Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Display Devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Field-Sequential Color Converter

Electronic conversion circuit enables display of signals from field-sequential color-television camera on color video camera. Designed for incorporation into color-television monitor on Space Shuttle, circuit weighs less, takes up less space, and consumes less power than previous conversion equipment. Incorporates state-of-art memory devices, also used in terrestrial stationary or portable closed-circuit television systems.

Studer, Victor J.↗

Pilots' use of a traffic alert and collision-avoidance system (TCAS 2) in simulated air carrier operations. Volume 1: Methodology, summary and conclusions

Pilots' use of and responses to a traffic alert and collision-avoidance system (TCAS 2) in simulated air carrier line operations are described in Volume 1. TCAS 2 monitors the positions of nearby aircraft by means of transponder interrogation, and it commands a climb or descent when conflicting aircraft are projected to reach an unsafe closest point-of-approach within 20 to 25 seconds. A different level of information about the location of other air traffic was presented to each of three groups of flight crews during their execution of eight simulated air carrier flights. A fourth group of pilots flew the same segments without TCAS 2 equipment. Traffic conflicts were generated at intervals during the flights; many of the conflict aircraft were visible to the flight crews. The TCAS equipment successfully ameliorated the seriousness of all conflicts; three of four non-TCAS crews had hazardous encounters. Response times to TCAS maneuver commands did not differ as a function of the amount of information provided, nor did response accuracy. Differences in flight experience did not appear to contribute to the small performance differences observed. Pilots used the displays of conflicting traffic to maneuver to avoid unseen traffic before maneuver advisories were issued by the TCAS equipment. The results indicate: (1) that pilots utilize TCAS effectively within the response times allocated by the TCAS logic, and (2) that TCAS 2 is an effective collision avoidance device. Volume II contains the appendices referenced in Volume I, providing details of the experiment and the results, and the text of two reports written in support of the program.

Chappell, Sheryl L.↗

Pilots' use of a traffic alert and collision-avoidance system (TCAS 2) in simulated air carrier operations. Volume 2: Appendices

Pilots' use of and responses to a traffic alert and collision-avoidance system (TCAS 2) in simulated air carrier line operations are discribed in Volume 1. TCAS 2 monitors the positions of nearby aircraft by means of transponder interrogation, and it commands a climb or descent which conflicting aircraft are projected to reach an unsafe closest point-of-approach within 20 to 25 seconds. A different level of information about the location of other air traffic was presented to each of three groups of flight crews during their execution of eight simulated air carrier flights. A fourth group of pilots flew the same segments without TCAS 2 equipment. Traffic conflicts were generated at intervals during the flights; many of the conflict aircraft were visible to the flight crews. The TCAS equipment successfully ameliorated the seriousness of all conflicts; three of four non-TCAS crews had hazardous encounters. Response times to TCAS maneuver commands did not differ as a function of the amount of information provided, nor did response accuracy. Differences in flight experience did not appear to contribute to the small performance differences observed. Pilots used the displays of conflicting traffic to maneuver to avoid unseen traffic before maneuver advisories were issued by the TCAS equipment. The results indicate: (1) that pilots utilize TCAS effectively within the response times allocated by the TCAS logic, and (2) that TCAS 2 is an effective collision avoidance device. Volume 2 contains the appendices referenced in Volume 1, providing details of the experiment and the results, and the text of two reports written in support of the program.

