Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Measurement of the liquid argon scintillation pulse shape using differentiable simulation in the coherent CAPTAIN-Mills experiment

The coherent CAPTAIN-Mills (CCM) experiment is a liquid argon (LAr) light collection detector searching for MeV-scale neutrino and beyond Standard Model physics signatures. Two hundred eight-inch photomultiplier tubes instrument the seven-ton fiducial volume with 50% photocathode coverage to detect light produced by charged particles. CCM’s light-based approach reduces requirements of LAr purity, compared to other detection technologies, such that sub-MeV particles can be reliably detected without additional LAr filtration and with 𝒪⁡(1) parts per million of common contaminants. We present a measurement of LAr light production and propagation parameters, with uncertainties, obtained from a sample of MeV-scale electromagnetic events. The optimization of this high-dimensional parameter space was facilitated by a differentiable optical photon Monte Carlo simulation and detailed photomultiplier tube response characterization. This result accurately predicts the timing and spatial distribution of light due to scintillation and Cherenkov emission in the detector. This is the first description of photon propagation in LAr to include several effects, including anomalous dispersion of the index of refraction near the ultraviolet resonance, Mie scattering from impurities, and Cherenkov light production.

Cherenkov detectors↗

Compton scattering from the deuteron above pion-production threshold

The electromagnetic polarizabilities of the nucleon are fundamental nucleon-structure observables that characterize its response to external electromagnetic fields. The neutron polarizabilities can be accessed from Compton-scattering data on light nuclear targets. Recent measurements of the differential cross section for Compton scattering on the deuteron below the pion-production threshold have decreased the uncertainties in the neutron polarizabilities, yet the proton polarizabilities remain known substantially more accurately. Here, as the sensitivity of the cross section to the polarizabilities increases with incident photon energy, measurements above the pion threshold may offer a way for an improved determination of the neutron polarizabilities. In this work, the first measurement of the cross section for Compton scattering on the deuteron above the pion-production threshold is presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New capabilities in high-resolution neutron Larmor diffraction at ORNL

Using superconducting magnetic Wollaston prisms, high-resolution neutron Larmor diffraction has been implemented at the High-Flux Isotope Reactor of Oak Ridge National Laboratory (ORNL), Tennesse, USA. This technique allows the inverse relationship between the achievable diffraction resolution and the usable neutron flux to be overcome. Instead of employing physically tilted radio-frequency spin flippers, the method uses magnetic Wollaston prisms which are electromagnetically tuned by changing the field configurations in the device. As implemented, this method can be used to measure lattice-spacing changes induced, for example, by thermal expansion or strain with a resolution of Δd/d ≃ 10 –6 , and the splitting of sharp Bragg peaks with a resolution of Δd/d = 3 × 10 –4 . The resolution for discerning a change in the profile of a Bragg peak is Δd/d < 10 –5 . This is a remarkable degree of precision for a neutron diffractometer as compact as the one used in this implementation. Higher precision could be obtained by implementing this technique in an instrument with a larger footprint. In conclusion, the availability of this technique will provide an alternative when standard neutron diffraction methods fail and will greatly benefit the scientific communities that require high-resolution diffraction measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Validation of the EDGES Low-band Antenna Beam Model

The response of the antenna is a source of uncertainty in measurements with the Experiment to Detect the Global Epoch of Reionization Signature (EDGES). We aim to validate the electromagnetic beam model of the low-band (50–100 MHz) dipole antenna with comparisons between models and against data. We find that simulations of a simplified model of the antenna over an infinite perfectly conducting ground plane are, with one exception, robust to changes in the numerical electromagnetic solver code or algorithm. For simulations of the antenna with the actual finite ground plane and realistic soil properties, we find that two out of three numerical solvers agree well. Applying our analysis pipeline to a simulated drift-scan observation from an early EDGES low-band instrument that had a 10 m × 10 m ground plane, we find residual levels after fitting and removing a five-term foreground model from the simulated data binned in local sidereal time (LST) average about 250 mK with ±40 mK variation between numerical solvers. A similar analysis of the primary 30 m × 30 m sawtooth ground plane reduced the LST-averaged residuals to about 90 mK with ±10 mK between the two viable solvers. More broadly we show that larger ground planes generally perform better than smaller ground planes. Simulated data have a power that is within 4% of real observations, a limitation of net accuracy of the sky and beam models. We observe that residual spectral structures after foreground model fits match qualitatively between simulated data and observations, suggesting that the frequency dependence of the beam is reasonably represented by the models. We find that a soil conductivity of 0.02 S m{sup -1} and relative permittivity of 3.5 yield good agreement between simulated spectra and observations. This is consistent with the soil properties reported by Sutinjo et al. for the Murchison Radio-astronomy Observatory, where EDGES is located.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analytical scanning evanescent microwave microscope and control stage

