Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Diffraction optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

A Phase Locked High Speed Real-Time Interferometry System for Large Amplitude Unsteady Flows

A high speed phase locked interferometry system has been designed and developed for real-time measurements of the dynamic stall flow over a pitching airfoil. Point diffraction interferograms of incipient flow separation over a sinusoidally oscillating airfoil have been obtained at rates of up to 20 KHz and for free stream Mach numbers of 0.3 and 0.45. The images were recorded on ASA 125 and ASA 400 film using a drum camera. Special electronic timing and synchronizing circuits were developed to trigger the laser light source from the camera, and to initiate acquisition of the interferogram sequence from any desired phase angle of oscillation. The airfoil instantaneous angle of attack data provided by an optical encoder was recorded via a FIFO and in EPROM into a microcomputer. The interferograms have been analyzed using software developed in-house to get quantitative flow density and pressure distributions.

Chandrasekhara, M. S.↗

Optical Vortices with Large Orbital Momentum: Generation and Interference

We demonstrate a method for generation of beams of light with large angular momenta. The method utilizes whispering gallery mode resonators that transform a plane electromagnetic wave into high order Bessel beams. Interference pattern among the beams as well as shadow pictures induced by the beams are observed and studied.

diffraction theory↗

High pressure cosmochemistry applied to major planetary interiors: Experimental studies

Progress is reported on a project to determine the properties and boundaries of high pressure phases of the H2-He-H2O-NH3-CH4 system that are needed to constrain theoretical models of the interiors of the major planets. This project is one of the first attempts to measure phase equilibria in binary fluid-solid systems in diamond anvil cells. Vibrational spectroscopy, direct visual observations, and X-ray diffraction crystallography of materials confined in externally heated cells are the primary experimental probes. Adiabats of these materials are also measured in order to constrain models of heat flow in these bodies and to detect phase transitions by thermal anomalies. Initial efforts involve the NH3-H2O binary. This system is especially relevant to models for surface reconstruction of the icy satellites of Jupiter and Saturn. Thermal analysis experiments were completed for the P-X space, p4GPa:0 or = 0.50, near room temperature. The cryostat, sample handling equipment, and optics needed to extend the optical P-T-X work below room temperature was completed.

Nicol, M. F.↗

Controllable Planar Optical Focusing System

An optical device has a first metasurface. A high-contrast pattern of the first metasurface is operable for modifying, over a first phase profile, a phase front of an incident light beam. A second metasurface, is disposed over a plane parallel to the first metasurface with a second high-contrast pattern and operable for shaping, over a second phase profile, the modified phase front of the incident light beam into a converging spherical phase front. A spacer layer, in which the modified phase front of the incident light beam diffracts, is disposed in a controllably changeable separation between the first and second metasurfaces. Controllably changing the separation between the first and the second metasurfaces by a first distance correspondingly changes the position of the focus point of the converging spherical phase front by a second distance.

Arbabi, Amir↗

The laser elevator - Momentum transfer using an optical resonator

In a conventional laser lightsail system the payload is propelled by the momentum imparted to it by the reflection of a laser beam without the use of any propellant. Because of the unfavorable relationship between energy and momentum in a light beam, these systems are very inefficient. The efficiency can be greatly improved, in principle, if the photons that impact the payload mirror are returned to the source and then redirected back toward the payload again. This system, which recirculates the laser beam, is defined as the 'laser elevator'. The gain of the laser elevator over conventional lightsails depends on the number of times the beam is recycled which is limited by the reflectance of the mirrors used, any losses in the transmission of the beam, and diffraction. Due to the increase pathlength of the folded beam, diffraction losses occur at smaller separations of the payload and the source mirror than for conventional lightsail system. The laser elevator has potential applications in launching to low earth orbit, orbital transfer, and rapid interplanetary delivery of small payloads.

Meyer, Thomas R.↗

Optical design of an imaging spectral radiometer for earth resources applications.

Description of the optics, thermal compensation measures, and calibration procedures for a scanning imaging spectroradiometer to be used in earth resources sensing applications. The spectral range covered extends from 4000 to 8500 A. Two possible modes of operation include (1) a high-spatial-resolution terrestrial survey mode with moderate spectral resolution, and (2) a high-spectral-resolution ocean survey mode with decreased spatial resolution. Two high-aperture f/1.4 objective lenses (providing fields of view of 10 and 25 deg) are interchangeable to give added flexibility in planning experiments with this instrument. A diffraction grating disperses the spectrum which is then scanned by the image sensor.