Chappell, Sheryl L.↗

Design and Conduct of a Windshear Detection Flight Experiment

A description of the design and conduct of a series of flight experiments which tested the performance of candidate windshear detection devices is presented. With prototype windshear sensors installed, a NASA Boeing 737 test aircraft conducted numerous low altitude penetrations of microburst windshear conditions. These tests were preceded by extensive preparations which included piloted simulations, determination of safe operating limits, and the development of unique flight test hardware, displays, and procedures. The test aircraft and more than 50 research and support personnel were deployed to Orlando, Florida, and Denver, Colorado, during June and July 1991 for field testing. Upon receiving a forecast of developing weather activity, the aircraft crew launched and proceeded to the storm location, guided by uplinked ground radar information and voice communications with ground weather personnel. The tests required constant monitoring of numerous factors including aircraft flight parameters, ground obstructions, windshear magnitude, lightning, escape routes, ATC coordination, storm cell development, and others. The flight tests were extremely successful, safely recording more than 25 low altitude microburst windshear and strong gust front approaches and penetrations, along with completing a full test matrix of additional requirements related to windshear sensor performance. Data quality from the tests was excellent and indicates strong potential for airborne remote sensors to accurately predict and warn the flight crew of hazardous windshear conditions with ample time for precautionary crew action.

Flight Testing↗

Protective laser beam viewing device

A protective laser beam viewing system or device including a camera selectively sensitive to laser light wavelengths and a viewing screen receiving images from the laser sensitive camera. According to a preferred embodiment of the invention, the camera is worn on the head of the user or incorporated into a goggle-type viewing display so that it is always aimed at the area of viewing interest to the user and the viewing screen is incorporated into a video display worn as goggles over the eyes of the user.

47 OTHER INSTRUMENTATION↗

Camera selection for real-time in vivo radiation treatment verification systems using Cherenkov imaging

Purpose: To identify achievable camera performance and hardware needs in a clinical Cherenkov imaging system for real-time, in vivo monitoring of the surface beam profile on patients, as novel visual information, documentation, and possible treatment verification for clinicians. Methods: Complementary metal-oxide-semiconductor (CMOS), charge-coupled device (CCD), intensified charge-coupled device (ICCD), and electron multiplying-intensified charge coupled device (EM-ICCD) cameras were investigated to determine Cherenkov imaging performance in a clinical radiotherapy setting, with one emphasis on the maximum supportable frame rate. Where possible, the image intensifier was synchronized using a pulse signal from the Linac in order to image with room lighting conditions comparable to patient treatment scenarios. A solid water phantom irradiated with a 6 MV photon beam was imaged by the cameras to evaluate the maximum frame rate for adequate Cherenkov detection. Adequate detection was defined as an average electron count in the background-subtracted Cherenkov image region of interest in excess of 0.5% (327 counts) of the 16-bit maximum electron count value. Additionally, an ICCD and an EM-ICCD were each used clinically to image two patients undergoing whole-breast radiotherapy to compare clinical advantages and limitations of each system. Results: Intensifier-coupled cameras were required for imaging Cherenkov emission on the phantom surface with ambient room lighting; standalone CMOS and CCD cameras were not viable. The EM-ICCD was able to collect images from a single Linac pulse delivering less than 0.05 cGy of dose at 30 frames/s (fps) and pixel resolution of 512 × 512, compared to an ICCD which was limited to 4.7 fps at 1024 × 1024 resolution. An intensifier with higher quantum efficiency at the entrance photocathode in the red wavelengths [30% quantum efficiency (QE) vs previous 19%] promises at least 8.6 fps at a resolution of 1024 × 1024 and lower monetary cost than the EM-ICCD. Conclusions: The ICCD with an intensifier better optimized for red wavelengths was found to provide the best potential for real-time display (at least 8.6 fps) of radiation dose on the skin during treatment at a resolution of 1024 × 1024.

60 APPLIED LIFE SCIENCES↗

Plasma Panel Based Radiation Detectors

The plasma panel sensor (PPS) is a gaseous micropattern radiation detector under current development. It has many operational and fabrication principles common to plasma display panels (PDPs). It comprises a dense matrix of small, gas plasma discharge cells within a hermetically sealed panel. As in PDPs, it uses non-reactive, intrinsically radiation-hard materials such as glass substrates, refractory metal electrodes, and mostly inert gas mixtures. We are developing these devices primarily as thin, low-mass detectors with gas gaps from a few hundred microns to a few millimeters. The PPS is a high gain, inherently digital device with the potential for fast response times, fine position resolution (< 50 m RMS) and low cost. In this paper we report here on prototype PPS experimental results in detecting betas, protons and cosmic muons, and we extrapolate on the PPS potential for applications including detection of alphas, heavy-ions at low to medium energy, thermal neutrons and X-rays.

