Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

SU-F-P-39: End-To-End Validation of a 6 MV High Dose Rate Photon Beam, Configured for Eclipse AAA Algorithm Using Golden Beam Data, for SBRT Treatments Using RapidArc

Purpose: To use end-to-end testing to validate a 6 MV high dose rate photon beam, configured for Eclipse AAA algorithm using Golden Beam Data (GBD), for SBRT treatments using RapidArc. Methods: Beam data was configured for Varian Eclipse AAA algorithm using the GBD provided by the vendor. Transverse and diagonals dose profiles, PDDs and output factors down to a field size of 2×2 cm2 were measured on a Varian Trilogy Linac and compared with GBD library using 2% 2mm 1D gamma analysis. The MLC transmission factor and dosimetric leaf gap were determined to characterize the MLC in Eclipse. Mechanical and dosimetric tests were performed combining different gantry rotation speeds, dose rates and leaf speeds to evaluate the delivery system performance according to VMAT accuracy requirements. An end-to-end test was implemented planning several SBRT RapidArc treatments on a CIRS 002LFC IMRT Thorax Phantom. The CT scanner calibration curve was acquired and loaded in Eclipse. PTW 31013 ionization chamber was used with Keithley 35617EBS electrometer for absolute point dose measurements in water and lung equivalent inserts. TPS calculated planar dose distributions were compared to those measured using EPID and MapCheck, as an independent verification method. Results were evaluated with gamma criteria of 2% dose difference and 2mm DTA for 95% of points. Results: GBD set vs. measured data passed 2% 2mm 1D gamma analysis even for small fields. Machine performance tests show results are independent of machine delivery configuration, as expected. Absolute point dosimetry comparison resulted within 4% for the worst case scenario in lung. Over 97% of the points evaluated in dose distributions passed gamma index analysis. Conclusion: Eclipse AAA algorithm configuration of the 6 MV high dose rate photon beam using GBD proved efficient. End-to-end test dose calculation results indicate it can be used clinically for SBRT using RapidArc.

60 APPLIED LIFE SCIENCES↗

Calculation of Ambient (H*(10)) and Personal (H p (10)) Dose Equivalent from a 252 Cf Neutron Source

The neutron emission rate from radioisotope neutron sources such as 252 Cf sources can be calibrated by the National Institute of Standards and Technology (NIST) by the manganous sulfite bath method. This calibration method does not compute the dose or dose equivalent rate from the source. Because there is no accepted transfer standard for neutron dose measurements, secondary calibration facilities are responsible for determining their own neutron dose factors. This report describes a neutron source and irradiation apparatus in use at the Pacific Northwest National Laboratory Calibration Facility. The neutron source is a SR-Cf-3000 design 252 Cf neutron source. The neutron source is contained in an aluminum transfer capsule that is used to transport the neutron source between its storage location and it’s irradiation location. During irradiations, the source is located in a transfer tube assembly that consists of two concentric aluminum tubes. When moderated neutrons are desired, the transfer tube assembly is surrounded by a sphere that is filled with D 2 O as a moderating medium. Ambient dose equivalent (H*(10)) and Personal dose equivalent (H p (10)) dose rates and dose conversion factors were calculated for moderated and unmoderated neutron spectra based on the data provided in ICRP Publication 74. The neutron fluence-to-dose-equivalent conversion factors calculated for this report are summarized and compared to published values in Table 47. The calculated coefficients for the unmoderated 252 Cf spectra agree very well with published reference values, within about 2%. The calculated coefficients for the D 2 O moderated 252 Cf spectra, however, differ from published reference values by about 22%. The PNNL coefficients are higher than the published values which could be interpreted to mean that the PNNL D 2 O moderated spectrum is harder, i.e. higher average energy, than the spectrum published by the ISO (2000), which formed the basis for the published coefficients. The D 2 O moderating sphere in use at PNNL contains less D 2 O moderator than did the D 2 O moderating sphere that was used to calculate the ISO spectrum and this is the likely reason for much of the spectral differences. The exact location of the 252 Cf activity in the source encapsulation is unknown. Preliminary measurements, not described in this report, indicate that the activity may be offset from the location that has been assumed in the past. Corrections for the offset are being proposed and will be the subject of another report. This report was written in a calculation package format to help meet various Quality Assurance requirements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dose-responses for mortality from cerebrovascular and heart diseases in atomic bomb survivors: 1950–2003

