Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Distribution System State Estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Holistic energy analysis method for thermal management architectures of data centers

Modern high-performance computing (HPC) data centers (DCs), particularly those supporting energy-intensive artificial intelligence (AI) workloads, face escalating thermal management challenges that degrade performance through thermal throttling and drive up cooling power consumption and operational costs. To address this challenge, many have developed a wide variety of thermal management solutions (single-phase, two-phase, direct, indirect, hybrid, and more) which attempt to cool HPC DCs effectively while attempting to minimize overall system power consumption. However, the analysis of these solutions and methods to effectively compare one with another is lacking. Overall power usage effectiveness (PUE) and total-power usage effectiveness (TUE) provide a metric to quantify power consumption but fail to identify components in the system which require further optimization. To address this, we propose a holistic analytical framework – the waterfall diagram (WFD) – which leverages a waterfall chart methodology, offering a comprehensive visualization of both the thermal management system loop and heat flow pathways from individual server components to the outdoor ambient. Use of the WFD enables graphical estimations of power efficiency and cooling performance across each component of a DC cooling system and complements Sankey-style energy flow visualizations by additionally resolving stage-wise temperature changes and incremental TUE contributions. The framework is used in conjunction with simulation-based approaches, to conduct a detailed pressure drop and flow distribution analysis aimed at identifying the optimal coolant distribution architecture for a single-phase direct-to-chip water-cooled DC, which serves as the baseline for subsequent WFD analysis. Among the evaluated architectures, the 3 U modular coolant distribution architecture is found to demonstrate the best performance, considering minimal pressure drop and uniform flow distribution. In addition, TUE is calculated for each cooling loop component based on its associated pressure drop and corresponding pumping power, which are integrated into the WFD. This correlation between TUE and local temperature offers immediate insight into the power efficiency and thermal performance contributions of individual components, facilitating further development and optimization. Examples of WFD applications are presented under varying thermal loads and ambient conditions, demonstrating reasonable cooling strategies. Notably, the 3 U modular architecture maintains a consistent chip case temperature of 85°C, achieving a TUE of 1.016 at ambient temperature of 47°C, and a TUE of 1.026 at ambient temperature of 52°C. The WFD methodology provides an efficient, holistic, and streamlined framework for DC thermal management architecture assessment and enables design optimization which is important for addressing the thermal-fluidic energy challenges of current and next-generation DCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhanced Component Performance Study: Emergency Diesel Generators 1998-2024

This report presents an enhanced performance evaluation of the emergency power system (EPS) and high-pressure core spray (HPCS) emergency diesel generators (EDGs) at U.S. commercial nuclear power plants. This report evaluates component performance over time using (1) Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS) data from 1998 through 2024 and (2) maintenance unavailability performance data from Mitigating Systems Performance Index (MSPI) Basis Document data from 2002 through 2024. The objective is to show estimates of current failure probabilities and rates related to EDGs, trend these data on an annual basis, determine if the current data are consistent with the probability distributions currently recommended for use in Nuclear Regulatory Commission (NRC) probabilistic risk assessments, show how the reliability data differ for different EDG manufacturers and for EDGs with different ratings; and summarize the subcomponents, causes, detection methods, and recovery associated with each EDG failure mode. The EDG failure modes considered are fail to start (FTS), fail to load and run (FTLR), and fail to run after one hour of operation (FTR>1H). Engineering analyses were performed with respect to time-period and failure mode without regard to the actual number of EDGs at each plant. The factors analyzed include subcomponent, failure cause, detection method, recovery, manufacturer, and EDG rating. The following increasing trends were identified for EDGs for the most recent 10-year period: • EPS and HPCS EDG frequency of start demands (demands per reactor year) • EPS and HPCS EDG frequency of FTLR demands • EPS and HPCS EDG frequency of run>1H hours. The following decreasing trends were identified for EDGs for the most recent 10-year period: • EPS EDG FTR>1H failure rate • EPS EDG unreliability • EPS and HPCS EDG frequency of FTR>1H events (failures per reactor year).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fast magnetic response in gigahertz-band for columnar-structured Fe nanoparticle assembly

High density Fe-based ferromagnetic nanoparticle (NP) assembly is expected to have unique magnetic properties, such as superferromagnetism and super-spin-glass, different from magnetically isolated NP systems due to strong dipole interactions among the NPs. A high dipole interaction field, H{sub dip}, of ∼3.5 kOe can result in a high effective internal field to the magnetic moment of the NP, expecting for ultra-fast magnetic response, that is, a high magnetic resonance frequency, f{sub r}, of ∼10 GHz. However, for a simply molded Fe NP assembly, a low f{sub r} was observed due to inhomogeneous distribution of the internal field, implying the necessity of a unidirectional state of H{sub dip} for higher f{sub r}. In this study, we fabricated a columnar Fe NP assembly for realizing the unidirectional state of H{sub dip} by applying our uniquely developed external field-induced agglomeration method for monodispersed Fe NPs (13 nm in average size) as a function of the field (0–30 kOe) and volume fraction of the Fe NPs (0.5%–51%) in a polymer matrix with dimensions of 4 mm × 4 mm × 0.7 mm{sup t}. A columnar-structured Fe NP assembly was successfully achieved along an in-plane direction (defined as the x-axis) under optimized conditions. From static magnetization curves, induced uniaxial magnetic anisotropy was observed according to the shape of the columnar structure of the Fe NP assembly, where easy and hard axes of magnetization were realized along the parallel (x-axis) and normal directions (in-plane y-axis and z-axis in the thickness direction) to the external field during the process, respectively. Interestingly, this fabricated columnar-structured Fe NP assembly exhibited very high f{sub r} in the range from 3 to 11 GHz judging from the complex susceptibility spectra obtained. The f{sub r} values were well-scaled by a modified Snoek's-limit-law using demagnetization factors quantitatively estimated from the static magnetization curves. Thus, shape-induced anisotropy originating from the unidirectional state of H{sub dip} in the columnar structure of the Fe NP assembly plays an important role for high frequency magnetic response in the GHz-band.

