Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Determinants”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

A Precision Determination of the Effect of Metallicity on Cepheid Absolute Magnitudes in VIJHK Bands from Magellanic Cloud Cepheids

Using high-quality observed period–luminosity ( P – L ) relations in both Magellanic Clouds in the VIJHK s bands and optical and near-infrared Wesenheit indices, we determine the effect of metallicity on Cepheid P – L relations by comparing the relative distance between the LMC and SMC as determined from the Cepheids to the difference in distance between the Clouds that has been derived with very high accuracy from late-type eclipsing binary systems. Within an uncertainty of 3%, which is dominated by the uncertainty on the mean difference in metallicity between the Cepheid populations in the LMC and SMC, we find metallicity effects smaller than 2% in all bands and in the Wesenheit indices, consistent with a zero metallicity effect. This result is valid for the metallicity range from −0.35 dex to −0.75 dex corresponding to the mean [Fe/H] values for classical Cepheids in the LMC and SMC, respectively. Yet most Cepheids in galaxies beyond the Local Group and located in the less crowded outer regions of these galaxies do fall into this metallicity regime, making our result important for applications to determine the distances to spiral galaxies well beyond the Local Group. Our result supports previous findings that indicated a very small metallicity effect on the near-infrared absolute magnitudes of classical Cepheids, and resolves the dispute about the size and sign of the metallicity effect in the optical spectral range. It also resolves one of the most pressing problems in the quest toward a measurement of the Hubble constant with an accuracy of 1% from the Cepheid–supernova Ia method.

79 ASTRONOMY AND ASTROPHYSICS↗

The age of the directly imaged planet host star κ Andromedae determined from interferometric observations

κ Andromedae, an early-type star that hosts a directly imaged low-mass companion, is expected to be oblate due to its rapid rotational velocity (v sin i = ∼162 km s{sup −1}). We observed the star with the CHARA Array’s optical beam combiner, PAVO, measuring its size at multiple orientations and determining its oblateness. The interferometric measurements, combined with photometry and this v sin i value are used to constrain an oblate star model that yields the fundamental properties of the star and finds a rotation speed that is ∼85% of the critical rate and a low inclination of ∼30°. Three modeled properties (the average radius, bolometric luminosity, and equatorial velocity) are compared to MESA evolution models to determine an age and mass for the star. In doing so, we determine an age for the system of 47{sub −40}{sup +27} Myr. Based on this age and previous measurements of the companion’s temperature, the BHAC15 evolution models imply a mass for the companion of 22{sub −9}{sup +8} M {sub J}.

79 ASTRONOMY AND ASTROPHYSICS↗

Can the Distance–Redshift Relation be Determined from Correlations between Luminosities?

We explore whether an independent determination of the distance–redshift relation, and hence cosmological model parameters, can be obtained from the apparent correlations between two different wave-band luminosities or fluxes, as has been claimed in recent works using the X-ray and ultraviolet luminosities and fluxes of quasars. We show that such an independent determination is possible only if the correlation between luminosities is obtained independently of the cosmological model and measured fluxes and redshifts, for example, based on sound theoretical models or unrelated observations. In particular, we show that if the correlation is determined empirically for two luminosities obtained from fluxes and redshifts, then the method suffers from circularity. In the case where the observed correlation between fluxes in very narrow redshift bins is used as a proxy for the luminosity correlation, we show that one is dealing with a pure tautology with no information on distances and cosmological model. We argue that the problem arises because of the incomplete treatment of the correlation, and we use numerical methods with a joint X-ray and ultraviolet quasar data set to demonstrate this shortcoming.

79 ASTRONOMY AND ASTROPHYSICS↗

DETERMINATION OF EMISSIVITY OF MATERIALS.

During the third quarter of the contractual year of Contract NASW-104 for the determination of emissivity of materials, the emittance of nine specimens was measured at temperatures ranging up to 2200F and at pressures averaging 10(exp -8) mm Hg. The materials tested included columbium, columbium with an oxidized surface, molybdenum, graphite varnish on Type 310 stainless steel, stainless steel with an oxidized surface, and platinum black. In the spectral emittance rig, spectral as well as total emittance was measured on three specimens and total emittance only was measured on a fourth. In the total emittance rig, total emittance data was obtained on five specimens. Two of the specimens were endured. Investigations were made concerning the operational characteristics of both rigs in order to eliminate possible sources of error in the data. On the spectral emittance rig, tests were conducted to determine the exact magnitude of any error introduced in the spectral emittance values by beam intermixing resulting from imperfections in the optical system. On the total emittance rig, work was concentrated on the determination of the relative accuracy of the chromel-alumel and platinum-platinum 10% rhodium thermocouples used to measure the temperature of the specimen.