A scanning evanescent microwave microscope (SEMM) that uses near-field evanescent electromagnetic waves to probe sample properties is disclosed. The SEMM is capable of high resolution imaging and quantitative measurements of the electrical properties of the sample. The SEMM has the ability to map dielectric constant, loss tangent, conductivity, electrical impedance, and other electrical parameters of materials. Such properties are then used to provide distance control over a wide range, from to microns to nanometers, over dielectric and conductive samples for a scanned evanescent microwave probe, which enable quantitative non-contact and submicron spatial resolution topographic and electrical impedance profiling of dielectric, nonlinear dielectric and conductive materials. The invention also allows quantitative estimation of microwave impedance using signals obtained by the scanned evanescent microwave probe and quasistatic approximation modeling. The SEMM can be used to measure electrical properties of both dielectric and electrically conducting materials.

47 OTHER INSTRUMENTATION↗

Precise Measurement of the Neutron Magnetic Form Factor G{sub M}{sup n} in the Few-GeV{sup 2} Region

The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q{sup 2}=1.0-4.8 GeV{sup 2} with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CORONAL FUZZINESS MODELED WITH PULSE-HEATED MULTI-STRANDED LOOP SYSTEMS

Coronal active regions are observed to get increasingly fuzzy (i.e., increasingly confused and uniform) in increasingly hard energy bands or lines. We explain this as evidence of fine multi-temperature structure of coronal loops. To this end, we model bundles of loops made of thin strands, each heated by short and intense heat pulses. For simplicity, we assume that the heat pulses are all equal and triggered only once in each strand at a random time. The pulse intensity and cadence are selected so as to have steady active region loops ({approx}3 MK) on average. We compute the evolution of the confined heated plasma with a hydrodynamic loop model. We then compute the emission along each strand in several spectral lines, from cool ({<=}1 MK), to warm (2-3 MK) lines, detectable with Hinode/Extreme-ultraviolet Imaging Spectrometer, to hot X-ray lines. The strands are then put side by side to construct an active region loop bundle. We find that in the warm lines (2-3 MK) the loop emission fills all the available image surface. Therefore, the emission appears quite uniform and it is difficult to resolve the single loops, while in the cool lines the loops are considerably more contrasted and the region is less fuzzy. The main reasons for this effect are that, during their evolution, i.e., pulse heating and slow cooling, each strand spends a relatively long time at temperatures around 2-3 MK and it has a high emission measure during that phase, so the whole region appears more uniform or smudged. We predict that fuzziness should be reduced in the hot UV and X-ray lines.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-J-146: Experimental Validation of 6 MV Photon PDD in Parallel Magnetic Field Calculated by EGSnrc