The scientific community faces important discussions on the validity of the linear no-threshold (LNT) model for radiation-associated cardiovascular diseases at low and moderate doses. In the present study, mortalities from cerebrovascular diseases (CeVD) and heart diseases from the latest data on atomic bomb survivors were analyzed. The analysis was performed with several radio-biologically motivated linear and nonlinear dose–response models. For each detrimental health outcome one set of models was identified that all fitted the data about equally well. This set was used for multi-model inference (MMI), a statistical method of superposing different models to allow risk estimates to be based on several plausible dose–response models rather than just relying on a single model of choice. MMI provides a more accurate determination of the dose response and a more comprehensive characterization of uncertainties. It was found that for CeVD, the dose–response curve from MMI is located below the linear no-threshold model at low and medium doses (0–1.4 Gy). At higher doses MMI predicts a higher risk compared to the LNT model. A sublinear dose–response was also found for heart diseases (0–3 Gy). The analyses provide no conclusive answer to the question whether there is a radiation risk below 0.75 Gy for CeVD and 2.6 Gy for heart diseases. MMI suggests that the dose–response curves for CeVD and heart diseases in the Lifespan Study are sublinear at low and moderate doses. This has relevance for radiotherapy treatment planning and for international radiation protection practices in general.

60 APPLIED LIFE SCIENCES↗

Know your dose: RADDOSE

The program RADDOSE computes the dose absorbed by a macromolecular crystal and here a guide is provided to help to ensure the proper use of the program. In the new version (v.3) described here, modifications to include the energy deposited owing to Compton scattering have been made. The program RADDOSE is widely used to compute the dose absorbed by a macromolecular crystal during an X-ray diffraction experiment. A number of factors affect the absorbed dose, including the incident X-ray flux density, the photon energy and the composition of the macromolecule and of the buffer in the crystal. An experimental dose limit for macromolecular crystallography (MX) of 30 MGy at 100 K has been reported, beyond which the biological information obtained may be compromised. Thus, for the planning of an optimized diffraction experiment the estimation of dose has become an additional tool. A number of approximations were made in the original version of RADDOSE. Recently, the code has been modified in order to take into account fluorescent X-ray escape from the crystal (version 2) and the inclusion of incoherent (Compton) scattering into the dose calculation is now reported (version 3). The Compton cross-section, although negligible at the energies currently commonly used in MX, should be considered in dose calculations for incident energies above 20 keV. Calculations using version 3 of RADDOSE reinforce previous studies that predict a reduction in the absorbed dose when data are collected at higher energies compared with data collected at 12.4 keV. Hence, a longer irradiation lifetime for the sample can be achieved at these higher energies but this is at the cost of lower diffraction intensities. The parameter ‘diffraction-dose efficiency’, which is the diffracted intensity per absorbed dose, is revisited in an attempt to investigate the benefits and pitfalls of data collection using higher and lower energy radiation, particularly for thin crystals.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dosimetric evaluation of sucrose and granulated cane sugar in the therapeutic dose range

