Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BACKGROUND NOISE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Lossy compression of weak lensing data

Future orbiting observatories will survey large areas of sky in order to constrain the physics of dark matter and dark energy using weak gravitational lensing and other methods. Lossy compression of the resultant data will improve the cost and feasibility of transmitting the images through the space communication network. We evaluate the consequences of the lossy compression algorithm of Bernstein et al. (2010) for the high-precision measurement of weak-lensing galaxy ellipticities. This square-root algorithm compresses each pixel independently, and the information discarded is by construction less than the Poisson error from photon shot noise. For simulated space-based images (without cosmic rays) digitized to the typical 16 bits per pixel, application of the lossy compression followed by image-wise lossless compression yields images with only 2.4 bits per pixel, a factor of 6.7 compression. We demonstrate that this compression introduces no bias in the sky background. The compression introduces a small amount of additional digitization noise to the images, and we demonstrate a corresponding small increase in ellipticity measurement noise. The ellipticity measurement method is biased by the addition of noise, so the additional digitization noise is expected to induce a multiplicative bias on the galaxies measured ellipticities. After correcting for this known noise-induced bias, we find a residual multiplicative ellipticity bias of m {approx} -4 x 10 -4 . This bias is small when compared to the many other issues that precision weak lensing surveys must confront, and furthermore we expect it to be reduced further with better calibration of ellipticity measurement methods.

79 ASTRONOMY AND ASTROPHYSICS↗

Detection of Isotopes in Urban Source Search Gamma Spectra Using Hopfield Neural Network

Source search campaigns involve the measurement of consecutive background gamma-ray spectra obtained with a mobile detector-spectrometer, such as tellurium-doped sodium iodide NaI(Tl) scintillator detector-spectrometer. Counts are measured with NaI(Tl) detector in short acquisition intervals, such as one second. Detection of isotopes in search data is challenging because of the low signal-to-noise ratio (S/N) of the spectral lines and highly varying background due to naturally occurring radioactive material (NORM). In this work, we investigate the performance of the detection of orphan Cs-137, Am-241, and I-131 isotopes in a gamma ray data set obtained in a search survey. Isotopic detection is performed with a Hopfield Neural Network (HNN), which implements an auto-associative memory by matching incoming measurements to the closest one of its memory-stored signature patterns. HNN is trained on examples of spectra of calibrated isotopic sources with well-resolved spectral lines. During testing, HNN processes spectra with partially complete or distorted isotopic lines. The performance of the HNN detection algorithm is benchmarked with Precision, Recall, and F1 scores. Test results demonstrate the potential of HNN to detect the isotope of interest with high accuracy (F1 > 90%) for all isotopes in this study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photon bunching and the photon-noise-limited performance of infrared detectors

The photon-noise-limited performance of a radiation detector exposed to a thermal background of temperature T is analyzed by calculating the resulting specific detectivity. Both ideal photon detectors of arbitrary quantum efficiency eta and ideal thermal detectors of arbitrary emissivity eta are considered; and the effects of both shot noise and excess noise are taken into account. The relative contributions of these two sources depend on the quantum efficiency or emissivity of the system. For frequencies nu such that hnu/kT is much less than eta, excess noise can make an appreciable contribution to the total system noise. For the case of the detection of the narrow-band radiation, the specific detectivity is independent of eta in the limit hnu/kT is much less than eta.

Boyd, R. W.↗

Advanced ACTPol TES Device Parameters and Noise Performance in Fielded Arrays

The Advanced ACTPol (AdvACT) upgrade to the Atacama Cosmology Telescope (ACT) features arrays of aluminum manganese transition-edge sensors (TESes) optimized for ground-based observations of the cosmic microwave background (CMB). Array testing shows highly responsive detectors with anticipated in-band noise performance under optical loading. We report on TES parameters measured with impedance data taken on a subset of TESes. We then compare modeled noise spectral densities to measurements. We find excess noise at frequencies around 100 Hz, nearly outside of the signal band of CMB measurements. In addition, we describe full-array noise measurements in the laboratory and in the field for two new AdvACT mid-frequency arrays, sensitive at bands centered on 90 and 150 GHz, and data for the high-frequency array (150/230 GHz) as deployed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Noise-resolution tradeoffs in x-ray CT imaging: A comparison of penalized alternating minimization and filtered backprojection algorithms

