Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Classical Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Design and engineering of dispersion and loss in photonic crystal fiber 1 × 4 power splitter (PCFPS) based on hole size alteration and optofluidic infiltration

We have presented a technique based on optofluidic infiltration and air-holes diameter variation together to design a 1 × 4 photonic crystal fiber power splitter (PCFPS) which have very low dispersion (D): (0 ≤ D ≤ 2.5 (ps/nm/km) and very low loss (L): 0 ≤ L ≤ 0.025(dB/cm) in a wide range of wavelengths (1100–1700 nm). This approach allows us to control the dispersion of the fundamental mode in a PCF beam splitter by choosing appropriate refractive indices for liquids and suitable diameters for air-holes in PCF power splitter. In fact, the techniques, used in this paper are complementary of each other and give us more excellent results which are better than other reported results in researchers’ works so far. In this work, a new design of 1 × 4 photonic crystal fiber power splitter is proposed by using beam propagation method. An optical Gaussian signal at a wavelength of third communication window range (1550 nm) is inserted into the central core and equally is divided into four core (25% of the total input power interred to each core). In addition, the physical behavior of coupling characteristics is obtained by using coupled mode analysis. Numerical simulations show that input optical signal can be equally divided in photonic crystal fiber structure with low dispersion and low loss. The total size of proposed PCFPS is 30 µm × 30 µm × 1.2 mm, too.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Accuracy improvement in a calibration test bench for accelerometers by a vision system

A procedure is described in this paper for the accuracy improvement of calibration of low-cost accelerometers in a prototype rotary test bench, driven by a brushless servo-motor and operating in a low frequency range of vibrations (0 to 5 Hz). Vibration measurements by a vision system based on a low frequency camera have been carried out, in order to reduce the uncertainty of the real acceleration evaluation at the installation point of the sensor to be calibrated. A preliminary test device has been realized and operated in order to evaluate the metrological performances of the vision system, showing a satisfactory behavior if the uncertainty measurement is taken into account. A combination of suitable settings of the control parameters of the motion control system and of the information gained by the vision system allowed to fit the information about the reference acceleration at the installation point to the needs of the procedure for static and dynamic calibration of three-axis accelerometers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Precision requirements for spin-echo-based quantum memories

Spin-echo techniques are essential for achieving long coherence times in solid-state quantum memories for light because of inhomogeneous broadening of the spin transitions. It has been suggested that unrealistic levels of precision for the radio-frequency control pulses would be necessary for successful decoherence control at the quantum level. Here we study the effects of pulse imperfections in detail, using both a semiclassical and a fully quantum-mechanical approach. Our results show that high efficiencies and low noise-to-signal ratios can be achieved for the quantum memories in the single-photon regime for realistic levels of control pulse precision. We also analyze errors due to imperfect initial-state preparation (optical pumping), showing that they are likely to be more important than control pulse errors in many practical circumstances. These results are crucial for future developments of solid-state quantum memories.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Acoustic beam control in biomimetic projector via velocity gradient

A biomimetic projector (BioP) based on computerized tomography of pygmy sperm whale's biosonar system has been designed using gradient-index (GRIN) material. The directivity of this BioP device was investigated as function of frequency and the velocity gradient of the GRIN material. A strong beam control over a broad bandwidth at the subwavelength scale has been achieved. Compared with a bare subwavelength source, the main lobe pressure of the BioP is about five times as high and the angular resolution is one order of magnitude better. Our results indicate that this BioP has excellent application potential in miniaturized underwater sonars.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimal pulse spacing for dynamical decoupling in the presence of a purely dephasing spin bath

Maintaining quantum coherence is a crucial requirement for quantum computation; hence protecting quantum systems against their irreversible corruption due to environmental noise is an important open problem. Dynamical decoupling (DD) is an effective method for reducing decoherence with a low control overhead. It also plays an important role in quantum metrology, where, for instance, it is employed in multiparameter estimation. While a sequence of equidistant control pulses [the Carr-Purcell-Meiboom-Gill (CPMG) sequence] has been ubiquitously used for decoupling, Uhrig recently proposed that a nonequidistant pulse sequence [the Uhrig dynamic decoupling (UDD) sequence] may enhance DD performance, especially for systems where the spectral density of the environment has a sharp frequency cutoff. On the other hand, equidistant sequences outperform UDD for soft cutoffs. The relative advantage provided by UDD for intermediate regimes is not clear. In this paper, we analyze the relative DD performance in this regime experimentally, using solid-state nuclear magnetic resonance. Our system qubits are {sup 13}C nuclear spins and the environment consists of a {sup 1}H nuclear spin bath whose spectral density is close to a normal (Gaussian) distribution. We find that in the presence of such a bath, the CPMG sequence outperforms the UDD sequence. An analogy between dynamical decoupling and interference effects in optics provides an intuitive explanation as to why the CPMG sequence performs better than any nonequidistant DD sequence in the presence of this kind of environmental noise.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Wave Diagnostics and Forcing