Purpose: Integrated linac-MR systems are uniquely suited for real time tumor tracking during radiation treatment. Understanding the magnetic field dose effects and incorporating them in treatment planning is paramount for linac-MR clinical implementation. We experimentally validated the EGSnrc dose calculations in the presence of a magnetic field parallel to the radiation beam travel. Methods: Two cylindrical bore electromagnets produced a 0.21 T magnetic field parallel to the central axis of a 6 MV photon beam. A parallel plate ion chamber was used to measure the PDD in a polystyrene phantom, placed inside the bore in two setups: phantom top surface coinciding with the magnet bore center (183 cm SSD), and with the magnet bore’s top surface (170 cm SSD). We measured the field of the magnet at several points and included the exact dimensions of the coils to generate a 3D magnetic field map in a finite element model. BEAMnrc and DOSXYZnrc simulated the PDD experiments in parallel magnetic field (i.e. 3D magnetic field included) and with no magnetic field. Results: With the phantom surface at the top of the electromagnet, the surface dose increased by 10% (compared to no-magnetic field), due to electrons being focused by the smaller fringe fields of the electromagnet. With the phantom surface at the bore center, the surface dose increased by 30% since extra 13 cm of air column was in relatively higher magnetic field (>0.13T) in the magnet bore. EGSnrc Monte Carlo code correctly calculated the radiation dose with and without the magnetic field, and all points passed the 2%, 2 mm Gamma criterion when the ion chamber’s entrance window and air cavity were included in the simulated phantom. Conclusion: A parallel magnetic field increases the surface and buildup dose during irradiation. The EGSnrc package can model these magnetic field dose effects accurately. Dr. Fallone is a co-founder and CEO of MagnetTx Oncology Solutions (under discussions to license Alberta bi-planar linac MR for commercialization).

60 APPLIED LIFE SCIENCES↗

EVIDENCE FOR GAMMA-RAY HALOS AROUND ACTIVE GALACTIC NUCLEI AND THE FIRST MEASUREMENT OF INTERGALACTIC MAGNETIC FIELDS

Intergalactic magnetic fields (IGMFs) can cause the appearance of halos around the gamma-ray images of distant objects because an electromagnetic cascade initiated by a high-energy gamma-ray interaction with the photon background is broadened by magnetic deflections. We report evidence of such gamma-ray halos in the stacked images of the 170 brightest active galactic nuclei (AGNs) in the 11 month source catalog of the Fermi Gamma-Ray Space Telescope. Excess over the point-spread function in the surface brightness profile is statistically significant at 3.5{sigma} (99.95% confidence level), for the nearby, hard population of AGNs. The halo size and brightness are consistent with IGMF, B {sub IGMF} {approx} 10{sup -15} G. The knowledge of IGMF will facilitate the future gamma-ray and charged-particle astronomy. Furthermore, since IGMFs are likely to originate from the primordial seed fields created shortly after the big bang, this potentially opens a new window on the origin of cosmological magnetic fields, inflation, and the phase transitions in the early universe.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance and Molière radius measurements using a compact prototype of LumiCal in an electron test beam

A new design of a detector plane of sub-millimetre thickness for an electromagnetic sampling calorimeter is presented. It is intended to be used in the luminometers LumiCal and BeamCal in future linear e \(^{+}\) e \(^{-}\) collider experiments. The detector planes were produced utilising novel connectivity scheme technologies. They were installed in a compact prototype of the calorimeter and tested at DESY with an electron beam of energy 1–5 GeV. The performance of a prototype of a compact LumiCal comprising eight detector planes was studied. The effective Molière radius at 5 GeV was determined to be (8.1 ± 0.1 (stat) ± 0.3 (syst)) mm, a value well reproduced by the Monte Carlo (MC) simulation (8.4 ± 0.1) mm. The dependence of the effective Molière radius on the electron energy in the range 1–5 GeV was also studied. Good agreement was obtained between data and MC simulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Studies of the Electromagnetic Structure of Mesons at Jefferson Lab

