Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Beam Meassurements Using Visible Synchrotron Light at NSLSII Storage Ring

Visible Synchrotron Light Monitor (SLM) diagnostic beamline has been designed and constructed at NSLS2 storage ring, to characterize the electron beam profile at various machine conditions. Thanks for the excellent alignment, SLM beamline was able to see the first visible light when beam was circulating the ring for the first turn. The beamline has been commissioned for the past year. Besides a normal CCD camera to monitor the beam profile, streak camera and gated camera are used to measure the longitudinal and transverse profile to understand the beam dynamics. Measurement results from these cameras will be present in this paper. A time correlated single photon counting system (TCSPC) has been setup and measures the single bunch purity using visible light, preliminary TCSPC measurement result will be presented as well.

36 MATERIALS SCIENCE↗

Linear Induction Accelerator Cell Voltage Calibration Using Compact Electron Permanent Magnet Spectrometer

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using electron Linear Induction Accelerators (LIA’s). The strict requirements for flash radiography require a detailed understanding of the LIA’s performance, including precision measurements of the electron beam energy. Axis-1 of DARHT produces a 20 MeV, 2 kA, 80-ns-FWHM electron beam. Electronic measurement with cell-voltage monitors which consists of a 75 ohm load resistor and a current viewing resistor (CVR) that are coupled together and injector capacitive monitors (EVACSUM) are summed to give the total beam energy at the output of the accelerator. Calibration of these monitors was last done in 1999 and is needed. Using the Compact electron Permanent Magnet Spectrometer (CePMSpec), we have developed a technique for measuring and adjusting the calibration of the accelerator cell load resistor/CVR by using the total energy of the beam. Each pair of cells is driven by pulsed power Blumleins, and each Blumlein is charged by a Blumlein Charge Unit (BCU). There are 64 cells and 32 Blumleins and BCUs. This technique is applied to all 32 BCUs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Respiratory motion management in particle therapy

Clinical outcomes of charged particle therapy are very promising. Currently, several dedicated centers that use scanning beam technology are either close to clinical use or under construction. Since scanned beam treatments of targets that move with respiration most likely result in marked local over- and underdosage due to interplay of target motion and dynamic beam application, dedicated motion mitigation techniques have to be employed. To date, the motion mitigation techniques, rescanning, beam gating, and beam tracking, have been proposed and tested in experimental studies. Rescanning relies on repeated irradiations of the target with the number of particles reduced accordingly per scan to statistically average local misdosage. Specific developments to prohibit temporal correlation between beam scanning and target motion will be required to guarantee adequate averaging. For beam gating, residual target motion within gating windows has to be mitigated in order to avoid local misdosage. Possibly the most promising strategy is to increase the overlap of adjacent particle pencil beams laterally as well as longitudinally to effectively reduce the sensitivity against small residual target motion. The most conformal and potentially most precise motion mitigation technique is beam tracking. Individual particle pencil beams have to be adapted laterally as well as longitudinally according to the target motion. Within the next several years, it can be anticipated that rescanning as well as beam gating will be ready for clinical use. For rescanning, treatment planning margins that incorporate the full extent of target motion as well as motion induced density variations in the beam paths will result in reduced target conformity of the applied dose distributions. Due to the limited precision of motion monitoring devices, it seems likely that beam gating will be used initially to mitigate interplay effects only but not to considerably decrease treatment planning margins. Then, in the next step, beam gating, based on more accurate motion monitoring systems, provides the possibility to restore target conformity as well as steep dose gradients due to reduced treatment planning margins. Accurate motion monitoring systems will be required for beam tracking. Even though beam tracking has already been successfully tested experimentally, full clinical implementation requires direct feedback of the actual target position in quasireal time to the treatment control system and can be anticipated to be several more years ahead.