Granulated cane sugar has been used as a dosimetric material to report dose in high dose accidental irradiations. The purpose of this study was to assess whether clinical dosimetry is also plausible with such a commonly available material. The behavior of cane sugar was explored with respect to therapeutically relevant radiation quantities (dose, dose rate) and qualities (energy, radiation type) as well as under different temperature conditions. The stability of the signal postirradiation was also measured. Absorbed dose was measured by spectrophotometric readout of a ferrous ammonium sulfate xylenol orange (FX)-sugar solution in 10 cm path length cells. A visible color change was produced as a function of dose when the irradiated sugar samples were dissolved in FX solution (10% dilution by mass). A comparison of the optical absorbance spectra and dose response of cane sugar with analytical grade sucrose was done to establish a benchmark standard from which subsequent dosimetry measurements can be validated. The response of the sugar dosimeter read at 590 nm was found to be linear over the dose range of 100-2000 cGy, independent of energy (6-18 MV) and of the average dose rate (100-500 cGy/min). The readout of sugar samples irradiated with mixed photon and electron fields was also shown to be independent of radiation type (photons and electrons). Sugar temperature (20-40 degree sign C) during irradiation did not affect dose estimates, making it a promising dosimeter for in vivo dosimetry, particularly in cases where the dosimeter must remain in contact with the patient for an extended period of time. Sugar can be used as an integrating dosimeter, since it exhibits no fractionation effects. Granulated cane sugar is cost effective, safe, soft tissue equivalent, and can be used under various experimental conditions, making it a suitable dosimeter for some radiotherapy applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dependence of Yb-169 absorbed dose energy correction factors on self-attenuation in source material and photon buildup in water

Purpose: Absorbed dose energy correction factors, used to convert the absorbed dose deposited in a LiF thermoluminescent dosimeter (TLD) into the clinically relevant absorbed dose to water, were obtained for both spherical volumetric sources and for the model 4140 HDR Yb-169 source. These correction factors have a strong energy dependence below 200 keV; therefore, spectral changes were quantified as Yb-169 photons traveled through both source material (Yb{sub 2}O{sub 3}) and water with the corresponding absorbed dose energy correction factors, f(r,{theta}), calculated as a function of location in a phantom. Methods: Using the MCNP5 Monte Carlo radiation transport simulation program, the Yb-169 spectrum emerging from spherical Yb{sub 2}O{sub 3} sources (density 6.9 g/cm{sup 3}) with radii between 0.2 and 0.9 mm were analyzed and their behavior compared against those for a point-source. The absorbed dose deposited to both LiF and H{sub 2}O materials was analyzed at phantom depths of 0.1-10 cm for each source radius and the absorbed dose energy correction factor calculated as the ratio of the absorbed dose to water to that of LiF. Absorbed dose energy correction factors for the Model 4140 Yb-169 HDR brachytherapy source similarly were obtained and compared against those calculated for the Model M-19 Ir-192 HDR source. Results: The Yb-169 average spectral energy, emerging from Yb{sub 2}O{sub 3} spherical sources 0.2-0.9 mm in radius, was observed to harden from 7% to 29%; as these photons traveled through the water phantom, the photon average energy softened by as much as 28% at a depth of 10 cm. Spectral softening was dependent on the measurement depth in the phantom. Energy correction factors were found to vary both as a function of source radius and phantom depth by as much as 10% for spherical Yb{sub 2}O{sub 3} sources. The Model 4140 Yb-169 energy correction factors depended on both phantom depth and reference angle and were found to vary by more than 10% between depths of 1 and 10 cm and angles of 0 deg. and 180 deg. This was in contrast to that of the Model M-19 Ir-192 source which exhibited approximately 3.5%-4.4% variation in its energy correction factors from phantom depths of 0.5-10 cm. The absorbed dose energy correction factor for the Ir-192 source, on the other hand, was independent of angle to within 1%. Conclusions: The application of a single energy correction factor for Yb-169 TLD based dosimetry would introduce a high degree of measurement uncertainty that may not be reasonable for the clinical characterization of a brachytherapy source; rather, an absorbed dose energy correction function will need to be developed for these sources. This correction function should be specific to each source model, type of TLD used, and to the experimental setup to obtain accurate and precise dosimetric measurements.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-378: Evaluation of Dose-Volume Variability and Parameters Between Prostate IMRT and VMAT Plans

