Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Data Movement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Integration of Online Cross-Section Generation Capability with Depletion and Transient Solvers in Griffin

Griffin is a Multiphysics Object-Oriented Simulation Environment (MOOSE)-based reactor multiphysics analysis application jointly developed by Argonne and Idaho National Laboratories under the DOENE Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. In FY25, an online crosssection generation capability based on the Self-Shielding Application Programming Interface (SSAPI) was demonstrated for TRISO-fueled reactor problems under steady-state conditions. This fiscal year, that capability was extended to support depletion and transient multiphysics calculations, enabling high-fidelity analyses that generate self-shielded cross sections on the fly from the actual evolving composition and temperature states rather than from pre-tabulated libraries. For depletion, a two-way coupling was established in which SSAPI computes compact-averaged self-shielded cross sections that the depletion solver then uses to advance the Bateman equations, with the updated compositions returned to SSAPI at each step; the depletion module was refactored to support both library-based and SSAPI-based cross sections, and additional logic was added to track daughter isotopes and to exclude minor isotopes for efficiency. For transient analysis, the SSAPI multigroup library was extended with the kinetics data required for time-dependent calculations, the Improved Quasi-Static (IQS) scheme was coupled with SSAPI, and several supporting capabilities were implemented, including a self-shielding treatment that lets control rods and drums move within a self-shielded model, which had previously been impossible and had ruled out rod- and drum-movement transients with on-the-fly cross sections altogether, a new mixing scheme for delayed-neutron precursor decay constants, a checkpoint-based restart workflow, and performance improvements such as pointwise cross-section interpolation and the bypassing of unnecessary Dancoff factor calculations. The implemented capabilities were verified against Serpent Monte Carlo solutions. For depletion, a prismatic pin-cell problem based on a Next Generation Nuclear Plant (NGNP) Very High Temperature Reactor benchmark showed excellent agreement, with eigenvalue differences within 200 pcm over the entire burnup range (up to 140 MWD/kgU) and fission-product and actinide inventories agreeing to within 0.8% and 2.5%, respectively; a heat-pipe microreactor assembly problem with a much higher fuel loading confirmed the same behavior and quantified the bias introduced when the multigroup equivalence effect is neglected. For transient analysis, a pin-cell problem with a step reactivity insertion and temperature feedback reproduced the analytically expected asymptotic power and showed close agreement between the direct and IQS solutions, and a two-dimensional microreactor core problem with control-drum rotation exercised the new moving-drum self-shielding treatment and demonstrated successful coupling of the online crosssection generation with both the direct and IQS transient methods. The capability was further exercised on a full-core pebble-bed problem, in which Griffin was coupled with the System Analysis Module (SAM) to simulate load-following operation of the gPBR with the Doppler feedback resolved at the TRISO fuel kernel temperature. These developments in Griffin provide a convenient, high-fidelity approach to cross-section generation for advanced thermal reactors with geometrically complex and highly heterogeneous configurations, including TRISO-fueled prismatic and pebble-bed systems, and support steady-state, depletion, and transient multiphysics calculations. They also enable self-shielded cross sections to be evaluated directly at the actual coupled state of the system, thereby establishing a foundation for high-fidelity, fully coupled multiphysics analysis of advanced reactors

Park, H.↗

Electricity Demand Evolution Driven by Storm Motivated Population Movement

Managing the risks posed by climate change to energy production and delivery is a challenge for communities worldwide. Sea Level rise and increased frequency and intensity of natural disasters due to sea surface temperature rise force populations to move locations, resulting in changing patterns of demand for infrastructure services. Thus, Infrastructures will evolve to accommodate new load centers while some parts of the network are underused, and these changes will create emerging vulnerabilities. Combining climate predictions and agent based population movement models shows promise for exploring the universe of these future population distributions and changes in coastal infrastructure configurations. In this work, we created a prototype agent based population distribution model and developed a methodology to establish utility functions that provide insight about new infrastructure vulnerabilities that might result from these patterns. Combining climate and weather data, engineering algorithms and social theory, we use the new Department of Energy (DOE) Connected Infrastructure Dynamics Models (CIDM) to examine electricity demand response to increased temperatures, population relocation in response to extreme cyclonic events, consequent net population changes and new regional patterns in electricity demand. This work suggests that the importance of established evacuation routes that move large populations repeatedly through convergence points as an indicator may be under recognized.