Harris, T. I.↗

First Results from a Microfocus X-Ray System for Macromolecular Crystallography

The design and performance of a 40 Watt laboratory crystallography system optimized for the structure determination of small protein crystals are described. This system combines a microfocus x-ray generator (40 microns FWHM spot size at a power level of 40 Watts) and a short focal length (F = 2.6 mm) polycapillary collimating optic, and produces a small diameter quasi-parallel x-ray beam. Measurements of x-ray flux, divergence and spectral purity of the resulting x-ray beam are presented. The x-ray flux in a 250 microns diameter aperture produced by the microfocus system is 14.7 times higher .than that from a 3.15 kW rotating anode generator equipped with graphite monochromator. Crystallography data taken with the microfocus system are presented, and indicate that the divergence and spectral purity of the x-ray are sufficient to refine the diffraction data using a standard crystallographic software. Significant additional improvements in flux and beam divergence are possible, and plans for achieving these coals are discussed.

Gubarev, Mikhail↗

Radiative Properties of Cirrus Clouds in the Infrared (8-13 microns) Spectral Region

Atmospheric radiation in the infrared (IR) 8-13 microns spectral region contains a wealth of information that is very useful for the retrieval of ice cloud properties from aircraft or space-borne measurements. To provide the scattering and absorption properties of nonspherical ice crystals that are fundamental to the IR retrieval implementation, we use the finite-difference time domain (FDTD) method to solve for the extinction efficiency, single-scattering albedo, and the asymmetry parameter of the phase function for ice crystals smaller than 40 microns. For particles larger than this size, the improved geometric optics method (IGOM) can be employed to calculate the asymmetry parameter with an acceptable accuracy, provided that we properly account for the inhomogeneity of the refracted wave due to strong absorption inside the ice particle. A combination of the results computed from the two methods provides the asymmetry parameter for the entire practical range of particle sizes between 1 micron and 10000 microns over wavelengths ranging from 8 microns to 13 microns. For the extinction and absorption efficiency calculations, several methods including the IGOM, Mie solution for equivalent spheres (MSFES), and the anomalous diffraction theory (ADT) can lead to a substantial discontinuity in comparison with the FDTD solutions for particle sizes on the order of 40 microns. To overcome this difficulty, we have developed a novel approach called the stretched scattering potential method (SSPM). For the IR 8-13 microns spectral region, we show that SSPM is a more accurate approximation than ADT, MSFES, and IGOM. The SSPM solution can be further refined numerically. Through a combination of the FDTD and SSPM, we have computed the extinction and absorption efficiency for hexagonal ice crystals with sizes ranging from 1 to 10000 microns at 12 wavelengths between 8 and 13 microns Calculations of the cirrus bulk scattering and absorption properties are performed for 30 size distributions obtained from various field campaigns for midlatitude and tropical cirrus cloud systems. Parameterization of these bulk scattering properties is carried out by using second-order polynomial functions for the extinction efficiency and the single-scattering albedo and the power law expression for the asymmetry parameter. We note that the volume-normalized extinction coefficient can be separated into two parts: one is inversely proportional to effective size and is independent of wavelength, and the other is the wavelength-dependent effective extinction efficiency. Unlike conventional parameterization efforts, the present parameterization scheme is more accurate because only the latter part of the volume-normalized extinction coefficient is approximated in terms of an analytical expression. After averaging over size distribution, the single-scattering albedo is shown to decrease with an increase in effective size for wavelengths shorter than 10.0 microns whereas the opposite behavior is observed for longer wavelengths. The variation of the asymmetry parameter as a function of effective size is substantial when the effective size is smaller than 50 microns. For effective sizes larger than 100 microns, the asymmetry parameter approaches its asymptotic value. The results derived in this study can be useful to remote sensing applications involving IR window bands under cirrus cloud conditions.