Purpose: This study compared the rectal dose-volume consistency, equivalent uniform dose (EUD) and normal tissue complication probability (NTCP) in prostate intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT). Methods: For forty prostate IMRT and fifty VMAT patients treated using the same dose prescription (78 Gy/39 fraction) and dose-volume criteria in inverse planning optimization, the rectal EUD and NTCP were calculated for each patient. The rectal dose-volume consistency, showing the variability of dose-volume histogram (DVH) among patients, was defined and calculated based on the deviation between the mean and corresponding rectal DVH. Results: From both the prostate IMRT and VMAT plans, the rectal EUD and NTCP were found decreasing with the rectal volume. The decrease rates for the IMRT plans (EUD = 0.47 × 10{sup −3} Gy cm{sup −3} and NTCP = 3.94 × 10{sup −2} % cm{sup −3}) were higher than those for the VMAT (EUD = 0.28 × 10{sup −3} Gy cm{sup −3} and NTCP = 2.61 × 10{sup −2} % cm{sup −3}). In addition, the dependences of the rectal EUD and NTCP on the dose-volume consistency were found very similar between the prostate IMRT and VMAT plans. This shows that both delivery techniques have similar variations of the rectal EUD and NTCP on the dose-volume consistency. Conclusion: Dependences of the dose-volume consistency on the rectal EUD and NTCP were compared between the prostate IMRT and VMAT plans. It is concluded that both rectal EUD and NTCP decreased with an increase of the rectal volume. The variation rates of the rectal EUD and NTCP on the rectal volume were higher for the IMRT plans than VMAT. However, variations of the rectal dose-volume consistency on the rectal EUD and NTCP were found not significant for both delivery techniques.

60 APPLIED LIFE SCIENCES↗

TU-D-201-05: Validation of Treatment Planning Dose Calculations: Experience Working with MPPG 5.a

Purpose: Newly published medical physics practice guideline (MPPG 5.a.) has set the minimum requirements for commissioning and QA of treatment planning dose calculations. We present our experience in the validation of a commercial treatment planning system based on MPPG 5.a. Methods: In addition to tests traditionally performed to commission a model-based dose calculation algorithm, extensive tests were carried out at short and extended SSDs, various depths, oblique gantry angles and off-axis conditions to verify the robustness and limitations of a dose calculation algorithm. A comparison between measured and calculated dose was performed based on validation tests and evaluation criteria recommended by MPPG 5.a. An ion chamber was used for the measurement of dose at points of interest, and diodes were used for photon IMRT/VMAT validations. Dose profiles were measured with a three-dimensional scanning system and calculated in the TPS using a virtual water phantom. Results: Calculated and measured absolute dose profiles were compared at each specified SSD and depth for open fields. The disagreement is easily identifiable with the difference curve. Subtle discrepancy has revealed the limitation of the measurement, e.g., a spike at the high dose region and an asymmetrical penumbra observed on the tests with an oblique MLC beam. The excellent results we had (> 98% pass rate on 3%/3mm gamma index) on the end-to-end tests for both IMRT and VMAT are attributed to the quality beam data and the good understanding of the modeling. The limitation of the model and the uncertainty of measurement were considered when comparing the results. Conclusion: The extensive tests recommended by the MPPG encourage us to understand the accuracy and limitations of a dose algorithm as well as the uncertainty of measurement. Our experience has shown how the suggested tests can be performed effectively to validate dose calculation models.

60 APPLIED LIFE SCIENCES↗

Dose optimization of an adjuvanted peptide-based personalized neoantigen melanoma vaccine

The advancements in next-generation sequencing have made it possible to effectively detect somatic mutations, which has led to the development of personalized neoantigen cancer vaccines that are tailored to the unique variants found in a patient’s cancer. These vaccines can provide significant clinical benefit by leveraging the patient’s immune response to eliminate malignant cells. However, determining the optimal vaccine dose for each patient is a challenge due to the heterogeneity of tumors. To address this challenge, we formulate a mathematical dose optimization problem based on a previous mathematical model that encompasses the immune response cascade produced by the vaccine in a patient. We propose an optimization approach to identify the optimal personalized vaccine doses, considering a fixed vaccination schedule, while simultaneously minimizing the overall number of tumor and activated T cells. To validate our approach, we perform in silico experiments on six real-world clinical trial patients with advanced melanoma. We compare the results of applying an optimal vaccine dose to those of a suboptimal dose (the dose used in the clinical trial and its deviations). Our simulations reveal that an optimal vaccine regimen of higher initial doses and lower final doses may lead to a reduction in tumor size for certain patients. Our mathematical dose optimization offers a promising approach to determining an optimal vaccine dose for each patient and improving clinical outcomes.