Allen, Melissa R↗

An AI-Based 3D Bat Movement Tracking System at Wind Energy Facilities Using Multi-Thermal Video Cameras

The poster at the 15th Wind Wildlife Research Meeting discusses how to leverage the potential of real-time thermal-imaging methodologies in quantifying nocturnal bat activities at wind turbines, using 3D computer vision techniques within a deep learning framework. This innovation enables the automatic detection and classification of bats, birds, and insects in thermal-imaging videos captured at wind turbine sites, facilitating efficient and accurate data analysis for enhanced understanding and mitigation of bat-wind turbine interactions.

AI↗

An AI-Based 3D Bat Movement Tracking System at Wind Energy Facilities Using Multi-Thermal Video Cameras

The talk at the NAWEA Wind Tech 2024 conference discusses how to leverage the potential of real-time thermal-imaging methodologies in quantifying nocturnal bat activities at wind turbines, using 3D computer vision techniques within a deep learning framework. This innovation enables the automatic detection and classification of bats, birds, and insects in thermal-imaging videos captured at wind turbine sites, facilitating efficient and accurate data analysis for enhanced understanding and mitigation of bat-wind turbine interactions.

AI↗

SU-E-T-258: Development of a New Patient Set-Up Monitoring System Using Force Sensing Resistor (FSR) Sensor for the Radiation Therapy

Purpose: The purpose of this work is to develop a new patient set-up monitoring system using force sensing resistor (FSR) sensors that can confirm pressure of contact surface and evaluate its feasibility. Methods: In this study, we focused on develop the patient set-up monitoring system to compensate for the limitation of existing optical based monitoring system, so the developed system can inform motion in the radiation therapy. The set-up monitoring system was designed consisting of sensor units (FSR sensor), signal conditioning devices (USB cable/interface electronics), a control PC, and a developed analysis software. The sensor unit was made by attaching FSR sensor and dispersing pressure sponge to prevent error which is caused by concentrating specific point. Measured signal from the FSR sensor was sampled to arduino mega 2560 microcontroller, transferred to control PC by using serial communication. The measured data went through normalization process. The normalized data was displayed through the developed graphic user interface (GUI) software. The software was designed to display a single sensor unit intensity (maximum 16 sensors) and display 2D pressure distribution (using 16 sensors) according to the purpose. Results: Changes of pressure value according to motion was confirmed by the developed set-up monitoring system. Very small movement such as little physical change in appearance can be confirmed using a single unit and using 2D pressure distribution. Also, the set-up monitoring system can observe in real time. Conclusion: In this study, we developed the new set-up monitoring system using FSR sensor. Especially, we expect that the new set-up monitoring system is suitable for motion monitoring of blind area that is hard to confirm existing optical system and compensate existing optical based monitoring system. As a further study, an integrated system will be constructed through correlation of existing optical monitoring system. This work was supported by the Industrial R&D program of MOTIE/KEIT. [10048997, Development of the core technology for integrated therapy devices based on real-time MRI guided tumor tracking] and the Mid-career Researcher Program (2014R1A2A1A10050270) through the National Research Foundation of Korea funded by the Ministry of Science, ICT&Future Planning.

