Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cryogenic electronic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Development of a Cryogen-Free Continuous ADR for the Constellation-X Mission

Constellation-X is a multi-satellite x-ray astronomy mission presently being planned for launch in the 2010 time frame. Each of 4 identical satellites will contain a telescope and instruments for imaging and spectroscopic analysis of both hard and soft x-rays. The X- ray Microcalorimeter Spectrometer (XMS) instrument will use arrays of microcalorimeters to detect X-rays with energies from 0.2 to 6 keV. The technologies under development for this instrument include Transition-Edge Sensors (TES) with multiplexed SQUID readouts and NTD-Ge detectors with JFET readouts. Both will be operated at temperatures in the 50-60 mK range and both have a projected cooling power requirement of approximately 5 microwatts. In addition, in order to meet the lifetime requirement of 6 years (with a goal of 10 years), a mechanical cryocooler will be used to provide a heat sink for the low temperature cooler. The required performance is 20 mW at 6 K, with a goal of 4 K operation. In this paper we present the development status of an adiabatic demagnetization refigerator (ADR) that meets the cooling requirements of the X M S instrument. At present we have demonstrated a 4-stage ADR that operates continuously at 50 mK using a 4.2 K helium bath as a heat sink. The cooling power is 21 microwatts at 100 mK and 6 microwatts at 50 mK. Its efficiency when operating at 50 mK is 1 1 % of Carnot (accounting for all dissipation at 4.2 K and below, but not including power dissipation in the room temperature electronics), but this is expected to rise to 25% in the next generation system in which active gas-gap heat switches are replaced with passive devices. This will reduce the peak heat rejection rate of the ADR to less than 7 mW at 6 K. Details of the ADR s design and operation, as well as the development program leading up to a flight-qualified instrument, will be discussed.

Shirron, Peter↗

Development of a large-mass, low-threshold detector system with simultaneous measurements of athermal phonons and scintillation light

For this work, we have combined two low-threshold detector technologies to develop a large-mass, low-threshold detector system that simultaneously measures the athermal phonons in a sapphire detector while an adjacent silicon high-voltage detector detects the scintillation light from the sapphire detector. This detector system could provide event-by-event discrimination between electron and nuclear events due to the difference in their scintillation light yield. While such systems with simultaneous phonon and light detection have been demonstrated earlier with smaller detectors, our system is designed to provide a large detector mass with high amplification for the limited scintillation light. Future work will focus on at least an order of magnitude improvement in the light collection efficiency by having a highly reflective detector housing and custom phonon mask design to maximize light collection by the silicon high-voltage detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Unraveling the CO Oxidation Mechanism over Highly Dispersed Pt Single Atom on Anatase TiO 2 (101)

Catalysts with noble metals deposited as single atoms on metal oxide supports have recently been studied extensively due to their maximized metal utilization and potential for performing difficult chemical conversions owing to their unique electronic properties. Understanding of the reaction mechanisms on supported single-metal atoms is still limited but is highly important for designing more efficient catalysts. In this study, we report the complexity of the CO oxidation reaction mechanism on Pt single atoms supported on anatase TiO 2 (Pt SA /a-TiO 2 ) by coupling density functional theory (DFT) calculations and microkinetic analysis with kinetic measurements, in situ/operando infrared, and X-ray absorption spectroscopies. Starting from the adsorbed Pt SA occupying an O vacancy induced by reductive pretreatment, we show that CO oxidation follows a complex mechanism consisting of initiation steps to reorganize the active site and multibranch reactive cycles, with the Pt SA /a-TiO 2 catalyst not returning to its initial configuration. The initiation step consists of CO and O 2 adsorption healing the O vacancy, followed by CO oxidation using gas-phase CO to form Pt(CO). The reactive cycle alternates O 2 adsorption and dissociation to oxidize the catalyst to Pt(O)(O)(CO) and branching pathways of competing Langmuir–Hinshelwood (LH)- or Eley–Rideal (ER)-type CO oxidation steps to reduce it again to Pt(CO). In situ/operando infrared experiments, including cryogenic CO adsorption and isotopic CO exchange, confirm the combined involvement of strongly adsorbed CO and gas-phase CO in an Eley–Rideal step along the reaction cycle. Microkinetic modeling shows that Pt single atoms are present in a mixture of Pt(CO), Pt(CO)(O 2 ), Pt(O)(CO)(O 2 ), and Pt(CO)(CO 3 ) structures as the main intermediates during steady-state CO oxidation, all having the C–O vibrational stretch close to the experimentally observed value of 2115 cm –1 . Microkinetic modeling also shows that the fractional orders of CO and O 2 measured experimentally originate from multiple steps with a high degree of rate control and not from a simple competitive adsorption. The results demonstrate the complex reaction pathways that even CO oxidation on a simple single-atom system can follow, providing mechanistic insights for designing efficient Pt-based single-atom catalysts. Here, we further show that microkinetic modeling results are sensitive to changes in energies of intermediate and transition states within errors of density functional theory, which can ultimately lead to incorrect conclusions regarding the reaction pathways and most abundant reaction intermediates if not accounted for by experiments.

