Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Distributed Generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Integrated Transmission-Distribution Multi-Period Switching for Wildfire Risk Mitigation: Improving Speed and Scalability with Distributed Optimization: Preprint

With increasingly severe wildfire conditions driven by climate change, utilities must manage the risk of wildfire ignitions from electric power lines. During "public safety power shutoff'" events, utilities de-energize power lines to reduce wildfire ignition risk, which may result in load shedding. Distributed energy resources provide flexibility that can help support the system to reduce load shedding when lines are de-energized. We investigate a coordinated transmission-distribution optimization problem that balances wildfire risk mitigation and load shedding. We model distribution systems that include battery energy storage systems which may support loads when transmission lines are de-energized. This multi-period integrated transmission-distribution optimal switching problem jointly optimizes line switching decisions, the generators' setpoints, load shedding, and the batteries' states of charge, resulting in significant computational challenges. To improve scalability, we decompose the problem over both space and time and apply a distributed optimization algorithm. Using a large-scale synthetic California test case with realistic distribution models and real wildfire risk data, we show that distributed optimization can solve large-scale multi-period switching problems that are otherwise intractable for centralized solvers. We also discuss challenges and future directions for improving the distributed algorithm's convergence performance as the number of time periods increases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Technical Assistance for Bainbridge Island, Washington

The City of Bainbridge Island, Washington, worked with the Energy Technology Innovation Partnership Project (ETIPP) to understand how to improve the reliability of its electric grid and work toward its goal of increasing local energy generation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Extracting Resilience Metrics From Distribution Utility Data Using Outage and Restore Process Statistics

Resilience curves track the accumulation and restoration of outages during an event on an electric distribution grid. We show that a resilience curve generated from utility data can always be decomposed into an outage process and a restore process and that these processes generally overlap in time. We use many events in real utility data to characterize the statistics of these processes, and derive formulas based on these statistics for resilience metrics such as restore duration, customer hours not served, and outage and restore rates. The formulas express the mean value of these metrics as a function of the number of outages in the event. We also give a formula for the variability of restore duration, which allows us to predict a maximum restore duration with 95% confidence. Overall, we give a simple and general way to decompose resilience curves into outage and restore processes and then show how to use these processes to extract resilience metrics from standard distribution system data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Developing Component-Specific Prior Distributions for Common Cause Failure Alpha Factors

This report presents the development of component-specific common cause failure (CCF) prior distributions for five component categories: pump, valve, strainer, generator, and other. For ease in comparing these component-specific CCF priors with the 2015 generic CCF priors, the same method used to develop the 2015 generic CCF priors was also employed in this report, along with the same set of failure data (1997–2015) featured in INL/EXT-21-43723. For selected CCF templates, this report also evaluates the effects of applying component-specific priors to CCF parameters.

99 GENERAL AND MISCELLANEOUS↗

Unravelling the radiation-induced redox chemistry of plutonium ions in aqueous solution

Plutonium plays a critical role in nuclear fuel cycle technologies, but our understanding of its fundamental radiation-induced redox chemistry is limited. Changes in oxidation states affect the speciation and transport of plutonium ions in solution. For example, solvent extraction techniques used to separate and recover plutonium from used nuclear fuel rely on the selective formation, maintenance, and complexation of specific plutonium oxidation states. However, radiolytically generated radicals, ions, and molecules can drive the oxidation state distribution of plutonium ions far from equilibrium, ultimately changing the physical and chemical properties of the bulk system. These radiation-induced processes are inevitable due to the ionizing radiation fields generated by the radioactive decay of plutonium and its daughter nuclides. Therefore, mechanistically understanding how plutonium's various oxidation states respond to ionizing radiation is essential for predicting its behavior in solution. Here, we present significant advances in our understanding of radiation-induced plutonium redox chemistry by using time-resolved (electron pulse) and dose accumulation (alpha and gamma) irradiation techniques, along with quantitative multiscale modeling methods.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A Fast Flexibility-Driven Generation Portfolio Planning Method for Sustainable Power Systems