60 APPLIED LIFE SCIENCES↗

TU-FG-201-05: Varian MPC as a Statistical Process Control Tool

Purpose: Quality assurance in radiotherapy requires the measurement of various machine parameters to ensure they remain within permitted values over time. In Truebeam release 2.0 the Machine Performance Check (MPC) was released allowing beam output and machine axis movements to be assessed in a single test. We aim to evaluate the Varian Machine Performance Check (MPC) as a tool for Statistical Process Control (SPC). Methods: Varian’s MPC tool was used on three Truebeam and one EDGE linac for a period of approximately one year. MPC was commissioned against independent systems. After this period the data were reviewed to determine whether or not the MPC was useful as a process control tool. Analyses on individual tests were analysed using Shewhart control plots, using Matlab for analysis. Principal component analysis was used to determine if a multivariate model was of any benefit in analysing the data. Results: Control charts were found to be useful to detect beam output changes, worn T-nuts and jaw calibration issues. Upper and lower control limits were defined at the 95% level. Multivariate SPC was performed using Principal Component Analysis. We found little evidence of clustering beyond that which might be naively expected such as beam uniformity and beam output. Whilst this makes multivariate analysis of little use it suggests that each test is giving independent information. Conclusion: The variety of independent parameters tested in MPC makes it a sensitive tool for routine machine QA. We have determined that using control charts in our QA programme would rapidly detect changes in machine performance. The use of control charts allows large quantities of tests to be performed on all linacs without visual inspection of all results. The use of control limits alerts users when data are inconsistent with previous measurements before they become out of specification. A. Carver has received a speaker’s honorarium from Varian.

07 ISOTOPE AND RADIATION SOURCES↗

Integrated Modeling and Decision-Support System for Water Management in the Puget Sound Basin: Snow Caps to White Caps

Final Report for the EPA-sponsored project Snow Caps to White Caps that provides data products and insight for water resource managers to support their predictions and management actions to address future changes in water resources (fresh and marine) in the Puget Sound basin. This report details the efforts of a team of scientists and engineers from Pacific Northwest National Laboratory (PNNL) and the University of Washington (UW) to examine the movement of water in the Snohomish Basin, within the watershed and the estuary, under present and future conditions, using a set of linked numerical models.

54 ENVIRONMENTAL SCIENCES↗

Mesoscale Characterization of Coupled Hydromechanical Behavior of a Fractured Porous Slope in Response to Free Water-Surface Movement

To better understand the role of groundwater-level changes on rock-slope deformation and damage, a carbonate rock slope (30 m x 30 m x 15 m) was extensively instrumented for mesoscale hydraulic and mechanical measurements during water-level changes. The slope is naturally drained by a spring that can be artificially closed or opened by a water gate. In this study, a 2-hour slope-dewatering experiment was analyzed. Changes in fluid pressure and deformation were simultaneously monitored, both at discontinuities and in the intact rock, using short-base extensometers and pressure gauges as well as tiltmeters fixed at the slope surface. Field data were analyzed with different coupled hydromechanical (HM) codes (ROCMAS, FLAC{sup 3D}, and UDEC). Field data indicate that in the faults, a 40 kPa pressure fall occurs in 2 minutes and induces a 0.5 to 31 x 10{sup -6} m normal closure. Pressure fall is slower in the bedding-planes, lasting 120 minutes with no normal deformation. No pressure change or deformation is observed in the intact rock. The slope surface displays a complex tilt towards the interior of the slope, with magnitudes ranging from 0.6 to 15 x 10{sup -6} rad. Close agreement with model for both slope surface and internal measurements is obtained when a high variability in slope-element properties is introduced into the models, with normal stiffnesses of k{sub n{_}faults} = 10{sup -3} x k{sub n{_}bedding-planes} and permeabilities of k{sub h{_}faults} = 10{sup 3} x k{sub h{_}bedding-planes}. A nonlinear correlation between hydraulic and mechanical discontinuity properties is proposed and related to discontinuity damage. A parametric study shows that 90% of slope deformation depends on HM effects in a few highly permeable and highly deformable discontinuities located in the basal, saturated part of the slope while the remaining 10% are related to elasto-plastic deformations in the low-permeability discontinuities induced by complex stress/strain transfers from the high-permeability zones. The periodicity and magnitude of free water-surface movements cause 10 to 20% variations in those local stress/strain accumulations related to the contrasting HM behavior for high and low-permeable elements of the slope. Finally, surface-tilt monitoring coupled with internal localized pressure/deformation measurements appears to be a promising method for characterizing the HM properties and behavior of a slope, and for detecting its progressive destabilization.

54 ENVIRONMENTAL SCIENCES↗

Creeping faults: Good news, bad news?

