Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector Response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

X-ray remote sensing and in-situ spectroscopy for planetary exploration missions and gamma-ray remote sensing and in-situ spectroscopy for planetary exploration missions

Detectors that will be used for planetary missions must have their responses calibrated in a reproducible manner. A calibration facility is being constructed at Schlumberger-Doll Research for gamma and x ray detectors. With this facility the detector response can be determined in an invariant and reproducible fashion. Initial use of the facility is expected for the MARS94 detectors. Work is continuing to better understand the rare earth oxyorthosilicates and to define their characteristics. This will allow a better use of these scintillators for planetary missions. In a survey of scintillating materials two scintillators were identified as promising candidates besides GSO, LSO, and YSO. These are CdWO4 and CsI(Tl). It will be investigated if a detector with a better overall performance can be assembled with various photon converters. Considerable progress was achieved in photomultiplier design. The length of an 1 inch diameter PMT could be reduced from 4.2 to 2.5 inches without performance degradation. This technology is being employed in the gamma ray detector for the NEAR project. A further weight and size reduction of the detector package can be achieved with miniaturized integrated power supplies.

Mahdavi, M.↗

Design and performance of an Automatic Gain Control system for the High Energy X-Ray Timing Experiment

The High Energy X-Ray Timing Experiment (HEXTE), currently under development for the X-Ray Timing Explorer (XTE) mission, employs a closed loop gain control system to attain 0.5 percent stabilization of each of eight-phoswich detector gains. This Automatic Gain Control (AGC) system utilizes a split window discriminator scheme to control the response of each detector pulse height analyzer to gated Am-241 X-ray events at 60 keV. A prototype AGC system has been implemented and tested within the gain perturbation environment expected to be experienced by the HEXTE instrument in flight. The AGC system and test configuration are described. Response, stability and noise characteristics are measured and compared with theoretical predictions. The system is found to be generally suitable for the HEXTE application.

Pelling, Michael R.↗

Understanding the SNO+ Detector

SNO+, a large liquid scintillator experiment, is the successor of the Sudbury Neutrino Observatory (SNO) experiment. The scintillator volume will be loaded with large quantities of 130 Te, an isotope that undergoes double beta decay, in order to search for neutrinoless double beta decay. In addition to this search, SNO+ has a broad physics program due to its sensitivity to solar and supernova neutrinos, as well as reactor and geo anti-neutrinos. SNO+ can also place competitive limits on certain modes of invisible nucleon decay during its first phase. The detector is currently undergoing commissioning in preparation for its first phase, in which the detector is filled with ultra pure water. This will be followed by a pure scintillator phase, and then a Tellurium-loaded scintillator phase to search for neutrinoless double beta decay. Here we present the work done to model detector aging, which was first observed during SNO. The aging was found to reduce the optical response of the detector. We also describe early results from electronics calibration of SNO+.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of quasi-elastic scattering in the NOνA near detector prototype

NOvA is a 14 kTon long-baseline neutrino oscillation experiment currently being installed in the NuMI off-axis neutrino beam produced at Fermilab. A 222 Ton prototype NOνA detector was built and operated in the neutrino beam for over a year to understand the response of the detector and its construction. Muon neutrino interaction data collected in this test are being analyzed to identify quasi-elastic charged-current interactions and measure the behavior of the quasi-elastic muon neutrino cross section.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulation of Particle-Material Interactions

This paper gives an overview of the particle transport theory essentials, the basics of particle-material interaction simulation, physical quantities needed to simulate particle transport and interactions in materials, Monte Carlo simulation flow, response of additive detectors, statistical weights and other techniques to minimize statistical errors. Effects in materials under irradiation, materials response related to component lifetime and performance are considered with a focus on high-energy and high-power accelerator applications. Implementation of simulation of particle-material interactions in the modern Monte Carlo codes along with the code s main features and results of recent benchmarking are described.