36 MATERIALS SCIENCE↗

The Fast Alternative Cryogenic Experiment Testbed

One of the challenges in the area of cryogenics for space exploration in the next millennium is providing the capability for inexpensive, frequent, access to space. Faced with this challenge during the International Space Station (ISS) build era, when other Space Shuttle manifesting opportunities are unavailable, a "proof of concept" cryostat has been developed to demonstrate the ability to accommodate low temperature science investigations within the constraints of the Hitchhiker siderail carrier. The Hitchhiker siderail carrier is available on a "mass available" basis during the ISS build era. In fact, several hitchhiker payloads flew with the deployment of the Unity module. Hitchhiker siderail carrier payloads have historically flown an average of about four times a year. A hybrid Solid Neon - Superfluid Helium cryostat has been developed with Janis Research Company to accommodate instruments of 16.5 cm diameter and 30 cm. length. This hybrid approach was taken in part to provide adequate on-orbit lifetime for instruments with high (conducted) heat loads from the instrumentation wiring. Mass, volume, lifetime and the launch hold scenario were all design drivers. In addition, with Ball Aerospace and Technologies Corporation, a multichannel VME architecture Germanium Resistance Thermometer (GRT) readout and heater control servo system has been developed. In a flight system, the cryostat and electronics payloads would be umbilically attached in a paired Hitchhiker siderail mount, and permit on-orbit command and telemetry capability. The results of performance tests of both the cryostat, and a helium sample instrument will be presented. The instrument features a self contained, miniaturized, nano-Kelvin resolution High Resolution Thermometer (HRT). This high level of thermal resolution is achieved through the utilization of a dc Superconducting Quantum Interference Device (SQUID). Although developed for the Low Temperature Microgravity Fundamental Physics investigator community, many design features are applicable in fields such as infrared and x-ray astronomy.

Nash, Alfred↗

High energy particle detection with large area superconducting microwire array

We present the first detailed study of an 8-channel2×2 mm$^{2}$ WSi superconducting microwire single photondetector (SMSPD) array exposed to 120 GeV proton beam and 8 GeVelectron and pion beam at the Fermilab Test Beam Facility. TheSMSPD detection efficiency was measured for the first time forprotons, electrons, and pions, enabled by the use of a silicontracking telescope that provided precise spatial resolution of30 μm for 120 GeV protons and 130 μm for 8 GeVelectrons and pions. The result demonstrated consistent detectionefficiency across pixels and at different bias currents. Timeresolution of 1.15 ns was measured for the first time for SMSPDwith proton, electron, and pions, enabled by the use of an MCP-PMTwhich provided a ps-level reference time stamp. The resultspresented is the first step towards developing SMSPD array systemsoptimized for high energy particle detection and identification forfuture accelerator-based experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Competing conduction mechanisms in high performance carbon nanotube fibers