36 MATERIALS SCIENCE↗

In-Situ Pipeline Coatings for Methane Emissions Mitigation and Quantification from Natural Gas Pipelines

Addressing the current health of the nation’s existing 3 million miles of pipeline infrastructure is key to preventing further climate change. In 2020, natural gas production exceeded 34 trillion cubic feet (Tcf). Roughly 75% of natural gas consists of methane (CH 4 ), which is up to 25 times more powerful than carbon dioxide (CO 2 ) at trapping heat within the atmosphere over a 100-year period, and studies from the Environmental Defense Fund (EDF) estimate approximately 2% of all the natural gas produced will be lost during normal operations due to unaddressed leaks. This does not even consider the risks of major disaster due to pipeline failure, or the losses and extra fuel costs incurred due to corrosion and scale deposits in under-maintained pipelines. The objective of the proposed research is to demonstrate the protection capabilities and economic benefits of Oceanit’s internal pipe surface treatment, known as DragX™. DragX™ is a chemically resistant, water-and-oil repellent nanocomposite system that can be readily applied in-situ on natural gas transmission and distribution pipelines with a minimum of surface preparation. This makes it an ideal candidate for in-place retrofitting and refurbishment of existing pipelines without the need for expensive extraction and replacement. DragX™ is also able to significantly reduce the surface roughness, and subsequently, the frictional drag forces within a pipeline, improving throughput, decreasing energy costs of pressurization and pumping, and allowing for longer pipeline operation without interruption, reducing the methane emitted during pipe isolation and venting. As part of this project, Oceanit has utilized the Department of Energy’s support to fully develop, de-risk and prove the DragX™ core technology is both economically viable and commercially desirable to pipeline operators and energy companies alike. DragX™ material properties were optimized in this effort both for ease of applicability, to provide value in certain key parameters, and was demonstrated on pilot applications exceeding 2 miles in length. Beyond the already field demonstrated applications, this innovative nanocomposite surface treatment has the potential to be the backbone for CO 2 and Hydrogen transporting pipeline infrastructure. The learnings from this project could accelerate the deployment of surface treatment technologies related to the energy transition infrastructure, thus benefitting the clean energy initiatives in the United States and all around the world.

03 NATURAL GAS↗

Highlights of NASA’s Orbital Debris Program Office In Situ and Laboratory Measurements

NASA’s Orbital Debris Program Office (ODPO) maintains various returned spacecraft materials, capabilities, and facilities used for in situ and laboratory measurements that directly support orbital debris environmental models. In situ measurements include the analysis of exposed and returned hardware surfaces. These surfaces serve as passive sensors for the small-sized micrometeoroid and orbital debris (MMOD) flux below the sensitivity of ground-based radar and optical sensors. Various instruments and techniques are used to determine the size and depth of selected impact features, and – if feasible – the composition of the projectile material. Analysis of the impactor residues enables the differentiation of MM and OD for debris below 1 mm to support modeling the OD environment. In addition, projectiles identified as OD can be further differentiated in low-, medium-, and high- density impactors based on chemical analyses. In addition to in situ measurements, the ODPO has also worked in collaboration with the U.S. Space Force Space Systems Command (formerly the U.S. Air Force Space and Missile Systems Center), the Aerospace Corporation, and the University of Florida on a laboratory-based hypervelocity impact test, DebriSat, conducted at the Air Force Arnold Engineering Development Complex in 2014. The resulting data from this impact test series are being analyzed to assess the fragments’ sizes/masses, materials/densities, shapes, and other parameters of interest. The DebriSat project provides the data needed to update NASA’s breakup models and size estimation models using the simulated orbital breakup of a modern, low Earth orbit spacecraft. Ultimately, over 200,000 fragments from this impact test will be stored at NASA Johnson Space Center (JSC) and further analyzed by the ODPO. This project will also use machine learning techniques to infer physical parameters of fragments embedded in the soft-catch foam used in the impact experiment. Applied to X-ray imagery of the foam panels, these techniques promise to minimize human-in-the-loop processes for fragment extraction and physical characterization. A brief overview of this project and data collected will be presented. Lastly, the ODPO provides various capabilities hosted at NASA JSC for optical inspections and measurements using a variety of techniques and scientific instrumentation to support both in situ and laboratory measurements. The ODPO’s Optical Measurement Center (OMC) is an advanced facility for photometric and spectroscopic laboratory measurements of targets, including fragments from the DebriSat project. The OMC simulates telescopic observations by using space-like illumination conditions and source-target-sensor orientation techniques. Additionally, the OMC is uniquely equipped to acquire pseudo-bidirectional reflectance distribution data for broadband photometric measurements, thus removing aspect angle dependencies that can affect target size estimates using the optical size estimation model. Narrow-band surface material characterization using spectroscopic instrumentation gives insight into how the albedo parameter – also important in the optical size estimation model – may vary depending on the state of the material. The OMC also performs simulations of photometric measurements using optical ray-tracing software to model the OMC optical throughput. In addition to the OMC, the ODPO houses a start-of-the-art Fragment Analysis Facility that uses multiple microscopic inspection instruments to support in situ measurements and material characterization. An overview of both facilities will be highlighted in this paper.