We are witnessing an acceleration in the uptake of renewable energy in power systems. Because of the associated variability and uncertainty of renewables, power systems need to have an adequate supply of flexibility to allow for suitable management of short-term operations. So far most of the work in this area has neglected how flexibility needs associated with renewables are fulfilled as part of dispatchable generation capital investments decisions. To address this challenge, we propose an approach to plan the dispatchable generation mix of a power system as needed to counteract variability and uncertainty associated with significant shares of variable renewable generation. The approach exploits the linear time-invariant feature of variable generation variability using historical phase planes of capacity (in MW) and ramp (in MW/min) to bridge the gap between long-term capacity planning and short-term intra-hour flexibility needs. This approach is much more computationally tractable than other proposals, while also being able to capture adequately short-term operational features like ramping and net load variability. Numerical tests are performed on realistic datasets to substantiate the effectiveness of the approach.

bulk power system planning↗

Reconfigurable Real-Time Power Grid Emulator for Systems With High Penetration of Renewables

Novel power system control and new utility devices need to be tested before their actual deployment to the power grid. To assist with such a testing need, real-time digital emulators such as RTDS and Opal-RT can be used to connect to the physical world and form a hardware in the loop (HIL) emulation. However, due to the limitations of today's computational resources, the accuracy and fidelity suffer from different levels of model reductions in purely digital simulations. CURENT has developed a reconfigurable electric grid hardware testbed (HTB) to overcome the limitations of digital emulators. The HTB has been used to develop measurement, control, modeling, and actuation techniques for a national grid with a high penetration of renewables. The power electronic-based system includes emulators for synchronous generators; photovoltaics with grid-interfacing inverter; wind turbines; induction motor loads, ZIP loads, power electronic loads; batteries; ac and dc transmission lines; short circuit faults and grid relay protection; and a multiterminal HVDC overlay including power electronics interfaces. The system contains real elements of power flow, measurement, communication, protection, and control that mimic what would be seen in an actual electric grid. This paper presents an overview of the HTB and several scenarios that have been run to determine control and actions needed for the future power grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evidence of Nonlinear Seismic Effects in the Earth from Downhole Distributed Acoustic Sensors

Seismic velocities and elastic moduli of rocks are known to vary significantly with applied stress, which indicates that these materials exhibit nonlinear elasticity. Monochromatic waves in nonlinear elastic media are known to generate higher harmonics and combinational frequencies. Such effects have the potential to be used for broadening the frequency band of seismic sources, characterization of the subsurface, and safety monitoring of civil engineering infrastructure. However, knowledge on nonlinear seismic effects is still scarce, which impedes the development of their practical applications. To explore the potential of nonlinear seismology, we performed three experiments: two in the field and one in the laboratory. The first field experiment used two vibroseis sources generating signals with two different monochromatic frequencies. The second field experiment used a surface orbital vibrator with two eccentric motors working at different frequencies. In both experiments, the generated wavefield was recorded in a borehole using a fiber-optic distributed acoustic sensing cable. Both experiments showed combinational frequencies, harmonics, and other intermodulation products of the fundamental frequencies both on the surface and at depth. Laboratory experiments replicated the setup of the field test with vibroseis sources and showed similar nonlinear combinations of fundamental frequencies. Amplitudes of the nonlinear signals observed in the laboratory showed variation with the saturating fluid. These results confirm that nonlinear components of the wavefield propagate as body waves, are likely to generate within rock formations, and can be potentially used for reservoir fluid characterization.