Emission↗

Simple colorimetric method determines uranium in tissue

Simple colorimetric micromethod determines concentrations of uranium in tissue. The method involves dry ashing organic extraction, and colorimetric determination of uranyl ferrocyanide. This uranium determination technique could be used in agricultural research, tracer studies, testing of food products, or medical research.

Doran, D.↗

Determination of the absolute contours of optical flats

Emersons procedure is used to determine true absolute contours of optical flats. Absolute contours of standard flats are determined and a comparison is then made between standard and unknown flats. Contour differences are determined by deviation of Fizeau fringe.

Primak, W.↗

A practical method of determining water current velocities and diffusion coefficients in coastal waters by remote sensing techniques

A simplified procedure is presented for determining water current velocities and diffusion coefficients. Dye drops which form dye patches in the receiving water are made from an aircraft. The changes in position and size of the patches are recorded from two flights over the area. The simplified data processing procedure requires only that the ground coordinates about the dye patches be determined at the time of each flight. With an automatic recording coordinatograph for measuring coordinates and a computer for processing the data, this technique provides a practical method of determining circulation patterns and mixing characteristics of large aquatic systems. This information is useful in assessing the environmental impact of waste water discharges and for industrial plant siting.

James, W. P.↗

Wind tunnel balance system for determination of wind-induced vibrations of a rigid shuttle model in the launch configuration

A wind tunnel balance system was designed to determine the wind-induced vibrations of a space shuttle model. The balance utilizes a flexible sting mounting in conjunction with a geometrically scaled rigid model. Bending and torsional displacements are determined through strain-gauge-instrumented spring bar mechanisms. The natural frequency of the string-model system can be varied continuously throughout the expected scaled frequency range of the shuttle vehicle while a test is in progress by the use of moveable riders on the spring bar mechanism. Through the use of a frequency analyzer, the output can be used to determine troublesome vibrational frequencies. A dimensional analysis of the wind-induced vibration problem is also presented which suggests a test procedure. In addition a computer program for analytical studies of the forced vibration problem is presented.

Source record↗

Satellite height determination using satellite-to-satellite tracking and ground laser systems

The height of the GEOS-C spacecraft was utilized as measured by the onboard radar altimeter, for an improved determination of the earth's gravitational field and for the determination of the variation of the physical surface of the oceans. Two tracking system approaches to accurately determine the spacecraft height (orbit) are described and their results stated. These are satellite-to-satellite tracking (SST) and ground laser tracking (GLT). Height variations can be observed in the dm-regions using SST and in the m-region using present GLT.

Vonbun, F. O.↗

Determination of sounding rocket position and attitude from radar and magnetometer data

The techniques are described that were used to determine the trajectories and orientations of three sounding rockets instrumented to study the aurora. The radar plot board data were fitted to a near earth expansion of the force of gravity to determine the trajectory. Only onboard magnetometer data were used to determine the attitude of the payload with respect to the earth's magnetic field. Computer programs in the FORTRAN language are available which generate the trajectory and attitude parameters.

Pongratz, M.↗

Flight-determined derivatives and dynamic characteristics for the HL-10 lifting body vehicle at subsonic and transonic Mach numbers

The HL-10 lifting body stability and control derivatives were determined by using an analog-matching technique and compared with derivatives obtained from wind-tunnel results. The flight derivatives were determined as a function of angle of attack for a subsonic configuration at Mach 0.7 and for a transonic configuration at Mach 0.7, 0.9, and 1.2. At an angle of attack of 14 deg, data were obtained for a Mach number range from 0.6 to 1.4. The flight and wind-tunnel derivatives were in general agreement, with the possible exception of the longitudinal and lateral damping derivatives. Some differences were noted between the vehicle dynamic response characteristics calculated from flight-determined derivatives and those predicted by the wind-tunnel results. However, the only difference the pilots noted between the response of the vehicle in flight and the response of a simulator programed with wind-tunnel-predicted data was that the damping generally was higher in the flight vehicle.