Orbital Debris↗

Highlights of NASA’s Orbital Debris Program Office In Situ and Laboratory Measurements

NASA’s Orbital Debris Program Office (ODPO) maintains various returned spacecraft materials, capabilities, and facilities used for in situ and laboratory measurements that directly support orbital debris environmental models. In situ measurements include the analysis of exposed and returned hardware surfaces. These surfaces serve as passive sensors for the small-sized micrometeoroid and orbital debris (MMOD) flux below the sensitivity of ground-based radar and optical sensors. Various instruments and techniques are used to determine the size and depth of selected impact features, and – if feasible – the composition of the projectile material. Analysis of the impactor residues enables the differentiation of MM and OD for debris below 1 mm to support modeling the OD environment. In addition, projectiles identified as OD can be further differentiated in low-, medium-, and high- density impactors based on chemical analyses. In addition to in situ measurements, the ODPO has also worked in collaboration with the U.S. Space Force Space Systems Command (formerly the U.S. Air Force Space and Missile Systems Center), the Aerospace Corporation, and the University of Florida on a laboratory-based hypervelocity impact test, DebriSat, conducted at the Air Force Arnold Engineering Development Complex in 2014. The resulting data from this impact test series are being analyzed to assess the fragments’ sizes/masses, materials/densities, shapes, and other parameters of interest. The DebriSat project provides the data needed to update NASA’s breakup models and size estimation models using the simulated orbital breakup of a modern, low Earth orbit spacecraft. Ultimately, over 200,000 fragments from this impact test will be stored at NASA Johnson Space Center (JSC) and further analyzed by the ODPO. This project will also use machine learning techniques to infer physical parameters of fragments embedded in the soft-catch foam used in the impact experiment. Applied to X-ray imagery of the foam panels, these techniques promise to minimize human-in-the-loop processes for fragment extraction and physical characterization. A brief overview of this project and data collected will be presented. Lastly, the ODPO provides various capabilities hosted at NASA JSC for optical inspections and measurements using a variety of techniques and scientific instrumentation to support both in situ and laboratory measurements. The ODPO’s Optical Measurement Center (OMC) is an advanced facility for photometric and spectroscopic laboratory measurements of targets, including fragments from the DebriSat project. The OMC simulates telescopic observations by using space-like illumination conditions and source-target-sensor orientation techniques. Additionally, the OMC is uniquely equipped to acquire pseudo-bidirectional reflectance distribution data for broadband photometric measurements, thus removing aspect angle dependencies that can affect target size estimates using the optical size estimation model. Narrow-band surface material characterization using spectroscopic instrumentation gives insight into how the albedo parameter – also important in the optical size estimation model – may vary depending on the state of the material. The OMC also performs simulations of photometric measurements using optical ray-tracing software to model the OMC optical throughput. In addition to the OMC, the ODPO houses a start-of-the-art Fragment Analysis Facility that uses multiple microscopic inspection instruments to support in situ measurements and material characterization. An overview of both facilities will be highlighted in this paper.

Orbital Debris↗

Comparison of Deterministic and Statistical Models for Water Quality Compliance Forecasting in the San Joaquin River Basin, California

Model selection for water quality forecasting depends on many factors including analyst expertise and cost, stakeholder involvement and expected performance. Water quality forecasting in arid river basins is especially challenging given the importance of protecting beneficial uses in these environments and the livelihood of agricultural communities. In the agriculture-dominated San Joaquin River Basin of California, real-time salinity management (RTSM) is a state-sanctioned program that helps to maximize allowable salt export while protecting existing basin beneficial uses of water supply. The RTSM strategy supplants the federal total maximum daily load (TMDL) approach that could impose fines associated with exceedances of monthly and annual salt load allocations of up to $1 million per year based on average year hydrology and salt load export limits. The essential components of the current program include the establishment of telemetered sensor networks, a web-based information system for sharing data, a basin-scale salt load assimilative capacity forecasting model and institutional entities tasked with performing weekly forecasts of river salt assimilative capacity and scheduling west-side drainage export of salt loads. Web-based information portals have been developed to share model input data and salt assimilative capacity forecasts together with increasing stakeholder awareness and involvement in water quality resource management activities in the river basin. Two modeling approaches have been developed simultaneously. The first relies on a statistical analysis of the relationship between flow and salt concentration at three compliance monitoring sites and the use of these regression relationships for forecasting. The second salt load forecasting approach is a customized application of the Watershed Analysis Risk Management Framework (WARMF), a watershed water quality simulation model that has been configured to estimate daily river salt assimilative capacity and to provide decision support for real-time salinity management at the watershed level. Analysis of the results from both model-based forecasting approaches over a period of five years shows that the regression-based forecasting model, run daily Monday to Friday each week, provided marginally better performance. However, the regression-based forecasting model assumes the same general relationship between flow and salinity which breaks down during extreme weather events such as droughts when water allocation cutbacks among stakeholders are not evenly distributed across the basin. A recent test case shows the utility of both models in dealing with an exceedance event at one compliance monitoring site recently introduced in 2020.

54 ENVIRONMENTAL SCIENCES↗

Recover Act. Verification of Geothermal Tracer Methods in Highly Constrained Field Experiments

