVAC Controls (DDC/EMS/BAS) Evaluation Protocol. Chapter 20: Data. Center IT Efficiency Measures Evaluation Protocol. Chapter 21: Estimating Net Savings - Common Practices. Chapter 22: Compressed Air Evaluation Protocol. Chapter 23: Combined Heat and Power Evaluation Protocol. Chapter 24: Strategic Energy Management (SEM) Evaluation Protocol

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Empowering Energy Efficiency in Existing Big-Box Retail/Grocery Stores (Final Optimization Report)

The Center for Sustainable Energy (CSE), in partnership with the National Renewable Energy Laboratory (NREL), TRC Energy Services, P2S Engineering Inc, Walmart, and five innovative technology providers, are to demonstrate the impact of an integrated suite of pre-commercial energy efficiency (EE) technologies in a large, existing, retail building located within an inland disadvantaged community. Proposed technology packages include three categories of advanced EE solutions: heating, ventilating, air-conditioning, and refrigerating (HVAC/R); lighting; and integrated system and building level controls. The project is designed to impact Walmart’s future store specifications, which can be replicated and deployed in other buildings across California with similar end-use and system characteristics. The following lists the technologies considered for this project: DualCool (HVAC evaporative cooling); Software Motor Company (SMC) (HVAC and refrigeration fan motor); I2S: DC LED lighting; LocBit: building energy management and optimization; Saya: water monitoring.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DOE Zero Energy Ready Home Case Study: KB Home — Double ZeroHouse, Lancaster, CA

The home that won a Production Builder award in the 2014 Housing Innovation Awards serves as a model for this builder, showcasing high-tech features including an electric car charging station; a compressed natural gas (CNG) car fueling station; a greywater recycling system that filters shower, sink, and clothes washer water for yard irrigation; smart appliances; and an electronic energy management system.

2014 housing innovation awards↗

Reverse Osmosis Optimization

This technology evaluation was prepared by Pacific Northwest National Laboratory on behalf of the U.S. Department of Energy’s Federal Energy Management Program (FEMP). The technology evaluation assesses techniques for optimizing reverse osmosis (RO) systems to increase RO system performance and water efficiency. This evaluation provides a general description of RO systems, the influence of RO systems on water use, and key areas where RO systems can be optimized to reduce water and energy consumption. The evaluation is intended to help facility managers at Federal sites understand the basic concepts of the RO process and system optimization options, enabling them to make informed decisions during the system design process for either new projects or recommissioning of existing equipment. This evaluation is focused on commercial-sized RO systems generally treating more than 80 gallons per hour.

McMordie Stoughton, Kate L.↗

Reverse Osmosis Optimization

This technology evaluation was prepared by Pacific Northwest National Laboratory on behalf of the U.S. Department of Energy’s Federal Energy Management Program (FEMP). The technology evaluation assesses techniques for optimizing reverse osmosis (RO) systems to increase RO system performance and water efficiency. This evaluation provides a general description of RO systems, the influence of RO systems on water use, and key areas where RO systems can be optimized to reduce water and energy consumption. The evaluation is intended to help facility managers at Federal sites understand the basic concepts of the RO process and system optimization options, enabling them to make informed decisions during the system design process for either new projects or recommissioning of existing equipment. This evaluation is focused on commercial-sized RO systems generally treating more than 80 gallons per hour.

osmosis, optimization↗

Spent Nuclear Fuel Exploratory Roadmaps - 20054

The U.S. Department of Energy manages nearly 2,500 metric tons of heavy metal (MTHM) of spent nuclear fuel (SNF) resulting from several decades of research, testing, and production reactors [DOE 1995]. This SNF is managed at the DOE Hanford Site in Washington State (Hanford), Idaho National Laboratory (INL), and Savannah River Site in South Carolina (SRS). From 1995 to 2004, the Department of Energy (DOE) made several key programmatic decisions, supported by appropriate documentation in accordance with the National Environmental Policy Act (NEPA) for the management of SNF [DOE 1995]. These decisions have provided an overarching framework for SNF management, as well as site-specific and SNF-related management decisions for the past two decades. In the years since these decisions were made, with the notable exception of the successful drying and packaging of the production reactor fuel at Hanford, a majority of the decisions have been largely unimplemented. Also, since these decisions were made, a number of changes that bear on considerations relative to the path forward have occurred. A SNF Exploratory Road map activity, identified reasonable alternate pathways for DoE's inventory of SNF. Three fundamental pathways were identified in this activity for the long-term management and disposition of DOE SNF: Direct Disposal Pathway, Existing Processing Pathway and Alternate Processing Pathway. Further actions would be required (e.g., evaluation of NEPA analysis, technology maturity evaluations, refinement of cost and risks, benefits and advantages relative to other alternate paths) to define and inform many key decisions that will result in the selection of the disposition pathways that are most beneficial to the US Government in dispositioning DoE's SNF inventory. DOE is currently managing all SNF safely; however, the age of DOE-owned SNF and facilities for storing and processing SNF, coupled with the uncertainty of the storage duration, necessitates decisions and actions to ensure that the infrastructure will be in place to ensure continued safe and effective long-term management and eventual disposal. The identification of reasonable alternate pathways took these considerations into account in an effort to proactively manage conditions that could challenge the safety of storing and managing DOE SNF over the time periods now contemplated and also to ensure that flexibility is preserved to ensure that the DOE SNF remains compatible with final disposition pathways when they become available. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

