Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Acceleration of Cooling of Ice Giants by Condensation in Early Atmospheres

The present infrared brightness of a planet originates partly from the accretion energy that the planet gained during its formation and hence provides important constraints to the planet formation process. A planet cools down from a hot initial state to the present state by losing energy through radiative emission from its atmosphere. Thus, the atmospheric properties affect the planetary cooling rate. Previous theories of giant planet cooling assume that the atmospheric composition is unchanged throughout the evolution. Planet formation theories, however, suggest that the atmospheres especially of ice giants are rich in heavy elements in the early stages. These heavy elements include condensable species such as H{sub 2}O, NH{sub 3}, and CH{sub 4}, which are expected to have a great impact on atmospheric temperature and thus on radiative emission through latent heat release. In this study we investigate the effect of such condensation on the planetary emission flux and quantify the impact on the cooling timescale. We then demonstrate that the latent heat of these species keeps the atmosphere hot and thus the emission flux high for billions of years, resulting in an acceleration of the cooling of ice giants. This sheds light on the long-standing problem that Uranus is much less bright than theoretically predicted and is different in brightness from Neptune in spite of the similarity in mass and radius. We also find that young ice giants with highly enriched atmospheres are much brighter in the mid-infrared than ice giants with non-enriched atmospheres. This provides important implications for future direct imaging of extrasolar ice giants.

79 ASTRONOMY AND ASTROPHYSICS↗

The Role of Cerenkov Radiation in the Pressure Balance of Cool Core Clusters of Galaxies

Despite the substantial progress made recently in understanding the role of AGN feedback and associated non-thermal effects, the precise mechanism that prevents the core of some clusters of galaxies from collapsing catastrophically by radiative cooling remains unidentified. In this Letter, we demonstrate that the evolution of a cluster's cooling core, in terms of its density, temperature, and magnetic field strength, inevitably enables the plasma electrons there to quickly become Cerenkov loss dominated, with emission at the radio frequency of ≲350 Hz, and with a rate considerably exceeding free–free continuum and line emission. However, the same does not apply to the plasmas at the cluster's outskirts, which lacks such radiation. Owing to its low frequency, the radiation cannot escape, but because over the relevant scale size of a Cerenkov wavelength the energy of an electron in the gas cannot follow the Boltzmann distribution to the requisite precision to ensure reabsorption always occurs faster than stimulated emission, the emitting gas cools before it reheats. This leaves behind the radiation itself, trapped by the overlying reflective plasma, yet providing enough pressure to maintain quasi-hydrostatic equilibrium. The mass condensation then happens by Rayleigh–Taylor instability, at a rate determined by the outermost radius where Cerenkov radiation can occur. In this way, it is possible to estimate the rate at ≈2 M {sub ⊙} year{sup −1}, consistent with observational inference. Thus, the process appears to provide a natural solution to the longstanding problem of “cooling flow” in clusters; at least it offers another line of defense against cooling and collapse should gas heating by AGN feedback be inadequate in some clusters.

79 ASTRONOMY AND ASTROPHYSICS↗

Cooling Characteristics of a Pratt and Whitney R-2800 Engine Installed in an NACA Short-nose High-inlet-velocity Cowling

An investigation was made of the cooling characteristics of a P and W R-2800 engine with NACA short-nose high inlet-velocity cowling. The internal aerodynamics of the cowling were studied for ranges of propeller-advance ratio and inlet-velocity ratio obtained by deflection of cowling flaps. Tests included variations of engine power, fuel/air ratio and cooling-air pressure drop. Engine cooling data are presented in the form of cooling correlation curves, and an example for calculation of cooling requirements in flight is included.