The performance of carbon nanotube (CNT) cables, a contender for copper-wire replacement, is tied to its metallic and semi-conducting-like conductivity responses with temperature; the origin of the semi-conducting-like response however is an underappreciated incongruity in literature. With controlled aspect-ratio and doping-degree, over 61 unique cryogenic experiments including anisotropy and Hall measurements, CNT cable performance is explored at extreme temperatures (65 mK) and magnetic-fields (60 T). A semi-conducting-like conductivity response with temperature becomes temperature-independent approaching absolute-zero, uniquely demonstrating for the first time the necessity of heterogeneous fluctuation induced tunneling; complete de-doping leads to localized hopping, contrasting graphite's pure metallic-like response. High-field magneto-resistance (including novel +22 % longitudinal magneto-resistance near room-temperature) is analyzed with hopping and classical two-band models, both yielding a similar parameter useful for conductor development. Varying field-orientation angle uncovers significant two- and four-fold symmetries that are shown to be from Aharonov-Bohm-like corrections to the curvature-induced bandgap, a first for macroscale CNT fibers. Tight-binding calculations using Green's Function formalism model the largest, coherent transport to-date in commensurate CNT bundles in magnetic-field, revealing non-uniform transmission across bundle cross-sections with doping restoring uniformity; independent of doping, transport in bundle-junction-bundle systems are predominantly from CNTs adjacent to the other bundle—demonstrating that smaller bundles are more efficient for electronic transport. The final impact is predicting the ultimate conductivity of heterogeneous CNT cables using temperature and field-dependent transport, surpassing conductivity of traditional metals.

36 MATERIALS SCIENCE↗

Standoff Detection of Chemical Plumes Using Swept-ECQCL Remote Detection Technology: Results from EMRTC Complex Terrain Dual Tracer Experiment

As part of the Complex Terrain Dual Tracer Experiments performed in support of the LYNM program, a swept-wavelength external cavity quantum cascade laser (swept-ECQCL) remote detection system was deployed to measure chemical plume propagation with high temporal resolution. The swept-ECQCL remote detection technology was initially developed at PNNL, and is now under further development at Opticslah, LLC under SBIR funding from DOE (DOE SBIR Phase I Project DE-SC0019855, Remote Detection Technologies, Program Manager Chris Ramos). The swept-ECQCL technology provides a single-frequency infrared laser source which is rapidly scanned over a large wavelength range to measure the infrared absorption of gases, liquids, or solids. Analysis of the measured infrared absorption spectrum is used to detect, identify, and quantify the chemical species which are present. While most previous laser-based techniques used small wavelength tuning ranges to measure only a few isolated spectral lines of a few species, the swept-ECQCL provides the large tuning range needed to measure multiple species simultaneously, and to detect broad absorption features from large molecules or condensed phase materials. In addition, the swept-ECQCL systems have high enough spectral resolution and sensitivity to measure narrow lines of small molecules and determine isotope ratios. The remote detection system for gas plumes is based on the swept-ECQCL technology, and consists of a swept-ECQCL source, infrared detector, control electronics, and beam transmitting and alignment optics. The remote detection system directs the infrared output of the swept-ECQCL to a target retro reflector typically located at ~10-10,000 m distance. The swept-ECQCL wavelength is varied continuously over a large wavelength range (>1000 nm) at rates up to 1000 Hz. The swept ECQCL light reflected from the remote target is collected and focused onto an infrared photodetector. By measuring the detector signal continuously as the swept-ECQCL wavelength is varied, a time-series of absorption spectra are measured for the gases along the beam line of-sight. Based on analysis and fitting of the measured absorption spectra, the time-dependent chemical concentrations of species are determined. Multiple species and mixtures can be detected simultaneously, for all species with absorption features above the sensor noise floor. The sensor output is thus a continuous, high-speed record of identified chemicals along with their concentrations and isotope ratios of interest. The high-speed operation enables low-noise operation in conditions of atmospheric turbulence and allows tracking of fluctuating concentrations in transient chemical plumes as needed for reliable remote detection applications. All components operate with minimal cooling requirements and no cryogens are needed. In addition, the output infrared light is invisible with an intensity below the maximum permissible exposure (MPE) threshold of 100 mW/cm2 for these infrared wavelengths and thus eye safe. The measurement concept for plume detection using the swept-ECQCL remote detection system is as follows. The ECQCL beam is directed toward a remote retro-reflector, which reflects the beam back to the ECQCL system where it is focused onto an infrared photodetector. The line-of-sight from the ECQCL system to the retro-reflector defines the measurement path. The detected infrared signal is recorded continuously and detects the absorption of molecular species along the measurement path. Before a plume release, the system measures absorption from atmospheric constituents, which in this LWIR band consist primarily of lines from H 2 O and CO 2 , with additional weaker absorption from N 2 O, NH 3 , and O 3 possibly contributing. The system then measures any changes in absorption due to the tracer compounds when they enter the measurement path. The shape of absorption features is used to distinguish and identify the different tracer compounds, and the strength of the absorption is used to determine the path-integrated concentration – also called the column density.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ambient-Temperature Hydrogen Storage via Vanadium(II)-Dihydrogen Complexation in a Metal-Organic Framework