The prediction of the geothermal system efficiency is strong linked to the character of the flow system that connects injector and producer wells. If water flow develops channels or “short circuiting” between injection and extraction wells thermal sweep is poor and much of the reservoir is left untapped. The purpose of this project was to understand how channelized flow develops in fracture geothermal reservoirs and how it can be measured in the field. We explored two methods of assessing channelization: hydraulic connectivity tests and tracer tests. These methods were tested at a field site using two verification methods: ground penetrating radar (GPR) images of saline tracer and heat transfer measurements using distributed temperature sensing (DTS). The field site for these studies was the Altona Flat Fractured Rock Research Site located in northeastern New York State. Altona Flat Rock is an experimental site considered a geologic analog for some geothermal reservoirs given its low matrix porosity. Because soil overburden is thin, it provided unique access to saturated bedrock fractures and the ability image using GPR which does not effectively penetrate most soils. Five boreholes were drilled in a “five spot” pattern covering 100 m2 and hydraulically isolated in a single bedding plane fracture. This simple system allowed a complete characterization of the fracture. Nine small diameter boreholes were drilled from the surface to just above the fracture to allow the measurement of heat transfer between the fracture and the rock matrix. The focus of the hydraulic investigation was periodic hydraulic testing. In such tests, rather than pumping or injection in a well at a constant rate, flow is varied to produce an oscillating pressure signal. This pressure signal is sensed in other wells and the attenuation and phase lag between the source and receptor is an indication of hydraulic connection. We found that these tests were much more effective than constant pumping tests in identifying a poorly connected well. As a result, we were able to predict which well pairs would demonstrate channelized flow. The focus of the tracer investigation was multi-ionic tests. In multi-ionic tests several ionic tracers are injected simultaneously and the detected in a nearby pumping well. The time history of concentration, or breakthrough curve, will show a separation of the tracers. Anionic tracers travel with the water but cationic tracer undergo chemical exchange with cations on the surface of the rock. The degree of separation is indicative of the surface area exposed to the tracer. Consequently, flow channelization will tend to decrease the separation in the breakthrough. Estimation of specific surface area (the ration of fracture surface area to formation volume) is performed through matching the breakthrough curve with a transport model. We found that the tracer estimates of surface area were confirmed the prediction of channelized flow between well pairs produced by the periodic hydraulic tests. To confirm that the hydraulic and tracer tests were correctly predicting channelize flow, we imaged the flow field using surface GPR. Saline water was injected between the well pairs which produced a change in the amplitude and phase of the reflected radar signal. A map was produced of the migration of saline tracer from these tests which qualitatively confirmed the flow channelization predicted by the hydraulic and tracer tests. The resolution of the GPR was insufficient to quantitatively estimate swept surface area, however. Surface GPR is not applicable in typical geothermal fields because the penetration depths do not exceed 10’s of meters. Nevertheless, the method of using of phase to measure electrical conductivity and the assessment of antennae polarization represent a significant advancement in the field of surface GPR. The effect of flow character on fracture / rock thermal exchange was evaluated using heated water as a tracer. Water elevated 30 degrees C above the formation water was circulated between two wells pairs. One well pair had been identified in hydraulic and tracer testing as well connected and the other poorly connected. Temperature rise was measured in the adjacent rock matrix using coiled fiber optic cable interrogated for temperature using a DTS. This experimental design produced over 4000 temperature measurements every hour. We found that heat transfer between the fracture and the rock matrix was highly impacted by the character of the flow field. The strongly connected wells which had demonstrated flow channelization produced heat rise in a much more limited area than the more poorly connected wells. In addition, the heat increase followed the natural permeability of the fracture rather than the induced flow field. The primary findings of this work are (1) even in a single relatively planar fracture, the flow field can be highly heterogeneous and exhibit flow channeling, (2) channeling results from a combination of fracture permeability structure and the induced flow field, and (3) flow channeling leads to reduced heat transfer. Multi-ionic tracers effectively estimate relative surface area but an estimate of ion-exchange coefficients are necessary to provide an absolute measure of specific surface area. Periodic hydraulic tests also proved a relative indicator of connectivity but cannot prove an absolute measure of specific surface area.

15 GEOTHERMAL ENERGY↗

Compositing and Characterization of SE Quadrant Waste Exemplars

This report outlines the experimental investigation and characterization of transport properties in Hanford SE quadrant High-Level Waste (HLW). The goal of the study was to establish baseline behaviors of bulk composite rheology and settling characteristics to facilitate waste treatment process design for the Waste Treatment and Immobilization Plant (WTP) and avoid waste conditions and properties favorable to bubble cascade gas release events. The study focused on two major objectives: 1) identifying, obtaining, and preparing relevant Hanford tank waste samples for evaluation and 2) quantifying the “as-received” rheology and transport properties of the samples. Twenty-three centrifuged core segments originating from tanks AN-101, AN-106, and AW-105 were selected based on compositional relevance to SE quadrant PUREX cladding waste. These materials were composited into five waste composites enriched with target analytes: aluminum (Al), iron (Fe), phosphate (PO 4 ), uranium (U), and zirconium (Zr). Physical property and transport testing examined particle size distributions, bulk densities, settling behaviors, rheological properties, shear strengths, and just-suspended mixing speeds (NJS). Testing revealed two distinct composite classifications based on rheological characteristics: non-Newtonian composites (Fe and PO 4 ) and Newtonian composites (Al, U, and Zr). The Fe and PO 4 composites exhibited slow settling rates and reduced mobilization proclivity, attributable to strong particle-particle interactions and the formation of yield structures within non-Newtonian slurries. In contrast, the Al, U, and Zr composites displayed rapid settling and dense compaction behaviors, indicative of minimal structuring and interactions. Shear strengths for all composites were generally low relative to prior studies of SE quadrant waste, with only the U composite showing elevated strength approaching values reported in previous literature. Repeat shear strength measurements revealed contributions from dense granular material in the U composite and stronger cohesive properties in the Al composite. Settling data highlighted hindered settling behavior, with rates falling more than one order of magnitude below estimates based on Stokes’ law and rate decreasing as composite UDS content increased. NJS testing demonstrated different mobilization behaviors between cohesive and granular composites. The Fe composite required the highest mixing rate for resuspension, while the Al composite was the easiest to resuspend. Comparison of measured NJS against predictions made using the Zwietering correlation suggests non-Newtonian behavior alters resuspension mechanics, rendering non-Newtonian systems more stable against resuspension lift forces relative to their granular counterparts.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MODELING TRANSPORT IN THE DOWN GRADIENT PORTION OF THE 200-PO-1 OPERABLE UNIT AT THE HANFORD SITE