HIGH-INLET-VELOCITY (SHORT-NOSE)↗

Development of a Space-Flight ADR Providing Continuous Cooling at 50 mK with Heat Rejection at 10 K

Future astronomical instruments will require sub-Kelvin detector temperatures to obtain high sensitivity. In many cases large arrays of detectors will be used, and the associated cooling systems will need performance surpassing the limits of present technologies. NASA is developing a compact cooling system that will lift heat continuously at temperatures below 50 mK and reject it at over 10 K. Based on Adiabatic Demagnetization Refrigerators (ADRs), it will have high thermodynamic efficiency and vibration-free operation with no moving parts. It will provide more than 10 times the current flight ADR cooling power at 50 mK and will also continuously cool a 4 K stage for instruments and optics. In addition, it will include an advanced magnetic shield resulting in external field variations below 5 T. We describe the cooling system here and report on the progress in its development.

space-flight↗

Development of a Space-Flight ADR Providing Continuous Cooling at 50 Mk with Heat Rejection at 10 K

Future astronomical instruments will require sub-Kelvin detector temperatures to obtain high sensitivity. In many cases large arrays of detectors will be used, and the associated cooling systems will need performance surpassing the limits of present technologies. NASA is developing a compact cooling system that will lift heat continuously at temperatures below 50 mK and reject it at over 10 K. Based on Adiabatic Demagnetization Refrigerators (ADRs), it will have high thermodynamic efficiency and vibration-free operation with no moving parts. It will provide more than 10 times the current flight ADR cooling power at 50 mK and will also continuously cool a 4 K stage for instruments and optics. In addition, it will include an advanced magnetic shield resulting in external field variations below 5 T. We describe the cooling system here and report on the progress in its development.

sub-Kelvin ADR↗

Sub-Kelvin Cooling Systems for Quantum Computers

Future large-scale quantum processors (i.e. 100s of qubits), especially those based on superconducting circuits, will require large cooling powers (~10s of microW) at very low temperatures (<50 mK) with stringent temperature stabilities to avoid quantum decoherence and thus guarantee successful operation of such systems. One attractive option for providing this cooling is through Continuous Adiabatic Demagnetization Refrigerators (CADR). Scalable state-of-the-art CADRs at NASA's Goddard Space Flight Center have successfully shown to lift 6 W of heat at 50 mK with a 1 K temperature stability while rejecting its heat to a cryocooler at 4K. Carefully planned and proper heat sinking of cables, attenuators, and microwave components at various temperature stages (between 4K and base temperature) is critical in the cooling architecture of quantum computers and can be provided through proper staging of each unit within the CADR system. As an alternative method of cooling, dilution refrigerators with the potential to meet cooling requirements of emerging large-scale quantum processors are also discussed.

quantum cooling↗

Film Cooling Effectiveness Measurements on a CMC-Simulated Flat Plate

Ceramic matrix composites (CMC) are high temperature materials that can allow higher operating turbomachinery engine temperatures with less coolant required. One method of fabricating ceramic matrix composites is by weaving fibers into the shape of an airfoil. Generally, CMC fiber tows are assembled with various weave patterns, but this uneven surface could introduce aerodynamic losses, and it will be necessary to determine the best film cooling hole arrangement for minimal thermal engine efficiency loss. As part of an effort to assess the impact of geometric constraints of CMC implementation relative to metallic high pressure turbine blades, an experimental study was performed to investigate the effect of film cooling on a CMC-like surface roughened flat plate. Film cooling effectiveness measurements were acquired on a large-scale surface with a ceramic matrix composite weave pattern and on a smooth surface for comparison. A single row and a 2-row cooling hole arrangement were investigated with different hole sizes. Infrared thermography data was acquired at several Reynolds numbers and blowing ratios. Results showed that the effect on span averaged film cooling effectiveness was small between a weave surface pattern and a smooth surface, while hole spacing dependence had a much stronger effect.