59 BASIC BIOLOGICAL SCIENCES↗

Harderian Gland Tumorigenesis: Low-Dose and LET Response

Increased cancer risk remains a primary concern for travel into deep space and may preclude manned missions to Mars due to large uncertainties that currently exist in estimating cancer risk from the spectrum of radiations found in space with the very limited available human epidemiological radiation-induced cancer data. Existing data on human risk of cancer from X-ray and gamma-ray exposure must be scaled to the many types and fluences of radiations found in space using radiation quality factors and dose-rate modification factors, and assuming linearity of response since the shapes of the dose responses at low doses below 100 mSv are unknown. The goal of this work was to reduce uncertainties in the relative biological effect (RBE) and linear energy transfer (LET) relationship for space-relevant doses of charged-particle radiation-induced carcinogenesis. The historical data from the studies of Fry et al. and Alpen et al. for Harderian gland (HG) tumors in the female CB6F1 strain of mouse represent the most complete set of experimental observations, including dose dependence, available on a specific radiation-induced tumor in an experimental animal using heavy ion beams that are found in the cosmic radiation spectrum. However, these data lack complete information on low-dose responses below 0.1 Gy, and for chronic low-dose-rate exposures, and there are gaps in the LET region between 25 and 190 keV/μm. In this study, we used the historical HG tumorigenesis data as reference, and obtained HG tumor data for 260 MeV/u silicon (LET ~70 keV/μm) and 1,000 MeV/u titanium (LET ~100 keV/μm) to fill existing gaps of data in this LET range to improve our understanding of the dose-response curve at low doses, to test for deviations from linearity and to provide RBE estimates. Animals were also exposed to five daily fractions of 0.026 or 0.052 Gy of 1,000 MeV/u titanium ions to simulate chronic exposure, and HG tumorigenesis from this fractionated study were compared to the results from single 0.13 or 0.26 Gy acute titanium exposures. Theoretical modeling of the data show that a nontargeted effect model provides a better fit than the targeted effect model, providing important information at space-relevant doses of heavy ions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Characterization of the role of Fhit in maintenance of genomic integrity following low dose radiation, in vivo and in vitro

The major goal of this study is to determine the effects of the Fhit pathway on low dose (< 0.1 Gy) ionizing radiation (IR)-induced genetic instability. Reduction of Fhit protein expression is observed in most solid tumors particularly in those tumors resulting from exposure to environmental carcinogens. Therefore, characterization of the role of the Fhit-dependent pathway in preventing low dose IR-induced genetic instability will provide useful parameters for evaluating the low dose IR-induced risk of mutagenesis and carcinogenesis. We pursued 3 specific aims to study our hypothesis that the Fhit-dependent pathways maintain genomic integrity through adjusting checkpoint response and repair genes expression following low dose IR. Aim 1: Determine whether Fhit interaction with RPA is necessary for Fhit to affect the cellular response to low dose IR. We combined the approaches of in vitro (GST pull-down and site-directed mutagenesis) and in vivo (observing the co-localization and immunoprecipitation of Fhit and RPA in Fhit knock out mouse cells transfected with mutant Fhit which has lost ability to interact with RPA in vitro). Aim 2: Determine the role of genes whose expression is affected by Fhit in low dose irradiated cells. We analyzed the distinct signature of gene expression in low dose irradiated Fhit-/- cells compared with Fhit+/+ cells by combining microarray, gene transfection and siRNA approaches. Aim 3: Determine the role of Fhit in genetic susceptibility to low dose IR in vivo. We compared the gene mutation frequency and the fragile site stability in the cells isolated from the Fhit+/+ and Fhit-/- mice at 1.5 years following low dose IR. These results determine the role of the Fhit-dependent pathway in maintaining genomic integrity in vitro and in vivo, which provide a basis for choosing surrogate markers in the Fhit-dependent pathway to evaluate low dose IR-induced risk of mutagenesis and carcinogenesis.