The motion of the Earth's tectonic plates drive fault slip. Some faults slip in sudden movements, releasing great amounts of energy during large earthquake ruptures, while others slip in steadier movements which release energy more slowly. The latter, known as creeping faults, are believed to be less hazardous but there is mounting evidence that they are more complex than previously thought and can also pose a significant hazard. A recent review by Harris [2017] documents the earthquake potential of creeping faults in shallow continental fault zones from worldwide data. Furthermore, she presents a comprehensive review of prior studies; key insights into when, where, and why fault creep takes place and under which conditions creeping faults may represent high seismic hazard and suggests some directions for future research.

58 GEOSCIENCES↗

Rapid imbibition of water in fractures within unsaturated sedimentary rock

The spontaneous imbibition of water and other liquids into gas-filled fractures in variably-saturated porous media is important in a variety of engineering and geological contexts. However, surprisingly few studies have investigated this phenomenon. In this paper, we present a theoretical framework for predicting the 1-dimensional movement of water into air-filled fractures within a porous medium based on early-time capillary dynamics and spreading over the rough surfaces of fracture faces. The theory permits estimation of sorptivity values for the matrix and fracture zone, as well as a dispersion parameter which quantifies the extent of spreading of the wetting front. Quantitative data on spontaneous imbibition of water in unsaturated Berea sandstone cores were acquired to evaluate the proposed model. The cores with different permeability classes ranging from 50 to 500 mD and were fractured using the Brazilian method. Spontaneous imbibition in the fractured cores was measured by dynamic neutron radiography at the Neutron Imaging Prototype Facility (beam line CG-1D, HFIR), Oak Ridge National Laboratory. Water uptake into both the matrix and the fracture zone exhibited square-root-of-time behavior. The matrix sorptivities ranged from 2.9 to 4.6 mm s -0.5 , and increased linearly as the permeability class increased. The sorptivities of the fracture zones ranged from 17.9 to 27.1 mm s -0.5 , and increased linearly with increasing fracture aperture width. The dispersion coefficients ranged from 23.7 to 66.7 mm 2 s -1 and increased linearly with increasing fracture aperture width and damage zone width. Both theory and observations indicate that fractures can significantly increase spontaneous imbibition in unsaturated sedimentary rock by capillary action and surface spreading on rough fracture faces. Fractures also increase the dispersion of the wetting front. In conclusion, further research is needed to investigate this phenomenon in other natural and engineered porous media.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

February 2020 Bayou Choctaw Subsidence Analysis

Subsidence monitoring is a crucial component to understanding cavern integrity of salt storage caverns. This report looks at the historical and current subsidence monitoring program and includes interpretation of the data from the Bayou Choctaw Strategic Petroleum Reserve site. The current monitoring program consists of an annual elevation survey as well as GPS and tiltmeter instruments above both Cavern 4 and Cavern 20. This year's level and rod survey indicates little subsidence across the site. In addition, the GPS and tiltmeter instruments do not indicate any substantial movement above caverns 4 and 20. As such, there is no reason to indicate any of the caverns at Bayou Choctaw have lost integrity.

02 PETROLEUM↗

Organ Deformation and Dose Coverage in Robotic Respiratory-Tracking Radiotherapy

Purpose: Respiratory motion presents a significant challenge in stereotactic body radiosurgery. Respiratory tracking that follows the translational movement of the internal fiducials minimizes the uncertainties in dose delivery. However, the effect of deformation, defined as any changes in the body and organs relative to the center of fiducials, remains unanswered. This study investigated this problem and a possible solution. Methods and Materials: Dose delivery using a robotic respiratory-tracking system was studied with clinical data. Each treatment plan was designed with the computed tomography scan in the end-expiration phase. The planned beams were applied to the computed tomography scan in end-inspiration following the shift of the fiducials. The dose coverage was compared with the initial plan, and the uncertainty due to the deformation was estimated. A necessary margin from the clinical target volume to the planning target volume was determined to account for this and other sources of uncertainty. Results: We studied 12 lung and 5 upper abdomen lesions. Our results demonstrated that for lung patients with properly implanted fiducials a 3-mm margin is required to compensate for the deformation and a 5-mm margin is required to compensate for all uncertainties. Our results for the upper abdomen tumors were still preliminary but indicated a similar result, although a larger margin might be required. Conclusion: The effect of body deformation was studied. We found that adequate dose coverage for lung tumors can be ensured with proper fiducial placement and a 5-mm planning target volume margin. This approach is more practical and effective than a recent proposal to combine four-dimensional planning with respiratory tracking.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Migratory stopover timing is predicted by breeding latitude, not habitat quality, in a long-distance migratory songbird