infrared↗

Effects of e-beam parameters on coherent electron cooling

Coherent Electron Cooling (CeC) requires detailed control of the phase between the hadron an the FEL-amplified wave packet. This phase depends on local electron beam parameters such as the energy spread and the peak current. In this paper, we examine the effects of local density variations on the cooling rates for CeC. Coherent Electron Cooling (CeC) [1] is a new concept in intense, high energy hadron beamcooling, in which the Debye screened charge perturbation calculated in [2] is used to seed a high-gain free electron laser (FEL). Using delays to give the perturbing hadron an energy-dependent longitudinal displacement relative to its frequencymodulated charge perturbation, the hadron receives an energy-dependent kick which reduces its energy variation from the design energy. The equations of motion in [1] assume that the electron bunch is the same physical size as the hadron bunch, and has a homogeneous charge density across the entire bunch. In practice, the electron bunches will be much shorter than the hadron bunch, and this local spacial inhomogeneity in the charge distribution will alter the gain length of the FEL, resulting in both a change in the amplification of the initial signal and a phase shift. In this paper we consider these inhomogeneity effects, determining cooling equations for bunched beam CeC consistent with these effects and determining thresholds for the cooling parameters.

43 PARTICLE ACCELERATORS↗

ITER's Tokamak Cooling Water System and the the Use of ASME Codes to Comply with French Regulations of Nuclear Pressure Equipment

During inductive plasma operation of ITER, fusion power will reach 500 MW with an energy multiplication factor of 10. The heat will be transferred by the Tokamak Cooling Water System (TCWS) to the environment using the secondary cooling system. Plasma operations are inherently safe even under the most severe postulated accident condition a large, in-vessel break that results in a loss-of-coolant accident. A functioning cooling water system is not required to ensure safe shutdown. Even though ITER is inherently safe, TCWS equipment (e.g., heat exchangers, piping, pressurizers) are classified as safety important components. This is because the water is predicted to contain low-levels of radionuclides (e.g., activated corrosion products, tritium) with activity levels high enough to require the design of components to be in accordance with French regulations for nuclear pressure equipment, i.e., the French Order dated 12 December 2005 (ESPN). ESPN has extended the practical application of the methodology established by the Pressure Equipment Directive (97/23/EC) to nuclear pressure equipment, under French Decree 99-1046 dated 13 December 1999, and Order dated 21 December 1999 (ESP). ASME codes and supplementary analyses (e.g., Failure Modes and Effects Analysis) will be used to demonstrate that the TCWS equipment meets these essential safety requirements. TCWS is being designed to provide not only cooling, with a capacity of approximately 1 GW energy removal, but also elevated temperature baking of first-wall/blanket, vacuum vessel, and divertor. Additional TCWS functions include chemical control of water, draining and drying for maintenance, and facilitation of leak detection/localization. The TCWS interfaces with the majority of ITER systems, including the secondary cooling system. U.S. ITER is responsible for design, engineering, and procurement of the TCWS with industry support from an Engineering Services Organization (ESO) (AREVA Federal Services, with support from Northrop Grumman, and OneCIS). ITER International Organization (ITER-IO) is responsible for design oversight and equipment installation in Cadarache, France. TCWS equipment will be fabricated using ASME design codes with quality assurance and oversight by an Agreed Notified Body (approved by the French regulator) that will ensure regulatory compliance. This paper describes the TCWS design and how U.S. ITER and fabricators will use ASME codes to comply with EU Directives and French Orders and Decrees.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Critical Design Issues of Tokamak Cooling Water System of ITER's Fusion Reactor

U.S. ITER is responsible for the design, engineering, and procurement of the Tokamak Cooling Water System (TCWS). The TCWS transfers heat generated in the Tokamak to cooling water during nominal pulsed operation 850 MW at up to 150 C and 4.2 MPa water pressure. This water contains radionuclides because impurities (e.g., tritium) diffuse from in-vessel components and the vacuum vessel by water baking at 200 240 C at up to 4.4MPa, and corrosion products become activated by neutron bombardment. The system is designated as safety important class (SIC) and will be fabricated to comply with the French Order concerning nuclear pressure equipment (December 2005) and the EU Pressure Equipment Directive using ASME Section VIII, Div 2 design codes. The complexity of the TCWS design and fabrication presents unique challenges. Conceptual design of this one-of-a-kind cooling system has been completed with several issues that need to be resolved to move to next stage of the design. Those issues include flow balancing between over hundreds of branch pipelines in parallel to supply cooling water to blankets, determination of optimum flow velocity while minimizing the potential for cavitation damage, design for freezing protection for cooling water flowing through cryostat (freezing) environment, requirements for high-energy piping design, and electromagnetic impact to piping and components. Although the TCWS consists of standard commercial components such as piping with valves and fittings, heat exchangers, and pumps, complex requirements present interesting design challenges. This paper presents a brief description of TCWS conceptual design and critical design issues that need to be resolved.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Technical Evaluation of Side Stream Filtration for Cooling Towers

