Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BLOOD VESSELS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Optical and electrical characterization of an atmospheric pressure microplasma jet with a capillary electrode

A microplasma jet with a capillary electrode working at atmospheric pressure is developed to create nonthermal plasma. This jet can be operated at an excitation frequency either in several tens of kilohertz ac range (or pulsed voltage with a repetition rate of kilohertz range) or in radio-frequency range. The working gas, helium or argon, and the additive gas, oxygen, are fed into the plasma jet. The discharge has been characterized by optical emission spectroscopy. The electrical property of the discharge has been studied by means of voltage and current probes. The dynamic nature of the plume is investigated by using intensified charged coupled device camera. The electron temperature is estimated from the modified Boltzmann plot method utilizing the Ar 4p->4s transitions. The plume temperature is determined by using the fitting the fine structure of the emission bands of OH molecules and by utilizing the line shape of the transition. They are compared with the results obtained by optical fiber thermometer. The characteristics of plasma jet are studied by employing different excitation mode and by adjusting the gas flow rates, the applied voltage, and the amount of additive O{sub 2} flow. The characteristic differences between the Ar plasma jet and the He plasma jet are compared. The effects of the additive O{sub 2} gas are investigated. The plasma bullet velocity is found to increase with the applied voltage but to decrease with the duty cycle. Also the preliminary results of microplasma effects on the human breast cancer cells are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Glass Monocapillary X-ray Optics And Their Applications In X-ray Microscopy

Elliptical, parabolic and Wolter type glass monocapillaries were fabricated for use as x-ray condensers in the energy range of 250 eV to 20 keV. On a routine basis a diameter error of +/-0.4 {mu}m and straightness error of 0.8 {mu}m (peak to valley) can be reached. The final test of condensers was performed at-wavelength by imaging the far field x-ray reflection intensity distribution using a laboratory microfocus x-ray source. For medium length condensers with a total length <80 mm, a total slope error of 40 murad rms was obtained. The applications in full-field x-ray microscopes and the future effort in developing capillary Wolter mirrors based on this technology are reported.

07 ISOTOPE AND RADIATION SOURCES↗

Temporal evolution of electron density and temperature in capillary discharge plasmas

Time-resolved spectroscopic measurements of a capillary discharge plasma of helium gas were carried out to obtain detailed information about dynamics of the discharge plasma column, where the fast plasma dynamics is determined by the electron density and temperature. Our measurements show that the electron density of the capillary plasma column increases sharply after gas breakdown and reaches its peak of the order of 10{sup 18} cm{sup -3} within less than 100 ns, and then it decreases as time goes by. The result indicates that a peak electron density of 2.3x10{sup 18} cm{sup -3} occurs about 65 ns after formation of the discharge current, which is ideal for laser wakefield acceleration experiments reported by Karsch et al. [New J. Phys. 9, 415 (2007)].

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interferometer density measurements of a high-velocity plasmoid

The plasmoid produced by a half-scale contoured gap coaxial plasma accelerator using ablative polyethylene capillary plasma injectors is measured using a quadrature heterodyne HeNe interferometer. The plasmoid is found to have a sharp rise in density at the leading edge, with a gradual falloff after the peak density. For this early test series, an average bulk density of 5x10{sup 14} cm{sup -3} is observed, with densities up to 8x10{sup 14} cm{sup -3} seen on some shots. Although plasmoid mass is only about 58 mug due to the low current and injected mass used in these tests, good shot-to-shot repeatability is attained making analysis relatively straightforward, thus providing a solid foundation for interpreting future experimental results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparisons of kinetic ablation models for the capillary discharge

The properties of kinetic ablation models are considered in this paper. The widely used kinetic ablation model (model-K) only considers monatomic vapor. A revised model (model-Z) was introduced by taking into account the polyatomic vapor's internal degrees of freedom, as well as the temperature dependence of the average particle mass. In this work, both temperature and pressure dependence of average particle mass and the specific heat ratio {gamma} are taken into account, producing an improved version of model-Z (denoted model-Z{sup *}). Ablation data calculated by model-K and model-Z* for two typical capillary materials are presented. Compared to model-K, model-Z* predicts an increased ablation rate at lower plasma temperature and higher plasma density, and a decreased rate for the opposite conditions. Finally, based on the plasma parameters in a typical discharge cycle, all three models are used to calculate the time-dependent ablation rate and the integrated ablated mass. It is found that the main difference between their results arises because of the different average particle masses near the wall surface, and model-Z* is the most accurate for the discharge cycle considered. Further, it is found that the ablation parameters are highly sensitive to the pressure, in particular, through the pressure dependence of average particle mass.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Product gas evolution above planar microstructured model catalysts--A combined scanning mass spectrometry, Monte Carlo, and Computational Fluid Dynamics study