Strutz, L. W.↗

Peripheral venous scintillation angiocardiography in determination of left ventricular volume in man.

Left ventricular end-diastolic volume was determined by cardiac visualization after peripheral venous injection of a gamma-emitting isotope in 10 patients with organic heart disease. The left ventricular end-diastolic volume measured by the isotope method consistently averaged 9% less than that determined by the X-ray method. The mean difference in left ventricular end-diastolic volume was 21 ml. Excellent correlation between the two methods was observed. It is pointed out that peripheral venous scintillation angiocardiography compares well with left ventriculography in the determination of left ventricular end-diastolic volume in man.

Sullivan, R. W.↗

Evaluation of Jacobian determinants by Monte Carlo methods - Application to the quasiclassical approximation in molecular scattering.

Sampling techniques have been used previously to evaluate Jacobian determinants that occur in classical mechanical descriptions of molecular scattering. These determinants also occur in the quasiclassical approximation. A new technique is described which can be used to evaluate Jacobian determinants which occur in either description. This method is expected to be valuable in the study of reactive scattering using the quasiclassical approximation.

La Budde, R. A.↗

Determination of flow areas for series-parallel compartment venting to satisfy pressure differential requirements.

A unique method for solving the design problem of determining the areas required to meet an imposed pressure differential limit is presented. The associated analytical technique for determining the transient pressure differentials in a multicompartment series-parallel connected system is also presented. In an effort to verify the results obtained by using the analytical methods presented, a test was conducted using a seven compartment system. It was found in the investigations that a computer program based on the analytical model described can determine the pressure, temperature, pressure differentials, and mass flow rates into and out of each compartment at subsonic or sonic velocities.

Kirby, C. E.↗

The use of infrared absorption to determine density of liquid hydrogen.

Experimental evaluation of the use of infrared absorption for determining the density of liquid hydrogen, and discussion of the feasibility of an airborne densitometer based on this concept. The results indicate that infrared absorption of liquid hydrogen is highly sensitive to the density of hydrogen, and, under the operating limitations of the equipment and experimental techniques used, the determined values proved to be repeatable to an accuracy of 2.7%. The desiderata and limitations of an in-flight density-determining device are outlined, and some of the feasibility problems are defined.

Unland, H. D.↗

Evaluation of the pulse-contour method of determining stroke volume in man.

The pulse-contour method for determining stroke volume has been employed as a continuous rapid method of monitoring the cardiovascular status of patients. Twenty-one patients with ischemic heart disease and 21 patients with mitral valve disease were subjected to a variety of hemodynamic interventions. The pulse-contour estimations, using three different formulas derived by Warner, Kouchoukos, and Herd, were compared with indicator-dilution outputs. A comparison of the results of the two methods for determining stroke volume yielded correlation coefficients ranging from 0.59 to 0.84. The better performing Warner formula yielded a coefficient of variation of about 20%. The type of hemodynamic interventions employed did not significantly affect the results using the pulse-contour method. Although the correlation of the pulse-contour and indicator-dilution stroke volumes is high, the coefficient of variation is such that small changes in stroke volume cannot be accurately assessed by the pulse-contour method. However, the simplicity and rapidity of this method compared to determination of cardiac output by Fick or indicator-dilution methods makes it a potentially useful adjunct for monitoring critically ill patients.

Alderman, E. L.↗

The determination of the satellite orbit of Mariner 9.

This paper presents a comprehensive analysis of the Mars orbital phase of the Mariner 9 trajectory as determined from Earth based radio data. Both the method and accuracy of the orbit determination process are reviewed. Analysis is presented to show the effects of Mars gravity model and node in the plane of the sky errors on the accuracy of orbit determination. In addition the long term evolution of the orbit from insertion to date is presented, and is decomposed into effects from the Mars gravity field, n-body perturbations, and solar radiation pressure. Since the orbit period is nearly commensurable with the Mars rotational period, the orbit experiences significant resonance perturbations. The primary perturbation is in-track with a maximum amplitude of 1000 km and a wavelength of 39 revolutions.

Born, G. H.↗

Determining distance to lightning strokes from a single station

Electronic system can rapidly determine location of lightning strikes occurring within 30 km range. Longer distances are also determined, but with reduced accuracy. Studies have shown that lightning bolt emits electromagnetic wavefront; distance to lightning is determined from ratio of magnetic to electric field.

Ruhnke, L. H.↗