Remedial Investigations are underway for the 200-PO-l Operable Unit (OU) at the U.S. Department of Energy's Hanford Site in Washington State. To support the baseline risk assessment and evaluation of remedial alternatives, fate and transport modeling is being conducted to predict the future concentration of contaminants of potential concern in the 200-PO-1 OU. This study focuses on modeling the 'down gradient' transport of those contaminants that migrate beyond the 3-D model domain selected for performing detailed 'source area' modeling within the 200-PO-1 OU. The down gradient portion is defined as that region of the 200-PO-1 OU that is generally outside the 200 Area (considered 'source area') of the Hanford Site. A 1-D transport model is developed for performing down gradient contaminant fate and transport modeling. The 1-D transport model is deemed adequate based on the inferred transport pathway of tritium in the past and the observation that most of the contaminant mass remains at or near the water table within the unconfined aquifer of the Hanford Formation and the Cold-Creek/Pre-Missoula Gravel unit. The Pipe Pathway feature of the GoldSim software is used to perform the calculations. The Pipe Pathway uses a Laplace transform approach to provide analytical solutions to a broad range of advection-dominated mass transport systems involving one-dimensional advection, longitudinal dispersion, retardation, decay and ingrowth, and exchanges with immobile storage zones. Based on the historical concentration distribution data for the extensive tritium plume in this area, three Pipe Pathways are deemed adequate for modeling transport of contaminants. Each of these three Pipe Pathways is discretized into several zones, based on the saturated thickness variation in the unconfined aquifer and the location of monitoring wells used for risk assessment calculation. The mass fluxes of contaminants predicted to exit the source area model domain are used as an input to the down gradient model, while the flow velocities applied are based on the present-day hydraulic gradients and estimation of hydraulic conductivity in the unconfined aquifer. The results of the calculation indicate that the future concentrations of contaminants of potential concern in the down gradient portion of the 200-PO-1 OU declines with time and distance.