43 PARTICLE ACCELERATORS↗

The On-Orbit Calibrations for the Fermi Large Area Telescope

The Large Area Telescope (LAT) on-board the Fermi Gamma-ray Space Telescope began its on-orbit operations on June 23, 2008. Calibrations, defined in a generic sense, correspond to synchronization of trigger signals, optimization of delays for latching data, determination of detector thresholds, gains and responses, evaluation of the perimeter of the South Atlantic Anomaly (SAA), measurements of live time, of absolute time, and internal and spacecraft boresight alignments. Here we describe on-orbit calibration results obtained using known astrophysical sources, galactic cosmic rays, and charge injection into the front-end electronics of each detector. Instrument response functions will be described in a separate publication. This paper demonstrates the stability of calibrations and describes minor changes observed since launch. These results have been used to calibrate the LAT datasets to be publicly released in August 2009.

79 ASTRONOMY AND ASTROPHYSICS↗

A technique for verifying the input response function of neutron time-of-flight scintillation detectors using cosmic rays

An accurate interpretation of DD or DT fusion neutron time-of-flight (nTOF) signals from current mode detectors employed at the Z-facility at Sandia National Laboratories requires that the instrument response functions (IRF’s) be deconvolved from the measured nTOF signals. A calibration facility that produces detectable sub-ns radiation pulses is typically used to measure the IRF of such detectors. This work, however, reports on a simple method that utilizes cosmic radiation to measure the IRF of nTOF detectors, operated in pulse-counting mode. The characterizing metrics reported here are the throughput delay and full-width-at-half-maximum. This simple approach yields consistent IRF results with the same detectors calibrated in 2007 at a LINAC bremsstrahlung accelerator (Idaho State University). In particular, the IRF metrics from these two approaches and their dependence on the photomultipliers bias agree to within a few per cent. This information may thus be used to verify if the IRF for a given nTOF detector employed at Z has changed since its original current-mode calibration and warrants re-measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The (55)Fe X-ray Energy Response of Mercury Cadmium Telluride Near-Infrared Detector Arrays

The accurate determination of a detector's fundamental parameters, including read noise, dark current, and QE, relies on a proper measurement of a detector's conversion gain (e- ADU(exp -1)). Charge coupling effects, such as interpixel capacitance, attenuate photon shot noise and result in an overestimation of conversion gain when implementing the photon transfer technique. An approach involving (55)Fe X-rays provides a potentially straightforward measurement of conversion gain by comparing the observed instrumental counts (ADU) to the known charge (e-) liberated by the X-ray. This technique is already preferred within the CCD community, as the pair production energy for silicon is well established. In contrast, to date the pair production energy is unknown for HgCdTe, a material commonly used for near-infrared detectors. In this paper, we derive a preliminary calibration of the (55)Fe X-ray energy response of HgCdTe using 8 HST WFC3 1.7 micrometers flight grade detectors. Our conversion of the X-ray intensities from counts into electrons implements a technique that restores the 'true' gain via classical propagation of errors. For these detectors, our analysis yields preliminary results of good statistical precision: each Ka event generates 1849 +/- 46 electrons, which corresponds to a pair production energy of 3.21+/-f 0.08 eV. We are continuing to assess potential systematic effects to further refine the accuracy of this result.

Fox, Ori↗

Determination of lunar ilmenite abundances from remotely sensed data

The mineral ilmenite (FeTiO3) was found in abundance in lunar mare soils returned during the Apollo project. Lunar ilmenite often contains greater than 50 weight-percent titanium dioxide (TiO2), and is a primary potential resource for oxygen and other raw materials to supply future lunar bases. Chemical and spectroscopic analysis of the returned lunar soils produced an empirical function that relates the spectral reflectance ratio at 400 and 560 nm to the weight percent abundance of TiO2. This allowed mapping of the lunar TiO2 distribution using telescopic vidicon multispectral imaging from the ground; however, the time variant photometric response of the vidicon detectors produced abundance uncertainties of at least 2 to 5 percent. Since that time, solid-state charge-coupled device (CCD) detector technology capable of much improved photometric response has become available. An investigation of the lunar TiO2 distribution was carried out utilizing groundbased telescopic CCD multispectral imagery and spectroscopy. The work was approached in phases to develop optimum technique based upon initial results. The goal is to achieve the best possible TiO2 abundance maps from the ground as a precursor to lunar orbiter and robotic sample return missions, and to produce a better idea of the peak abundances of TiO2 for benefaction studies. These phases and the results are summarized.