59 BASIC BIOLOGICAL SCIENCES↗

Validation of Gamma Dose Rate Calculation Methodology using the Morris and Turkey Point Measurements

The ability to accurately predict the dose rates from the spent nuclear fuel assembly is very important for determining whether the used nuclear fuel is self-guarded and self-protected. Studies have shown that the direct numerical calculations of the dose rates gave a much lower value than a typical reference. This report summarizes the benchmark studies performed to evaluate the numerical methodologies used in calculating the gamma dose rates of the spent nuclear fuel assemblies. The Morris and Turkey Point experimental data for dose rates measured through air were used in the analyses. Numerical simulations of the gamma dose rate measurements included the fuel depletion analysis of the fuel assembly as well as its structural materials irradiated inside the reactor core, the radioisotopes decay, and photon transport simulations to calculate the gamma dose rates. The different factors which affect the calculated gamma dose rates were addressed. The calculated results were compared with the measured gamma dose rates. Good agreement was obtained when the detectors were placed at the middle of the fuel assembly region. The deviations of the calculated dose rates became larger when the measurements were performed at the top or bottom fuel assemblies. In these benchmark studies, the spent nuclear fuel assemblies were all PWR assemblies and had fuel burnup around 25 MWd/kg to 40 MWd/kg. Its cooling time before the measurements was around 1.8 years to 7 years. The used nuclear fuel assembly is usually self-protected while discharged from the core. Its radioactivity decreases and after a few tens of years it may fall down below the current threshold of 100 r/h. Future validation work is necessary in order to better evaluate the numerically calculated gamma dose rates with experiments performed for other types of fuel assemblies and for fuel assemblies with higher burnup and/or longer cooling times.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of the role of Fhit in maintenance of genomic integrity following low dose radiation, in vivo and in vitro

The major goal of this study is to determine the effects of the Fhit pathway on low dose ({le} 0.1 Gy) ionizing radiation (IR)-induced genetic instability. Reduction of Fhit protein expression is observed in most solid tumors particularly in those tumors resulting from exposure to environmental carcinogens. Therefore, characterization of the role of the Fhit-dependent pathway in preventing low dose IR-induced genetic instability will provide useful parameters for evaluating the low dose IR-induced risk of mutagenesis and carcinogenesis. We pursued 3 specific aims to study our hypothesis that the Fhit-dependent pathways maintain genomic integrity through adjusting checkpoint response and repair genes expression following low dose IR. Aim 1: Determine whether Fhit interaction with RPA is necessary for Fhit to affect the cellular response to low dose IR. We combined the approaches of in vitro (GST pull-down and site-directed mutagenesis) and in vivo (observing the co-localization and immunoprecipitation of Fhit and RPA in Fhit knock out mouse cells transfected with mutant Fhit which has lost ability to interact with RPA in vitro). Aim 2: Determine the role of genes whose expression is affected by Fhit in low dose irradiated cells. We analyzed the distinct signature of gene expression in low dose irradiated Fhit-/- cells compared with Fhit+/+ cells by combining microarray, gene transfection and siRNA approaches. Aim 3: Determine the role of Fhit in genetic susceptibility to low dose IR in vivo. We compared the gene mutation frequency and the fragile site stability in the cells isolated from the Fhit+/+ and Fhit-/- mice at 1.5 years following low dose IR. These results determine the role of the Fhit-dependent pathway in maintaining genomic integrity in vitro and in vivo, which provide a basis for choosing surrogate markers in the Fhit-dependent pathway to evaluate low dose IR-induced risk of mutagenesis and carcinogenesis.