Cooling towers are an integral component of many refrigeration systems, providing comfort or process cooling across a broad range of applications. Cooling towers represent the point in a cooling system where heat is dissipated to the atmosphere through evaporation. Cooling towers are commonly used in industrial applications and in large commercial buildings to release waste heat extracted from a process or building system through evaporation of water.

Technical, Evaluation, Side-Stream, Filtration, Co↗

Energy Performance Assessment of Radiant Cooling System through Modeling and Calibration at Component Level

The paper describes a case study of an information technology office building with a radiant cooling system and a conventional variable air volume (VAV) system installed side by side so that performancecan be compared. First, a 3D model of the building involving architecture, occupancy, and HVAC operation was developed in EnergyPlus, a simulation tool. Second, a different calibration methodology was applied to develop the base case for assessing the energy saving potential. This paper details the calibration of the whole building energy model to the component level, including lighting, equipment, and HVAC components such as chillers, pumps, cooling towers, fans, etc. Also a new methodology for the systematic selection of influence parameter has been developed for the calibration of a simulated model which requires large time for the execution. The error at the whole building level [measured in mean bias error (MBE)] is 0.2%, and the coefficient of variation of root mean square error (CvRMSE) is 3.2%. The total errors in HVAC at the hourly are MBE = 8.7% and CvRMSE = 23.9%, which meet the criteria of ASHRAE 14 (2002) for hourly calibration. Different suggestions have been pointed out to generalize the energy saving of radiant cooling system through the existing building system. So a base case model was developed by using the calibrated model for quantifying the energy saving potential of the radiant cooling system. It was found that a base case radiant cooling system integrated with DOAS can save 28% energy compared with the conventional VAV system.

Building Energy Simulation↗

New Directions in Thermoelectric and Thermal-Electric Cooling

Conventional thermoelectric coolers have been widely used for cooling of electronic devices. Utilizing bismuth telluride materials, these Peltier modules are typically categorized as high heat flux devices that can achieve modest temperature differences in a compact architecture. Breaking from convention of typical bismuth telluride thermoelectric devices, an alternative method of providing thermal-electric cooling will be discussed providing inspiration for new cooling directions and materials challenges. While this approach has application in electric cooling of solids, there are also wider applications including space cooling and heat pumping.

42 ENGINEERING↗

Effects of cooling time on a closed LWR fuel cycle

In this study, the effects of cooling time prior to reprocessing spent LWR fuel has on the reactor physics characteristics of a PWR fully loaded with homogeneously mixed U-Pu or U-TRU oxide (MOX) fuel is examined. A reactor physics analysis was completed using the CASM04e code. A void reactivity feedback coefficient analysis was also completed for an infinite lattice of fresh fuel assemblies. Some useful conclusions can be made regarding the effect that cooling time prior to reprocessing spent LWR fuel has on a closed homogeneous MOX fuel cycle. The computational analysis shows that it is more neutronically efficient to reprocess cooled spent fuel into homogeneous MOX fuel rods earlier rather than later as the fissile fuel content decreases with time. Also, the number of spent fuel rods needed to fabricate one MOX fuel rod increases as cooling time increases. In the case of TRU MOX fuel, with time, there is an economic tradeoff between fuel handling difficulty and higher throughput of fuel to be reprocessed. The void coefficient analysis shows that the void coefficient becomes progressively more restrictive on fuel Pu content with increasing spent fuel cooling time before reprocessing. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

