Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM PROFILES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Computed Tomography of Transverse Phase Space

Two computed tomography techniques are explored to reconstruct beam transverse phase space using both simulated beam and multi-wire profile data in the Fermilab Muon Test Area ("MTA") beamline. Both Filtered Back-Projection ("FBP") and Simultaneous Algebraic Reconstruction Technique ("SART") algorithms [2] are considered and compared. Errors and artifacts are compared as a function of each algorithm’s free parameters, and it is shown through simulation and MTA beamline profiles that SART is advantageous for reconstructions with limited profile data.

43 PARTICLE ACCELERATORS↗

Estimated SAGE II ozone mixing ratios in early 1993 and comparisons with Stratospheric Photochemistry, Aerosols and Dynamic Expedition measurements

An empirical time-series model for estimating ozone mixing ratios based on Stratospheric Aerosols and Gas Experiment II (SAGE II) monthly mean ozone data for the period October 1984 through June 1991 has been developed. The modeling results for ozone mixing ratios in the 10- to 30- km region in early months of 1993 are presented. In situ ozone profiles obtained by a dual-beam UV-absorption ozone photometer during the Stratospheric Photochemistry, Aerosols and Dynamics Expedition (SPADE) campaign, May 1-14, 1993, are compared with the model results. With the exception of two profiles at altitudes below 16 km, ozone mixing ratios derived by the model and measured by the ozone photometer are in relatively good agreement within their individual uncertainties. The identified discrepancies in the two profiles are discussed.

Yue, G. K.↗

Performance and data analysis aspects of the new DIII-D monostatic profile reflectometer system

A new frequency-modulated profile reflectometer system, featuring a monostatic antenna geometry (using one microwave antenna for both launch and receive), has been installed on the DIII-D tokamak, providing a first experimental test of this measurement approach for profile reflectometry. Significant features of the new system are briefly described in this paper, including the new monostatic arrangement, use of overmoded, broadband transmission waveguide, and dual-polarization combination/demultiplexing. Updated data processing and analysis, and in-service performance aspects of the new monostatic profile reflectometer system are also presented. By using a raytracing code (GENRAY) to determine the approximate trajectory of the probe beam, the electron density (n{sub e}) profile can be successfully reconstructed with L-mode plasmas vertically shifted by more than 10 cm off the vessel midplane. Specifically, it is demonstrated that the new system has a capability to measure n{sub e} profiles with plasma vertical offsets of up to ±17 cm. Examples are also presented of accurate, high time and spatial resolution density profile measurements made over a wide range of DIII-D conditions, e.g., the measured temporal evolution of the density profile across a L-H transition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated generation of IMRT treatment plans for prostate cancer patients with metal hip prostheses: Comparison of different planning strategies

Purpose: To compare IMRT planning strategies for prostate cancer patients with metal hip prostheses.Methods: All plans were generated fully automatically (i.e., no human trial-and-error interactions) using iCycle, the authors' in-house developed algorithm for multicriterial selection of beam angles and optimization of fluence profiles, allowing objective comparison of planning strategies. For 18 prostate cancer patients (eight with bilateral hip prostheses, ten with a right-sided unilateral prosthesis), two planning strategies were evaluated: (i) full exclusion of beams containing beamlets that would deliver dose to the target after passing a prosthesis (IMRT{sub remove}) and (ii) exclusion of those beamlets only (IMRT{sub cut}). Plans with optimized coplanar and noncoplanar beam arrangements were generated. Differences in PTV coverage and sparing of organs at risk (OARs) were quantified. The impact of beam number on plan quality was evaluated.Results: Especially for patients with bilateral hip prostheses, IMRT{sub cut} significantly improved rectum and bladder sparing compared to IMRT{sub remove}. For 9-beam coplanar plans, rectum V{sub 60Gy} reduced by 17.5%{+-} 15.0% (maximum 37.4%, p= 0.036) and rectum D{sub mean} by 9.4%{+-} 7.8% (maximum 19.8%, p= 0.036). Further improvements in OAR sparing were achievable by using noncoplanar beam setups, reducing rectum V{sub 60Gy} by another 4.6%{+-} 4.9% (p= 0.012) for noncoplanar 9-beam IMRT{sub cut} plans. Large reductions in rectum dose delivery were also observed when increasing the number of beam directions in the plans. For bilateral implants, the rectum V{sub 60Gy} was 37.3%{+-} 12.1% for coplanar 7-beam plans and reduced on average by 13.5% (maximum 30.1%, p= 0.012) for 15 directions.Conclusions: iCycle was able to automatically generate high quality plans for prostate cancer patients with prostheses. Excluding only beamlets that passed through the prostheses (IMRT{sub cut} strategy) significantly improved OAR sparing. Noncoplanar beam arrangements and, to a larger extent, increasing the number of treatment beams further improved plan quality.