54 ENVIRONMENTAL SCIENCES↗

Integral Reactor Containment Condensation Model and Experimental Validation

This NEUP funded project, NEUP 12-3630, is for experimental, numerical and analytical studies on high-pressure steam condensation phenomena in a steel containment vessel connected to a water cooling tank, carried out at Oregon State University (OrSU) and the University of Wisconsin at Madison (UW-Madison). In the three years of investigation duration, following the original proposal, the planned tasks have been completed: (1) Performed a scaling study for the full pressure test facility applicable to the reference design for the condensation heat transfer process during design basis accidents (DBAs), modified the existing test facility to route the steady-state secondary steam flow into the high pressure containment for controllable condensation tests, and extended the operations at negative gage pressure conditions (OrSU). (2) Conducted a series of DBA and quasi-steady experiments using the full pressure test facility to provide a reliable high pressure condensation database (OrSU). (3) Analyzed experimental data and evaluated condensation model for the experimental conditions, and predicted the prototypic containment performance under accidental conditions (UW-Madison). A film flow model was developed for the scaling analysis, and the results suggest that the 1/3 scaled test facility covers large portion of laminar film flow, leading to a lower average heat transfer coefficient comparing to the prototypic value. Although it is conservative in reactor safety analysis, the significant reduction of heat transfer coefficient (50%) could under estimate the prototypic condensation heat transfer rate, resulting in inaccurate prediction of the decay heat removal capability. Further investigation is thus needed to quantify the scaling distortion for safety analysis code validation. Experimental investigations were performed in the existing MASLWR test facility at OrST with minor modifications. A total of 13 containment condensation tests were conducted for pressure ranging from 4 to 21 bar with three different static inventories of non-condensable gas. Condensation and heat transfer rates were evaluated employing several methods, notably from measured temperature gradients in the HTP as well as measured condensate formation rates. A detailed mass and energy accounting was used to assess the various measurement methods and to support simplifying assumptions required for the analysis. Condensation heat fluxes and heat transfer coefficients are calculated and presented as a function of pressure to satisfy the objectives of this investigation. The major conclusions for those tests are summarized below: (1) In the steam blow-down tests, the initial condensation heat transfer process involves the heating-up of the containment heat transfer plate. An inverse heat conduction model was developed to capture the rapid transient transfer characteristics, and the analysis method is applicable to SMR safety analysis. (2) The average condensation heat transfer coefficients for different pressure conditions and non-condensable gas mass fractions were obtained from the integral test facility, through the measurements of the heat conduction rate across the containment heat transfer plate, and from the water condensation rates measurement based on the total energy balance equation. 15 (3) The test results using the measured HTP wall temperatures are considerably lower than popular condensation models would predict mainly due to the side wall conduction effects in the existing MASLWR integral test facility. The data revealed the detailed heat transfer characteristics of the model containment, important to the SMR safety analysis and the validation of associated evaluation model. However this approach, unlike separate effect tests, cannot isolate the condensation heat transfer coefficient over the containment wall, and therefore is not suitable for the assessment of the condensation heat transfer coefficient against system pressure and noncondensable gas mass fraction. (4) The average condensation heat transfer coefficients measured from the water condensation rates through energy balance analysis are appropriate, however, with considerable uncertainties due to the heat loss and temperature distribution on the containment wall. With the consideration of the side wall conduction effects, the results indicate that the measured heat transfer coefficients in the tests is about 20% lower than the prediction of Dehbi’s correlation, mainly due to the side wall conduction effects. The investigation also indicates an increase in the condensation heat transfer coefficient at high containment pressure conditions, but the uncertainties invoked with this method appear to be substantial. (5) Non-condensable gas in the tests has little effects on the condensation heat transfer at high elevation measurement ports. It does affect the bottom measurements near the water level position. The results suggest that the heavier non-condensable gas is accumulated in the lower portion of the containment due to stratification in the narrow containment space. The overall effects of the non-condensable gas on the heat transfer process should thus be negligible for tall containments of narrow condensation spaces in most SMR designs. Therefore, the previous correlations with noncondensable gas effects are not appropriate to those small SMR containments due to the very poor mixing of steam and non-condensable gas. The MELCOR simulation results agree with the experimental data reasonably well. However, it is observed that the MELCOR overpredicts the heat flux for all analyzed tests. The MELCOR predicts that the heat fluxes for CCT’s approximately range from 30 to 45 kW/m2 whereas the experimental data (averaged) ranges from about 25 to 40 kW/m2. This may be due to the limited availability of liquid film models included in MELCOR. Also, it is believed that due to complex test geometry, measured temperature gradients across the heat transfer plate may have been underestimated and thus the heat flux had been underestimated. The MELCOR model predicts a film thickness on the order of 100 microns, which agrees very well with film flow model developed in this study for scaling analysis. However, the expected differences in film thicknesses for near vacuum and near atmospheric test conditions are not significant. Further study on the behavior of condensate film is expected to refine the simulation results. Possible refinements include but are not limited to, the followings: CFD simulation focusing on the liquid film behavior and benchmarking with experimental analyses for simpler geometries. 16 1 INTRODUCTION This NEUP funded project, NEUP 12-3630, is for experimental, numerical and analytical studies on high-pressure steam condensation phenomena in a steel containment vessel connected to a water cooling tank, carried out at Oregon State University (OrSU) and the University of Wisconsin at Madison (UW-Madison). The experimental results are employed to validate the containment condensation model in reactor containment system safety analysis code for integral SMRs. Such a containment condensation model is important to demonstrate the adequate cooling. In the three years of investigation, following the original proposal, the following planned tasks have been completed: (1) Performed a scaling study for the full pressure test facility applicable to the reference design for the condensation heat transfer process during design basis accidents (DBAs), modified the existing test facility to route the steady-state secondary steam flow into the high pressure containment for controllable condensation tests, and extended the operations at negative gage pressure conditions (OrSU). (2) Conducted a series of DBA and quasi-steady experiments using the full pressure test facility to provide a reliable high pressure condensation database (OrSU). (3) Analyzed experimental data and evaluated condensation model for the experimental conditions, and predicted the prototypic containment performance under accidental conditions (UW-Madison). The results are applicable to integral Small Modular Reactor (SMR) designs, including NuScale, mPower, Westinghouse SMR, Holtec-160 and other integral reactors with small containments of relatively high pressures under accidental conditions. Testing has been conducted at the OrSU laboratory in the existing MASLWR (Multi-Application Small Light Water Reactor) integral test facility sponsored by the US Department of Energy. Its highpressure stainless steel containment model (~2 MPa) is scaled to the NuScale SMR currently under development at NuScale Power, Inc.. Minor modifications to the model containment have been made to control the non-condensable gas fraction and to utilize the secondary loop stable steam flow for condensation testing. UW-Madison has developed a containment condensation model, which leveraged previous validated containment heat transfer work carried out at UW-Madison, and extended the range of applicability of the model to integral SMR designs that utilize containment vessels of high heat transfer efficiencies. In this final report, the research background and literature survey are presented in Chapter 2 and 3, respectively. The test facility description and modifications are summarized in Chapter 4, and the scaling analysis is introduced in Chapter 5. The tests description, procedures, and data analysis are presented in Chapter 6, while the numerical modeling is presented in Chapter 7, followed by a conclusion section in Chapter 8.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Value of Geothermal Energy Storage for Supply-Side and Demand-Side Applications

This report presents the results of a study examining the value potential for geothermal energy storage (GES), a long-duration energy storage resource that stores thermal and/or geomechanical energy in the subsurface. GES could benefit the overall U.S. power system by temporally shifting electricity generation (supply-side) or meeting building heating and cooling load (demand-side). This report analyzes supply-side and demand-side opportunities independently because of differences in applications and models. Currently there is significant uncertainty about the development costs for GES, with only a limited number of demonstration plants for electric energy storage and building heating and cooling storage developments. In this report, we estimate the value of supply-side and demand-side GES to the bulk power system in the contiguous United States. Because of the significant uncertainty about GES development costs, this analysis does not consider GES deployment costs but instead focuses on the value of GES to the U.S. electricity system. The estimated values of GES provide reference points for economically competitive commercial cost targets. Supply-side GES is modeled as part of an enhanced geothermal system (EGS) generation plant in NREL's Regional Energy Deployment System (ReEDS) capacity expansion model (Ho et al. 2021). In contrast to conventional geothermal plants, which generate constant power, EGS plants have unique features that may allow for in-reservoir energy storage for flexible generation. Demand-side GES for heating and cooling, including seasonal hot and cold storage and short-duration heat pump storage, is incorporated into a price-taker model using Cambium electricity marginal cost projections. To establish an upper bound for the value of GES, analysis focused on favorable scenarios for storage with high generation from zero marginal cost, variable renewable energy resources. High penetrations of variable renewable energy generation can increase hourly electricity price variability, which increases the value of temporal energy arbitrage for storage technologies like GES.

