Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electrical Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Introduction to the Minitrack on Monitoring, Control, and Protection.

This minitrack is on topics related to the monitoring, control, and protection of electric power systems for real-time operations and short-term operations planning. This year the emphasis has been on recent developments in the area of large-scale dynamic research for power systems and on hybrid and distributed control concepts for decentralized command and control of existing critical energy infrastructures.

Eto, Joseph H↗

Electrical meter probe contact verification system

A system and method verifies continuity with and measures voltage across a circuit under test (in some instances simultaneously) using two or more test probes. Two or more probe continuity circuits measure continuity through the test probes by injecting a test current through and measuring a processed test current received at each of the plurality of test probes. The probe continuity circuits measure the respective processed test current rendered by the test current flowing through the test circuit at each test probe. A voltmeter measures the potential difference across the test probes.

42 ENGINEERING↗

Fault Response of Distributed Energy Resources Considering the Requirements of IEEE 1547-2018

Inverter-based DER responses to faults on the electric power system are different than those of conventional generators and are often poorly understood. Inverter fault responses are largely software-defined, within physics-based constraints. DERs are regulated by standards and grid codes that also constrain their responses. Though fault response of DERs will vary widely, for any DER following any particular standard, a pattern of fault response can be synthesized by observing that particular standard. In this paper, the recently published IEEE 1547-2018 is examined to explore the general fault response of any DER that follows IEEE 1547-2018. Additionally, an IEEE 1547-2018 compliant inverter model is developed and tested in simulation to find the fault response, and that response is compared with the fault response of a commercial off-the-shelf inverter.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Providing Ancillary Services with Photovoltaic Generation in Multi-Timescale Grid Operation: Preprint

With photovoltaic (PV) generation substantially increases, electric power systems need more flexible resources that can provide ancillary services to mitigate the variability and uncertainty of the PV generation. On the one hand, the increase of PV generation necessitates the needs of more flexible resources. On the other hand, PV generation, because of its low operation cost, has been replacing the conventional generation in the system which is the main flexible resources in the current system. Consequently, there is a trend to require the renewable generation including PV to provide flexible ancillary services to further accommodate more PV integration. This paper proposes a multi-timescale grid operation model considering the various control strategies of PV providing different ancillary services. Numerical case studies demonstrate that with PV providing both regulation reserve and primary frequency reserve, the system operating costs and PV curtailment will be reduced significantly. It shows that not only the system reliability but also PV's profitability can be improved with PV providing more ancillary services.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Cybersecurity Guide for Distributed Wind Presentation

This presentation communicates information about the MIRACL project Resilience Metrics report and Resilience Framework report. It was created for the 2021 MIRACL advisory board meeting. Distributed wind sits at the intersection of grid-connected, off-grid and behind-the-meter cyber-physical electrical energy systems. The unique physical properties and communications requirements for distributed wind systems mean that there are unique cybersecurity considerations, but there is little to no existing guidance on best practices for cybersecurity. This presentation is intended to be a starting point for distributed wind stakeholders including manufacturers, installers and integrators, and operators (facility, aggregator, or utility). A holistic threat perspective is used to describe the adversaries, threats, and potential impacts of cyberattacks, with special emphasis on what sets distributed wind systems apart from other distributed energy resources (DER). We present the recommendations for cybersecurity, both in terms of needs of the system and roles that specific stakeholders should fulfill. Distributed wind systems can come in a variety of architectures and applications, so there is no one-size-fits-all approach to cybersecurity. However, this document contains the relevant information for stakeholders to identify the cybersecurity needs of their system, refer to relevant standards, and apply best practices in a manner most consistent with their security and operational goals.

17 WIND ENERGY↗

Electric Vehicle Basics

Electric vehicles (EVs) use electricity as their primary fuel or to improve the efficiency of conventional vehicle designs. EVs include all-electric vehicles, also referred to as battery electric vehicles (BEVs), and plug-in hybrid electric vehicles (PHEVs). In colloquial references, these vehicles are called electric cars, or simply EVs, even though some of these vehicles still use liquid fuels in conjunction with electricity. EVs are known for providing instant torque and a quiet driver experience. Other types of electric-drive vehicles not covered here include hybrid electric vehicles, which are powered by a conventional engine and an electric motor that uses energy stored in a battery, and fuel cell electric vehicles, which use a propulsion system similar to electric vehicles, where energy stored as hydrogen is converted to electricity by the fuel cell.

47 OTHER INSTRUMENTATION↗

Fourier Analysis Method for Wireless Power Transfer Coil Design

Wireless power transfer (WPT) systems for Electric Vehicles (EVs) are designed to meet specifications such as stray field, power transfer, efficiency, and ground clearance. Typical design approaches include iterative analysis of predetermined coil geometries to identify candidates that meet these constraints. This work instead directly generates WPT coil shapes and magnetic fields to meet specifications and constraints through the optimization of Fourier basis function coefficients. The proposed Fourier Analysis Method (FAM) applies to arbitrary planar coil geometries and does not rely on iterative finite-element analysis (FEA) simulations. This flexibility allows for rapid design evaluation across a larger range of coil geometries and design specifications. A prototype coil is built to compare FAM outputs to experimental measurements and FEA simulations. The FAM is then used to illustrate the tradeoff of coil current and stray field for a given power level showing that the method is capable of generating optimized coil shapes to meet arbitrary field constraints.