Yang, Ping↗

Thermal Stability of a 4 Meter Primary Reflector for the Scanning Microwave Limb Sounder

The Scanning Microwave Limb Sounder (SMLS) is a space-borne heterodyne radiometer which will measure pressure, temperature and atmospheric constituents from thermal emission in [180,680] GHz. SMLS, planned for the NRC Decadal Survey's Global Atmospheric Composition Mission, uses a novel toric Cassegrain antenna to perform both elevation and azimuth scanning. This provides better horizontal and temporal resolution and coverage than were possible with elevation-only scanning in the two previous MLS satellite instruments. SMLS is diffraction-limited in the vertical plane but highly astigmatic in the horizontal (beam aspect ratio approx. 1:20). Nadir symmetry ensures that beam shape is nearly invariant over plus or minus 65 deg azimuth. A low-noise receiver FOV is swept over the reflector system by a small azimuth-scanning mirror. We describe the fabrication and thermal-stability test of a composite demonstration primary reflector, having full 4m height and 1/3 the width planned for flight. Using finite-element models of reflectors and structure, we evaluate thermal deformations and optical performance for 4 orbital environments and isothermal soak. We compare deformations with photogrammetric measurements made during soak tests in a chamber. The test temperature range exceeds predicted orbital ranges by large factors, implying in-orbit thermal stability of 0.21 micron rms (root mean square)/C, which meets SMLS requirements.

thermal distortion↗

Evaluation and application of a new interferometry technique for compressible flow research

A new method for obtaining large scale interferograms of flow fields in real time was investigated. The method was based on the point diffraction interferometry technique. The method was modified to accommodate the higher laser power required in recording transonic and supersonic flow fields. Basic tests were conducted in unsteady flows and flows about circulation control airfoils at transonic speeds. It was found that vibration was not a significant factor in the application of the system. In the case of the circulation control airfoils, the real-time viewing allowed the identification of the Coanda jet interaction with the external flow and the shedding of large scale vortices. The method proved to be very sensitive to the optical quality of the wind tunnel windows. The results obtained were compared with earlier interferograms obtained using interferometry. These results were in qualitative agreement.

Bachalo, William D.↗

Controllable Planar Optical Focusing System

An optical device has a first metasurface disposed over a substrate. A high-contrast pattern of the first metasurface is operable for modifying, over a first phase profile, a phase front of an incident light beam. A second metasurface, is disposed over a plane parallel to the first metasurface with a second high-contrast pattern and operable for shaping, over a second phase profile, the modified phase front of the incident light beam into a converging spherical phase front. A spacer layer, in which the modified phase front of the incident light beam diffracts, is disposed in a controllably changeable separation between the first and second metasurfaces. Controllably changing the separation between the first and the second metasurfaces by a first distance correspondingly changes the position of the focus point of the converging spherical phase front by a second distance significantly greater than the first distance.

Arbabi, Amir↗

Mission Concept for the Single Aperture Far-Infrared (SAFIR) Observatory

We have developed a preliminary but comprehensive mission concept for SAFIR, as a 10 m-class far-infrared and submillimeter observatory that would begin development later in this decade to meet the needs outlined above. Its operating temperature (< or = 4K) and instrument complement would be optimized to reach the natural sky confusion limit in the far-infrared with diffraction-limited performance down to at least the atmospheric cutoff, lambda > or approx. 40 microns. This would provide a point source sensitivity improvement of several orders of magnitude over that of the Spitzer Space Telescope (previously SIRTF) or the Herschel Space Observatory. Additionally, it would have an angular resolution 12 times finer than that of Spitzer and three times finer than Herschel. This sensitivity and angular resolution are necessary to perform imaging and spectroscopic studies of individual galaxies in the early universe. We have considered many aspects of the SAFIR mission, including the telescope technology (optical design, materials, and packaging), detector needs and technologies, cooling method and required technology developments, attitude and pointing, power systems, launch vehicle, and mission operations. The most challenging requirements for this mission are operating temperature and aperture size of the telescope, and the development of detector arrays. SAFIR can take advantage of much of the technology under development for JWST, but with much less stringent requirements on optical accuracy.

Benford, Dominic J.↗

Optical measurements of the droplet size distribution in the case of fuel atomization in swirl nozzles and planar airblast diffusers

The theoretical principles of optical methods for the determination of the particle sizes of sprays are considered and aspects of the experimental implementation of these principles are discussed. An experimental device for point-intensity measurements makes use of a helium-neon laser. The cross-sectional area of the laser beam is enlarged with the aid of a lens system to the size of the measurement cross-section. The intensity of the laser light scattered by the spray particles is measured as a function of light direction. Approaches which take into account the total energy of the diffractively scattered light are also discussed and an investigation is conducted regarding the measurement error sources. A description is presented of experimental results obtained in studies of a number of fuel nozzle sprays.