Physical possibilities of remote diagnostics and manipulation with the state of the propagation medium by the methods of wave tomosynthesis are considered. This refers to the electromagnetic and acoustic waves as well as waves of other nature. Important are multi-position measurements with retention of phase information at each point of the medium that allows the technology of synthesizing a wide aperture with focusing to be implemented. Processing of wave projections of hidden objects makes it possible to restore their three-dimensional images. In this way, the effect of multiple wave re-reflections is reduced. In addition, the tomographic approach allows one to manipulate with the properties of the media being sounded. Thus, an increase in the radiation power at a chosen focusing point causes hyperthermia that can be used, for example, to treat oncological diseases. And creation of a minimum field and a preset phase distribution in certain regions of the medium opens the possibility of control over the motion of microparticles being trapped. The last circumstance is important, for example, for targeted delivery of medical preparations in medicine.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dual-wavelength low-coherence instantaneous phase-shifting interferometer to measure the shape of a segmented mirror with subnanometer precision

We present a noncontact optical metrology measuring the pistons and tip/tilt angles of the 61 hexagonal segments of a compact-sized segmented mirror. The instrument has been developed within the scope of a design study for the European Extremely Large Telescope (E-ELT). It is used as reference sensor for cophasing of the mirror segments in closed-loop control. The mirror shape is also measured by different types of stellar light-based phasing cameras whose performances will be evaluated with regard to a future E-ELT. Following a description of the system architecture, the second part of the paper presents experimental results demonstrating the achieved precision: 0.48 nm rms in piston and 74 nrad rms in tip/tilt.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Practicality of magnetic compression for plasma density control

Here, plasma densification through magnetic compression has been suggested for time-resolved control of the wave properties in plasma-based accelerators [P. F. Schmit and N. J. Fisch, Phys. Rev. Lett. 109, 255003 (2012)]. Using particle in cell simulations with real mass ratio, the practicality of large magnetic compression on timescales shorter than the ion gyro-period is investigated. For compression times shorter than the transit time of a compressional Alfven wave across the plasma slab, results show the formation of two counter-propagating shock waves, leading to a highly non-uniform plasma density profile. Furthermore, the plasma slab displays large hydromagnetic like oscillations after the driving field has reached steady state. Peak compression is obtained when the two shocks collide in the mid-plane. At this instant, very large plasma heating is observed, and the plasmaβ is estimated to be about 1. Although these results point out a densification mechanism quite different and more complex than initially envisioned, these features still might be advantageous in particle accelerators.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The effects of thermal manipulations during embryogenesis of broiler chicks on growth of embryo and skeletal traits

Incubation temperature is one of the important environmental factors that can induce epigenetic thermal adaptation of different physiological control systems. Thus, post hatch thermo tolerance ability of birds may be gained using these manipulations during different incubation periods. The current study was carried out to reveal the effects of temperature manipulations during early and late embryogenesis on weight of embryo and size of skeletal bilateral traits (face, wings, metatarsus, tibia, and femur) in broiler chicken embryos. One thousand commercial broiler eggs from 46 week old breeder flock were used in study. Treatments consisted of eggs incubated at 37.8°C and 55% relative humidity throughout (control; DG1), heated to 36.9°C and supplied 60% relative humidity for 6 hours daily from day 0 to 8 (DG2), heated to 36.9°C and supplied 60% relative humidity for 6 hours daily from day 10 to 18 (DG3), heated to 41°C and supplied 65% relative humidity for 3 hours daily from day 8 to 10 (DG4), and heated to 41°C and supplied 65% relative humidity for 3 hours daily from day 16 to 18 (DG5). Measurements of embryo weight and bilateral traits were obtained at 20 day of incubation and at hatch (at day 21). It was determined that the live weights of embryo and chick were affected significantly by treatment; DG3 group has shown higher mean values than the other treatment groups (P<0.05). There were differences in lengths of femur, tibia and metatarsus among treatment groups at hatch. Particularly, the high incubator temperatures at the second half of incubation accelerated growth of body and bone in embryos. These consequences of the treatments performed at different temperatures and times indicate that the different metabolic shifts realized by the embryos.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Control over Conformational Landscapes of Polypeptoids by Monomer Sequence Patterning

The ability to program chain conformation and structure through control over the monomer sequence of synthetic polymers has broad implications for next-generation material design. While related problems of protein-folding and de novo design have generated accurate predictions of 3D folded chain structures, generalization to synthetic polymers remains intractable due to the requirement of large structural databases and the intrinsically disordered nature of polymer building blocks. In this work, polypeptoids, a class of peptidomimetic synthetic polymers, are utilized to build a general workflow for the study of relationships between monomer sequence and dynamic 3D chain structure in solution. Furthermore, this work demonstrates how control over the monomer sequence can alter the conformational landscape of synthetic polymers to deviate dramatically from classical chain statistics. Specifically, the distribution of end-to-end distances, as measured by double electron-electron resonance spectroscopy in dilute solvent, is systematically skewed towards shorter distances with an increasing number of hydrophobes and further refined by hydrophobe arrangement in amphiphilic polypeptoid chains.