61 RADIATION PROTECTION AND DOSIMETRY↗

Longitudinal bunch shaping of picosecond high-charge MeV electron beams

With ever increasing demands for intensities in modern accelerators, the understanding of space-charge effects becomes crucial. Herein are presented measurements of optically shaped picosecond-long electron beams in a superconducting L-band linac over a wide range of charges, from 0.2 nC to 3.4 nC. At low charges, the shape of the electron beam is preserved, while at higher charge densities, modulations on the beam convert to energy modulations. Here, energy profile measurements using a spectrometer and time profile measurements using a streak camera reveal the dynamics of longitudinal space-charge on MeV-scale electron beams.

43 PARTICLE ACCELERATORS↗

Transport of ion beam in an annular magnetically expanding helicon double layer thruster

An ion beam generated by an annular double layer has been measured in a helicon thruster, which sustains a magnetised low-pressure (5.0 × 10{sup −4} Torr) argon plasma at a constant radio-frequency (13.56 MHz) power of 300 W. After the ion beam exits the annular structure, it merges into a solid centrally peaked structure in the diffusion chamber. As the annular ion beam moves towards the inner region in the diffusion chamber, a reversed-cone plasma wake (with a half opening angle of about 30°) is formed. This process is verified by measuring both the radial and axial distributions of the beam potential and beam current. The beam potential changes from a two-peak radial profile (maximum value ∼ 30 V, minimum value ∼ 22.5 V) to a flat (∼28 V) along the axial direction; similarly, the beam current changes from a two-peak to one-peak radial profile and the maximum value decreases by half. The inward cross-magnetic-field motion of the beam ions is caused by a divergent electric field in the source. Cross-field diffusion of electrons is also observed in the inner plume and is determined as being of non-ambipolar origin.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental validation of the TOPAS Monte Carlo system for passive scattering proton therapy

Purpose: TOPAS (TOol for PArticle Simulation) is a particle simulation code recently developed with the specific aim of making Monte Carlo simulations user-friendly for research and clinical physicists in the particle therapy community. The authors present a thorough and extensive experimental validation of Monte Carlo simulations performed with TOPAS in a variety of setups relevant for proton therapy applications. The set of validation measurements performed in this work represents an overall end-to-end testing strategy recommended for all clinical centers planning to rely on TOPAS for quality assurance or patient dose calculation and, more generally, for all the institutions using passive-scattering proton therapy systems. Methods: The authors systematically compared TOPAS simulations with measurements that are performed routinely within the quality assurance (QA) program in our institution as well as experiments specifically designed for this validation study. First, the authors compared TOPAS simulations with measurements of depth-dose curves for spread-out Bragg peak (SOBP) fields. Second, absolute dosimetry simulations were benchmarked against measured machine output factors (OFs). Third, the authors simulated and measured 2D dose profiles and analyzed the differences in terms of field flatness and symmetry and usable field size. Fourth, the authors designed a simple experiment using a half-beam shifter to assess the effects of multiple Coulomb scattering, beam divergence, and inverse square attenuation on lateral and longitudinal dose profiles measured and simulated in a water phantom. Fifth, TOPAS’ capabilities to simulate time dependent beam delivery was benchmarked against dose rate functions (i.e., dose per unit time vs time) measured at different depths inside an SOBP field. Sixth, simulations of the charge deposited by protons fully stopping in two different types of multilayer Faraday cups (MLFCs) were compared with measurements to benchmark the nuclear interaction models used in the simulations. Results: SOBPs’ range and modulation width were reproduced, on average, with an accuracy of +1, −2 and ±3 mm, respectively. OF simulations reproduced measured data within ±3%. Simulated 2D dose-profiles show field flatness and average field radius within ±3% of measured profiles. The field symmetry resulted, on average in ±3% agreement with commissioned profiles. TOPAS accuracy in reproducing measured dose profiles downstream the half beam shifter is better than 2%. Dose rate function simulation reproduced the measurements within ∼2% showing that the four-dimensional modeling of the passively modulation system was implement correctly and millimeter accuracy can be achieved in reproducing measured data. For MLFCs simulations, 2% agreement was found between TOPAS and both sets of experimental measurements. The overall results show that TOPAS simulations are within the clinical accepted tolerances for all QA measurements performed at our institution. Conclusions: Our Monte Carlo simulations reproduced accurately the experimental data acquired through all the measurements performed in this study. Thus, TOPAS can reliably be applied to quality assurance for proton therapy and also as an input for commissioning of commercial treatment planning systems. This work also provides the basis for routine clinical dose calculations in patients for all passive scattering proton therapy centers using TOPAS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Small-Scale Interstellar Structure Toward the Open Cluster CHI Persei-Fuse II