2018 Energy Storage Pricing Survey

Since grid energy storage is still a nascent industry, it is often difficult to obtain capital costs for various energy storage technologies. This type of information is required to perform an initial cost-benefit analysis related to a potential energy storage deployment, as well as to compare different energy storage technology options. The goal of this report is to summarize energy storage capital costs that were obtained from industry pricing surveys. The methodology breaks down the cost of an energy storage system into the following categories: the storage module; the balance of system; the power conversion system; the energy management system; and the engineering, procurement, and construction costs. Pricing data is presented for the following technologies: pumped hydro storage; compressed air energy storage; sodium battery storage; zinc battery storage; long duration flywheels; short duration flywheels; vanadium flow batteries; zinc bromide flow batteries; iron flow batteries; nickel batteries; lithium ion energy batteries; lithium ion power batteries; lead acid batteries; and advanced lead carbon batteries.

25 ENERGY STORAGE↗

Energy - A systems problem

Energy management in its most comprehensive sense encompasses economic, technical, environmental, and political problems. The present evaluation of prospects notes that opportunities for energy conservation are widespread, in such fields as building air conditioning, transportation, electrical appliances, and industrial processes. Further conservation is expected to be achieved through a combination of technology development and economics; the latter factor must not be unduly influenced by political measures that shield consumers from the true cost of energy.

Bourke, Roger D.↗

Factors Influencing the Decisions and Actions of Pilots and Air Traffic Controllers in Three Plausible NextGen Environments

In the current air traffic management (ATM) system, pilots and air traffic controllers have well-established roles and responsibilities: pilots fly aircraft and are concerned with energy management, fuel efficiency, and passenger comfort; controllers separate aircraft and are concerned with safety and management of traffic flows. Despite having different goals and obligations, both groups must be able to effectively communicate and interact with each other for the ATM system to work. This interaction will become even more challenging as traffic volume increases dramatically in the near future. To accommodate this increase, by 2025 the national air transportation system in the U.S. will go through a transformation that will modernize the ATM system and make it safer, more effective, and more efficient. This new system, NextGen, will change how pilots and controllers perform their tasks by incorporating advanced technologies and employing new procedures. It will also distribute responsibility between pilots, controllers and automation over such tasks as maintaining aircraft separation. The present chapter describes three plausible concepts of operations that allocate different ATM responsibilities to these groups. We describe how each concept changes the role of each operator and the types of decisions and actions performed by them.

Vu, Kim-Phuong L.↗

Ground-source Heat Pumps Applied to Commercial Buildings

Ground-source heat pumps can provide an energy-efficient, cost-effective way to heat and cool commercial facilities. While ground-source heat pumps are well established in the residential sector, their application in larger, commercial-style, facilities is lagging, in part because of a lack of experience with the technology by those in decision-making positions. Through the use of a ground-coupling system, a conventional water-source heat pump design is transformed to a unique means of utilizing thermodynamic properties of earth and groundwater for efficient operation throughout the year in most climates. In essence, the ground (or groundwater) serves as a heat source during winter operation and a heat sink for summer cooling. Many varieties in design are available, so the technology can be adapted to almost any site. Ground-source heat pump systems can be used widely in commercial-building applications and, with proper installation, offer great potential for the commercial sector, where increased efficiency and reduced heating and cooling costs are important. Ground-source heat pump systems require less refrigerant than conventional air-source heat pumps or air-conditioning systems, with the exception of direct-expansion-type ground-source heat pump systems. This chapter provides information and procedures that an energy manager can use to evaluate most ground-source heat pump applications. Ground-source heat pump operation, system types, design variations, energy savings, and other benefits are explained. Guidelines are provided for appropriate application and installation. Two case studies are presented to give the reader a sense of the actual costs and energy savings. A list of manufacturers and references for further reading are included for prospective users who have specific or highly technical questions not fully addressed in this chapter. Sample case spreadsheets are provided in Appendix A. Additional appendixes provide other information on the ground-source heat pump technology.

