Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CODE SHARING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

TH-E-209-00: Radiation Dose Monitoring and Protocol Management

Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilities over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.

60 APPLIED LIFE SCIENCES↗

Foundations of an Electric Mobility Strategy for the City of Mexicali

The Foundations of an Electric Mobility Strategy for the city of Mexicali aligns with numerous energy, environmental, and transport plans and will help Mexicali meet multiple related goals. Mexicali’s energy mix, with 28% renewables, already enables plugin electric vehicles (PEVs) to reduce the mass of greenhouse gases (GHGs) per km driven 2/3 below that of their conventional counterparts. This GHG benefit will increase should Mexicali take steps to further increase their share of renewables in their electricity supply. Beyond increasing renewables, Mexicali could possibly deploy PEVs so that electric load is added in the right location (depending on further analysis of substations and feeders) and at the right time (between 21:00 and 11:00) in order to minimize grid upgrade costs. There are a handful of charge timing control mechanisms –at various stages of development– that Mexicali could implement. Transport electrification can facilitate mass transit by powering buses, trains, and small vehicles that get people from their homes or work to the transit stations and vice versa. Mexicali could utilize fleets as early PEV adopters in order to gain acceptance and add electric vehicle supply equipment (EVSE). Recommended prioritization of different types of fleets are suggested in this report: transit buses, school buses, airport ground support equipment (GSE), refuse trucks, taxis, shuttle buses, campus vehicles, delivery trucks, utility trucks, and finally semitrailers. There are a handful of policy options that Mexicali could use to incentivize fleets to purchase PEVs, including mandates, economic incentives, energy performance contracts, waivers to access restrictions, electricity discounts, and EVSE requirements in building codes. Mexicali’s taxi fleet was an early adopter of PEVs and had experienced some challenges—mostly related to the insufficient range of the taxis due to hot weather. In this report, we strategize ways to extend the range of the current electric taxis, including ways to make charging more convenient to the drivers, and more suggestions for appropriate vehicles to purchase in the future. This report also includes the groundwork of geotracking Mexicali’s taxi fleet so that more detailed recommendations can be made in the future. Once fleets have increased PEV acceptance and EVSE installations, the market will be ready to expand to private vehicle owners. In order to do this, more EVSE needs to be installed in the right locations. This mobility strategy lays out general local areas where EVSE could be well utilized, based on traffic patterns, land use, and demographic data. Mexicali could approach businesses within these areas that would likely make suitable hosts, based on how well they can profit from the additional business that EVSE would bring. Mexicali could then adopt a series of purchase incentives (including sales tax waivers or access to high-occupancy vehicles [HOV] lanes) that would encourage private vehicle owners to purchase PEVs. Purchase incentives run the risk of creating equity issues, which can be countered by promoting electrification in mass transit, creating more HOV lanes that have PEV exemptions, and installing EVSEs in underserved communities. Private PEV ownership will require a set of experts that Mexicali can help train, including PEV repair technicians, EVSE installation electricians, and first responders.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

MO-A-BRB-00: Electronic Charting in EBRT and Brachytherapy

The process of converting to an electronic chart for radiation therapy can be daunting. It requires a dedicated committee to first research and choose appropriate software, to review the entire documentation policy and flow of the clinic, to convert this system to electronic form or if necessary, redesign the system to more easily conform to the electronic process. Those making the conversion and those who already use electronic charting would benefit from the shared experience of those who have been through the process in the past. Therefore TG262 was convened to provide guidance on electronic charting for external beam radiation therapy and brachytherapy. This course will present the results of an internal survey of task group members on EMR practices in External Beam Radiation Therapy as well as discuss important issues in EMR development and structure for both EBRT and brachytherapy. Learning Objectives: Be familiarized with common practices and pitfalls in development and maintenance of an electronic chart in Radiation Oncology Be familiarized with important issues related to electronic charting in External Beam Radiation Therapy Be familiarized with important issues related to electronic charting in Brachytherapy.

07 ISOTOPE AND RADIATION SOURCES↗

TH-E-209-01: Fluoroscopic Dose Monitoring and Patient Follow-Up Program at Massachusetts General Hospital

Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilities over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.