58 GEOSCIENCES↗

Failure Probability Constrained AC Optimal Power Flow

Despite cascading failures being the central cause of blackouts in power transmission systems, existing operational and planning decisions are made largely by ignoring their underlying cascade potential. This paper posits a reliability-aware AC Optimal Power Flow formulation that seeks to design a dispatch point which has a low operator-specified likelihood of triggering a cascade starting from any single component outage. By exploiting a recently developed analytical model of the probability of component failure, our Failure Probability-constrained ACOPF (FP-ACOPF) utilizes the system's expected first failure time as a smoothly tunable and interpretable signature of cascade risk. Here, we use techniques from bilevel optimization and numerical linear algebra to efficiently formulate and solve the FP-ACOPF using off-the-shelf solvers. Extensive simulations on the IEEE 118-bus case show that, when compared to the unconstrained and N-1 security-constrained ACOPF, our probability-constrained dispatch points can significantly lower the probabilities of long severe cascades and of large demand losses, while incurring only minor increases in total generation costs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Variable frequency response testbed to validate protective relays up to 20 kHz☆

Microgrids operate in islanding or utility grid mode. In islanding mode, distributed energy sources with power electronics inverters can generate fault currents over a wide range of frequencies. To gain a better understanding of the nature of these events, it is crucial to measure currents at frequencies of up to 20 kHz at transient states with protective relays. Protective relays at these frequency responses should be tested prior to being installed in microgrids. However, testing at high-frequency currents cannot be done with Relay Test Equipment (RTE) that generate signals up to 50th Harmonic for 60 Hz (3 kHz). In this study, a frequency response method and testbed for high-frequency currents of up to 20.16 kHz was developed and tested. The testbed utilized a RTE and High-Frequency Power Source/ Amplifier. Furthermore, frequency relay experiments were run at frequencies of up to 1 and 20.16 kHz at a current magnitude of 0.1 and 0.5 A, respectively. The events were collected, and the current magnitude and frequency were plotted at time and frequency domain, respectively. The study of current magnitude and frequencies of up to 20.16 kHz for two overcurrent relays was performed and validated the variable frequency testbed and methodology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Imaging plant metabolism in situ

Abstract Mass spectrometry imaging (MSI) has emerged as an invaluable analytical technique for investigating the spatial distribution of molecules within biological systems. In the realm of plant science, MSI is increasingly employed to explore metabolic processes across a wide array of plant tissues, including those in leaves, fruits, stems, roots, and seeds, spanning various plant systems such as model species, staple and energy crops, and medicinal plants. By generating spatial maps of metabolites, MSI has elucidated the distribution patterns of diverse metabolites and phytochemicals, encompassing lipids, carbohydrates, amino acids, organic acids, phenolics, terpenes, alkaloids, vitamins, pigments, and others, thereby providing insights into their metabolic pathways and functional roles. In this review, we present recent MSI studies that demonstrate the advances made in visualizing the plant spatial metabolome. Moreover, we emphasize the technical progress that enhances the identification and interpretation of spatial metabolite maps. Within a mere decade since the inception of plant MSI studies, this robust technology is poised to continue as a vital tool for tackling complex challenges in plant metabolism.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LuSEE-night power distribution system design

The Lunar Surface Electromagnetic Experiment at Night (LuSEE-Night) is a low-frequency, 0.5 to 50 MHz, radio experiment on the radio-quiet far side of the Moon. The instrument will be launched by NASA Commercial Lunar Payload Services in 2026. The LuSEE-Night instrument core is composed of a radio frequency spectrometer (SPT) processing signals from four antennas, the Data Controller Board (DCB), low electromagnetic interference (EMI) Picket Fence Power Supply (PFPS), and Power Distribution Unit (PDU). The battery powers the instrument during the lunar night and stores energy harvested by the solar panel array during the lunar day. The battery charging is controlled by the Power Conditioning and Distribution Unit (PCDU). The unregulated power is supplied either by the SpaceCraft (S/C) or the battery and gets distributed to the PFPS, communication radio, heaters, and deployables through the PDU. The PFPS generates all regulated low-voltage rails using switching regulation synchronized to the LuSEE-Night clock, which ensures self-generated EMI will be confined to well-defined frequency bins. Here, we discussed the unregulated power distribution system architecture and functionality. The PDU engineering and flight modules are developed and characterized to confirm compliance with LuSEE-Night requirements. At the time of writing, all power subsystem components have been integrated into the payload.