15 GEOTHERMAL ENERGY↗

Wide-Area Energy Storage and Management system to Balance Intermittent Resources in the Bonneville Power Administration and California ISO Control Areas

The entire project addresses the issue of mitigating additional intermittency and fast ramps that occur at higher penetration of intermittent resources, including wind genera-tion, in the Bonneville Power Administration (BPA) and the California Independent Sys-tem Operator (California ISO) control areas. The proposed Wide Area Energy Storage and Management System (WAEMS) will address the additional regulation requirement through the energy exchange between the participating control areas and through the use of energy storage and other generation resources. For the BPA and California ISO control centers, the new regulation service will look no different comparing with the traditional regulation resources. The proposed project will benefit the regulation service in these service areas, regardless of the actual degree of penetration of the intermittent resources in the regions. The project develops principles, algorithms, market integration rules, functional de-sign and technical specifications for the WAEMS system. The project is sponsored by BPA and supported in kind by California ISO, Beacon Power Corporation, and the Cali-fornia Energy Commission (CEC).

25 ENERGY STORAGE↗

Efficiency and Demand Flexibility in Large Office Buildings: The Potential for Cost Savings and CO 2 Reductions from Lighting and Cooling Measures

This report presents the estimated impact of lighting and cooling efficiency and demand flexibility measures in large office buildings in each state in the contiguous United States. It provides modeled results for three different metrics: bill savings, regional grid operational costs savings, and carbon dioxide (CO 2 ) emissions reductions. Lighting efficiency and demand flexibility are estimated to reduce load by up to 80 MWh/yr in a single large office building. These load reductions result in customer bill savings of up to $8,800/yr per building, with the highest savings in southern and midwestern states. Grid operating cost savings are estimated at up to $3,240/yr/building, with greatest benefit in southern and northeastern states. CO 2 emissions reduction potential is highest in the Dakotas, Nebraska, across the Midwest, in West Virginia, and in Mississippi (<48,200 kg/yr/building). Comparatively, cooling measures are found to have less load reduction potential (<28.5 MWh/yr/building), with the greatest potential in southern states including Texas, which ranks top of the list across several of the metrics studied. In numerous states, shifting cooling load to off-peak hours is found to increase costs and CO 2 emissions because precooling results in increased load during high-cost or high-CO 2 emissions periods. In general, focusing on cooling efficiency and load shedding has the potential for more savings. In all cases, the specific rate structure is a significant determinant in actual bill savings, which are up to $4,000/yr/building. To realize the full potential for bill savings through an energy measure, building operators must identify how the measure will change the building load pattern and the interaction of this load change with the applicable rate tariff. To realize CO 2 emissions reductions, industry and state coordination is needed to verify which fuel source is on the margin and then to create incentives for end users to reduce load during high-CO 2 emissions hours. Regular updates to data sets and analyses are critical. Regulators and policymakers are well positioned to facilitate the necessary coordination between the electric industry and building energy managers to develop appropriate price signals and incentives.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Final Technical Report

Executive Summary The document contains Final Technical Report on the Industrial Assessment Center Program at Loyola Marymount University in Los Angeles, covering the contract period of 9/1/2002 to 11/30/2006, under the contract DE-FC36-02GO 12073. The Report describes six required program tasks, as follows: TASK 1 is a summary of the assessments performed over the life of the award: 77 assessments were performed, 595 AR were recommended, covering a very broad range of manufacturing plants. TASK 2 is a description of the efforts to promote and increase the adoption of assessment recommendations and employ innovative methods to assist in accomplishing these goals. The LMU IAC has been very successful in accomplishing the program goals, including implemented savings of $5,141,895 in energy, $10,045,411 in productivity and $30,719 in waste, for a total of $15,218,025. This represents 44% of the recommended savings of $34,896,392. TASK 3 is a description of the efforts promoting the IAC Program and enhancing recruitment efforts for new clients and expanded geographic coverage. LMU IAC has been very successful recruiting new clients covering Southern California. Every year, the intended number of clients was recruited. TASK 4 describes the educational opportunities, training, and other related activities for IAC students. A total of 38 students graduated from the program, including 2-3 graduate students every semester, and the remainder undergraduate students, mostly from the Mechanical Engineering Department. The students received formal weekly training in energy (75%) and productivity (25). All students underwent extensive safety training. All students praised the IAC experience very highly. TASK 5 describes the coordination and integration of the Center activities with other Center and IAC Program activities, and DOE programs. LMU IAC worked closely with MIT, and SDSU IAC and SFSU IAC, and enthusiastically supported the SEN activities. TASK 6 describes other tasks and accomplishments. During the award period, Assistant Director Rudy Marloth became a DOE Qualified Specialist in PHAST, a DOE Qualified Specialist in Compressed Air, and a Certified Energy Manager, and earned a MS degree in Environmental Science.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