Kayser, A.↗

Laser diffraction particle sizing: Instrument probe volume relocation and elongation

The effective probe volume of laser diffraction particle sizing instruments depends on many instrument parameters. In particular the probe volume axial boundaries and its location along laser beam are essentially defined by the onset of a vignetting effect where light scattered at large angles from small particles misses the transform lens. This vignetting effect results in a probe volume that must be inconveniently close to the lens in order to detect smaller diameter particles (less than 100 micrometers). With the addition of an appropriately designed Keplerian telescope, the probe volume may be relocated and elongated. The theory of operation of this supplemental optical system is described. Design considerations for these supplemental optical systems are described, including recommendations for lens specifications, assembly and use. An image transfer system is described which has been designed for use on a Malvern 2600HSD instrument. Experimental validation of this image transfer system is described.

Anderson, Robert C.↗

An efficient optical architecture for sparsely connected neural networks

An architecture for general-purpose optical neural network processor is presented in which the interconnections and weights are formed by directing coherent beams holographically, thereby making use of the space-bandwidth products of the recording medium for sparsely interconnected networks more efficiently that the commonly used vector-matrix multiplier, since all of the hologram area is in use. An investigation is made of the use of computer-generated holograms recorded on such updatable media as thermoplastic materials, in order to define the interconnections and weights of a neural network processor; attention is given to limits on interconnection densities, diffraction efficiencies, and weighing accuracies possible with such an updatable thin film holographic device.

Hine, Butler P., III↗

Diagnostic Clast-Texture Criteria for Recognition of Impact Deposits

It is difficult to find definitive evidence for impact in the geological record because there are many endogenous geological processes that can produce diamictites similar to those generated by impact ejecta. The classic impact criteria of shock fabrics in certain minerals, and iridium layers, for example, may be either difficult to find, or long-since erased from the impact site (shock fabrics also anneal with time). It is important to be able to recognize impact-generated materials in order to understand earth's crustal development and biological evolution. In future exploration of Mars and other solar-system bodies, recognition of impact materials will be important for elucidating planetary evolution, planetary volatile inventories, and exobiological issues. The cobble depicted is typical of many that have been found in diamictite deposits in Belize generated by the Chicxulub K-T impact event. The pebbles are roughly-hewn in general shape with smoothed corners and edges. Surfaces are almost uniformly frosted (on both protuberances and hollows), but some asperities are glazed. Optical microscopy and thin-section petrographic microscopy reveal the frosting to be only a few microns thick, with a well-defined granular structure; grains are the same size as those composing the bulk of the limestone, but their clearer appearance may represent annealing. One or two adjacent pebble faces are often decorated with striated gouges and closely-spaced hemispherical depressions representing indentation hollows produced by well-rounded impacting clasts of up to 0.5 cm in diameter. Some of the impactors are still embedded in the cobble surface. Non-destructive x-ray diffraction techniques showed the impactors to be of the same mineralogy as the target cobble. We believe this unusual glazing and frosting to be related to the impact event, but this must be reconciled with its survival for over 60 my. since it is composed of one of the most alterable substances, CaCO3. We focus, however, on the non-fractured rounded pebbles that appear to have impacted the larger cobble as a swarm of clasts, probably encountered during ballistic flight. It cannot be defined whether the cobble swept through the pebble cloud, or the pebbles rained upon a slowermoving cobble. Two interesting questions arise: (1) Where did large numbers of such well rounded pebbles come from in the ejecta curtain?, and (2) How did they embed themselves in a nominally brittle rock without suffering damage? Are the well-rounded pebbles crystalline (devitrified) melt spherules? Further investigations are in progress. If the cobble was cold and brittle, impact of well-rounded pebbles would have produced Hertzian fracture patterns (a) in the virtually elastically isotropic cobble target. For penetration depths of about 0.5 of the impactor diameter, the pebbles would require a relative impact velocity sufficient to cause pebble fragmentation and crushing, and the development of a complex Hertzian-Boussinesq fracture field (b) involving deep fracturing and lateral surface spalling (impact velocities > 50 m/s). The existing relationship could only evolve by the impact of cold, hard pebbles into a soft, plastic cobble surface (c). For limestone to have been plastic, it must have been at elevated temperature, but to prevent calcification of the material, the ambient pressure must also have been elevated. This would be possible either in the impact's gas plume, or within the confines of a thin aerodynamically-produced shock bow generated by supersonic ballistic motion of the cobble. In the latter case, it is implied that the cobble swept through the pebbles rather than vice-versa. Although there are high T-P conditions associated with volcanism, such textures have not been reported on volcaniclastic materials, nor from other high T-P environments; e.g., metamorphic (as far as the authors are aware). We propose that this very easily recognizable embedding and indentation surface texture can be used as a diagnostic criterion for the recognition of impact ejecta. The term "peening texture" is suggested, because it is absolutely analogous to the plastic-deformation induced, metal-surface textures generated by ball-bearing bombardment used in engineering metallurgy to work-harden metal surfaces. Additional information is contained in the original (Figures).