47 OTHER INSTRUMENTATION↗

pyflowline: a mesh-independent river network generator for hydrologic models

River networks are crucial in hydrologic and Earth system models. Accurately representing river networks in spatially distributed hydrologic models requires considering the model's spatial discretization and computational mesh. However, current methods of generating river networks for hydrologic models do not typically support unstructured meshes. Unstructured meshes offer numerous advantages over traditional, structured meshes. To overcome this limitation, we developed PyFlowline, a Python package that generates mesh-independent river networks. With PyFlowline, hydrologic modelers can generate conceptual river networks and their topological relationships for both structured and unstructured meshes.

47 OTHER INSTRUMENTATION↗

MEGASIM: Distribution and Detection of Earth Trojan Asteroids

Abstract Using N -body simulation results from the MEGASIM data set, we present spatial distributions of Earth Trojan Asteroids and assess the detectability of the population in current and next-generation ground-based astronomical surveys. Our high-fidelity Earth Trojan Asteroid (ETA) distribution maps show never-before-seen high-resolution spatial features that evolve over timescales up to 1 Gyr. The simulation was synchronized to start times and timelines of two observational astronomy surveys: (1) the Vera C. Rubin Observatory’s Legacy Survey of Space and Time (LSST) and (2) the Zwicky Transient Facility (ZTF). We calculate upper limits for the number of ETAs potentially observable with both the ZTF and LSST surveys. Due to the Yarkovsky Effect, we find no stable ETAs on billion-year timescales likely to be detected by any ETA survey, as no C-type or S-type ETAs (with H < 22 and H < 24, respectively) are likely to be stable on billion-year timescales, and ETAs large enough to remain stable on billion-year timescales are very rare relative to the rest of the ETA population. We find that a twilight ETA survey will not drastically increase the likelihood of individual ETA detection, but it would provide orders of magnitude more observations of select ETA populations. The null detection to date from ZTF restricts the potential ETA population to hundreds of objects larger than 100 m (at H ≈ 22), while a null detection by LSST will further restrict the ETA population to tens of objects larger than 100 m.

79 ASTRONOMY AND ASTROPHYSICS↗

Understanding the impact of the gas diffusion layer structure on catalyst utilization in the PEM water electrolyzer

A multiphysics half-cell model of a polymer electrolyte membrane water electrolyzer (PEMWE) was developed to probe impacts of the detailed 3-dimensional pore structure of the gas diffusion layer (GDL) on performance characteristics. We show that pores in the titanium GDL mesh led to significant underutilization of the catalyst layer (CL), with only 45% of the catalyst effectively utilized. This contradicts the assumption of uniform electron flow across the CL, as shown in graphical abstract (a), as near-zero current was observed near GDL pore regions and the current distribution in CL was influenced by GDL structure, as shown in graphical abstract (b). Instead, oxygen generation was primarily concentrated under the solid titanium regions, diffusing out around the pore walls. High current density peaks were also noted at the GDL-catalyst contact, correlating with degradation hotspots that were directly observed in companion experiments, as shown in graphical abstract (c). Collectively, these findings point to the critical importance of the heterogeneous GDL porous architecture not only for PEMWE efficiency but also for uneven degradation of the CL.

COMSOL↗

Low cost, flexible, and distribution level universal grid analyser platform: designs and implementations

This study presents the designs and implementations of a distribution level open-universal grid analyser (Open-UGA) platform. The proposed Open-UGA platform consists of distribution-level phasor measurement units (PMUs), a standard signal generator, a router, and a server. Firstly, an overall introduction for the software, hardware, and server architectures of the Open-UGA platform is given. To give a detailed design, the software, hardware, server block diagrams, flowcharts, and printed circuit board photo of the Open-UGA platform are presented in detail. Then, four different types of distribution level PMU algorithms are introduced and implemented in the Open-UGA platform to verify the flexibility and reconfigurability. The flowcharts and functionalities of these four UGAs with different PMU algorithms are given as example implementations. Lastly, a performance comparison is conducted with both quantitative and illustrative results.

24 POWER TRANSMISSION AND DISTRIBUTION↗