In this report, the widespread implementation of H 2 as a fuel is currently hindered by the high pressures or cryogenic temperatures required to achieve reasonable storage densities. In contrast, the realization of materials that strongly and reversibly adsorb hydrogen at ambient temperatures and moderate pressures could transform the transportation sector and expand adoption of fuel cells in other applications. To date, however, no adsorbent has been identified that exhibits a binding enthalpy within the optimal range of -15 to -25 kJ/mol for ambient-temperature hydrogen storage. Here, we report the hydrogen adsorption properties of the metal-organic framework (MOF) V 2 Cl 2.8 (btdd) (H 2 btdd, bis(1 H -1,2,3-triazolo[4,5- b ],[4',5'- i ])dibenzo[1,4]dioxin), which features exposed vanadium(II) sites capable of backbonding with weak π acids. Significantly, gas adsorption data reveal that this material binds H 2 with an enthalpy of -21 kJ/mol. This binding energy enables usable hydrogen capacities that exceed that of compressed storage under the same operating conditions. The Kubas-type vanadium(II)-dihydrogen complexation is characterized by a combination of techniques. From powder neutron diffraction data, a V-D 2 (centroid) distance of 1.966(8) Å is obtained, the shortest yet reported for a MOF. Using in situ infrared spectroscopy, the H-H stretch was identified, and it displays a red shift of 242 cm -1 . Electronic structure calculations show that a main contribution to bonding stems from the interaction between the vanadium d π and H 2 σ* orbital. Ultimately, the pursuit of MOFs containing high densities of weakly π-basic metal sites may enable storage capacities under ambient conditions that far surpass those accessible with compressed gas storage.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Off-state magnetoresistance in long-channel germanium Schottky-barrier MOSFETs

An increasing magnetic field perpendicular to an undoped semiconductor surface at low temperature is known to strengthen the binding of localized electrons to stationary ions, as the wavefunction's tails evolve from exponential to Gaussian. It is also known that application of a high bias voltage to a depleted semiconductor can liberate bound charge and induce a large drop in electrical resistance. We connect these established results to experimental electrical transport measurements on off-state germanium Schottky-barrier metal–oxide–semiconductor field-effect transistor (MOSFETs) with an aluminum oxide insulating dielectric and platinum germanide contacts. We make measurements at the three distinct orientations of the magnetic field with respect to the substrate and the current. At 6 K, we observe sharp attenuation of current by more than 2 orders of magnitude, within 60 mT, at a crossover magnetic field perpendicular to the substrate. A 1 T magnetic field attenuates the current by more than 4 orders of magnitude. The strength of the attenuation and the value of the crossover field are controlled by both the gate–source and drain–source voltages. The attenuation is much weaker when the magnetic field is parallel to the current. Finally, we orient the magnetic field parallel to the substrate, but perpendicular to the current, allowing us to distinguish charge hopping at the oxide interface from charge hopping in the bulk. In conclusion, this large off-state magnetoresistance can be exploited for cryogenic magnetic- and photo-detection, and for high-bias, low-leakage MOSFETs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