The transport and distribution of reaction products above catalytically active Pt microstructures was studied by spatially resolved scanning mass spectrometry (SMS) in combination with Monte Carlo simulation and fluid dynamics calculations, using the oxidation of CO as test reaction. The spatial gas distribution above the Pt fields was measured via a thin quartz capillary connected to a mass spectrometer. Measurements were performed in two different pressure regimes, being characteristic for ballistic mass transfer and diffusion involving multiple collisions for the motion of CO{sub 2} product molecules between the sample and the capillary tip, and using differently sized and shaped Pt microstructures. The tip height dependent lateral resolution of the SMS measurements as well as contributions from shadowing effects, due to the mass transport limitations between capillary tip and sample surface at close separations, were evaluated and analyzed. The data allow to define measurement and reaction conditions where effects induced by the capillary tip can be neglected (''minimal invasive measurements'') and provide a basis for the evaluation of catalyst activities on microstructured model systems, e.g., for catalyst screening or studies of transport effects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microangiography in Living Mice Using Synchrotron Radiation

Traditionally, there are no methods available to detect the fine morphologic changes of cerebrovasculature in small living animals such as rats and mice. Newly developed synchrotron radiation microangiography can achieve a fine resolution of several micrometers and had provided us with a powerful tool to study the cerebral vasculature in small animals. The purpose of this study is to identify the morphology of cerebrovasculature especially the structure of Lenticulostriate arteries (LSAs) in living mice using the synchrotron radiation source at Shanghai Synchrotron Radiation Facility (SSRF) in Shanghai, China. Adult CD-1 mice weighing 35-40 grams were anesthetized. Nonionic iodine (Omnipaque, 350 mg I /mL) was used as a contrast agent. The study was performed at the BL13W1 beam line at SSRF. The beam line was derived from a storage ring of electrons with an accelerated energy of 3.5 GeV and an average beam current of 200 mA. X-ray energy of 33.3 keV was used to produce the highest contrast image. Images were acquired every 172 ms by a x-ray camera (Photonic-Science VHR 1.38) with a resolution of 13 {mu}m/pixel. The optimal dose of contrast agent is 100 {mu}l per injection and the injecting rate is 33 {mu}l/sec. The best position for imaging is to have the mouse lay on its right or left side, with ventral side facing the X-ray source. We observed the lenticulostriate artery for the first time in living mice. Our result show that there are 4 to 5 lenticulostriate branches originating from the root of middle cerebral artery in each hemisphere. LSAs have an average diameter of 43{+-}6.8 {mu}m. There were no differences between LSAs from the left and right hemisphere (p<0.05). These results suggest that synchrotron radiation may provide a unique tool for experimental stroke research.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Plasma Diagnostics of a Capillary Plasma Channel for Laser Guiding

We demonstrated the production of an optical waveguide in a capillary discharge-produced plasma using a cylindrical capillary. Plasma parameters of its waveguide were characterized by use of both a Normarski laser interferometer and a hydrogen plasma line spectrum. A space-averaged maximum temperature of 3.3 eV with electron densities of the order of 10{sup 17} cm{sup -3} was observed at a discharge time of 150 ns and a maximum discharge current of 200 A. An ultrashort, intense laser pulse was guided by use of this plasma channel.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Resonant Excitation of Plasma Wakefields

We describe characteristics of the bunch train and plasma source used in a resonant plasma wakefield experiment at the Brookhaven National Laboratory Accelerator Test Facility. The bunch train has the proper correlated spread to unambiguously observe the expected energy gain by the witness bunch at resonance. The plasma density in the capillary discharge is sufficiently high to reach the resonance with the typical bunch train spacing of this experiment. It is also uniform over more than 3/4 of the 2 cm-long capillary.

43 PARTICLE ACCELERATORS↗

Simulation of Current Filamentation Instability for an Accelerator Beam in a Capillary Plasma

Current Filamentation Instability (CFI) is of central importance for the propagation of relativistic electron beams in plasmas. It could play an important role in the generation of magnetic fields and of radiation in the after-glow of gamma ray bursts as well as in hot electrons energy transport in the fast-igniter inertial confinement fusion concept. Using the particle-in-cell code QuickPIC, simulations of the electron beam at the Brookhaven National Laboratory--Accelerator Test Facility, BNL-ATF, propagating in a cm-long plasma were conducted. Simulation results show that with beam and plasma parameters achievable at the BNL-ATF, the CFI should be observed within 2 cm of plasma. Simulation results are presented for an experiment currently underway at BNL-ATF and possible diagnostics for characterizing the instability are discussed.

43 PARTICLE ACCELERATORS↗

Microdischarge extreme ultraviolet source with alkali metal vapor for surface morphology application

We have characterized a discharge-produced potassium plasma extreme ultraviolet (XUV) source. Potassium ions produced strong broadband emission around 40 nm with a bandwidth of 8 nm (full width at half-maximum). By comparison with atomic structure calculations, the broadband emission is found to be primarily due to 3d-3p transitions in potassium ions ranging from K{sup 2+} to K{sup 4+}. The current-voltage characteristics of the microdischarge suggest that the source operates in a hollow cathode mode and consequently the emitting ions may be localized on the potassium electrode surface at the hole into the capillary. To understand the spectral behavior from the potassium plasmas we compared the spectra from the discharge-produced plasma with that from a laser-produced plasma. The spectra from the different (electric and laser) plasmas at the same electron temperature (12 eV) were almost the same. This compact capillary XUV source with a photon energy of 30 eV is a useful XUV emission source for surface morphology applications.