61 RADIATION PROTECTION AND DOSIMETRY↗

Scanned Carbon Pencil Beams for Tumor Therapy

At GSI a fully active beam application has been developed for tumor therapy with carbon ions. In this so-called rasterscan system the tumor volume is typically split into {approx}60 slices of iso-energies taken from a list of 252 energies ranging from {approx}90-430 MeV/u(range: 1.8-30.7 cm). The energies can be combined with variable beam diameters and intensities. For each iso-energy slice beam is requested from the synchrotron and delivered as a narrow pencil beam (beam's full width at half maximum 3-10 mm). For lateral target coverage this pencil beam is deflected to several hundreds of grid positions per iso-energy slice by orthogonal dipole magnets. At each grid position an optimized number of particles is deposited intensity-controlled, i.e. ionization chambers monitor the dose deposition and trigger deflection to the next grid position once the required dose level is achieved. This method allows intensity-modulated treatment fields necessary to deposit a uniform biological effective dose. Additionally, it allows for simultaneous optimization of multiple fields that allow better sparing of organs at risk partially or fully surrounded by the tumor. Scanned beam delivery facilitates target conformal and homogeneous dose delivery for stationary targets. For tumors located in the head and neck as well as tumors in the pelvic region very promising results were achieved in the carbon therapy pilot project started at GSI in 1993. A comparable project is conducted at Paul-Scherrer-Institut (PSI) in Switzerland with a scanned proton beam. One of the current research topics is the treatment of moving targets such as lung tumors. Scanned beam delivery requires but also offers possibilities to conformably irradiate moving target sites.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-BRE-14: Uncertainty Analysis for Dose Measurements Using OSLD NanoDots

Purpose: Optically stimulated luminescent dosimeters (OSLD) are an increasingly popular dosimeter for research and clinical applications. It is also used by the Radiological Physics Center for remote auditing of machine output. In this work we robustly calculated the reproducibility and uncertainty of the OSLD nanoDot. Methods: For the RPC dose calculation, raw readings are corrected for depletion, element sensitivity, fading, linearity, and energy. System calibration is determined for the experimental OSLD irradiated at different institutions by using OSLD irradiated by the RPC under reference conditions (i.e., standards): 1 Gy in a Cobalt beam. The intra-dot and inter-dot reproducibilities (coefficient of variation) were determined from the history of RPC readings of these standards. The standard deviation of the corrected OSLD signal was then calculated analytically using a recursive formalism that did not rely on the normality assumption of the underlying uncertainties, or on any type of mathematical approximation. This analytical uncertainty was compared to that empirically estimated from >45,000 RPC beam audits. Results: The intra-dot variability was found to be 0.59%, with only a small variation between readers. Inter-dot variability was found to be 0.85%. The uncertainty in each of the individual correction factors was empirically determined. When the raw counts from each OSLD were adjusted for the appropriate correction factors, the analytically determined coefficient of variation was 1.8% over a range of institutional irradiation conditions that are seen at the RPC. This is reasonably consistent with the empirical observations of the RPC, where the coefficient of variation of the measured beam outputs is 1.6% (photons) and 1.9% (electrons). Conclusion: OSLD nanoDots provide sufficiently good precision for a wide range of applications, including the RPC remote monitoring program for megavoltage beams. This work was supported by PHS grant CA10953 awarded by the NIH (DHHS)

60 APPLIED LIFE SCIENCES↗

Modeling of Global BEAM Structure for Evaluation of MMOD Impacts to Support Development of a Health Monitoring System

This report summarizes the initial modeling of the global response of the Bigelow Expandable Activity Module (BEAM) to micrometeorite and orbital debris(MMOD) impacts using a structural, nonlinear, transient dynamic, finite element code. These models complement the on-orbit deployment of the Distributed Impact Detection System (DIDS) to support structural health monitoring studies. Two global models were developed. The first focused exclusively on impacts on the soft-goods (fabric-envelop) portion of BEAM. The second incorporates the bulkhead to support understanding of bulkhead impacts. These models were exercised for random impact locations and responses monitored at the on-orbit sensor locations. The report concludes with areas for future study.

Lyle, Karen H.↗

Separating Images For Welding Control

Torch for automatic gas/tungsten-arc welding provides separate coaxial views of weld to two sensors. Each sensor functions in real time without interfering with other. One sensor provides information for vision-guided seam tracker; other feeds data to an optical weld-contour monitor for control penetration. Contains beam splitter at angle of 45 degree with electrode axis. Beam splitter reflects wavelengths below 550 nm to sensor for seam tracking. Transmits wavelengths above 550 nm to sensor for weld-contour monitoring. Filters added to split beam paths to limit further spectra transmitted to sensors. Beam splitter and filters easily changed to suit material and welding parameters.

Gordon, Stephen S.↗

Injection System Diagnostics

The linac beam diagnostics will be provided by Research Instruments (former ACCEL) as part of the linac package: • one removable Faraday cup after electron source, • five wall current monitors (WCM) located after electron source, bunching system and accelerating sections 1, 2, and 3, • six removable YAG:Ce screens including cameras, • five sets of buttons for beam position monitoring. BNL will provide receivers for the beam position monitors (BPMs).