60 APPLIED LIFE SCIENCES↗

TH-E-209-02: Dose Monitoring and Protocol Optimization: The Pediatric Perspective

Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilities over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.

60 APPLIED LIFE SCIENCES↗

TH-E-209-03: Development of An In-House CT Dose Monitoring and Management System Based On Open-Source Software Resources -- Pearls and Pitfalls

Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilities over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.

60 APPLIED LIFE SCIENCES↗

MO-A-BRB-03: Integration Issues in Electronic Charting for External Beam Therapy

The process of converting to an electronic chart for radiation therapy can be daunting. It requires a dedicated committee to first research and choose appropriate software, to review the entire documentation policy and flow of the clinic, to convert this system to electronic form or if necessary, redesign the system to more easily conform to the electronic process. Those making the conversion and those who already use electronic charting would benefit from the shared experience of those who have been through the process in the past. Therefore TG262 was convened to provide guidance on electronic charting for external beam radiation therapy and brachytherapy. This course will present the results of an internal survey of task group members on EMR practices in External Beam Radiation Therapy as well as discuss important issues in EMR development and structure for both EBRT and brachytherapy. Learning Objectives: Be familiarized with common practices and pitfalls in development and maintenance of an electronic chart in Radiation Oncology Be familiarized with important issues related to electronic charting in External Beam Radiation Therapy Be familiarized with important issues related to electronic charting in Brachytherapy.

07 ISOTOPE AND RADIATION SOURCES↗

MO-A-BRB-01: Review of TG-262 Internal Survey of Practices in EMR for External Beam Therapy

The process of converting to an electronic chart for radiation therapy can be daunting. It requires a dedicated committee to first research and choose appropriate software, to review the entire documentation policy and flow of the clinic, to convert this system to electronic form or if necessary, redesign the system to more easily conform to the electronic process. Those making the conversion and those who already use electronic charting would benefit from the shared experience of those who have been through the process in the past. Therefore TG262 was convened to provide guidance on electronic charting for external beam radiation therapy and brachytherapy. This course will present the results of an internal survey of task group members on EMR practices in External Beam Radiation Therapy as well as discuss important issues in EMR development and structure for both EBRT and brachytherapy. Learning Objectives: Be familiarized with common practices and pitfalls in development and maintenance of an electronic chart in Radiation Oncology Be familiarized with important issues related to electronic charting in External Beam Radiation Therapy Be familiarized with important issues related to electronic charting in Brachytherapy.

07 ISOTOPE AND RADIATION SOURCES↗

MO-A-BRB-02: Considerations and Issues in Electronic Charting for Brachytherapy

The process of converting to an electronic chart for radiation therapy can be daunting. It requires a dedicated committee to first research and choose appropriate software, to review the entire documentation policy and flow of the clinic, to convert this system to electronic form or if necessary, redesign the system to more easily conform to the electronic process. Those making the conversion and those who already use electronic charting would benefit from the shared experience of those who have been through the process in the past. Therefore TG262 was convened to provide guidance on electronic charting for external beam radiation therapy and brachytherapy. This course will present the results of an internal survey of task group members on EMR practices in External Beam Radiation Therapy as well as discuss important issues in EMR development and structure for both EBRT and brachytherapy. Learning Objectives: Be familiarized with common practices and pitfalls in development and maintenance of an electronic chart in Radiation Oncology Be familiarized with important issues related to electronic charting in External Beam Radiation Therapy Be familiarized with important issues related to electronic charting in Brachytherapy.

07 ISOTOPE AND RADIATION SOURCES↗

Radionuclide Emission Estimation for the Center for Advanced Energy Studies (CAES)