59 BASIC BIOLOGICAL SCIENCES↗

Uterine Artery Embolization for Leiomyomata: Optimization of the Radiation Dose to the Patient Using a Flat-Panel Detector Angiographic Suite

The purpose of this study was to assess the ability of low-dose/low-frame fluoroscopy/angiography with a flat-panel detector angiographic suite to reduce the dose delivered to patients during uterine fibroid embolization (UFE). A two-step prospective dosimetric study was conducted, with a flat-panel detector angiography suite (Siemens Axiom Artis) integrating automatic exposure control (AEC), during 20 consecutive UFEs. Patient dosimetry was performed using calibrated thermoluminescent dosimeters placed on the lower posterior pelvis skin. The first step (10 patients; group A) consisted in UFE (bilateral embolization, calibrated microspheres) performed using the following parameters: standard fluoroscopy (15 pulses/s) and angiography (3 frames/s). The second step (next consecutive 10 patients; group B) used low-dose/low-frame fluoroscopy (7.5 pulses/s for catheterization and 3 pulses/s for embolization) and angiography (1 frame/s). We also recorded the total dose-area product (DAP) delivered to the patient and the fluoroscopy time as reported by the manufacturer's dosimetry report. The mean peak skin dose decreased from 2.4 {+-} 1.3 to 0.4 {+-} 0.3 Gy (P = 0.001) for groups A and B, respectively. The DAP values decreased from 43,113 {+-} 27,207 {mu}Gy m{sup 2} for group A to 9,515 {+-} 4,520 {mu}Gy m{sup 2} for group B (P = 0.003). The dose to ovaries and uterus decreased from 378 {+-} 238 mGy (group A) to 83 {+-} 41 mGy (group B) and from 388 {+-} 246 mGy (group A) to 85 {+-} 39 mGy (group B), respectively. Effective doses decreased from 112 {+-} 71 mSv (group A) to 24 {+-} 12 mSv (group B) (P = 0.003). In conclusion, the use of low-dose/low-frame fluoroscopy/angiography, based on a good understanding of the AEC system and also on the technique during uterine fibroid embolization, allows a significant decrease in the dose exposure to the patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Organ and effective dose rate coefficients for submersion exposure in occupational settings

External dose coefficients for environmental exposure scenarios are often computed using assumption on infinite or semi-infinite radiation sources. For example, in the case of a person standing on contaminated ground, the source is assumed to be distributed at a given depth (or between various depths) and extending outwards to an essentially infinite distance. In the case of exposure to contaminated air, the person is modeled as standing within a cloud of infinite, or semi-infinite, source distribution. However, these scenarios do not mimic common workplace environments where scatter off walls and ceilings may significantly alter the energy spectrum and dose coefficients. In this study, dose rate coefficients were calculated using the International Commission on Radiological Protection (ICRP) reference voxel phantoms positioned in rooms of three sizes representing an office, laboratory, and warehouse. For each room size calculations using the reference phantoms were performed for photons, electrons, and positrons as the source particles to derive mono-energetic dose rate coefficients. Since the voxel phantoms lack the resolution to perform dose calculations at the sensitive depth for the skin, a mathematical phantom was developed and calculations were performed in each room size with the three source particle types. Coefficients for the noble gas radionuclides of ICRP Publication 107 (e.g., Ne, Ar, Kr, Xe, and Rn) were generated by folding the corresponding photon, electron, and positron emissions over the mono-energetic dose rate coefficients. Finally, results indicate that the smaller room sizes have a significant impact on the dose rate per unit air concentration compared to the semi-infinite cloud case. For example, for Kr-85 the warehouse dose rate coefficient is 7% higher than the office dose rate coefficient while it is 71% higher for Xe-133.