The Jefferson Laboratory Hall B PrimEx Collaboration is using tagged photons to perform an absolute 1.4% level cross section measurement of the photoproduction of neutral pions in the Coulomb field of a nucleus. The absolute cross section for this process is directly proportional to the neutral pion radiative decay width and consequently the uncertainty in the luminosity is directly reflected in the final error bar of the measurement. The PI has taken primary responsibility for the photon flux determination and in this technical report, we outline the steps taken to limit the uncertainty in the tagged photon flux to the 1% level. These include the use of a total absorption counter for absolute flux calibration, a pair spectrometer for online relative flux monitoring, and updated procedures for postbremsstrahlung electron counting. The photon tagging technique has been used routinely in its various forms to provide quasimonochromatic photons for absolute photonuclear cross section measurements. The analysis of such experiments in the context of bremsstrahlung photon tagging was summarized by Owens in 1990. Since then, a number of developments have made possible significant improvements in the implementation of this technique. Here, we describe the steps taken by the PrimEx Collaboration in Hall B of Jefferson Laboratory to limit the systematic uncertainty in the absolute photon flux to 1%. They include an absolute flux calibration at low intensity with a total absorption counter, online relative flux monitoring with a pair spectrometer, and the use of multihit time to digital converters for post bremsstrahlung electron counting during production data runs. While this discussion focuses on the analysis techniques utilized by the PrimEx Collaboration which involves a bremsstrahlung based photon tagging system to measure the neutral pion lifetime, the methods described herein readily apply to other types of photon tagging systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration and Localization of Optically Pumped Magnetometers Using Electromagnetic Coils

In this paper, we propose a method to estimate the position, orientation, and gain of a magnetic field sensor using a set of (large) electromagnetic coils. We apply the method for calibrating an array of optically pumped magnetometers (OPMs) for magnetoencephalography (MEG). We first measure the magnetic fields of the coils at multiple known positions using a well-calibrated triaxial magnetometer, and model these discreetly sampled fields using vector spherical harmonics (VSH) functions. We then localize and calibrate an OPM by minimizing the sum of squared errors between the model signals and the OPM responses to the coil fields. We show that by using homogeneous and first-order gradient fields, the OPM sensor parameters (gain, position, and orientation) can be obtained from a set of linear equations with pseudo-inverses of two matrices. The currents that should be applied to the coils for approximating these low-order field components can be determined based on the VSH models. Computationally simple initial estimates of the OPM sensor parameters follow. As a first test of the method, we placed a fluxgate magnetometer at multiple positions and estimated the RMS position, orientation, and gain errors of the method to be 1.0 mm, 0.2°, and 0.8%, respectively. Lastly, we calibrated a 48-channel OPM array. The accuracy of the OPM calibration was tested by using the OPM array to localize magnetic dipoles in a phantom, which resulted in an average dipole position error of 3.3 mm. The results demonstrate the feasibility of using electromagnetic coils to calibrate and localize OPMs for MEG.

47 OTHER INSTRUMENTATION↗

Challenges for the statistical gravitational-wave method to measure the Hubble constant

Gravitational waves (GW) can be employed as standard sirens that will soon measure the Hubble constant with sufficient precision to weigh in on the ~5σ Hubble tension. Most GW sources will have no identified electromagnetic counterpart, leading to uncertainty in the redshift of the source, and in turn a degeneracy between host galaxy distance, redshift, and H 0 . In the case where no electromagnetic counterparts are identified, it has been proposed that a statistical canvassing of candidate GW hosts, found in a large galaxy survey for example, can be used to accurately constrain the Hubble constant. We study and simulate this "galaxy voting" method to compute H 0 . Here, we find that the Hubble constant posterior is in general biased relative to the true value even when making optimistic assumptions about the statistical properties of the sample. Using the MICECAT light-cone catalog, we find that the bias in the H0 posteriors depends on the realization of the underlying galaxy sample and the precision of the GW source distance measurement.

79 ASTRONOMY AND ASTROPHYSICS↗

Electromagnetic Analysis of ITER Electron Cyclotron Emission Components and Support Structures for the Preliminary Design Review

The ITER electron cyclotron emission (ECE) diagnostic system is located at Design Shield Module (DSM) 2, Equatorial Port (EP) 9 to measure electron temperature profile and electron temperature fluctuations and also to assess nonthermal electron distributions via the oblique view. Therefore, ECE has both radial and oblique views with two couples of mirrors for two different optical views. This ECE diagnostic system shall be exposed to significant power due to unabsorbed electron cyclotron heating power in the plasma. It shall also receive large electromagnetic (EM) loads up to 100 MN/m 3 force density due to the eddy currents generated by the short 16-ms transient plasma disruption. The global EM models of EP12 and EP11 with the worst case of plasma disruption Major Disruption Downward Exponential 16 ms Category III (MD_DW_EXP16MS_CATIII) have been provided by ITER. However, the support structure for these critical components, including four mirrors, is still under the design and development phase, especially during the period of preliminary design reviews (PDRs). For those small in-vessel components that are not modeled explicitly for the PDRs, we can extract the magnetic field (B) data and flux variations (dB/dt) at those locations from the global model and then use the B and dB/dt method to calculate the eddy currents, EM forces, and torques on those components in the local submodels. In conclusion, this paper will present the detailed PDR EM analysis results of the ECE components and support structures.