An Radiological Safety Analysis Computer Program (RSAC)-7 model dose assessment was performed to evaluate maximum Center for Advanced Energy Studies (CAES) boundary effective dose equivalent (EDE, in mrem/yr) for potential individual releases of radionuclides from the facility. The CAES is a public/private partnership between the State of Idaho and its academic research institutions, the federal government through the U.S. Department of Energy (DOE), and the Idaho National Laboratory (INL) managed by the Battelle Energy Alliance (BEA). CAES serves to advance energy security for our nation by expanding educational opportunities at Idaho universities in energy-related areas, creating new capabilities within its member institutions, and delivering technological innovations leading to technology-based economic development for the intermountain region. CAES has developed a strategic plan (INL/EXT-07-12950) based on the balanced scorecard approach. At the present time it is unknown exactly what processes will be used in the facility in support of this strategic plan. What is known is that the Idaho State University (ISU) Radioactive Materials License (Nuclear Regulatory Commission [NRC] license 11-27380-01) is the basis for handling radioactive material in the facility. The material in this license is shared between the ISU campus and the CAES facility. There currently are no agreements in place to limit the amount of radioactive material at the CAES facility or what is done to the material in the facility. The scope of this analysis is a summary look at the basis dose for each radionuclide included under the license at a distance of 100, 500, and 1,000 m. Inhalation, ingestion and ground surface dose was evaluated using the NRC design basis guidelines. The results can be used to determine a sum of the fractions approach to facility safety. This sum of the fractions allows a facility threshold value (TV) to be established and potential activities to be evaluated against this TV.

61 RADIATION PROTECTION AND DOSIMETRY↗

PROcess Based Diagnostics PROBE

Many of the aspects of the climate system that are of the greatest interest (e.g., the sensitivity of the system to external forcings) are emergent properties that arise via the complex interplay between disparate processes. This is also true for climate models most diagnostics are not a function of an isolated portion of source code, but rather are affected by multiple components and procedures. Thus any model-observation mismatch is hard to attribute to any specific piece of code or imperfection in a specific model assumption. An alternative approach is to identify diagnostics that are more closely tied to specific processes -- implying that if a mismatch is found, it should be much easier to identify and address specific algorithmic choices that will improve the simulation. However, this approach requires looking at model output and observational data in a more sophisticated way than the more traditional production of monthly or annual mean quantities. The data must instead be filtered in time and space for examples of the specific process being targeted.We are developing a data analysis environment called PROcess-Based Explorer (PROBE) that seeks to enable efficient and systematic computation of process-based diagnostics on very large sets of data. In this environment, investigators can define arbitrarily complex filters and then seamlessly perform computations in parallel on the filtered output from their model. The same analysis can be performed on additional related data sets (e.g., reanalyses) thereby enabling routine comparisons between model and observational data. PROBE also incorporates workflow technology to automatically update computed diagnostics for subsequent executions of a model. In this presentation, we will discuss the design and current status of PROBE as well as share results from some preliminary use cases.

PROBE↗

A composite position independent monitor of reactor fuel irradiation using Pu, Cs, and Ba isotope ratios

When post-irradiation materials from the nuclear fuel cycle are released to the environment, certain isotopes of actinides and fission products carry signatures of irradiation history that can potentially aid a nuclear forensic investigation into the material's provenance. In this study, combinations of Pu, Cs, and Ba isotope ratios that produce position (in the reactor core) independent monitors of irradiation history in spent light water reactor fuel are identified and explored. These position independent monitors (PIMs) are modeled for various irradiation scenarios using automated depletion codes as well as ordinary differential equation solutions to approximate nuclear physics models. Experimental validation was performed using irradiated low enriched uranium oxide fuel from a light water reactor, which was sampled at 8 axial positions from a single rod. Plutonium, barium and cesium were chemically separated and isotope ratio measurements of the separated solutions were made by quadrupole and multi-collector inductively coupled mass spectrometry (Cs and Pu, respectively) and thermal ionization mass spectrometry (Ba). The effect of axial variations in neutron fluence and energy spectrum are evident in the measured isotope ratios. Furthermore, two versions of a combined Pu and Cs based PIM are developed. A linear PIM model, which can be used to solve for irradiation time is found to work well for natural U fuel with <10% 240 Pu and known or short cooling times. A non-linear PIM model, which cannot be solved explicitly for irradiation time without additional information, can nonetheless still group samples by irradiation history, including high burnup LEU fuel with unknown cooling time. 137 Ba/ 138 Ba is also observed to act as a position independent monitor; it is nearly single valued across the sampled fuel rod, indicating that samples sharing an irradiation history (same irradiation time and cooling time) in a reactor despite experiencing different neutron fluxes will have a common 137 Ba/ 138 Ba ratio. Modeling of this Ba PIM shows it increases monotonically with irradiation and cooling time, and a confirmatory first order analytical solution is also presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Massively Parallel Adaptive Fast Multipole Method on Heterogeneous Architectures