Friedman, Dr. Peter S.↗

Processing temperature control of a diketopyrrolopyrrole- alt -thieno[2,3- b ]thiophene polymer for high-mobility thin-film transistors and polymer solar cells with high open-circuit voltages

Here, we synthesized a planar pDPPTTi-OD polymer based on diketopyrrolopyrrole (DPP) and thieno [2,3- b ] thiophene (TTi) and investigated the electrical properties of the pDPPTTi-OD polymer. pDPPTTi-OD films displayed a low optical bandgap of 1.57 eV, and HOMO and LUMO levels of –5.40 and –3.74 eV, respectively. The 150°C-annealed pDPPTTi-OD films showed a high hole mobility of 0.16 cm 2 V –1 s –1 in organic thin-film transistor (OTFT) devices. The photovoltaic properties of polymer solar cells (PSCs) incorporating the pDPPTTi-OD were also measured. A pDPPTTi-OD:PC 71 BM blend film was spin-coated at 25, 70 and 90 °C. High-temperature processing significantly improved the power conversion efficiency of PSCs by effectively reducing the PC 71 BM domain sizes, which improved the miscibility between pDPPTTi-OD and PC 71 BM. Furthermore, this work demonstrated that the TTi moiety is a useful donor building block for high-performance D–A type polymers in OTFTs and PSCs, and that processing temperatures should be controlled to fully realize the materials' beneficial intrinsic properties.

36 MATERIALS SCIENCE↗

π-Extended Porphyrin–Phthalocyanine Heterojunction Devices Exhibiting High Ammonia Sensitivity with a Remarkable Light Effect

π-Extended porphyrins represent an attractive class of organic compounds because of their unique photophysical, optoelectronic, and physicochemical properties. Herein, cross-conjugated (Ace-PQ-Ni) and linear-conjugated (AM6) porphyrins are used to build double-layer heterojunction devices by combining them with a lutetium bisphthalocyanine complex (LuPc 2 ). The heterojunction effect at the porphyrin–phthalocyanine interface plays a key role in the charge transport properties. Both devices exhibit exceptionally high ammonia sensitivity at room temperature and under ambient relative humidity, with limit of detection values of 156 and 115 ppb for Ace-PQ-Ni/LuPc 2 and AM6/LuPc 2 sensors, respectively. Interestingly, the Ace-PQ-Ni/LuPc 2 and AM6/LuPc 2 sensors display opposite effects upon light illumination. While the former sensors show largely decreased ammonia sensitivity under light illumination, the current variation of the latter under ammonia is remarkably enhanced with a multiplication factor of 13 and a limit of detection (LOD) of 83 ppb. Here, the striking difference in their sensing properties upon light illumination is attributed to their different π-conjugation pathways (cross-conjugation versus linear conjugation).

conductometric transducer↗

Moisture-induced autonomous surface potential oscillations for energy harvesting

A variety of autonomous oscillations in nature such as heartbeats and some biochemical reactions have been widely studied and utilized for applications in the fields of bioscience and engineering. Here, we report a unique phenomenon of moisture-induced electrical potential oscillations on polymers, poly([2-(methacryloyloxy)ethyl] dimethyl-(3-sulfopropyl) ammonium hydroxide-co-acrylic acid), during the diffusion of water molecules. Chemical reactions are modeled by kinetic simulations while system dynamic equations and the stability matrix are analyzed to show the chaotic nature of the system which oscillates with hidden attractors to induce the autonomous surface potential oscillation. Using moisture in the ambient environment as the activation source, this self-excited chemoelectrical reaction could have broad influences and usages in surface-reaction based devices and systems. As a proof-of-concept demonstration, an energy harvester is constructed and achieved the continuous energy production for more than 15,000 seconds with an energy density of 16.8 mJ/cm 2 . A 2-Volts output voltage has been produced to power a liquid crystal display toward practical applications with five energy harvesters connected in series.