Foote, Andrew↗

Metallization of conductive wires for solar cells

Methods of fabricating a solar cell, and system for electrically coupling solar cells, are described. In an example, the methods for fabricating a solar cell can include placing conductive wires in a wire guide, where conductive wires are placed over a first semiconductor substrate having first doped regions and second doped regions. The method can include aligning the conductive wires over the first and second doped regions, where the wire guide aligns the conductive wires substantially parallel to the first and second doped regions. The method can include bonding the conductive wires to the first and second doped regions. The bonding can include applying a mechanical force to the semiconductor substrate via a roller or bonding head of the wire guide, where the wire guide inhibits lateral movement of the conductive wires during the bonding.

Sewell, Richard Hamilton↗

Transformative remedial action scheme tool (TRAST)

Techniques and apparatuses are described that enable transformative Remedial Action Scheme (RAS) analyses and methodologies for a bulk electric power system, including methods of designing, reviewing, revising, testing, implementing, verifying, or validating a RAS. An improved RAS improves operation of the power system, including performance, reliability, control, and asset utilization. The example methodologies discussed—also referred to as a transformative Remedial Action Scheme tool (TRAST)—provide an end-to-end solution for adaptively setting RAS parameters based on realistic and near real-time operation conditions to improve power grid reliability and grid asset utilization, by leveraging utility data analysis and employing dynamic simulations and machine learning to significantly simplify and shorten the entire RAS process.

Fan, Xiaoyuan↗

All Hazards Approach to Grid Modernization

Resilience hazards for electric power systems are on the rise, exacerbated by both a rise in extreme weather events and manmade physical and cyber attacks. At the same time, grid modernization challenges plague the United States, covering everything from increased electrification and ambitious renewable energy targets to aging infrastructure and regulation that lags behind today’s challenges. This talk will cover an all-hazards risk based approach that addresses both rising resilience and grid modernization challenges. Examples of this approach taken for national laboratory research projects will be discussed, including a deep dive into a project that addressed black start, resynchronization, distributed control, and cybersecurity challenges for an operational microgrid up to sub-transmission voltages. As takeaways from this project are translated from demonstration scale to real-world exercises, key lessons are noted on the translation from research into practice and how this can inform risk-based research moving forward

17 WIND ENERGY↗

Robust and cybersecure coordinated unintentional island detection for microgrids

Unintentional islanding (UI) of a circuit of distributed energy resources (DERs) may leave area electrical power systems (EPS), external to the DER circuit, energized. Thus, UI detection methods have been developed to detect unintentional islanding and trigger a UI response. However, individual UI detection methods have various deficiencies. Thus, a consensus-based UI detection process is disclosed that builds a consensus from multiple UI detection sources, optionally implementing different UI detection methods. The redundancy in this consensus-based UI detection process provides robust, sensitive, selective, and cybersecure UI detection for the entire DER circuit. For example, the consensus-based UI detection process may eliminate or reduce non-detection zones, avoid false positives, thwart cyber-attacks, and/or the like.

Brissette, Alex↗

Cyber-Enabled Sabotage, Critical Function Assurance, and Cyber-Informed Engineering

Cyber-enabled Sabotage, Critical Function Assurance, and Cyber-Informed Engineering: This discussion will introduce the idea of cyber-enabled sabotage, and the role engineering plays in the cyber defense of critical functions with a focus on electric power systems. It will outline how and why engineering practice must be used to apply cybersecurity principles to establish safe and reliable operations even in the face of determined and skilled adversaries, and give an overview of INL’s Consequence-Driven Cyber-Informed Engineering methodology to apply these principles. There will be an opportunity for audience questions and answers at the end of the session.

42 ENGINEERING↗

ChargeX KPIs Transition to SAE

To systematically improve the public charging experience, EV charging industry stakeholders need to define and measure it precisely. Many stakeholders currently measure aspects of the charging experience, but they typically employ metrics that are either operational in nature, such as charger uptime and mean time between failures, or composite customer satisfaction indices. To improve the customer experience most effectively, the industry needs metrics that define the charging experience from the perspective of the customer, not business operations. Furthermore, industry practitioners need granular metrics to know what specific aspects of the charging experience need improvement. This presentation gives an overview of the key performance indicators (KPIs) defined by the ChargeX Consortium.

33 ADVANCED PROPULSION SYSTEMS↗

Assessing the Economic Value of Underground Thermal Storage for Hybrid Geothermal Power

Solutions are needed to address resource adequacy in the electric power system for highly decarbonized systems. The storage duration, the length of time a storage device can provide continuous output at its rated capacity, must be sufficient to receive full credit toward resource adequacy. Longer peaks and high fractions of variable renewable generation have increased the required duration to potentially seasonal durations. Underground Thermal Energy Storage (UTES) can be adapted to a hybrid storage power plant or heating and cooling applications to satisfy the need for long-duration storage. In this study, we use the Renewable Energy Deployment System (ReEDS) capacity expansion model to evaluate the increase in value for an enhanced geothermal system (EGS) resources by adding UTES. In modeled scenarios, using geothermal without storage as a baseline we compare the increase in economic value for plants with a range of storage characteristics. The added value of a hybrid storage plant changes depending on assumptions including the length of storage duration, efficiency, and ability to charge storage from the grid during periods of low energy prices. Relating proposed characteristics for geothermal UTES hybrids to the modeled economic value provides insight into economically viable costs for developing UTES as well as what combination of technology characteristics and future energy and policy assumptions drive significant value increases.

capacity expansion model↗

A Review on Protection Challenges of Transmission Lines Connected to Inverter-Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses

14 SOLAR ENERGY↗