15 GEOTHERMAL ENERGY↗

Optimization-Based Dynamic Voltage Support of Microgrids Using Energy Storage Systems

A microgrid network is characterized by a high R/X ratio, making the voltage more sensitive to active power changes compared to bulk power systems, where the voltage is regulated primarily by reactive power. Due to its sensitivity, voltage control approaches for microgrids should also consider the active power input coupling, making it very different from conventional power systems. Additionally, as the energy costs associated with active and reactive powers are different and the operational conditions of microgrids connected to active distribution systems vary over time, the ideal controller to provide voltage support must be flexible enough to handle these technical and operational constraints. This paper proposes a model predictive control approach to provide dynamic voltage support using energy storage systems. This approach uses a simplified predictive model of the system to solve the model predictive control problem. By proper selection of model predictive control weighting parameters, the quality of service provided can be adjusted to achieve the desired performance. A simulation study in MATLAB/Simulink validates the proposed approach for the Cordova, Alaska microgrid. Results show that the performance of the voltage support can be adjusted depending on the choice of weight and constraints of the controller.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electronic Spin Relaxation and Clustering in High-Pressure High-Temperature Synthesized Microcrystalline Diamond Particles with Reduced Nitrogen Content

The negatively charged nitrogen-vacancy (NV – ) color center in diamonds is widely studied because of numerous applications of this unique quantum system in sensing and quantum information sciences. While substitutional nitrogen is required to form the NV – centers in diamond, it also yields other paramagnetic defects─primarily the neutrally charged substitutional nitrogen centers (P1)─that decrease NV – spin coherence, which in turn degrades performance in applications. Herein, we investigate high-pressure high-temperature synthesized diamond microparticles (ca. 140–185 μm) having lower─ranging from 3 to 38 ppm─than the typical nitrogen content of type 1b diamond ( ca. 100 ppm and higher) typically used for the production of fluorescent diamond particles with NV – centers. A suite of electron paramagnetic resonance, optically detected magnetic resonance, and nuclear magnetic resonance methods are used to characterize spin properties of P1 and NV – centers in the particles. Upon decreasing the nitrogen content from 29 to 3 ppm, the ensemble NV – T 2 relaxation time increased by about 3-fold as measured directly in the Hahn Echo experiment at magnetic field of 1.2 T. Analysis of electronic relaxation of P1 centers revealed the existence of at least two distinct populations of P1 centers, consisting of fast and slower relaxing spins and allowed for an estimation of local concentrations. Even with <10 ppm nitrogen contents, the analysis indicated a highly heterogeneous distribution of P1 centers, suggesting the possibility of P1 spin clustering even at low nitrogen concentrations. The combined data demonstrate that the particles prepared from HPHT diamond with a low nitrogen content offer improved spin properties that are beneficial for NV – sensing applications.

Carbon↗

Hadron collider potential for excited bosons search

The e {sup +} e {sup −} and μ{sup +}μ{sup −} dilepton final states are the most clear channels for a new heavy neutral resonance search. Their advantage is that usually in the region of expected heavy-mass resonance peak the main irreducible background, from the Standard Model Drell-Yan process, contributes two orders of magnitude smaller than the signal. In this paper we consider the future prospects for search for the excited neutral Z*-bosons. The bosons can be observed as a Breit-Wigner resonance peak in the dilepton invariant mass distributions in the same way as the well-known extra gauge Z′ bosons. However, the Z* bosons have unique signatures in transverse momentum, angular and pseudorapidity distributions of the final leptons, which allow to distinguish them from the other heavy neutral resonances. At present only the ATLAS Collaboration has looked for such new excitations at the Large Hadron Collider and has published its results for 7 TeV collision energy. After successful comparison of our evaluation with these official results we present our estimations for the discovery potential and the exclusion limits on the Z*-boson search in pp collisions at higher centre-of-mass energies and different luminosities. In particular, LHC Run 2 can discover Z*-boson with its mass up to 5.3 TeV, while the High Luminosity LHC can extend that reach to 6.2 TeV. The High Energy LHC (with collision energy of 33 TeV) will be able to probe two times heavier resonance masses at the same integrated luminosities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Aerosol Vertical Profiling at Oliktok Point (AVPOP) Field Campaign Report

Aerosols are an important component of the atmospheric system through their various impacts on climate. Notably, the largest uncertainty of the energy budget (i.e., radiative forcing estimate) is the aerosol indirect effect. Aerosol-induced microphysical modifications influence cloud lifetime and albedo. However, constraining aerosol-cloud impacts in climate models, specifically in regions such as the Arctic, remains a significant challenge due to limited observations. The efficacy of an aerosol to impact the arctic energy budget largely depends on its concentration, composition, and source. While ground-based measurements will provide a consistent, high-resolution time series of aerosol observations, the arctic atmosphere can be stratified, and thus what is observed on the ground may not be representative of the aerosol aloft. A key gap in arctic aerosol research is routine vertical profiling of abundance and source characterization. Previous work outside of the Arctic has focused on using launched or tethered balloon systems (LBS and TBS, respectively) to measure vertical profiles of aerosol size distributions and has demonstrated the utility of such observations (e.g., Hofmann et al. 1989; Hofmann 1993; Iwasaka et al. 2003; Kim et al. 2003; Tobo et al. 2007). More specifically, particle spectrometers have also been deployed via TBS systems (de Boer et al. 2018; Greenberg et al. 2009; Maletto et al. 2003; Renard et al. 2016; Wehner et al. 2007; Siebert et al. 2004) affording information on aerosol layer locations and evolution by means of multiple profiles. Filter samples for post-processing of aerosol composition and ice nucleation properties have also been conducted in mid-latitudes (Creamean et al. 2018). However, while these studies present novel measurements of aerosol vertical profiling via balloon systems, few exist to date in the Arctic. The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility TBS is composed of a variety of winches, balloons, and instrumentation that flies within ARM’s Restricted Airspace (R-2204) at the third ARM Mobile Facility (AMF3) at Oliktok Point, Alaska (Figure 1). The system payload comprises instruments that can simultaneously collect in situ data on horizontal winds, ice microphysics, turbulence, thermodynamic state, aerosols, and the cloud-top environment (https://www.arm.gov/capabilities/instruments/tbs). Recent campaigns at AMF3 have involved the use of the ARM helikite, which is a balloon-kite hybrid that uses lighter-than-air principles to obtain its initial lift and a kite to achieve stability and dynamic lift. Additional information on the specifications of the helikite TBS can be found in the ARM TBS handbook (Dexheimer 2018).

