Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Balloon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Results of the 1994 NASA/JPL balloon flight solar cell calibration program

The 1994 solar cell calibration balloon flight was completed on August 6, 1994. All objectives of the flight program were met. Thirty-seven modules were carried to an altitude of 119,000 ft (36.6 km). Data telemetered from the modules was corrected to 28 C and to 1 AU. The calibrated cells have been returned to the 6 participants and can now be used as reference standards in simulator testing of cells and arrays.

Anspaugh, B. E.↗

Long duration biaxial cylinder testing of balloon grade polyethylene films with emphasis on automated data acquisition and control

Characterization of a 2-dimensional material constitutive model in the practical biaxial state for engineering utility of balloon envelope structural analysis is achievable with laboratory cylinder tests. Hoop (circumferential, and longitudinal strains are time-wise measured on axially loaded pressurized cylinders. Pre-programmed ramped loading changes as well as precise long term pressure control are achieved through cascaded proportional, integral derivative (PID) flow control loops that are part of an integrated data acquisition and process control system. Real time data reduction and analysis allow monitoring of unattended tests that have durations of up to a month. Measured and controlled parameters and variables are discussed; date analysis techniques are reviewed.

Martone, Michael↗

Characterization of path effects on the properties of balloon films

The effect of stress and temperature path on the mechanical properties of a balloon film material (Astrofilm E2) have been studied using two techniques. The first technique is based on uniaxial tensile measurements of prestrained strips of the film as a function of temperature. Data are analyzed in terms of two temperature coefficients, defined here as a stiffness coefficient and a strength coefficient; and by comparing the areas under the stress-strain curves. The second technique investigated the effect of stress and temperature path on inflated cylinders of the same material. The changes in the mechanical properties due to preconditioning in the biaxial stress state were evaluated using the ball burst test. Preliminary findings indicate that the material is stress and temperature path dependent. Changes in stiffness coefficient, draw strength and toughness were measured and discussed. The above techniques may be suitable to document path dependent changes, and to discriminate among films of different manufacture.

Said, Magdi A.↗

Balloon profiles of stratospheric NO2 and HNO3 for testing the heterogeneous hydrolysis of N2O5 on sulfate aerosols

Simultaneous in situ measurements of stratospheric NO2, HNO3, HCl, and CH4 from 34 to 24 km were made in August 1992 from Palestine, Texas, using the Balloon-borne Laser In-Situ Sensor (BLISS) tunable diode laser spectrometer. Although the measurements of NO2, HNO3, and NO2/HNO3 agree well with gas-phase model calculations near 34 km where Stratospheric Aerosol and Gas Experiment (SAGE) 2 data show little sulfate aerosol, this is not true at the lower altitudes where SAGE 2 shows high aerosol loadings. At 24 km the BLISS NO2 and HNO3 measurements are 70% lower and 50% higher, respectively, than the gas phase model predictions, with a measured NO2/HNO3 ratio 5 times smaller. When the heterogeneous hydrolysis of N2O5 and ClONO2 on sulfate aerosol of surface area densities matching the SAGE 2 measurements is added to the model, good agreement with the BLISS measurements is found over the whole altitude range.

Webster, C. R.↗

The solar diameter and oblateness measured by the solar disk sextant on the 1992 September 30 balloon flight

This paper reports the results of a balloon flight of the Solar Disk Sextant (SDS) on 1992 September 30. This was the first flight in which the SDS used a wedge assembly fabricated by molecular contact in order to eliminate the wedge angle variations observed in previous flights. The instrument performed as designed. The main results obtained are values of the solar diameter for a number of discrete heliocentric latitudes, and the solar oblateness. The accuracy of the diameter values is better than 0.2 sec whereas the precision is approximately 1-2 mas. The equatorial solar diameter, at 1 AU, was 1919.06 sec +/- 0.12 sec, and the oblateness epsilon = 8.63 +/- 0.88 x 10(exp -6).