36 MATERIALS SCIENCE↗

Feedback-based quantum algorithms for ground state preparation

The ground state properties of quantum many-body systems are a subject of interest across chemistry, materials science, and physics. Thus, algorithms for finding ground states can have broad impacts. Variational quantum algorithms are one class of ground state algorithms that has received significant attention in recent years. These algorithms utilize a hybrid quantum-classical computing framework to prepare ground states on quantum computers. However, this requires solving a classical optimization problem that can become prohibitively expensive in high dimensions. Here, we develop formulations of feedback-based quantum algorithms for ground state preparation that can be used to address this challenge for two broad classes of Hamiltonians: Fermi-Hubbard Hamiltonians, and molecular Hamiltonians represented in second quantization. Feedback-based quantum algorithms are optimization-free; in place of classical optimization, quantum circuit parameters are set according to a deterministic feedback law derived from quantum Lyapunov control principles. This feedback law guarantees a monotonic improvement in solution quality with respect to the depth of the quantum circuit. A variety of numerical illustrations are provided that analyze the convergence and robustness of feedback-based quantum algorithms for these problem classes. Published by the American Physical Society 2024

Larsen, James B. (ORCID:000000020777440X)↗

Quantifying the impact of precision errors on quantum approximate optimization algorithms

The quantum approximate optimization algorithm (QAOA) is a hybrid quantum-classical algorithm that seeks to achieve approximate solutions to optimization problems by iteratively alternating between intervals of controlled quantum evolution. Here, we examine the effect of analog precision errors on QAOA performance from the perspective of both algorithmic training and performance guarantees. Leveraging cumulant expansions, we recast the faulty QAOA as a control problem in which precision errors are expressed as multiplicative control noise and derive bounds on the performance of QAOA. We show using both analytical techniques and numerical simulations that fixed precision implementations of QAOA circuits are subject to an exponential degradation in performance dependent upon the number of optimal QAOA layers and magnitude of the precision error. Despite this significant reduction, we show that it is possible to mitigate precision errors in QAOA via digitization of the variational parameters at the cost of increasing circuit depth.

quantum algorithms↗

Enabling Pulse-level Programming, Compilation, and Execution in XACC

Noisy gate-model quantum processing units (QPUs) are currently available from vendors over the cloud, and digital quantum programming approaches exist to run low-depth circuits on physical hardware. These digital representations are ultimately lowered to pulse-level instructions by vendor quantum control systems to affect unitary evolution representative of the submitted digital circuit. Vendors are beginning to open this pulse-level control system to the public via specified interfaces. Robust programming methodologies, software frameworks, and backend simulation technologies for this analog model of quantum computation will prove critical to advancing pulse-level control research and development. Prototypical use cases for this include error mitigation, optimal pulse control, and physics-inspired pulse construction. Here we present an extension to the XACC quantum-classical software framework that enables pulse-level programming for superconducting, gate-model quantum computers, and a novel, general, and extensible pulse-level simulation backend for XACC that scales on classical compute clusters via MPI. Our work enables custom backend Hamiltonian definitions and gate-level compilation to available pulses with a focus on performance and scalability. We end with a demonstration of this capability, and show how to use XACC for pertinent pulse-level programming tasks.

97 MATHEMATICS AND COMPUTING↗

Excitation of Bloch Surface Waves in Zero-Admittance Multilayers for High-Sensitivity Sensor Applications

The growing need for classical as well as quantum optical sensing places increasingly stringent requirements upon the desired characteristics of the engendered fields. Specifically, achieving superior field enhancement plays a critical role in applications ranging from chem-bio sensing, Raman and infrared spectroscopies to ion trapping and qubit control in emerging quantum-information science. Due to their low optical losses and ability to exhibit resonant field enhancements, all dielectric multilayers are emerging as an optical material system not only useful to classical photonics and sensing but also of potential to be integrated with quantum materials and quantum sensing. The recently introduced concept of zero-admittance layers [1] within dielectric multilayer materials, enables the creation and control of resonant fields orders of magnitude larger than the exciting field. Here, invoking the zero-admittance concept, we design, fabricate, and characterize an all-dielectric nonabsorbing stack and demonstrate the engendered huge field enhancement. Describing the fields in terms of Bloch surface waves, we connect the surface field to the semiperiodicity in the dielectric domains of the stack. As a specific application of the resonant field, we propose and demonstrate refractive-index sensing for the detection of trace amounts of an analyte. The results include a quantification of the sensitivity of the device with respect to the profile of the exciting field. The experimental results are shown to be in good agreement with theoretical calculations.