We describe a parallel fast multipole method (FMM) for highly nonuniform distributions of particles. We employ both distributed memory parallelism (via MPI) and shared memory parallelism (via OpenMP and GPU acceleration) to rapidly evaluate two-body nonoscillatory potentials in three dimensions on heterogeneous high performance computing architectures. We have performed scalability tests with up to 30 billion particles on 196,608 cores on the AMD/CRAY-based Jaguar system at ORNL. On a GPU-enabled system (NSF's Keeneland at Georgia Tech/ORNL), we observed 30x speedup over a single core CPU and 7x speedup over a multicore CPU implementation. By combining GPUs with MPI, we achieve less than 10 ns/particle and six digits of accuracy for a run with 48 million nonuniformly distributed particles on 192 GPUs.

99 GENERAL AND MISCELLANEOUS↗

System-Level Reuse of Space Systems Simulations

One of the best ways to enhance space systems simulation fidelity is to leverage off of (reuse) existing high-fidelity simulations. But what happens when the model you would like to reuse is in a different coding language or other barriers arise that make one want to just start over with a clean sheet of paper? Three diverse system-level simulation reuse case studies are described based on experience to date in the development of NASA's Space Station Training Facility (SSTF) at the Johnson Space Center in Houston, Texas. Case studies include (a) the Boeing/Rocketdyne-provided Electrical Power Simulation (EPSIM), (b) the NASA Automation and Robotics Division-provided TRICK robotics systems model, and (c) the Russian Space Agency- provided Russian Segment Trainer. In each case, there was an initial tendency to dismiss simulation reuse candidates based on an apparent lack of suitability. A more careful examination based on a more structured assessment of architectural and requirements-oriented representations of the reuse candidates revealed significant reuse potential. Specific steps used to conduct the detailed assessments are discussed. The steps include the following: 1) Identifying reuse candidates; 2) Requirements compatibility assessment; 3) Maturity assessment; 4) Life-cycle cost determination; and 5) Risk assessment. Observations and conclusions are presented related to the real cost of system-level simulation component reuse. Finally, lessons learned that relate to maximizing the benefits of space systems simulation reuse are shared. These concepts should be directly applicable for use in the development of space systems simulations in the future.

Hazen, Michael R.↗

Towards Vendor and Operating System Independence of USB-based portable multi-channel analyzers

The nuclear measurements group is called on to develop portable, user friendly systems that performs at, or near, laboratory standards. These systems typically consist of a detector and a USB-based multi-channel analyzer. An ORTEC digi-Base is an example of a USB-based portable multi-channel analyzer with 14-pin photomultiplier tube base for gamma-ray spectroscopy applications with NaI(Tl) and other scintillation detectors. Operating system independence - we want to be able to develop applications that are 'future-proof' and can run on the best hardware for the job: desktop, laptop, tablet, phone, or embedded device. To do that we need our software to be operating system independent. Hardware vendor independence - to use the most appropriate equipment for the job, while still maintaining our rapid method development, we would like our software that uses this equipment to be independent of the specific vendor or model of the hardware. To do that we need a common interface to each vendor's equipment (high voltage, gain, start, stop, clear, etc.) In prior work, we were able to use an existing library to communicate with an ORTEC digi-base via Linux and Android. However the application developed did not have a user friendly front-end. Part of this work was to develop a simple user interface to control the settings of the hardware from Android. While OS independence is the final goal, another goal is standardized software for user-application development. For current purposes those standard systems are Windows 7, Windows 10, and Python 3. Our next step was to develop a common software interface between a front-end user interface and back-end hardware communication software. This was done using Python's Ctypes library. Ctypes is a foreign function library for Python. It provides C compatible data types, and allows calling functions in DLLs or shared libraries. It can be used to wrap these libraries in pure Python. Ctypes exports the cdll, and Windows windll and oledll objects, for loading dynamic link libraries. You load libraries by accessing them as attributes of these objects. cdll loads libraries which export functions using the standard cdecl calling convention. The first steps of developing the common software interface have been done. Once the software interface has been developed the next goal will be to develop hardware specific back-end software that way rapid user facing software can be developed using equipment that is 'on-hand' and once finished prototyping, the 'best' hardware can be chosen for the specific implementation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Measured and Predicted Acoustics From an XV-15 Flight Test