42 ENGINEERING↗

Giant strain with low cycling degradation in Ta-doped [Bi{sub 1/2}(Na{sub 0.8}K{sub 0.2}){sub 1/2}]TiO{sub 3} lead-free ceramics

Non-textured polycrystalline [Bi{sub 1/2}(Na{sub 0.8}K{sub 0.2}){sub 1/2}](Ti{sub 1−x}Ta{sub x})O{sub 3} ceramics are fabricated and their microstructures and electrical properties are characterized. Transmission electron microscopy reveals the coexistence of the rhombohedral R3c and tetragonal P4bm phases in the form of nanometer-sized domains in [Bi{sub 1/2}(Na{sub 0.8}K{sub 0.2}){sub 1/2}]TiO{sub 3} with low Ta concentration. When the composition is x = 0.015, the electrostrain is found to be highly asymmetric under bipolar fields of ±50 kV/cm. A very large value of 0.62% is observed in this ceramic, corresponding to a large-signal piezoelectric coefficient d{sub 33}* of 1240 pm/V (1120 pm/V under unipolar loading). These values are greater than most previously reported lead-free polycrystalline ceramics and can even be compared with some lead-free piezoelectric single crystals. Additionally, this ceramic displays low cycling degradation; its electrostrain remains above 0.55% even after undergoing 10 000 cycles of ±50 kV/cm bipolar fields at 2 Hz. Therefore, Ta-doped [Bi{sub 1/2}(Na{sub 0.8}K{sub 0.2}){sub 1/2}]TiO{sub 3} ceramics show great potential for large displacement devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Stable White Organic Light-emitting Diodes Enabled by New Materials with Reduced Excited State Lifetime (Final Report)

The Georgia Institute of Technology assembled a multidisciplinary team with complementary expertise in the areas of multi-level molecular simulations (Brédas), chemical synthesis and material characterization (Marder), and device physics and engineering (Kippelen). The team engaged in a two-year integrated theoretical and experimental program to develop blue-emissive layers that can yield simultaneously near 100% internal quantum efficiency (IQE) and short excited-state lifetimes to overcome the existing efficiency vs. stability tradeoff displayed by blue-emitting OLEDs and by WOLEDs, and to demonstrate stable WOLEDs that fulfill or exceed the 2020 target metrics (RDP 2016 section C.1.2) ahead of schedule. In this program, we investigated two general approaches involving the development of wide-bandgap ambipolar hosts with a low ΔEST. Ambipolar host achieved by intermolecular through-space D:A interactions and by intramolecular through-bond interactions between covalently linked D and A segments. Novel hosts were incorporated in to blue-emissive layers (EML) by combining them with suitable fluorescent guest emitters having high quantum yields of emission (Φem) to demonstrate blue-emitting OLEDs with high EQE and low roll-off. This final report describes the most important results achieved during this program

36 MATERIALS SCIENCE↗

Digital image analysis of Landsat data

The paper defines some basic processing functions than can be performed digitally, discusses a variety of computer peripherals including hard copy output devices and television terminals, compares the characteristics of stand-alone image analysis systems, and briefly describes the important features of image processing and geographic information systems software. Several examples are discussed to demonstrate the efficient use of computers through implementation of hard copy image recorders and television display terminals. The commercially available stand-alone image analysis systems include a computer, appropriate peripherals, and sufficient software to perform analysis without other computational support.