NASA Tech Briefs, July 2011

Topics covered include: 1) Collaborative Clustering for Sensor Networks; 2) Teleoperated Marsupial Mobile Sensor Platform Pair for Telepresence Insertion Into Challenging Structures; 3) Automated Verification of Spatial Resolution in Remotely Sensed Imagery; 4) Electrical Connector Mechanical Seating Sensor; 5) In Situ Aerosol Detector; 6) Multi-Parameter Aerosol Scattering Sensor; 7) MOSFET Switching Circuit Protects Shape Memory Alloy Actuators; 8) Optimized FPGA Implementation of Multi-Rate FIR Filters Through Thread Decomposition; 9) Circuit for Communication Over Power Lines; 10) High-Efficiency Ka-Band Waveguide Two-Way Asymmetric Power Combiner; 11) 10-100 Gbps Offload NIC for WAN, NLR, and Grid Computing; 12) Pulsed Laser System to Simulate Effects of Cosmic Rays in Semiconductor Devices; 13) Flight Planning in the Cloud; 14) MPS Editor; 15) Object-Oriented Multi Disciplinary Design, Analysis, and Optimization Tool; 16) Cryogenic-Compatible Winchester Connector Mount and Retaining System for Composite Tubes; 17) Development of Position-Sensitive Magnetic Calorimeters for X-Ray Astronomy; 18) Planar Rotary Piezoelectric Motor Using Ultrasonic Horns; 19) Self-Rupturing Hermetic Valve; 20) Explosive Bolt Dual-Initiated from One Side; 21) Dampers for Stationary Labyrinth Seals; 22) Two-Arm Flexible Thermal Strap; 23) Carbon Dioxide Removal via Passive Thermal Approaches; 24) Polymer Electrolyte-Based Ambient Temperature Oxygen Microsensors for Environmental Monitoring; 25) Pressure Shell Approach to Integrated Environmental Protection; 26) Image Quality Indicator for Infrared Inspections; 27) Micro-Slit Collimators for X-Ray/Gamma-Ray Imaging; 28) Scatterometer-Calibrated Stability Verification Method; 29) Test Port for Fiber-Optic-Coupled Laser Altimeter; 30) Phase Retrieval System for Assessing Diamond Turning and Optical Surface Defects; 31) Laser Oscillator Incorporating a Wedged Polarization Rotator and a Porro Prism as Cavity Mirror; 32) Generic, Extensible, Configurable Push-Pull Framework for Large-Scale Science Missions; 33) Dynamic Loads Generation for Multi-Point Vibration Excitation Problems; 34) Optimal Control via Self-Generated Stochasticity; 35) Space-Time Localization of Plasma Turbulence Using Multiple Spacecraft Radio Links; 36) Surface Contact Model for Comets and Asteroids; 37) Dust Mitigation Vehicle; 38) Optical Coating Performance for Heat Reflectors of the JWST-ISIM Electronic Component; 39) SpaceCube Demonstration Platform; 40) Aperture Mask for Unambiguous Parity Determination in Long Wavelength Imagers; 41) Spaceflight Ka-Band High-Rate Radiation-Hard Modulator; 42) Enabling Disabled Persons to Gain Access to Digital Media; 43) Cytometer on a Chip; 44) Principles, Techniques, and Applications of Tissue Microfluidics; and 45) Two-Stage Winch for Kites and Tethered Balloons or Blimps.

Source record↗

Theoretical Studies of the Extra-terrestrial Chemistry of Biogenic Elements and Compounds

Results are presented on the following:(A) Ab initio quantum chemical studies of reactions in astrophysical ices.Theoretical electronic structure calculations were used to investigate reactions between formaldehyde (H2CO) and both hydrogen cyanide (HCN) and isocyanide (HNC) in search of other favorable reactions such as ammonia-formaldehyde addition, which was found in a recent theoretical study to be strongly enhanced when it occurs within cold ices.The present study examines further reactions between this product and H2CO in ices.(B) Heterogeneous hydrogenation of CO and H2CO on icy grain mantles.Formaldehyde (H2CO) and methanol (CH30H) are thought to be produced in the interstellar medium by the successive hydrogenation of carbon monoxide (CO) on grain surfaces. In the gas phase, the steps in which H adds to CO and H2CO possess modest barriers and are too inefficient to account for the observed abundances. Recent laboratory work has confirmed that formaldehyde and methanol are formed when H atoms are deposited on CO ice at 12 K. The present study employed ab initio quantum chemical calculations to investigate the impact of water ice on the sequential hydrogenation of CO.(C) Ice-bound condensed-phase reactions involving formic acid (HCOOH), methylenimine (CH2NH), hydrogen cyanide (HCN), hydrogen isocyanide (HNC), and ammonia ( 3) were investigated in order to characterize possible pathways to larger organic species that are efficient at the cold temperatures prevalent in cometary nuclei and the interstellar medium. (D) Pathways to glycine and other amino acids in ultraviolet-irradiated ices determined via quantum chemical modeling.(E) Photoionization in ultraviolet processing of astrophysical ice analogs at cryogenic temperatures.