Oliktok Point, North Slope of Alaska,, tethered ba↗

Acquisition and Early Losses of Rare Gases from the Deep Earth

Direct observations show that the deep Earth contains rare gases of solar composition distinct from those in the atmosphere. We examine the implications of mantle rare gas characteristics on acquisition of rare gases from the solar nebula and subsequent losses due to a large impact. Deep mantle rare gas concentrations and isotopic compositions can be obtained from a model of transport and distribution of mantle rare gases. This model assumes the lower mantle closed early, while the upper mantle is open to subduction from the atmosphere and mass transfer from the lower mantle. Constraints are derived that can be incorporated into models for terrestrial volatile acquisition: (1) Calculated lower-mantle Xe-isotopic ratios indicate that the fraction of radiogenic Xe produced by I-129 and Pu-244 during the first about 10(exp 8) yr was lost, a conclusion also drawn for atmospheric Xe. Thus, either the Earth was made from materials that had lost >99% of rare gases about (0.7-2) x 10(exp 8) yr after the solar system formed, or gases were then lost from the fully formed Earth. (2) Concentrations of 3He and 20Ne in the lower mantle were established after these losses. (3) Neon-isotopic data indicates that mantle Ne has solar composition. The model allows for solar Ar/Ne and Xe/Ne in the lower mantle if a dominant fraction of upper mantle Ar and Xe are subduction-derived. If Earth formed in the presence of the solar nebula, it could have been melted by accretional energy and the blanketing effect of a massive, nebula-derived atmosphere. Gases from this atmosphere would have been sequestered within the molten Earth by dissolution at the surface and downward mixing. It was found that too much Ne would be dissolved in the Earth unless the atmosphere began to escape when the Earth was only partially assembled. Here we consider conditions required to initially dissolve sufficient rare gases to account for the present lower mantle concentrations after subsequent losses at 10(exp 8) yr. It is assumed that equilibration of the atmosphere with a thoroughly molten mantle was rapid, so that initial abundances of gases retained in any mantle layer reflected surface conditions when the layer solidified. For subsequent gas loss of 99.5% and typical solubility coefficients, a total pressure of 100 atm was required for an atmosphere of solar composition. Calculations of the pressure at the base of a primordial atmosphere indicate that this value might be exceeded by an order of magnitude or more for an atmosphere supported by accretional energy. Surface temperatures of about 4000 K would have been produced, probably high enough to melt the deep mantle. Initial distributions of retained rare gases would then be determined by the history of surface pressure and temperature during mantle cooling and solidification, i.e., the coupled cooling of Earth and atmosphere. The Earth's thermal state was determined by its surface temperature and the efficiency of convection in the molten mantle, estimated to be sufficient to maintain an adiabatic gradient. Because the melting curve is steeper than the adiabat, solidification of the mantle proceeded outward from the interior. Incorporation of atmospheric gases in the mantle therefore occurred over a range in surface temperature of a few thousand degrees Kelvin. The thermal state of the atmosphere was controlled by total luminosity of the Earth (energy) released by accreting planetesimals and the cooling Earth), nebular temperature and pressure, and atmospheric opacity. The energy released by accretion declined with time as did nebular pressure. Analytical solutions for an idealized (constant opacity radiative atmosphere show that declining energy sources under constant nebular conditions result in slowly diminishing surface temperature but dramatically increasing surface pressure. For such an atmosphere with declining nebular pressure but constant total luminosity, surface pressure decreases gradually with decreasing temperaure. A decline in accretion luminosity might be compensated by energy released as the mantle cools for about 10(exp 5) year, after which luminosity must decline. The total complement of dissolved rare gases will depend on the particular evolutionary path determined by the declining accretional luminosity, the Earth thermal history, removal of the nebula, and opacity variations of the atmosphere. Models for these coupled evolutionary histories for Earth's acquisition of nebular-derived noble gases are in progress. The later losses required at about 10(exp 8) yr (depleting the interior concentrations of the sequestered solar gases by a factor of > 100) were presumably related to the major impact in which the Moon formed.

Porcelli, D.↗

Real-Time Multiregional Market-to-Market Congestion Management Through Exchange of Relief Cost Curve

This paper introduces a novel method for multiregional market-to-market (M2M) coordinated congestion management. It identifies shortcomings in existing M2M approaches, where Regional Transmission Organizations (RTOs) exchange shadow prices and relief requests to optimize congestion relief allocations across interconnected regions. Two methods are proposed to enhance flow and price convergence. The first method proposes that both Regional Transmission Organizations (RTOs) use state-estimator flows directly to determine relief requirements, eliminating delays and potential oscillations caused by using market flows calculated from the prior period under existing M2M approach. The second method involves exchanging transmission relief cost curves, enabling each RTOs to integrate other RTOs' relief costs curve into its real-time security-constrained economic dispatch (SCED). This method can effectively extend the coordination to multiple transmission lines and across more than two RTOs. The alternating direction method of multipliers (ADMM) is also applied to the M2M coordination problem and compared with the proposed methods. Case studies on small and large-scale systems demonstrate the effectiveness of these approaches.

24 POWER TRANSMISSION AND DISTRIBUTION↗