Marshall, J. R.↗

Closing the Contrast Gap Between Testbed and Model Prediction with WFIRST-CGI Shaped Pupil Coronagraph

JPL has recently passed an important milestone in its technology development for a proposed NASA WFIRST mission: demonstration of a better than 1x10-8 contrast over broad bandwidth (10%) on both shaped pupil coronagraph (SPC) and hybrid Lyot coronagraph (HLC) testbeds with WFIRST telescope optics. Challenges remain, however, in the technology readiness for the proposed mission. One such is the discrepancy between the achieved contrast on testbeds and their corresponding model predictions. A series of testbed diagnosis and modeling activity were planned and (some) carried out on SPC testbed in order to close the gap. A very useful tool we developed was to analyze the measured testbed Jacobian and compare with its model version that was used to control image plane speckle pattern. The difference between these two is the error in the control Jacobian. When the error, which includes both amplitude and phase, was inserted into a separate prediction model with nominal Jacobian, the model prediction became closely matching the SPC testbed behavior in both contrast floor and contrast convergence speed. This offers a new perspective and is a step closer toward model validation for high contrast coronagraph. Further Jacobian analysis and modeling provided clues to the possible sources for the mismatch: the DM misregistration and the underrepresented testbed optics wavefront error (WFE) and the deformable mirror (DM) setting for correcting this WFE. These analyses suggested that high contrast coronagraph has a tight tolerance in the accuracy of its control Jacobian. Modifications to both testbed control model as well as prediction model are being implemented and future works discussed.

diffraction modeling↗

Beneficiation of ilmenite from lumar analog

The results reported were obtained on a meteoric eucrite sample called Millbillillie Sample no. 173. Optical microscopy studies of the sample showed it to consist of ilmenite, troilite, and transparent gangue. The transparent gangue consisted of feldspar (anorthite), pyroxenes, olivines, and opaques. Troilite was present in minor quantities. Screen assay analyses of the 30, 100, 200, and 400 US mesh screen fractions showed that minor concentration of titanium occurred in the 200 x 400 and -400 mesh screen fractions. Scanning electron microscopy (SEM) studies of the bulk sample showed the presence of a variety of ilmenite grains, ranging from 50 microns down to less than 1 micron without any evidence of liberation. Electron Diffraction Scans (EDS) confirmed the ratio of Fe to Ti in the ilmenite grains. Dry magnetic separation in a Frantz Isodynamic Separator was found to be effective only at sizes finer than 150 microns (100 US mesh) and more so at 200 mesh (74 microns). In each case, dedusting of the sample to remove -400 mesh (-0.037 microns) fines was required. Liberation size was determined to be 200 mesh and finer. The highest grade concentrate assaying 3.45 percent Ti was produced by magnetic separation of the -200 + 400 mesh screen fraction assaying 0.44 Ti (from a -30 mesh sample) at a current setting of 0.35 AMP. This concentrate contained 21.2 percent of the Ti values in the screen fraction with 2.72 weight percent of feed to test. The results can be projected to a sample stage ground to -200 mesh. Magnetic separation of the 200 + 400 mesh (-0.074 + 0.037 microns) should produce a concentrate accounting for 1.41 weight percent of the feed. This concentrate will analyze 3.45 percent Ti and contain 10.3 percent of the Ti values in the feed. By changing the Frantz Magnetic Separator settings, a lower grade concentrate analyzing 0.98 percent Ti can be produced at an increased recovery of 25.4 percent. The concentrate weight will be 11.7 percent of the feed. It must be emphasized that improved grades and recoveries can be obtained with the -400 mesh fines. However, beneficiation of these extremely fine materials is not possible in a practical process scheme.

Ramadorai, G.↗