Woon, David E.↗

Fluid dynamic simulation and analysis of water-cooling systems for the Electron-Ion Collider

The Electron-Ion Collider is the newest large-scale project at Brookhaven National Laboratory. The collider’s purpose is to provide further advancements in the knowledge of the universe’s origin by accelerating particles near the speed of light. Our project for this 3.8 km ring was to create a thermal hydraulic steady-state simulation design of the water-cooling system to be cost-effective and energy efficient, as envisioned by Charlie Foltz, the EIC Infrastructure Division Director. The system would include a supply and return header, which cools several thousand components of the ring. The water would then be returned and cooled down using a system of cooling towers and plate and frame heat exchangers. Due to the size of the system and the complexity of the network analysis, a fluid dynamic simulation software, AFT Fathom, was used. Since previous methods of maintaining systems relied on building upon smaller real-life models and implementing empirical data, this flow model was unique and first of a kind in the domain of accelerator design, construction and operation. Therefore, our hydraulic team piloted a new method to perform network analysis on a large scale cooling system. We successfully created several test scenarios for system behavior in a shorter time compared to the method of performing hand calculations. Cooling specifications for heat rejection, pressure drop, flow rate, and pipe sizing were changed based on the individual systems of the vacuum, radio frequency (RF), magnet and power supply, and cryogenics sections. Finally, we used DOE guidelines to perform life-cycle cost analysis with net present value and carbon saving analysis on the systems where pipe size could be optimized.

43 PARTICLE ACCELERATORS↗

Lifetime study of the ColdADC for the Deep Underground Neutrino Experiment

ColdADC is a custom ASIC digitizer implemented in 65 nm CMOS technology using specialized techniques for long-term reliability in cryogenic environments. ColdADC was developed for use in the DUNE Far Detector complex, which will consist of four liquid argon time projection chambers. Each contains 17 kilotons liquid argon as the target material in order to measure neutrino oscillations. Approximately 40,000 ColdADC ASICs will be installed for DUNE in the first two large detectors and will be operated at cryogenic temperatures during the experiment without replacement. The lifetime of the ColdADC is a critical parameter affecting the data quality and physics sensitivity of the experiment. A measurement of the lifetime of the ColdADC was carried out, and the results shown in this paper assure orders of magnitude longer lifetime of the ColdADC than the planned operation time of the detectors.

Front-end electronics for detector readout↗

Scanning SQUID microscopy in a cryogen-free dilution refrigerator

We report a scanning superconducting quantum interference device (SQUID) microscope in a cryogen-free dilution refrigerator with a base temperature at the sample stage of at least 30 mK. The microscope is rigidly mounted to the mixing chamber plate to optimize thermal anchoring of the sample. The microscope housing fits into the bore of a superconducting vector magnet, and our design accommodates a large number of wires connecting the sample and sensor. Through a combination of vibration isolation in the cryostat and a rigid microscope housing, we achieve relative vibrations between the SQUID and the sample that allow us to image with micrometer resolution over a 150 μm range while the sample stage temperature remains at base temperature. To demonstrate the capabilities of our system, we show images acquired simultaneously of the static magnetic field, magnetic susceptibility, and magnetic fields produced by a current above a superconducting micrometer-scale device.

47 OTHER INSTRUMENTATION↗

Optimization of gold germanium (Au 0.17 Ge 0.83 ) thin films for high sensitivity resistance thermometry

Gold–germanium (Au x Ge 1–x ) solid solutions have been demonstrated as highly sensitive thin film thermometers for cryogenic applications. However, little is known regarding the performance of the films for thicknesses less than 100 nm. In response, here we report on the resistivity and temperature coefficient of resistance (TCR) for sputtered films with thicknesses ranging from 10 to 100 nm and annealed at temperatures from 22 to 200°C. The analysis is focused upon composition x=0.17, which demonstrates a strong temperature sensitivity over a broad range. The thinnest films are found to provide an enhancement in TCR, which approaches 20% K –1 at 10 K. Furthermore, reduced anneal temperatures are required to crystallize the Ge matrix and achieve a maximum TCR for films of reduced thickness. These features favor the application of ultra-thin films as high-sensitivity, on-device thermometers in micro- and nanolectromechanical systems.