Sofia, S.↗

Balloon-borne measurements of ClO, NO, and O3 in a volcanic cloud: An analysis of heterogeneous chemistry between 20 and 30 km

Balloon profiles of chlorine monoxide (ClO), nitric oxide (NO), and ozone (O3) were measured on March 11, 1992 from 100 to 10 mb over Greenland (67.0 deg N, 50.6 deg W). Measurements from SAGE II indicate that the aerosol surface area in the region was enhanced by sulfur from the eruption of Mt. Pinatubo, reaching 50 times background near 20 km. Concentrations of ClO were enhanced and concentrations of NO were suppressed relative to low aerosol conditions consistent with the effects of hydrolysis of N2O5 on the surface of sulfuric acid aerosols. The data are consistent with a value of 2 x 10(exp -4) for the reaction probability of the heterogeneous hydrolysis of ClONO2, indicating a minor role for this reaction at as temperature of 220 K. At these temperatures, we find no evidence for the catastrophic loss of ozone predicted to occur under conditions of enhanced aerosol surface area.

Dessler, A. E.↗

Balloon-borne measurements of the SN 1987A hard X-ray continuum

SN 1987A hard X-ray continuum spectra obtained on 1987 October 29, 1988 April 9-10, and 1988 November 11 from balloon-flight measurments are presented. The spectra, spanning the energy range from 25 keV to 300 keV, have been analyzed using a detector response matrix inversion technique that converts the spectra form counts/s/sq cm keV to photons/s/sq cm keV allowing direct comparison with theoretical models. The results indicate that the bulk of the (56)Co is mixed moderately through the inner regions of the supernova envelope but they do not preclude the mixing of a small amount of the (56)Co farther out into the envelope necessary to account for the observed (56)Co line fluxes. The effect of the ratio (57)Co to (56)Co on the 1988 November 11 continuum spectrum is discussed.

Pendleton, Geoffrey N.↗

Balloon-borne observations of mid-latitude hydrofluoric acid

Measurements of stratospheric hydrofluoric acid (HF) have been made by the JPL MkIV interferometer during high-altitude balloon flights. Infrared solar absorption spectra were acquired near 35 deg N at altitudes between local tropopause and 38 km. Volume mixing ratio profiles of HF derived from 4 flights (1990-93), in conjunction with simultaneously observed N2O profiles, indicate an average rate of HF increase of (5.5 +/- 0.3)% per year, in agreement with time-dependent, two-dimensional model simulations (6% per year) and ATMOS measurements.

Sen, B.↗

Virginia Space Grant Consortium Upper Atmospheric Payload Balloon System (Vps)

This document provides a summary of the launch and post-launch activities of Virginia Space Grant Consortium Upper Atmospheric Payload Balloon System, V(ps). It is a comprehensive overview covering launch activities, post-launch activities, experimental results, and future flight recommendations.

Marz, Bryan E.↗

High Energy Antimatter Telescope (HEAT) Balloon Experiment

This grant supported our work on the High Energy Antimatter Telescope(HEAT) balloon experiment. The HEAT payload is designed to perform a series of experiments focusing on the cosmic ray positron, electron, and antiprotons. Thus far two flights of the HEAT -e+/- configuration have taken place. During the period of this grant major accomplishments included the following: (1) Publication of the first results of the 1994 HEAT-e+/- flight in Physical Review Letters; (2) Successful reflight of the HEAT-e+/- payload from Lynn Lake in August 1995; (3) Repair and refurbishment of the elements of the HEAT payload damaged during the landing following the 1995 flight; and (4) Upgrade of the ground support equipment for future flights of the HEAT payload.

Beatty, J. J.↗

Results of the 1996 JPL Balloon Flight Solar Cell Calibration Program

The 1996 solar cell calibration balloon flight campaign was completed with the first flight on June 30, 1996 and a second flight on August 8, 1996. All objectives of the flight program were met. Sixty-four modules were carried to an altitude of 120,000 ft (36.6 km). Full 1-5 curves were measured on 22 of these modules, and output at a fixed load was measured on 42 modules. This data was corrected to 28 C and to 1 AU (1.496 x 10(exp 8) km). The calibrated cells have been returned to the participants and can now be used as reference standards in simulator testing of cells and arrays.