74 ATOMIC AND MOLECULAR PHYSICS↗

Fabrication of Impregnated-Electrode-Type Polyatomic Ion Source with Ionic Liquid

Three types of ionic liquid ion source characterized by needle-type, capillary-needle-type and impregnated-electrode-type emitters were fabricated and demonstrated. The ion emission of a pure ionic liquid was demonstrated for the capillary-needle- and impregnated-electrode-type emitters. The emission stability of the impregnated-electrode-type emitter is currently insufficient for the shallow implantation of carbon due to occasional discharge. However, the impregnated-electrode-type emitter showed the largest emission current of 14 {mu}A at 6 kV among these emitters. This was considered to be caused by the relatively high feedability of the ionic liquid obtained from the emitter tip made of porous copper.

43 PARTICLE ACCELERATORS↗

Micro-nano scale ripples on metallic glass induced by laser pulse

A Zr{sub 47.7}Cu{sub 31}Ni{sub 9}Al{sub 12.3} bulk metallic glass was irradiated directly by KrF excimer laser pulses with wavelength 248 nm and duration 10 ns. Scanning electronic microscope photographs indicated that many ripples in micro-nano scale would be generated on the edge of the irradiated area under the action of the higher intensity laser pulse. Detailed observation demonstrated that the ripples exhibited fluidity and became closer and closer out from interior. Theoretical analysis revealed the formation mechanism of the ripples, including melting, subsequent propagation of capillary waves and final solidification.

36 MATERIALS SCIENCE↗

Plasma-based localized defect for switchable coupling applications

We report in this paper experimental measurements in order to validate the concept of switchable electromagnetic band gap filters based on plasma capillaries in the microwave regime. The plasma tube is embedded inside the structure to create a bistable (plasma on or off) punctual defect. We first investigate two kinds of discharge tubes: Ar-Hg and pure Ne, which we then use to experimentally achieve plasma-based reconfigurable applications, namely, a two-port coupler and a two-port demultiplexer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Observation and numerical analysis of plasma parameters in a capillary discharge-produced plasma channel waveguide

We observed the parameters of the discharge-produced plasma in cylindrical capillary. Plasma parameters of the waveguide were investigated by use of both a Normarski laser interferometer and a hydrogen plasma line spectrum. A space-averaged maximum temperature of 3.3 eV with electron densities of the order of 10{sup 17} cm{sup -3} was observed at a discharge time of 150 ns and a maximum discharge current of 200 A. One-dimensional dissipative magnetohydrodynamic (MHD) code was used to analyze the discharge dynamics in the gas-filled capillary discharge waveguide for high-intensity laser pulses. Simulations were performed for the conditions of the experiment. We compared the temporal behavior of the electron temperature and the radial electron density profiles, measured in the experiment with the results of the numerical simulations. They occurred to be in a good agreement. An ultrashort, intense laser pulse was guided by use of this plasma channel.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Guiding Of Slow Highly Charged Ions Through A Single Mesoscopic Glass Capillary

We present experimental studies of the transmission of slow 4.5 keV Ar{sup 9+} ions through a single cylindrical-shaped glass capillary of macroscopic dimension with large aspect ratio. We find stable transmission of a micrometer-scale beam with considerable intensity after a charge-up phase, in which a self-organized process leads to the formation of a guiding electric field. We show the time evolution of the transmitted intensity through the sample for various capillary tilt angles.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Inelastic Transmission Of Electrons Through A Single Macro-Glass Capillary And Secondary Electron Emission

The transmission of electrons with incident energies 300-1000 eV through single glass capillary samples of macroscopic dimensions has been investigated. The transmitted spectra for all energies indicate dominance of inelastic electrons as the tilt angle {psi} increases, with the ratio of inelastically to elastically transmitted intensity for tilt angles >2.5 deg. (the indirect region of transmission) reaching a constant value of about 2:1. When the secondary electron emission was analyzed, higher yield was observed with decreasing primary beam energy and with increasing sample tilt angle.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Muon density enhancement with a tapered capillary method

The focusing effect of a muon beam with a tapered capillary method has been investigated in a range from 4.2 MeV to 9.2 MeV (i.e. from 30 MeV/c to 45 MeV/c in momentum). We injected the muon beam into a pair of narrowing (tapered) plates and tubes made of glass, copper and gold-coated copper, and measured the energy distribution of the muon leaving from the outlet. The plates were tilted from an inlet of 40 mm to an outlet of 20 mm. The density enhancement was more prominent with the plates made of heavier elements. The largest beam density enhancement at 10 mm downstream of the outlet was 1.3 with the gold-coated copper narrowing plates. The enhancement was composed of muons scattered with a small angle. Their energy was slightly less than that of the initial beam. This effect did not depend on the surface roughness. The result strongly suggests a simple and effective way to increase the muon beam density for a small target.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