Flight acoustic and vehicle state data from an XV-15 acoustic flight test are examined. Flight predictions using TiltRotor Aeroacoustic Code (TRAC) are performed for a level flight (repeated) and four descent conditions (including a blade vortex interaction (BVI)). The assumptions and procedures used for TRAC flight predictions as well as the variability in flight measurements, which are used for input and comparison to predictions, are investigated in detail. Differences were found in the measured vehicle airspeed, altitude, glideslope, and vehicle orientation (yaw, pitch, and roll angle) between each of the repeat runs. These differences violate some of the prediction assumptions and significantly impacted the resulting acoustic predictions. Multiple acoustic pulses, with a variable time between the pulses, were found in the measured acoustic time histories for the repeat runs. These differences could be attributed in part to the variability in vehicle orientation. Acoustic predictions that used the measured vehicle orientation for the repeat runs captured this multiple pulse variability. Thickness noise was found to be dominant on approach for all the cases, except the BVI condition. After the aircraft passed overhead, broadband noise and low frequency loading noise were dominant. The predicted LowSPL time histories compared well with measurement on approach to the array for the non-BVI conditions and poorly for the BVI condition. Accurate prediction of the lift share between the rotor and fuselage must be known in order to improve predictions. At a minimum, measurements of the rotor thrust and tip-path-plane angle are critical to further develop accurate flight acoustic prediction capabilities.

Boyd, D. Douglas, Jr.↗

Rough-Wall Channel Analysis Using Suboptimal Control Theory

The original aim of this work was to shed some light on the physics of turbulence over rough walls using large-eddy simulations and the suboptimal-control wall boundary conditions introduced by Nicoud et al. It was hoped that, if that algorithm was used to fit the mean velocity profile of the simulations to that of a rough-walled channel, instead of to a smooth one, the wall stresses introduced by the control algorithm would give some indication of what aspects of rough walls are most responsible for the modification of the flow in real turbulence. It was similarly expected that the structure of the resulting velocity fluctuations would share some of the characteristics of rough-walled flows, thus again suggesting what is intrinsic and what is accidental in the effect of geometric wall roughness. A secondary goal was to study the effect of 'unphysical' boundary conditions on the outside flow by observing how a relatively major change of the target velocity profile, and therefore presumably of the applied wall stresses, modifies properties such as the dominant length scales of the velocity fluctuations away from the wall. As will be seen below, this secondary goal grew more important during the course of the study, which was carried out during a short summer visit of the first two authors to the CTR. It became clear that there are open questions about the way in which the control algorithm models the boundary conditions, even for smooth walls, and that these questions make the physical interpretation of the results difficult. Considerable more work in that area seems to be needed before even relatively advanced large-eddy simulations, such as these, can be used to draw conclusions about the physics of wall-bounded turbulent flows. The numerical method is the same as in Nicoud et al. The modifications introduced in the original code are briefly described in section 2, but the original paper should be consulted for a full description of the algorithm. The results are presented in section 3 and summarized in section 4. The elementary properties of turbulence over rough walls which are used in the text have been taken from recent reviews such as Raupach et al. or Jimenez.

Flores, O.↗

Early Experience with Out-of-Core Applications on the Cray XMT

This paper describes early experience with a preproduction Cray XMT system that implements a scalable shared memory architecture with hardware support for multithreading. Unlike its predecessor, the Cray MTA-2 that had very limited I/O capability, the Cray XMT offers Lustre, a scalable high-performance parallel filesystem. Therefore it enables development of out-of-core applications that can deal with very large data sets that otherwise would not fit the system main memory. Our application performs statistically-based anomaly detection for categorical data that can be used for Internet traffic analysis. Our results indicate that the preproduction version of the machine is able to achieve good performance and scalability for the in-and out-of-core versions of the example application.

97 MATHEMATICS AND COMPUTING↗