Purpose: In comparison with conventional filtered backprojection (FBP) algorithms for x-ray computed tomography (CT) image reconstruction, statistical algorithms directly incorporate the random nature of the data and do not assume CT data are linear, noiseless functions of the attenuation line integral. Thus, it has been hypothesized that statistical image reconstruction may support a more favorable tradeoff than FBP between image noise and spatial resolution in dose-limited applications. The purpose of this study is to evaluate the noise-resolution tradeoff for the alternating minimization (AM) algorithm regularized using a nonquadratic penalty function. Methods: Idealized monoenergetic CT projection data with Poisson noise were simulated for two phantoms with inserts of varying contrast (7%-238%) and distance from the field-of-view (FOV) center (2-6.5 cm). Images were reconstructed for the simulated projection data by the FBP algorithm and two penalty function parameter values of the penalized AM algorithm. Each algorithm was run with a range of smoothing strengths to allow quantification of the noise-resolution tradeoff curve. Image noise is quantified as the standard deviation in the water background around each contrast insert. Modulation transfer functions (MTFs) were calculated from six-parameter model fits to oversampled edge-spread functions defined by the circular contrast-insert edges as a metric of local resolution. The integral of the MTF up to 0.5 lp/mm was adopted as a single-parameter measure of local spatial resolution. Results: The penalized AM algorithm noise-resolution tradeoff curve was always more favorable than that of the FBP algorithm. While resolution and noise are found to vary as a function of distance from the FOV center differently for the two algorithms, the ratio of noises when matching the resolution metric is relatively uniform over the image. The ratio of AM-to-FBP image variances, a predictor of dose-reduction potential, was strongly dependent on the shape of the AM's nonquadratic penalty function and was also strongly influenced by the contrast of the insert for which resolution is quantified. Dose-reduction potential, reported here as the fraction (%) of FBP dose necessary for AM to reconstruct an image with comparable noise and resolution, for one penalty parameter value of the AM algorithm was found to vary from 70% to 50% for low-contrast and high-contrast structures, respectively, and from 70% to 10% for the second AM penalty parameter value. However, the second penalty, AM-700, was found to suffer from poor low-contrast resolution when matching the high-contrast resolution metric with FBP. Conclusions: The results of this simulation study imply that penalized AM has the potential to reconstruct images with similar noise and resolution using a fraction (10%-70%) of the FBP dose. However, this dose-reduction potential depends strongly on the AM penalty parameter and the contrast magnitude of the structures of interest. In addition, the authors' results imply that the advantage of AM can be maximized by optimizing the nonquadratic penalty function to the specific imaging task of interest. Future work will extend the methods used here to quantify noise and resolution in images reconstructed from real CT data.

60 APPLIED LIFE SCIENCES↗

Cosmic backgrounds from primeval dust

A general formalism is developed for describing the spectrum and the anisotropy of radiation from primeval dust as a nearly isotropic cosmic background with fluctuations. The theory incorporates spatial and temporal variations in the density of both luminosity and dust and is sufficiently robust to treat emission by point sources, as well as smoother emission, in high and low optical depth situations. The fluctuations are calculated using linear perturbation theory for arbitrary dust and luminosity clumping, and are calculated nonperturbatively for compact IR sources using shot-noise models. For many realistic models, a large accompanying NIR background is predicted. It is shown that, while spectal information alone provides only coarse information about the dust abundance and type, the redshift, and the other parameters, it may provide a powerful probe of pregalactic history when used in combination with the anisotropy signal.

Bond, J. R.↗

Towards Geospatial Knowledge Graph Infused Neuro-Symbolic AI for Remote Sensing Scene Understanding