Alford, W. L.↗

System for a displaying at a remote station data generated at a central station and for powering the remote station from the central station

A system for displaying at a remote station data generated at a central station and for powering the remote station from the central station is presented. A power signal is generated at the central station and time multiplexed with the data and then transmitted to the remote station. An energy storage device at the remote station is responsive to the transmitted power signal to provide energizing power for the circuits at the remote station during the time interval data is being transmitted to the remote station. Energizing power for the circuits at the remote station is provided by the power signal itself during the time this signal is transmitted. Preferably the energy storage device is a capacitor which is charged by the power signal during the time the power is transmitted and is slightly discharged during the time the data is transmitted to energize the circuits at the remote station.

Perry, J. C.↗

On 32-GHz cryogenically cooled HEMT low-noise amplifiers

The cryogenic noise temperature performance of a two-stage and a three-stage 32 GHz High Electron Mobility Transistor (HEMT) amplifier was evaluated. The amplifiers employ 0.25 micrometer conventional AlGaAs/GaAs HEMT devices, hybrid matching input and output microstrip circuits, and a cryogenically stable dc biasing network. The noise temperature measurements were performed in the frequency range of 31 to 33 GHz over a physical temperature range of 300 K down to 12 K. Across the measurement band, the amplifiers displayed a broadband response, and the noise temperature was observed to decrease by a factor of 10 in cooling from 300 K to 15 K. The lowest noise temperature measured for the two-stage amplifier at 32 GHz was 35 K with an associated gain of 16.5 dB, while the three-stage amplifier measured 39 K with an associated gain of 26 dB. It was further observed that both amplifiers were insensitive to light.

Bautista, J. J.↗

32-GHz cryogenically cooled HEMT low-noise amplifiers

The cryogenic noise temperature performance of a two-stage and a three-stage 32 GHz high electron mobility transistor (HEMT) amplifier was evaluated. The amplifiers employ 0.25 micrometer conventional AlGaAs/GaAs HEMT devices, hybrid matching input and output microstrip circuits, and a cryogenically stable dc biasing network. The noise temperature measurements were performed in the frequency range of 31 to 33 GHz over a physical temperature range of 300 K down to 12 K. Across the measurement band, the amplifiers displayed a broadband response, and the noise temperature was observed to decrease by a factor of 10 in cooling from 300 to 15 K. The lowest noise temperature measured for the two-stage amplifier at 32 GHz was 35 K with an associated gain of 16.5 dB, while the three-stage amplifier measured 39 K with an associated gain of 26 dB. It was further observed that both amplifiers were insensitive to light.

Duh, K. H. George↗

Extreme Temperature Performance of Automotive-Grade Small Signal Bipolar Junction Transistors

Electronics designed for space exploration missions must display efficient and reliable operation under extreme temperature conditions. For example, lunar outposts, Mars rovers and landers, James Webb Space Telescope, Europa orbiter, and deep space probes represent examples of missions where extreme temperatures and thermal cycling are encountered. Switching transistors, small signal as well as power level devices, are widely used in electronic controllers, data instrumentation, and power management and distribution systems. Little is known, however, about their performance in extreme temperature environments beyond their specified operating range; in particular under cryogenic conditions. This report summarizes preliminary results obtained on the evaluation of commercial-off-the-shelf (COTS) automotive-grade NPN small signal transistors over a wide temperature range and thermal cycling. The investigations were carried out to establish a baseline on functionality of these transistors and to determine suitability for use outside their recommended temperature limits.

Thermal Cycling↗

Evaluation of inertial devices for the control of large, flexible, space-based telerobotic arms

Batch simulation studies which show that torque-wheels can reduce the overshoot in abrupt stop commands by 82 percent for a two-link arm are presented. For man-in-the-loop evaluation, a real-time simulator has been developed that samples a hand-controller, solves the nonlinear equations of motion, and graphically displays the resulting motion on a computer workstation. It is shown that, for a single-link arm, a reaction-mass/torque-wheel combination at the payload end can yield a settling time of 3 s for disturbances in the first flexible mode as opposed to 10 s utilizing only a hub motor.

Montgomery, Raymond C.↗