The purpose of this study was to measure the physical conditions of gas along sight lines toward 6 stars in the core Chi Persei open cluster. These sight lines traverse gas in both the Orion and Perseus spiral arms of the Galaxy, at distances of 500 and 2000 pc, respectively. The stars have angular separations ranging from 45 to 280 arcsec; 60 arcsec corresponds to linear distances of 0.15 and 0.6 pc in the two arms. Thus, abundance variations in these observations would constitute evidence for small-scale variations in the properties of the interstellar medium. Ground-based Na I observations at high resolution (approx. 15 km/sec) toward 172 stars (including the 6 in this study) in the double open cluster h and Chi Persei have revealed complex spatial variation. These variations are especially evident in the gas at velocities of -40 and -55 km/sec, corresponding to the Perseus spiral arm. 21 cm observations of HI emission using the Low Resolution DRAO Survey, with a 12-arcmin beam, also show variations. Averaging the Na I apparent optical depth profiles of neighboring sight lines in order to mimic such a beam size reduces the variation, as compared to the individual Na I measurements, but still show variations larger than seen in the 21 cm profiles. Na I is not the dominant ionization state of Na in the interstellar medium. Thus, it is possible that the variations seen really trace physical structures in the interstellar medium, or they may simply result from variations in the radiation field seen by the gas, or be due to some other environmental circumstance. To distinguish among these possibilities in the present study we obtained FUSE spectra toward the 6 targets in order to measure the molecular hydrogen absorption profiles along these sight lines. The higher J states of H2 are populated by the ambient W radiation field, and thus can provide insight into the environment affecting the gas. If both the high and low J states reveal absorption line profiles with variations similar to that observed in Na I, this would indicate that the variations are due to real structures in the interstellar medium. On the other hand, if the only the high J profiles mimicked the Na I profiles, then the variations may be attributable to environmental effects. We found that the H2 profiles showed considerable variation over the 6 sight lines, and that the profiles, despite having somewhat lower velocity resolution, resemble the Na I profiles. Thus, it appears that the gas really does exhibit variations in physical structures along these sight lines. Useful follow-up work would be to obtain higher signal-to-noise FUSE observations of H2, since the present data are of only moderate quality, and to obtain data on additional targets in this double cluster, in order to map out in more detail the extent and magnitude of the small-scale variations.

Sonneborn, George↗

LINAC Longitudinal Simulation and Measurement of Output Energy

The Fermilab Linac, a pivotal and historic accelerator at Fermilab, is crucial to the laboratory's operations, supplying a 400 MeV beam to various acceleration facilities. Due to daily variations in the Linac's output energy, precise monitoring and machine tuning are important to ensure the exiting energy meets the Booster's acceptance criteria. To address this, Beam Position Monitors (BPMs) are employed to assess and adjust the beam's energy, providing essential data on both the transverse position and longitudinal phase of the beam. We also aim to regulate the longitudinal phase profile to match our simulation predictions. By utilizing a Python-based simulation and beam data from three BPMs, we can determine the optimal phasing correction required for the final RF stage to achieve the desired energy. Currently, the calculations of longitudinal phase profile are based on simulations, so additional research is needed to verify if the predicted longitudinal phase distribution aligns with actual real-world data.

Safaryan, Milena↗

SU-E-T-624: Portal Dosimetry Commissioning of Multiple (6) Varian TrueBeam Linacs Equipped with PortalVision DMI MV Imager