TRACE Code Validation of BWR SVEA Fuel Assembly Spray Cooling

Emergency spray cooling injection is a safety feature implemented in many boiling water reactor designs to reflood a reactor during an accident. Significant experimental work has qualified the efficacy of spray cooling, and ongoing computational modeling efforts strive to more accurately portray the phenomena involved. This work examines the physical phenomena pertaining to emergency spray cooling injection over SVEA-type fuel assemblies. BWR emergency core cooling system (ECCS) designs commonly incorporate a Low-Pressure Core Spray (LPCS) system that introduces coolant through spray nozzles directed to the top of the core, and are located in the upper plenum region. This design is effective for LOCA response, particularly during the initial refill and reflood stages of accident response where the goal is limiting the peak cladding temperature rise in the core. The U.S. NRC thermal-hydraulics code TRACE version 5.0 Patch 4 has been chosen to simulate the separate-effect tests performed by ASEA-ATOM. The computational model was evaluated by performing forward uncertainty quantification using Dakota as the analysis tool and code driver on 31 identified parameters from the input model and TRACE physical constitutive models. This paper discusses the sensitivity of the investigated parameters with respect to spray cooling simulation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Performance tests of helium circulator under abnormal cooling conditions - 18523

Helium circulator is one of the key equipment of High-temperature Gas-cooled Reactor Pebble-bed Module (HTR-PM) and the unique rotating equipment of primary loop. It transports heat generated by fission reactions from reactor core to steam generator by forcing helium circulating in primary loop. As the study on the characteristics of helium circulator in HTGR was limited and the advanced designs integrated with many new technologies, a prototype of helium circulator was manufactured. It was supported by Active Magnetic Bearings (AMBs), and was assembled in a pressure vessel. The prototype was tested in Engineering Test Facility - Helium Circulator (ETF-HC), which is a full scale, rated flow rate and power, engineering test loop. Although performance tests under normal operation condition were successfully fulfilled, the complete features and performance still need further verification, especially for abnormal cooling conditions. Thus performance tests under abnormal cooling operation conditions were carried out. Tests such as temporary coolant loss of motor and AMBs cooler and abnormal high-temperature cooling water condition were fulfilled. All performance tests results showed that helium circulator met the entire requirement of HTR-PM plant under abnormal cooling conditions and validated its safety and reliability. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Numerical study of film cooling with internal coolant cross-flow effects - 18569

In the present study, the influence of coolant supply condition was investigated, the coolant supply at the hole entrance were considered to be either a plenum condition or a coolant cross-flow condition. The results indicated that at low blowing ratio M=0.5, the coolant supply channel structure has little effect on film cooling performance, however, at high blowing ratio M=1.0, the adiabatic wall film cooling effectiveness was significantly different between the plenum case and the cross-flow cases. In general, for the plenum condition, film cooling is better at M=0.5 than M=1.0, while for the cross-flow condition, the film cooling effectiveness is better at blowing ratio M=0.5 in the near hole region, while at further downstream region, the film cooling effectiveness is better at M=1.0. (authors)

42 ENGINEERING↗

Design and Flow Considerations of Additively Manufactured, Internal Cooling Geometries for Small Industrial Gas Turbines

Additive manufacturing is now a mainstream technology and can be utilized to rapidly develop and test turbine airfoil cooling networks. This paper reports on an ongoing effort to integrate advanced internal cooling architectures in a realistic blade profile for test in a high-speed cascade. Airfoil cooling schemes were developed using reduced order modeling and computer aided design. However, the additive manufacturing impacts on cooling channel flow performance were unknown. Test articles consisting of typical cooling features and networks were derived from the designs and flow proved to identify additive manufacturing impacts on performance and develop guidelines to mitigate these impacts.

additive manufacturing↗