36 MATERIALS SCIENCE↗

A Diamond Micro-strip Electron Detector for Compton Polarimetry

The Qweak experiment in Hall C at Jefferson Lab aims to measure the weak charge of the proton with a precision of 4.1{\%} by measuring the parity violating asymmetry in polarized electron-proton elastic scattering. Beam polarimetry is the largest experimental contribution to the error budget. A new Compton polarimeter was installed for a non-invasive and continuous monitoring of the electron beam polarization with a goal of 1{\%} systematic and 1{\%} per hour statistical precision. The Compton-scattered electrons are detected in four planes of diamond micro-strip detectors. These detectors are read out using custom built electronic modules that include a pre-amplifier, a pulse shaping amplifier and a discriminator for each detector micro-strip. We use Field Programmable Gate Array based general purpose logic modules for event selection and histogramming. The polarimeter was commissioned during the first run period of the Qweak experiment. We will show the preliminary results from the electron detector obtained during the first run period of Qweak experiment.

Narayan, Amrendra↗

Storage Rings

Storage rings are circular machines that store particle beams at a constant energy. Beams are stored in rings without acceleration for a number of reasons (Tab. 1). Storage rings are used in high-energy, nuclear, atomic, and molecular physics, as well as for experiments in chemistry, material and life sciences. Parameters for storage rings such as particle species, energy, beam intensity, beam size, and store time vary widely depending on the application. The beam must be injected into a storage ring but may not be extracted (Fig. 1). Accelerator rings such as synchrotrons are used as storage rings before and after acceleration. Particles stored in rings include electrons and positrons; muons; protons and anti-protons; neutrons; light and heavy, positive and negative, atomic ions of various charge states; molecular and cluster ions, and neutral polar molecules. Spin polarized beams of electrons, positrons, and protons were stored. The kinetic energy of the stored particles ranges from 10{sup -6} eV to 3.5 x 10{sup 12} eV (LHC, 7 x 10{sup 12} eV planned), the number of stored particles from one (ESR) to 1015 (ISR). To store beam in rings requires bending (dipoles) and transverse focusing (quadrupoles). Higher order multipoles are used to correct chromatic aberrations, to suppress instabilities, and to compensate for nonlinear field errors of dipoles and quadrupoles. Magnetic multipole functions can be combined in magnets. Beams are stored bunched with radio frequency systems, and unbunched. The magnetic lattice and radio frequency system are designed to ensure the stability of transverse and longitudinal motion. New technologies allow for better storage rings. With strong focusing the beam pipe dimensions became much smaller than previously possible. For a given circumference superconducting magnets make higher energies possible, and superconducting radio frequency systems allow for efficient replenishment of synchrotron radiation losses of large current electron or positron beams. Storage rings have instrumentation to monitor the electrical and mechanical systems, and the beam quality. Computers are used to control the operation. Large storage rings have millions of control points from all systems. The time dependent beam intensity I(t) can often be approximated by an exponential function I(t) = I(0) exp(-t/{tau}) (1) where the decay time {tau} and, correspondingly, the store time ranges from a few turns to 10 days (ISR). {tau} can be dominated by a variety of effects including lattice nonlinearities, beam-beam, space charge, intrabeam and Touschek scattering, interaction with the residual gas or target, or the lifetime of the stored particle. In this case, the beam lifetime measurement itself can be the purpose of a storage ring experiment. The main consideration in the design of a storage ring is the preservation of the beam quality over the store length. The beam size and momentum spread can be reduced through cooling, often leading to an increase in the store time. For long store times vacuum considerations are important since the interaction rate of the stored particles with the residual gas molecules is proportional to the pressure, and an ultra-high vacuum system may be needed. Distributed pumping with warm activated NEG surfaces or cold surfaces in machines with superconducting magnets are ways to provide large pumping speeds and achieve low pressures even under conditions with dynamic gas loads. The largest application of storage rings today are synchrotron light sources, of which about 50 exist world wide. In experiments where the beam collides with an internal target or another beam, a storage ring allows to re-use the accelerated beam many times if the interaction with the target is sufficiently small. In hadron collider and ion storage rings store times of many hours or even days are realized, corresponding to up to 1011 turns and thereby target passages. Ref. [3] is the first proposal for a collider storage ring. A number of storage rings exist where the beam itself or its decay products are the object of study.