Larson, Stephen M.↗

Development of an advanced antineutrino detector for reactor monitoring

We present the development of a compact antineutrino detector for the purpose of nuclear reactor monitoring, improving upon a previously successful design. Our paper will describe the design improvements of the detector which increases the antineutrino detection efficiency threefold over the previous effort. There are two main design improvements over previous generations of detectors for nuclear reactor monitoring: dual-ended optical readout and single volume detection mass. The dual-ended optical readout eliminates the need for fiducialization and increases the uniformity of the detector's optical response. The containment of the detection mass in a single active volume provides more target mass per detector footprint, a key design criteria for operating within a nuclear power plant. This technology could allow for real-time monitoring of the evolution of a nuclear reactor core, independent of reactor operator declarations of fuel inventories, and may be of interest to the safeguards community.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of the Quasi-Elastic Scattering in the NOvA Detector Prototype

NOvA is a 810 km long base-line neutrino oscillation experiment with two detectors (far 14 KTon and near detector 300 Ton) currently being installed in the NUMI o -axis neutrino beam produced at Fermilab. A 222 Ton prototype NOvA detector (NDOS) was built and operated in the neutrino beam for over a year to understand the response of the detector and its construction. The goal of this thesis is to study the muon neutrino interaction data collected in this test, specifically the identification of quasi-elastic charged-current interactions and measure the behavior of the quasi-elastic muon neutrino cross section.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inexpensive Meter for Total Solar Radiation

Pyranometer containing solar cells measures combined intensity of direct light from Sun and diffuse light from sky. Instrument includes polyethylene dome that diffuses entering light so output of light detectors does not vary significantly with changing angle of Sun during day. Not to be calibrated for response of each detector to Sun angle, and sensor outputs not corrected separately before summed and integrated. Aids in deciding on proper time to harvest crops.

Laue, E. G.↗

Interface Defect Engineering for Improved Graphene-Oxide-Semiconductor Junction Photodetectors

The deeply depleted graphene-oxide-semiconductor (D 2 GOS) junction detector provides an effective architecture for photodetection, enabling direct readout of photogenerated charge. Because of an inherent gain mechanism proportional to graphene’s high mobility (μ), this detector architecture exhibits large responsivities and signal-to-noise ratios (SNR). The ultimate sensitivity of the D2GOS junction detector may be limited, however, because of the generation of dark charge originating from interface states at the semiconductor/dielectric junction. Here, we examine the performance limitations caused by dark charge and demonstrate its mitigation via the creation of low interface defect junctions enabled by surface passivation. The resulting devices exhibit responsivities exceeding 10 000 A/W—a value which is 10× greater than that of analogous devices without the passivating thermal oxide. Finally, with cooling of the detector, the responsivity further increases to over 25 000 A/W, underscoring the impact of surface generation on performance and thus the necessity of minimizing interfacial defects for this class of photodetector.

2D detector↗

MuSIC@Indiana: An effective tool for accurate measurement of fusion with low-intensity radioactive beams

The design, construction, and characterization of the Multi-Sampling Ionization Chamber, MuSIC@Indiana, are described. This detector provides efficient and accurate measurement of the fusion cross-section at near-barrier energies. The response of the detector to low-intensity beams of 17,18 O, 19 F, 23 Na, 24,26 Mg, 27 Al, and 28 Si at E lab 50–60MeV was examined. MuSIC@Indiana was commissioned by measuring the 18 O+ 12 C fusion excitation function for 11 < E cm < 20 MeV using CH 4 gas. Here, a simple, effective analysis cleanly distinguishes proton capture and two-body scattering events from fusion on carbon. With MuSIC@Indiana, measurement of 15 points on the excitation function for a single incident beam energy is achieved. The resulting excitation function is shown to be in good agreement with literature data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-591: Measurement and Monte Carlo Simulation of Stray Neutrons in Passive Scattering Proton Therapy: Needs and Challenges