Electromagnetic↗

A DEEP CHANDRA ACIS STUDY OF NGC 4151. III. THE LINE EMISSION AND SPECTRAL ANALYSIS OF THE IONIZATION CONE

This paper is the third in a series in which we present deep Chandra ACIS-S imaging spectroscopy of the Seyfert 1 galaxy NGC 4151, devoted to study its complex circumnuclear X-ray emission. Emission features in the soft X-ray spectrum of the bright extended emission (L{sub 0.3-2{sub keV}} {approx} 10{sup 40} erg s{sup -1}) at r > 130 pc (2'') are consistent with blended brighter O VII, O VIII, and Ne IX lines seen in the Chandra HETGS and XMM-Newton RGS spectra below 2 keV. We construct emission line images of these features and find good morphological correlations with the narrow-line region clouds mapped in [O III] {lambda}5007. Self-consistent photoionization models provide good descriptions of the spectra of the large-scale emission, as well as resolved structures, supporting the dominant role of nuclear photoionization, although displacement of optical and X-ray features implies a more complex medium. Collisionally ionized emission is estimated to be {approx}<12% of the extended emission. Presence of both low- and high-ionization spectral components and extended emission in the X-ray image perpendicular to the bicone indicates leakage of nuclear ionization, likely filtered through warm absorbers, instead of being blocked by a continuous obscuring torus. The ratios of [O III]/soft X-ray flux are approximately constant ({approx}15) for the 1.5 kpc radius spanned by these measurements, indicating similar relative contributions from the low- and high-ionization gas phases at different radial distances from the nucleus. If the [O III] and X-ray emission arise from a single photoionized medium, this further implies an outflow with a wind-like density profile. Using spatially resolved X-ray features, we estimate that the mass outflow rate in NGC 4151 is {approx}2 M{sub Sun} yr{sup -1} at 130 pc and the kinematic power of the ionized outflow is 1.7 Multiplication-Sign 10{sup 41} erg s{sup -1}, approximately 0.3% of the bolometric luminosity of the active nucleus in NGC 4151.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of the neutron magnetic form factor at high Q-2 using the ratio method on deuterium

The 12-GeV Upgrade at Jefferson Lab will create an opportunity to dramatically extend our knowledge of the magnetic form factor of the neutron G^n_M and the other elastic, electromagnetic form factors. We describe here an approved experiment that will cover a Q2 range (3.5 – 14 GeV2) with significant discovery potential. Different theoretical approaches (generalized parton distributions, Dyson-Schwinger equations, etc) diverge is this region and existing data cannot distinguish among them. The proposed measurement will be performed in Hall B with the CLAS12 detector and will have statistical and systematic uncertainties below 3%. It is based on the ratio of electron-neutron to electron-proton scattering that was successfully applied in the CLAS detector at Jefferson Lab.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Full Hemisphere Fermi Surface Mapping Using A Novel Toroidal Electron Spectrometer

An overview is provided of a next-generation toroidal angle-resolving photoemission spectrometer, currently in operation at BESSY II. The instrument features exceptional multi-detection in energy and angle, facilitating rapid full-hemisphere photoemission measurements. The instrument is ideal for band structure and Fermi Surface (FS) mapping using Angle Resolved Photoemission Spectroscopy (ARPES). Recent full-hemisphere FS measurements of a prototypical material, copper, reveal previously unseen fine structure due to lifetime broadening, demonstrating the high angular resolution and dense {kappa}-space sampling capabilities of the instrument.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