43 PARTICLE ACCELERATORS↗

SU-E-T-340: Dosimetry of a Small Field Electron Beam for Innovative Radiotherapy of Small Surface Or Internal Tumors

Purpose: An innovative small high intensity electron beams with energies from 6 to 12 MeV is being developed at Argonne National Laboratory to deliver an absorbed dose via a catheter to small malignant and nonmalignant lesions. This study reports on the initial dosimetric characteristics of this electron beam. These include output calibration, percent depth dose, beam profiles and leakage through the catheter. Methods: To simulate the narrow electron beam, the Argonne Wakefield Accelerator is used to produce high energy electron beams. The electron beam from the accelerator is monitored by measuring the current through a transmission coil while the beam shape is observed with a fluorescent screen. The dosimetry properties of the electron beam transmitting through bone and tissue-like materials are measured with nanodot optically stimulated luminescent dosimeters and EDR radiographic film. The 6 MV photon beam from a Varian True beam linac is used to calibrate both the OSLDs and the film. Results: The beam characteristics of the 12 MeV beam were measured. The properties of the small diameter, 5 mm, beam differs from that of broad clinical electron beams from radiotherapy linacs. Due to the lack of scatter from the narrow beam, the maximum dose is at the surface and the depth of the 50% depth dose is 35 mm compared to 51 mm for a clinical 12 MeV. The widths of the 90% isodose measured at the surface and depths of 2, 6, 12, and 16 mm varied from 6.6 to 8.8 mm while the widths of the FWHM isodose varied from 7.8 to 25.5 mm. Conclusion: Initial beam measurements show favorable dosimetric properties for its use in treating either small surface or internal lesions, particularly to deliver radiation at the time of surgery to maximize the dose to the lesion and spare normal tissue.

60 APPLIED LIFE SCIENCES↗

Method for Measuring Collimator-Pointing Sensitivity to Temperature Changes

For a variety of applications, it is important to measure the sensitivity of the pointing of a beam emerging from a collimator, as a function of temperature changes. A straightforward method for carrying out this measurement is based on using interferometry for monitoring the changes in beam pointing, which presents its own problems. The added temperature dependence and complexity issues relating to using an interferometer are addressed by not using an interferometer in the first place. Instead, the collimator is made part of an arrangement that uses a minimum number of low-cost, off-the-shelf materials and by using a quad diode to measure changes in beam pointing. In order to minimize the influence of the test arrangement on the outcome of the measurement, several steps are taken. The collimator assembly is placed on top of a vertical, 1-m-long, fused silica tube. The quad diode is bonded to a fused silica bar, which, in turn, is bonded to the lower end of the fused silica tube. The lower end of the tube rests on a self-aligning support piece, while the upper end of the tube is kept against two rounded setscrew tips, using a soft rubber string. This ensures that very little stress is applied to the tube as the support structure changes dimensions due to thermal expansion. Light is delivered to the collimator through a bare fiber in order to minimize variable bending torque caused by a randomly relaxing, rigid fiber jacket. In order to separate the effect of temperature on the collimator assembly from the effect temperature has on the rest of the setup, multiple measurements are taken with the collimator assembly rotated from measurement to measurement. Laboratory testing, with 1-m spacing between the collimator and the quad diode, has shown that the sensitivity of the arrangement is better than 100 nm rms, over time spans of at least one hour, if the beam path is protected from atmospheric turbulence by a tube. The equivalent sensitivity to detecting changes in pointing angle is 100 nanoradians.

Abramovici, Alex↗

Exploiting the PRISM Feature and Purity Monitors of the SBND Neutrino Detector

The Short-Baseline Neutrino (SBN) program at Fermilab will pursue neutrino properties searches, exploiting three Liquid Argon Time Projection Chamber (LArTPC) experiments to investigate neutrino oscillations with neutrinos from the Booster Neutrino Beam (BNB). SBND will be the near detector in the program, measuring the un-oscillated flux. It is anticipated to begin operating in 2023. Thanks to its peculiar proximity to the neutrino source of about 110 meters, SBND will collect extremely high statistics data of the flux in the GeV energy range, providing unprecedented precision measurements. SBND particular setting also allows to take measurements at different distances from BNB’s center maintaining statistics high enough at each range. LArTPC and the cold electronics technologies, as well as the argon-neutrino interaction studies, will play a key role in future neutrino physics. In this prospect, this work was focused on two SBND features: SBND PRISM tool, with the aim of investigating neutrino flux at different distances from the beam axis, and Purity Monitors, which provide a clever measurement of argon purity in the detector, whose value is fundamental in neutrino-argon interaction.