The timing of migration can have important survival impacts, as birds must synchronize their movements with favourable environmental conditions to reach their destination. The timing of arrival at and duration of migratory stopover may be largely governed by environmental conditions experienced en route as well as by endogenous factors, but our understanding of these processes is limited. We used light-level geolocators to collect start-to-finish spatio-temporal migration data for a declining aerial insectivore, the Purple Martin ( Progne subis ), that travels seasonally between North and South America. Using data obtained for birds originating from range-wide breeding populations, our objectives were to test intrinsic and extrinsic hypotheses for migration stopover duration as well as to identify important stopover regions during fall migration. We examined whether breeding latitude, fall migration timing, age, sex or habitat quality at stopover sites (measured using Normalized Difference Vegetation Index) influenced the duration of stopovers. We found that most individuals rely on the eastern coast of the Yucatan Peninsula, Honduras, and Nicaragua for stopovers during fall migration, where duration ranged from 1 to 36 days (average 6.8 ± 8.2). Stopovers in these regions were later and of longer duration for more northern breeding populations. Only breeding latitude predicted stopover duration, and not habitat quality at stopovers, lending support to the hypothesis that duration is prescribed by endogenous factors. Lastly, the important core stopover regions we documented could be targeted for conservation efforts, particularly for steeply-declining, more northern breeding populations that have greater stopover duration in these areas.

54 ENVIRONMENTAL SCIENCES↗

Mesoscale Convective Systems in DYAMOND Global Convection‐Permitting Simulations

Abstract This study examines the deep convection populations and mesoscale convective systems (MCSs) simulated in the DYAMOND (DYnamics of the atmospheric general circulation modeled on non‐hydrostatic domains) winter project. A storm tracking algorithm is applied to six DYAMOND simulations and a global high‐resolution satellite cloud and precipitation data set for comparison. The simulated frequencies of tropical deep convection and organized convective systems vary widely among models and regions, although robust MCSs are generally underestimated. The diurnal cycles of MCS initiation and mature stages are well simulated, but the amplitudes are exaggerated over land. Most models capture the observed MCS lifetime, cloud shield area, rainfall volume and movement speed. However, cloud‐top height and convective rainfall intensity are consistently overestimated, and stratiform rainfall area and amount are consistently underestimated. Possible causes for the model differences compared to observations and implications for future model developments are discussed.

58 GEOSCIENCES↗

Development of an x-ray prism for analyzer based imaging systems

Analyzer crystal based imaging techniques such as diffraction enhanced imaging (DEI) and multiple imaging radiography (MIR) utilize the Bragg peak of perfect crystal diffraction to convert angular changes into intensity changes. These x-ray techniques extend the capability of conventional radiography, which derives image contrast from absorption, by providing large intensity changes for small angle changes introduced from the x-ray beam traversing the sample. Objects that have very little absorption contrast may have considerable refraction and ultrasmall angle x-ray scattering contrast improving visualization and extending the utility of x-ray imaging. To improve on the current DEI technique an x-ray prism (XRP) was designed and included in the imaging system. The XRP allows the analyzer crystal to be aligned anywhere on the rocking curve without physically moving the analyzer from the Bragg angle. By using the XRP to set the rocking curve alignment rather than moving the analyzer crystal physically the needed angle sensitivity is changed from submicroradians for direct mechanical movement of the analyzer crystal to tens of milliradians for movement of the XRP angle. However, this improvement in angle positioning comes at the cost of absorption loss in the XRP and depends on the x-ray energy. In addition to using an XRP for crystal alignment it has the potential for scanning quickly through the entire rocking curve. This has the benefit of collecting all the required data for image reconstruction in a single measurement thereby removing some problems with motion artifacts which remain a concern in current DEI/MIR systems especially for living animals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved dosimetry for targeted radionuclide therapy using nonrigid registration on sequential SPECT images