Purpose: To show that a single model for Portal Domisetry (PD) can be established for beam-matched TrueBeam™ linacs that are equipped with the DMI imager (43×43cm effective area). Methods: Our department acquired 6 new TrueBeam™s, 4 “Slim” and 2 “Edge” models. The Slims were equipped with 6 and 10MV photons, and the Edges with 6MV. MLCs differed between the Slims and Edges (Millennium 120 vs HD-MLC respectively). PD model was created from data acquired using a single linac (Slim). This includes maximum field size profile, as well as output factors and acquired measured fluence using the DMI imager. All identical linacs were beam-matched, profiles were within 1% at maximum field size at a variety of depths. The profile correction file was generated from 40×40 profile acquired at 5cm depth, 95cm SSD, and was adjusted for deviation at the field edges and corners. The PD model and profile correction was applied to all six TrueBeam™s and imagers. A variety of jaw only and sliding window (SW) MLC test fields, as well as TG-119 and clinical SW and VMAT plans were run on each linac to validate the model. Results: For 6X and 10X, field by field comparison using 3mm/3% absolute gamma criteria passed 90% or better for all cases. This was also true for composite comparisons of TG-199 and clinical plans, matching our current department criteria. Conclusion: Using a single model per photon energy for PD for the TrueBeam™ equipped with a DMI imager can produce clinically acceptable results across multiple identical and matched linacs. It is also possible to use the same PD model despite different MLCs. This can save time during commissioning and software updates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of laser absorption in underdense plasmas using near-field imaging of the incident and transmitted beams

Measurements of laser absorption in high-temperature, underdense plasmas produced at the Omega Laser Facility are made using two near-field imaging detectors that diagnose the spatial profile and energy of the port P9 beam before and after it transmits through the plasma. The incident beam is sampled using a partial reflection from a full-aperture, (30 cm-diam) uncoated wedge pickoff located before the target chamber vacuum window and final focus lens assembly. A concave mirror reduces the reflected beam size, allowing it to be recorded directly using a charged-coupled device (CCD) camera. The P9 transmitted beam diagnostic (P9TBD) characterizes the transmitted light by terminating the expanded beam on a semi-transparent diffuser and imaging the illuminated surface using a lens and CCD camera. The P9TBD samples a numerical aperture twice as large as the input beam, allowing the energy of transmitted beams with moderate levels of beam spray to be measured accurately. Calibration shots with no plasma provide a path to infer absorption without absolute photometric calibration of either detector. Lastly, the cross-calibration between the two detectors was measured to remain stable at ±200 ppm, enabling measurements of total beam absorption below 1% with ±0.07% error.

47 OTHER INSTRUMENTATION↗

Identification characteristics of certain lunar relief forms on pictures obtained from spacecraft

This investigation was restricted to the determination of recognitional characteristics of a single type of relief form, dimple craters on the surface of maria. These craters were arbitrarily considered as closed, negative relief forms, circular in plan-view, and symmetric relative to the center. Two techniques were used to determine the shadow configuration in the craters: (1) experimental determination of the shadow edge by illuminating the models of different profile shapes with a parallel light beam; and (2) geometric construction of the shadow edge using a vertical section of the formation in the direction of the solar rays. A morphological map of the surface which includes the following factors can be compiled using the proposed identification technique: crater profile nature, crater diameter, ratio of diameter and depth, sharpness of the lip, and distribution density of the forms.

Kravtsova, V. I.↗

Fully Automated Profile-based Calibration Strategy for Airborne and Terrestrial Mobile LiDAR Systems with Spinning Multi-beam Laser Units

LiDAR-based mobile mapping systems (MMS) are rapidly gaining popularity for a multitude of applications due to their ability to provide complete and accurate 3D point clouds for any and every scene of interest. However, an accurate calibration technique for such systems is needed in order to unleash their full potential. In this paper, we propose a fully automated profile-based strategy for the calibration of LiDAR-based MMS. The proposed technique is validated by comparing its accuracy against the expected point positioning accuracy for the point cloud based on the used sensors’ specifications. The proposed strategy was seen to reduce the misalignment between different tracks from approximately 2 to 3 m before calibration down to less than 2 cm after calibration for airborne as well as terrestrial mobile LiDAR mapping systems. In other words, the proposed calibration strategy can converge to correct estimates of mounting parameters, even in cases where the initial estimates are significantly different from the true values. Furthermore, the results from the proposed strategy are also verified by comparing them to those from an existing manually-assisted feature-based calibration strategy. The major contribution of the proposed strategy is its ability to conduct the calibration of airborne and wheel-based mobile systems without any requirement for specially designed targets or features in the surrounding environment. The above claims are validated using experimental results conducted for three different MMS – two airborne and one terrestrial – with one or more LiDAR unit.