Purpose: Measure stray radiation inside a passive scattering proton therapy facility, compare values to Monte Carlo (MC) simulations and identify the actual needs and challenges. Methods: Measurements and MC simulations were considered to acknowledge neutron exposure associated with 75 MeV ocular or 180 MeV intracranial passively scattered proton treatments. First, using a specifically-designed high sensitivity Bonner Sphere system, neutron spectra were measured at different positions inside the treatment rooms. Next, measurement-based mapping of neutron ambient dose equivalent was fulfilled using several TEPCs and rem-meters. Finally, photon and neutron organ doses were measured using TLDs, RPLs and PADCs set inside anthropomorphic phantoms (Rando, 1 and 5-years-old CIRS). All measurements were also simulated with MCNPX to investigate the efficiency of MC models in predicting stray neutrons considering different nuclear cross sections and models. Results: Knowledge of the neutron fluence and energy distribution inside a proton therapy room is critical for stray radiation dosimetry. However, as spectrometry unfolding is initiated using a MC guess spectrum and suffers from algorithmic limits a 20% spectrometry uncertainty is expected. H*(10) mapping with TEPCs and rem-meters showed a good agreement between the detectors. Differences within measurement uncertainty (10–15%) were observed and are inherent to the energy, fluence and directional response of each detector. For a typical ocular and intracranial treatment respectively, neutron doses outside the clinical target volume of 0.4 and 11 mGy were measured inside the Rando phantom. Photon doses were 2–10 times lower depending on organs position. High uncertainties (40%) are inherent to TLDs and PADCs measurements due to the need for neutron spectra at detector position. Finally, stray neutrons prediction with MC simulations proved to be extremely dependent on proton beam energy and the used nuclear models and cross sections. Conclusion: This work highlights measurement and simulation limits for ion therapy radiation protection applications.

07 ISOTOPE AND RADIATION SOURCES↗

Effect of the fissile bead's and thermocouple wires’ sizes on the response time of a fission couple

The fission couple is proposed as a fast response miniature neutron detector in the measurement of time dependent energy depositions within the fissile material based on theoretical analysis, but the response time of a fission couple is relatively slow in practice. The time lag originated from heat transfer process was demonstrated to be the dominating factor by theoretical simulations and experimental verification in this paper. The response of a fission couple as a function of the bead size and the thermocouple wires’ sizes are simulated using ANSYS workbench. The decrease of wires’ diameter results in the decrease of response time, and the increase of bead's diameter leads to a slight increase of response time. During a pulse heating transient in the fuel of Chinese Fast Burst Reactor II with a FWHM of 181μs, the time lag originated from heat transfer process is about tens of microseconds for the peaks of the change rate of temperature, and is of the order of milliseconds to achieve 85% of the temperature rise for a typical fission couple with a Φ 1 mm fissile bead and two Φ 0.05 mm thermocouple wires. The results obtained provide foundation for the optimization of fission couples.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

In situ X-ray area detector flat-field correction at an operating photon energy without flat illumination

Flat-field calibration of X-ray area detectors is a challenge due to the inability to generate an X-ray flat-field at the selected photon energy the beamline operates at, which has a strong influence on the measurement behavior of the detector. A method is presented in which a simulated flat-field correction is calculated without flat-field measurements. Instead, a series of quick scattering measurements from an amorphous scatterer is used to calculate a flat-field response. The ability to rapidly obtain a flat-field response allows for recalibration of an X-ray detector as needed without significant expenditure of either time or effort. Area detectors on the beamlines used, such as the Pilatus 2M CdTe, PE XRD1621 and Varex XRD 4343CT, were found to have detector responses that drift slightly over timescales of several weeks or after exposure to high photon flux, suggesting the need to more frequently recalibrate with a new flat-field correction map.

47 OTHER INSTRUMENTATION↗

Prototype Ge:Ga detectors for the NASA-Ames cooled grating spectrometer

The detectors were fabricated from a Ge:Ga wafer from Eagle-Pitcher with a room temperature resistivity of approx. 12ohms cm. The wafer is approximately 2 inches in diameter and 0.061 inches thick. The contact material was ion implanted with Boron using 10 to the 14th power ions/sq cm at 25 Kev and 2 x10 to the 14th power ions/sq cm at 50 Kev. The crystal was then sputter-cleaned and metallized first with sputtered Ti and then sputter Au. In addition to the usual infrared measurements of responsivity and noise, measurements were made of the detectors' response to ionizing radiation.

Houck, J. R.↗