47 OTHER INSTRUMENTATION↗

Phenotype heterogeneity in cancer cell populations

Phenotype heterogeneity in cancer cell populations, be it of genetic, epigenetic or stochastic origin, has been identified as a main source of resistance to drug treatments and a major source of therapeutic failures in cancers. The molecular mechanisms of drug resistance are partly understood at the single cell level (e.g., overexpression of ABC transporters or of detoxication enzymes), but poorly predictable in tumours, where they are hypothesised to rely on heterogeneity at the cell population scale, which is thus the right level to describe cancer growth and optimise its control by therapeutic strategies in the clinic. We review a few results from the biological literature on the subject, and from mathematical models that have been published to predict and control evolution towards drug resistance in cancer cell populations. We propose, based on the latter, optimisation strategies of combined treatments to limit emergence of drug resistance to cytotoxic drugs in cancer cell populations, in the monoclonal situation, which limited as it is still retains consistent features of cell population heterogeneity. The polyclonal situation, that may be understood as “bet hedging” of the tumour, thus protecting itself from different sources of drug insults, may lie beyond such strategies and will need further developments. In the monoclonal situation, we have designed an optimised therapeutic strategy relying on a scheduled combination of cytotoxic and cytostatic treatments that can be adapted to different situations of cancer treatments. Finally, we review arguments for biological theoretical frameworks proposed at different time and development scales, the so-called atavistic model (diachronic view relying on Darwinian genotype selection in the coursof billions of years) and the Waddington-like epigenetic landscape endowed with evolutionary quasi-potential (synchronic view relying on Lamarckian phenotype instruction of a given genome by reversible mechanisms), to represent evolution towards heterogeneity, possibly polyclonal, in cancer cell populations and propose innovative directions for therapeutic strategies based on such frameworks.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time complexity and gate complexity

We formulate and investigate the simplest version of time-optimal quantum computation theory (TO-QCT), where the computation time is defined by the physical one and the Hamiltonian contains only one- and two-qubit interactions. This version of TO-QCT is also considered as optimality by sub-Riemannian geodesic length. The work has two aims: One is to develop a TO-QCT itself based on a physically natural concept of time, and the other is to pursue the possibility of using TO-QCT as a tool to estimate the complexity in conventional gate-optimal quantum computation theory (GO-QCT). In particular, we investigate to what extent is true the following statement: Time complexity is polynomial in the number of qubits if and only if gate complexity is also. In the analysis, we relate TO-QCT and optimal control theory (OCT) through fidelity-optimal computation theory (FO-QCT); FO-QCT is equivalent to TO-QCT in the limit of unit optimal fidelity, while it is formally similar to OCT. We then develop an efficient numerical scheme for FO-QCT by modifying Krotov's method in OCT, which has a monotonic convergence property. We implemented the scheme and obtained solutions of FO-QCT and of TO-QCT for the quantum Fourier transform and a unitary operator that does not have an apparent symmetry. The former has a polynomial gate complexity and the latter is expected to have an exponential one which is based on the fact that a series of generic unitary operators has an exponential gate complexity. The time complexity for the former is found to be linear in the number of qubits, which is understood naturally by the existence of an upper bound. The time complexity for the latter is exponential in the number of qubits. Thus, both the targets seem to be examples satisfyng the preceding statement. The typical characteristics of the optimal Hamiltonians are symmetry under time reversal and constancy of one-qubit operation, which are mathematically shown to hold in fairly general situations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multiple-scanning-probe tunneling microscope with nanoscale positional recognition function

Over the past decade, multiple-scanning-probe microscope systems with independently controlled probes have been developed for nanoscale electrical measurements. We developed a quadruple-scanning-probe tunneling microscope (QSPTM) that can determine and control the probe position through scanning-probe imaging. The difficulty of operating multiple probes with submicrometer precision drastically increases with the number of probes. To solve problems such as determining the relative positions of the probes and avoiding of contact between the probes, we adopted sample-scanning methods to obtain four images simultaneously and developed an original control system for QSPTM operation with a function of automatic positional recognition. These improvements make the QSPTM a more practical and useful instrument since four images can now be reliably produced, and consequently the positioning of the four probes becomes easier owing to the reduced chance of accidental contact between the probes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