Deep learning has proven its effectiveness in numerous tasks for remote sensing scene understanding. However there is an increasing interest to explore fusion of domain-specific background information to the deep neural network to further improve its performance. Remote sensing researchers are also working towards developing models that generalize and adapt to multiple applications. Generalization challenges coupled with the scarcity of large corpora of high-quality noise-free labelled data, have together fueled an interest for leveraging background information. Knowledge graphs serve as excellent choice to represent domain-specific information in a structured, standardized and extensible manner. Integrating symbolic knowledge representations in the form of Knowledge Graph Embedding (KGE) to perform neuro-symbolic reasoning is an emerging research direction promising significant impacts. This vision paper seeks to position ideas and provoke early thoughts toward advancing neuro-symbolic artificial intelligence in the context of geospatial challenges. Specifically, it conceptualizes and elaborates on an architecture for infusing geospatial knowledge from knowledge graph in a deep neural network pipeline. As guiding case studies - land-use land-cover classification, object detection and instance segmentation can benefit from infusing spatio-contextual information with remote sensing imagery. The discussion further reflects on and articulates the challenges and explainable AI opportunities anticipated when scaling and maintaining large-scale geospatial knowledge graphs.

Potnis, Abhishek↗

Incorporating multislice imaging into x-ray CT polymer gel dosimetry

Purpose: To evaluate multislice computed tomography (CT) scanning for fast and reliable readout of radiation therapy (RT) dose distributions using CT polymer gel dosimetry (PGD) and to establish a baseline assessment of image noise and uniformity in an unirradiated gel dosimeter. Methods: A 16-slice CT scanner was used to acquire images through a 1 L cylinder filled with water. Additional images were collected using a single slice machine. The variability in CT number (N{sub CT}) associated with the anode heel effect was evaluated and used to define a new slice-by-slice background subtraction artifact removal technique for CT PGD. Image quality was assessed for the multislice system by evaluating image noise and uniformity. The agreement in N{sub CT} for slices acquired simultaneously using the multislice detector array was also examined. Further study was performed to assess the effects of increasing x-ray tube load on the constancy of measured N{sub CT} and overall scan time. In all cases, results were compared to the single slice machine. Finally, images were collected throughout the volume of an unirradiated gel dosimeter to quantify image noise and uniformity before radiation is delivered. Results: Slice-by-slice background subtraction effectively removes the variability in N{sub CT} observed across images acquired simultaneously using the multislice scanner and is the recommended background subtraction method when using a multislice CT system. Image noise was higher for the multislice system compared to the single slice scanner, but overall image quality was comparable between the two systems. Further study showed N{sub CT} was consistent across image slices acquired simultaneously using the multislice detector array for each detector configuration of the slice thicknesses examined. In addition, the multislice system was found to eliminate variations in N{sub CT} due to increasing x-ray tube load and reduce scanning time by a factor of 4 when compared to imaging a large volume using a single slice scanner. Images acquired through an unirradiated, active gel revealed N{sub CT} varies between the top and bottom of the 1 L cylinder as well as across the diameter of the cylinder by up to 7 HU. Conclusions: Multislice CT imaging has been evaluated for CT PGD and found to be the superior technique compared to single slice imaging in terms of the time required to complete a scan and the tube load characteristics associated with each scanning method. The implementation of multislice scanning is straightforward and expected to facilitate routine gel dosimetry measurements for complex dose distributions in modern RT centers.

60 APPLIED LIFE SCIENCES↗

Characteristics of magnetospheric radio noise spectra

Magnetospheric radio noise spectra (30 kHz to 10 MHz) taken by IMP-6 and RAE-2 exhibit time varying characteristics which are related to spacecraft position and magnetospheric processes. In the midfrequency range (100-1000 kHz) intense noise peaks rise a factor of 100 or more above background; 80% of the peak frequencies are within the band 125 kHz to 600 kHz, and the peak occurs most often (18% of the time) at 280 kHz. Bandwidths of the peaks range from about 100 kHz to more than 500 kHz; most often the lower cutoff is at about 100 kHz and the upper at 380 kHz for a total bandwidth of 280 kHz. This intense mid-frequency noise was detected at radial distances from 1.3 Re to 60 Re on all sides of the earth (i.e., all local times) during magnetically quiet as well as disturbed periods. Maximum occurrence of the mid-frequency noise is in the evening to midnight hours where splash-type energetic particle precipitation takes place.