59 BASIC BIOLOGICAL SCIENCES↗

Development of far infrared detection techniques

This grant supports the development of a variety of advanced far infrared detection techniques that will be used in future NASA missions such as the Space Infrared Telescope Facility (SIRTF). These studies span the wavelength region of 30-200 microns and include development of focal planes and electronics that would utilize them. Efforts reported here represent collaborations among the University of Arizona's Steward Observatory; Lawrence Berkeley Laboratories (LBL); and the University of California at Berkeley. The overall goal of this program is to demonstrate extremely high performance detectors for low background applications between 30-200 microns. For the 40-120 micron region, the program is developing a 32x32 filled detector array. Previous work has demonstrated the required performance with a Z-Plane array architecture; we are now upgrading construction facilities and techniques to increase yields and reliability. We have completed the initial tradeoff analysis for the interconnects between the detectors and and readouts. We found satisfactory performance for both Flex-Cable and Tape Automated Bonding (TAB) devices, but analysis showed that an all-sapphire device would not meet our requirements. In addition, the effort continued to develop readouts that can operate close to the detector element temperature; success would substantially improve the manufacturability of the arrays. For the 100-200 micron range, previous work has demonstrated good performance with individual detector elements of stressed Ge:Ga; current efforts are to increase the quantum efficiency of these devices. Work continues to discover how to construct an alternate type of long wave detector, Ge:B Blocked Impurity Band devices. Following descoping of SIRTF, we are closing out the bolometer and refrigerator development. We documented the optical designs and approaches developed previously to meet the specific requirements of these detector types in terms of modulation of the signals for good photometric behavior within the constraints of a compact and self-contained cryogenic instrument. Further study was initiated for the Band 3 optical train, where we have concerns about complexity and the manufacturability of one component.

Rieke, George↗

Novel Multiplexing Technique for Detector and Mixer Arrays

Future submillimeter and far-infrared space telescopes will require large-format (many 1000's of elements) imaging detector arrays to perform state-of-the-art astronomical observations. A crucial issue related to a focal plane array is a readout scheme which is compatible with large numbers of cryogenically-cooled (typically < 1 K) detectors elements. When the number of elements becomes of the order of thousands, the physical layout for individual readout amplifiers becomes nearly impossible to realize for practical systems. Another important concern is the large number of wires leading to a 0.1-0.3 K platform. In the case of superconducting transition edge sensors (TES), a scheme for time-division multiplexing of SQUID read-out amplifiers has been recently demonstrated. In this scheme the number of SQUIDs is equal to the number (N) of the detectors, but only one SQUID is turned on at a time. The SQUIDs are connected in series in each column of the array, so the number of wires leading to the amplifiers can be reduced, but it is still of the order of N. Another approach uses a frequency domain multiplexing scheme of the bolometer array. The bolometers are biased with ac currents whose frequencies are individual for each element and are much higher than the bolometer bandwidth. The output signals are connected in series in a summing loop which is coupled to a single SQUID amplifier. The total number of channels depends on the ratio between the SQUID bandwidth and the bolometer bandwidth and can be at least 100 according to the authors. An important concern about this technique is a contribution of the out-of-band Johnson noise which multiplies by factor N(exp 1/2) for each frequency channel. We propose a novel solution for large format arrays based on the Hadamard transform coding technique which requires only one amplifier to read out the entire array of potentially many 1000's of elements and uses approximately 10 wires between the cold stage and room temperature electronics. This can significantly reduce the complexity of the readout circuits.

Karasik, Boris S.↗

Deciphering decomposition pathways of high explosives with cryogenic X-ray Raman spectroscopy

We employed cryogenic X-ray Raman spectroscopy to investigate the early-stage decomposition of the high explosive molecule hexanitrohexaazaisowurtzitane (CL-20). By systematically varying the radiation dose under cryogenic conditions, we induced the decomposition of the molecule using ionizing radiation and observed the evolution of spectral features at the carbon, nitrogen, and oxygen K edges. Through extensive first-principles calculations, we identified key intermediates in the early stages of the decomposition process, resulting from C–C and C–N bond cleavage which leads to the opening of the internal cage structure. A detailed analysis of spectral trends and fingerprints provided evidence supporting N–NO 2 homolytic cleavage as the primary initial decomposition pathway. The combination of advanced core-level spectroscopy methods and state-of-the-art theoretical calculations enabled a comprehensive characterization of the molecular changes induced by controlled radiation dose exposures. In conclusion, our findings establish a benchmark for understanding the decomposition chemistry of high-explosive materials, offering important insights into their stability and reactivity under extreme conditions.

X-ray Raman spectroscopy↗