Purpose: Voxel-level and patient-specific 3D dosimetry for targeted radionuclide therapy (TRT) typically involves serial nuclear medicine scans. Misalignment of the images can result in reduced dosimetric accuracy. Since the scans are typically performed over a period of several days, there will be patient movement between scans and possible nonrigid organ deformation. This work aims to implement and evaluate the use of nonrigid image registration on a series of quantitative SPECT (QSPECT) images for TRT dosimetry. Methods: A population of 4D extended cardiac torso phantoms, comprised of three In-111 Zevalin biokinetics models and three anatomical variations, was generated based on the patient data. The authors simulated QSPECT acquisitions at five time points. At each time point, individual organ and whole-body deformation between scans were modeled by translating/rotating organs and the body up to 5°/voxels, keeping ≤5% difference in organ volume. An analytical projector was used to generate realistic noisy projections for a medium energy general purpose collimator. Projections were reconstructed using OS-EM algorithm with geometric collimator detector response, attenuation, and scatter corrections. The QSPECT images were registered using organ-based nonrigid image registration method. The cumulative activity in each voxel was obtained by integrating the activity over time. Dose distribution images were obtained by convolving the cumulative activity images with a Y-90 dose kernel. Dose volume histograms (DVHs) for organs-of-interest were analyzed. Results: After nonrigid registration, the mean differences in organ doses compared to the case without misalignment were improved from (−15.50 ± 5.59)% to (−2.12 ± 1.05)% and (−7.28 ± 2.30)% to (−0.23 ± 0.71)% for the spleen and liver, respectively. For all organs, the cumulative DVHs showed improvement after nonrigid registration and the normalized absolute error of differential DVHs ranged from 6.79% to 22.70% for liver and 26.00% to 39.70% for spleen with different segmentation methods. Conclusions: These results demonstrated that nonrigid registration of sequential QSPECT images is feasible for TRT and improves the accuracy of 3D dosimetry.

60 APPLIED LIFE SCIENCES↗

Wearable Sensors Measure Ankle Joint Changes of Patients with Parkinson’s Disease before and after Acute Levodopa Challenge

Background . Previous studies found levodopa could improve the activity of the ankle joints of patients with Parkinson’s disease (PD). But ankle joint movement is composed of four motion ranges. The specific changes of four motion ranges in PD remain unknown. Objective . The purpose of this study was to decompose the complex ankle joint movement, measure ankle joint changes before and after the acute levodopa challenge test (ALCT), and investigate the effects of these parameters on gait performance. Methods . 29 PD patients and 30 healthy control subjects (HC) completed the Instrumented Stand and Walk (ISAW) test and gait parameters were collected by the JiBuEn gait analysis system. The percentage of improvement of gait data and the UPDRS III in the on-drug condition (ON) were determined with respect to the off-drug condition (OFF). Results . We observed a reduction in the heel strike angle (HS), 3-plantarflexion (3-PF) angle, and 4-dorsiflexion (4-DF) angle of ankle joints. We did not find significant difference in the toe-off angle (TO), 1-plantarflexion (1-PF) angle, and 2-dorsiflexion (2-DF) angle among three groups. Stride length improvement rate was significantly correlated with HS ( r s = 0.616, P < 0.001 ) and 3-PF ( r s = 0.639, P < 0.001 ) improvement rates. The improvement in the sum of rigidity items (UPDRS motor subsection item 22) was also correlated with HS ( r s = 0.389, P = 0.037 ) and 3-PF ( r s = 0.373, P = 0.046 ) improvement rates. Conclusions . Exogenous levodopa supplementation can significantly reduce the rigidity of patients with PD, improve their 3-PF and 4-DF of ankle joint kinematic parameters, and ultimately enhance their gait.

Wu, Zhuang↗