Anspaugh, B. E.↗

Balloon-Borne Measurements of CLO, NO and O3 in a Volcanic Cloud: An Analysis of Heterogeneous Chemistry between 20 and 30 KM

Balloon profiles of chlorine monoxide (ClO), nitric oxide (NO), and ozone (O3) were measured on March 11, 1992 from 100 to 10 mb over Greenland (67.0 deg N, 50.6 deg W). Measurements from SAGE II indicate that the aerosol surface area in the region was enhanced by sulfur from the eruption of Mt. Pinatubo, reaching 50 times background near 20 km. Concentrations of ClO were enhanced and concentrations of NO were suppressed relative to low aerosol conditions consistent with the effects of hydrolysis of N2O5 on the surface of sulfuric acid aerosols. The data are consistent with a value of 2 x 10(exp -4) for the reaction probability of the heterogeneous hydrolysis of ClONO2, indicating a minor role for this reaction at a temperature of 220 K. At these temperatures, we find no evidence for the catastrophic loss of ozone predicted to occur under conditions of enhanced aerosol surface area.

Dessler, A. E.↗

Development of an Energetic X-Ray Imaging Telescope Experiment (EXITE) and Associated Balloon Gondola System

This is the Final Report for grant NAGW-624, which was our original grant to develop the Energetic X- ray Imaging Telescope Experiment (EXITE) and Associated Balloon Gondola. The EXITE grant was changed over to a new grant (from GSFC), NAG5-5103, beginning in FY97 and is currently very much continuing under that grant. The Final Report presented here then covers the EXITE development under the original grant, which in fact continued (with a 1 year no-cost extension) through December 31, 1997.

Source record↗

Balloon-Borne Measurements of Stratospheric Radicals and their Precursors: Implications for the Production and Loss of Ozone

Measurements of hydrogen, nitrogen and chlorine radicals from a balloon flight on 25 September 1993 from Ft. Sumner, NM provide an opportunity to quantify photochemical production and loss of stratospheric ozone. Ozone loss rates determined using measured radical concentrations agree fairly well with loss rates calculated using a photochemical model. Catalytic cycles involving OH and HO2 are shown to dominate photochemical loss of ozone for altitudes between 44 and 50 km. Reactions involving NO and NO2 are the dominant sink for ozone between 25 and 38 km. The total ozone loss rate determined from the measurements balances calculated production rates for altitudes between 30 and 40 km. However, loss of ozone exceeds production by -35% between 42 and 50 km. The imbalance between production and loss of ozone above 42 km is larger than the uncertainty of any one of the critical kinetic parameters or species concentrations. No single adjustment to any of these parameters can simultaneously resolve the imbalance and satisfy constraints imposed by measured OH, HO2, NO2 and ClO. Our results are consistent with an additional mechanism for ozone production above 40 km other than photolysis of ground state O2.

Osterman, G. B.↗

Results of the 1997 JPL Balloon Flight Solar Cell Calibration Program

The 1997 solar cell calibration balloon flight campaign consisted of three flights, the first flight on June 11, 1997, the second flight on August 2, 1997, and the third flight on August 24, 1997. One flight, flown on August 14, 1997, was terminated early because of a telemetry transmitter failure, and its payload was reflown on the August 24 flight. All objectives of the flight program were met. Ninety-eight modules were carried to an altitude of approximately 120,000 ft (36.6 km). Full I-V curves were measured on 32 of these modules, and output at a fixed load was measured on 66 modules. This data was corrected to 28 C and to 1 AU (1.496 x 10(exp 8) km). The calibrated cells have been returned to the participants and can now be used as reference standards in simulator testing of cells and arrays.

Anspaugh, B. E.↗

Results of the 1998 JPL Balloon Flight Solar Cell Calibration Program

The 1998 solar cell calibration balloon flight campaign consisted of one flight, which occurred on August 15, 1998. All objectives of the flight program were met. Thirty-one modules were carried to an altitude of = 120,000 ft (36.6 km). Full I-V curves were measured on 4 of these modules, and output at a fixed load was measured on 27 modules. This data was corrected to 28 C and to 1 AU (1.496 x 10(exp 8) km). The calibrated cells have been returned to the participants and can now be used as reference standards in simulator testing of cells and arrays.

Anspaugh, B. E.↗