47 OTHER INSTRUMENTATION↗

Aligning the Thomson scattering and charge exchange recombination diagnostics using neutral beam emission at DIII-D

This work addresses discrepancies in the alignment of the H-mode pedestal profiles of the electron and ion properties in the DIII-D tokamak as measured by Thomson Scattering (TS) and Charge Exchange Recombination Spectroscopy (CER) diagnostics. While the alignment of these profiles is key for accurate studies of tokamak physics and plasma confinement, misalignments can occur due to inaccuracies, such as in magnetic equilibrium reconstructions required to map measurements in different poloidal and toroidal locations. Both FIDASIM, an established simulation package, and a simplified collisional radiative model are used to simulate neutral beam state densities and neutral beam emission. Simulated neutral beam emissions are calculated based on shifted TS profiles and compared to beam emission measurements from the Main Ion CER system to determine the best shift for aligning TS with CER. This analysis is performed on various DIII-D discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phase Space Dynamics of a Plasma Wakefield Dechirper for Energy Spread Reduction

Plasma-based accelerators have made impressive progress in recent years. However, the beam energy spread obtained in these accelerators is still at the ~1% level, nearly one order of magnitude larger than what is needed for challenging applications like coherent light sources or colliders. In plasma accelerators, the beam energy spread is mainly dominated by its energy chirp (longitudinally correlated energy spread). Furthermore, we demonstrate that when an initially chirped electron beam from a linac with a proper current profile is sent through a low-density plasma structure, the self-wake of the beam can significantly reduce its energy chirp and the overall energy spread. The resolution-limited energy spectrum measurements show at least a threefold reduction of the beam energy spread from 1.28% to 0.41% FWHM with a dechirping strength of ~1 (MV/m)/(mm pC). Refined time-resolved phase space measurements, combined with high-fidelity three-dimensional particle-in-cell simulations, further indicate the real energy spread after the dechirper is only about 0.13% (FWHM), a factor of 10 reduction of the initial energy spread.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Power balance on a multibeam laser

Inertial confinement fusion (ICF) cryogenic experiments on the 60-beam OMEGA laser have strict requirements for the laser energy delivered on target to be power balanced in order to maximize target-irradiation uniformity. For OMEGA, this quantity (power balance) is inferred from measurements of the time-integrated energy and time-resolved, spatially integrated temporal profile of each of the 60 beams at the output of the laser. The work presented here proposes a general definition of power balance as measured at the laser output and discusses the conditions that are fundamental to achieving laser power balance. Power balance necessitates equal gain across all stages of amplification, equal net losses across each amplifier stage, equal frequency conversion (from 1053 nm to 351 nm) of all 60 beams, and equal beam path lengths (beam timing). Typical OMEGA ICF laser pulse shapes consist of one or more short (100-ps) “pickets” followed by a shaped “drive” pulse of 1 to 2 ns. For these experiments, power balance is assessed for the pickets and the drive independently, with the ultimate goal of achieving root-mean-square (rms) imbalance across all 60 beams of less than 2% rms on both. Our work presents a comprehensive summary of laser shot campaigns conducted to significantly improve laser power balance from typical rms values of 4.7% and 5.2%, respectively, to the 3% level for both features along with a discussion of future work required to further reduce the rms power imbalance of the laser system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Controllable Planar Optical Focusing System

An optical device has a first metasurface disposed over a substrate. A high-contrast pattern of the first metasurface is operable for modifying, over a first phase profile, a phase front of an incident light beam. A second metasurface, is disposed over a plane parallel to the first metasurface with a second high-contrast pattern and operable for shaping, over a second phase profile, the modified phase front of the incident light beam into a converging spherical phase front. A spacer layer, in which the modified phase front of the incident light beam diffracts, is disposed in a controllably changeable separation between the first and second metasurfaces. Controllably changing the separation between the first and the second metasurfaces by a first distance correspondingly changes the position of the focus point of the converging spherical phase front by a second distance significantly greater than the first distance.

Arbabi, Amir↗

Controllable Planar Optical Focusing System

An optical device has a first metasurface. A high-contrast pattern of the first metasurface is operable for modifying, over a first phase profile, a phase front of an incident light beam. A second metasurface, is disposed over a plane parallel to the first metasurface with a second high-contrast pattern and operable for shaping, over a second phase profile, the modified phase front of the incident light beam into a converging spherical phase front. A spacer layer, in which the modified phase front of the incident light beam diffracts, is disposed in a controllably changeable separation between the first and second metasurfaces. Controllably changing the separation between the first and the second metasurfaces by a first distance correspondingly changes the position of the focus point of the converging spherical phase front by a second distance.

Arbabi, Amir↗