43 PARTICLE ACCELERATORS↗

P78-2 satellite and payload responses to electron beam operations on March 30, 1979

The operating modes of the SC4-1 payload, the resultant charging of the spacecraft frame and sample materials on the spacecraft exterior and recorded transient pulses are reported. Arcing was detected by pulse monitors in several electron beam modes of operation. The ejection of a beam of 6 mA of 3 keV electrons caused three distinct payload failures and created a transient problem in the telemetry system. The exact time, nature, and cause of these failures was determined and component failure and why they failed was identified. Analytical and modeling techniques are used to examine possible spacecraft and payload responses to the electron beam ejection which might have contributed to the arcing and payload failures.

Cohen, H. A.↗

Accuracy evaluation of the optical surface monitoring system on EDGE linear accelerator in a phantom study

Frameless stereotactic radiosurgery (SRS) requires dedicated systems to monitor the patient position during the treatment to avoid target underdosage due to involuntary shift. The optical surface monitoring system (OSMS) is here evaluated in a phantom-based study. The new EDGE linear accelerator from Varian (Varian, Palo Alto, CA) integrates, for cranial lesions, the common cone beam computed tomography (CBCT) and kV-MV portal images to the optical surface monitoring system (OSMS), a device able to detect real-time patient's face movements in all 6 couch axes (vertical, longitudinal, lateral, rotation along the vertical axis, pitch, and roll). We have evaluated the OSMS imaging capability in checking the phantoms' position and monitoring its motion. With this aim, a home-made cranial phantom was developed to evaluate the OSMS accuracy in 4 different experiments: (1) comparison with CBCT in isocenter location, (2) capability to recognize predefined shifts up to 2° or 3 cm, (3) evaluation at different couch angles, (4) ability to properly reconstruct the surface when the linac gantry visually block one of the cameras. The OSMS system showed, with a phantom, to be accurate for positioning in respect to the CBCT imaging system with differences of 0.6 ± 0.3 mm for linear vector displacement, with a maximum rotational inaccuracy of 0.3°. OSMS presented an accuracy of 0.3 mm for displacement up to 1 cm and 1°, and 0.5 mm for larger displacements. Different couch angles (45° and 90°) induced a mean vector uncertainty < 0.4 mm. Coverage of 1 camera produced an uncertainty < 0.5 mm. Translations and rotations of a phantom can be accurately detect with the optical surface detector system.

61 RADIATION PROTECTION AND DOSIMETRY↗

Arc Testing of a Mockup Cable in a Simulated Space Radiation Environment

A mockup cable was irradiated with electrons of 25-100 keV energy in a vacuum chamber. The m'ockup cable consisted of insulated wires on a kapton substrate, overlaid with a metallized teonex shield. Voltages induced on the wires and shield by the electron beam during irradiation were monitored, and voltage changes were used, along with video, to detect arcs due to the charge built-up in the cable. The cable was also cooled with liquid nitrogen to very low temperatures, to simulate cables kept in the dark for long periods of time. Arcing was common at fluences typical of long space missions. Occasionally an arc would occur some time after the electron beam was turned off. The conductivity of the wires and shield was monitored as a function of temperature, and behaved as expected, with lower conductivities at lower temperatures. Arcs from the wires and shield to ground and from the wires to the shield were measured. Sympathetic arcs were also seen, wherein an arc from the shield to ground or from the wires to ground was followed in a short period of time by another arc of a different type. Implications of these results for real cables on long space missions will be discussed, and recommendations given for arc mitigation.

Ferguson, D. C.↗

An overview of the new test stand for H{sup −} ion sources at FNAL

A new test stand at Fermi National Accelerator Laboratory (FNAL) is being constructed to carry out experiments to develop and upgrade the present magnetron-type sources of H{sup −} ions of up to 80 mA at 35 keV in the context of the Proton Improvement Plan. The aim of this plan is to provide high-power proton beams for the experiments at FNAL. The technical details of the construction and layout of this test stand are presented, along with a prospective set of diagnostics to monitor the sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