61 RADIATION PROTECTION AND DOSIMETRY↗

Alteration of cytokine profiles in mice exposed to chronic low-dose ionizing radiation

While a high-dose of ionizing radiation is generally harmful and causes damage to living organisms, a low-dose of radiation has been shown to be beneficial in a variety of animal models. To understand the basis for the effect of low-dose radiation in vivo, we examined the cellular and immunological changes evoked in mice exposed to low-dose radiation at very low (0.7 mGy/h) and low (3.95 mGy/h) dose rate for the total dose of 0.2 and 2 Gy, respectively. Mice exposed to low-dose radiation, either at very low- or low-dose rate, demonstrated normal range of body weight and complete blood counts. Likewise, the number and percentage of peripheral lymphocyte populations, CD4{sup +} T, CD8{sup +} T, B, or NK cells, stayed unchanged following irradiation. Nonetheless, the sera from these mice exhibited elevated levels of IL-3, IL-4, leptin, MCP-1, MCP-5, MIP-1{alpha}, thrombopoietin, and VEGF along with slight reduction of IL-12p70, IL-13, IL-17, and IFN-{gamma}. This pattern of cytokine release suggests the stimulation of innate immunity facilitating myeloid differentiation and activation while suppressing pro-inflammatory responses and promoting differentiation of naive T cells into T-helper 2, not T-helper 1, types. Collectively, our data highlight the subtle changes of cytokine milieu by chronic low-dose {gamma}-radiation, which may be associated with the functional benefits observed in various experimental models.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Universal Survival Curve and Single Fraction Equivalent Dose: Useful Tools in Understanding Potency of Ablative Radiotherapy

Purpose: Overprediction of the potency and toxicity of high-dose ablative radiotherapy such as stereotactic body radiotherapy (SBRT) by the linear quadratic (LQ) model led to many clinicians' hesitating to adopt this efficacious and well-tolerated therapeutic option. The aim of this study was to offer an alternative method of analyzing the effect of SBRT by constructing a universal survival curve (USC) that provides superior approximation of the experimentally measured survival curves in the ablative, high-dose range without losing the strengths of the LQ model around the shoulder. Methods and Materials: The USC was constructed by hybridizing two classic radiobiologic models: the LQ model and the multitarget model. We have assumed that the LQ model gives a good description for conventionally fractionated radiotherapy (CFRT) for the dose to the shoulder. For ablative doses beyond the shoulder, the survival curve is better described as a straight line as predicted by the multitarget model. The USC smoothly interpolates from a parabola predicted by the LQ model to the terminal asymptote of the multitarget model in the high-dose region. From the USC, we derived two equivalence functions, the biologically effective dose and the single fraction equivalent dose for both CFRT and SBRT. Results: The validity of the USC was tested by using previously published parameters of the LQ and multitarget models for non-small-cell lung cancer cell lines. A comparison of the goodness-of-fit of the LQ and USC models was made to a high-dose survival curve of the H460 non-small-cell lung cancer cell line. Conclusion: The USC can be used to compare the dose fractionation schemes of both CFRT and SBRT. The USC provides an empirically and a clinically well-justified rationale for SBRT while preserving the strengths of the LQ model for CFRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel Method for the Evaluation of Uncertainty in Dose-Volume Histogram Computation

Purpose: Dose-volume histograms (DVHs) are a useful tool in state-of-the-art radiotherapy treatment planning, and it is essential to recognize their limitations. Even after a specific dose-calculation model is optimized, dose distributions computed by using treatment-planning systems are affected by several sources of uncertainty, such as algorithm limitations, measurement uncertainty in the data used to model the beam, and residual differences between measured and computed dose. This report presents a novel method to take them into account. Methods and Materials: To take into account the effect of associated uncertainties, a probabilistic approach using a new kind of histogram, a dose-expected volume histogram, is introduced. The expected value of the volume in the region of interest receiving an absorbed dose equal to or greater than a certain value is found by using the probability distribution of the dose at each point. A rectangular probability distribution is assumed for this point dose, and a formulation that accounts for uncertainties associated with point dose is presented for practical computations. Results: This method is applied to a set of DVHs for different regions of interest, including 6 brain patients, 8 lung patients, 8 pelvis patients, and 6 prostate patients planned for intensity-modulated radiation therapy. Conclusions: Results show a greater effect on planning target volume coverage than in organs at risk. In cases of steep DVH gradients, such as planning target volumes, this new method shows the largest differences with the corresponding DVH; thus, the effect of the uncertainty is larger.

62 RADIOLOGY AND NUCLEAR MEDICINE↗