Herman, J. R.↗

Primordial non-Gaussianity estimator: The inhomogeneous noise effect

Since the inhomogeneous instrument noise can produce extra non-Gaussianity in the cosmic microwave background (CMB) anisotropy, its effect should be carefully subtracted in the primordial non-Gaussianity estimation. We calculate the probability distribution function of the CMB anisotropy for a local type of non-Gaussianity, from which the optimal estimator in the general case (inhomogeneous noise and cut sky) is obtained. The new estimator obtained here is different from the popular one, since the inhomogeneous noise and cut sky effects are completely accounted for. The CMB anisotropy in the new estimator is noise weighted. The noise weight is different from that used by the WMAP Collaboration in their 5-year data analysis. Although it is still difficult to calculate the new estimator rigorously, for the case of the slightly inhomogeneous noise, there exists a series expansion method to compute the new estimator. Each order in the series is suppressed by two factors, (({sigma}{sup 2}/{sigma}{sub i}{sup 2})-1) and (C{sub l}/C{sub l}{sup tot}), which make the method feasible. Through the Edgeworth expansion we can generalize our discussion to other types of non-Gaussianity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Atomic gravitational wave interferometric sensor

We propose two distinct atom interferometer gravitational wave detectors, one terrestrial and another satellite based, utilizing the core technology of the Stanford 10 m atom interferometer presently under construction. Each configuration compares two widely separated atom interferometers run using common lasers. The signal scales with the distance between the interferometers, which can be large since only the light travels over this distance, not the atoms. The terrestrial experiment with two {approx}10 m atom interferometers separated by a {approx}1 km baseline can operate with strain sensitivity {approx}(10{sup -19}/{radical}(Hz)) in the 1 Hz-10 Hz band, inaccessible to LIGO, and can detect gravitational waves from solar mass binaries out to megaparsec distances. The satellite experiment with two atom interferometers separated by a {approx}1000 km baseline can probe the same frequency spectrum as LISA with comparable strain sensitivity {approx}(10{sup -20}/{radical}(Hz)). The use of ballistic atoms (instead of mirrors) as inertial test masses improves systematics coming from vibrations and acceleration noise, and significantly reduces spacecraft control requirements. We analyze the backgrounds in this configuration and discuss methods for controlling them to the required levels.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Wind turbine audibility and noise annoyance in a national U.S. survey: individual perception and influencing factors

With results from a nationwide survey sponsored by the U.S. Department of Energy, factors that affect outdoor audibility and noise annoyance of wind turbines were evaluated. Wind turbine and summer daytime median background sound levels were estimated for 1,043 respondents. Wind turbine sound level was the most robust predictor of audibility yet only a weak, albeit significant, predictor of noise annoyance. For each 1 dB increase in wind turbine sound level (L1h-max), the odds of hearing a wind turbine on one’s property increased by 31% (OR: 1.31; 95%CI: 1.25–1.38) and the odds of moving to the next level of annoyance increased by 9% (OR: 1.09; 95%CI: 1.02–1.16). While audibility was overwhelmingly dependent on turbine sound level, noise annoyance was best explained by visual disapproval (OR: 11.0; 95%CI: 4.8–25.4). The final models correctly predict audibility and annoyance level for 80% and 62% of individuals, respectively. The results demonstrate that among community members not receiving personal benefits from wind projects, the Community Tolerance Level of wind turbine noise for the U.S. aligns with the international average, further supporting observations that communities are less tolerant of wind turbine noise than other common environmental noise sources at equivalent A-weighted sound levels.

17 WIND ENERGY↗

Understanding and quantifying the systematic effects of clutter within a radiation detection scene

Because of low signal-to-noise ratios, the main difficultly in real-world detection scenarios is distinguishing between benign sources and potentially-threatening radioactive materials. The variability in observed signal during a radiation detection search operation can be contributed to the stochastic nature of the underlying physics and the systematic errors inherent to the detection systems employed. This variability is compounded for dynamic detection scenarios, where objects, referred to as clutter, traverse through the primary detection scene, introducing potential suppressions in the observed signal due to the attenuation of background radiation. This study examines the impact that clutter, namely automobiles such as small utility vehicles, sedans, and trucks, produces on the observed signal in a 2 in. × 4 in. × 16 in. NaI(Tl) detector. The clutter is identified and tracked in the detection scene using a time-synced video camera and a 2-D light distance and ranging contextual sensors. Two experiments were performed on the Oak Ridge National Laboratory reservation: one using a distributed source within the scene to understand the systematics of detecting and analyzing the clutter, and the second experiment mimicking an urban environment with large buildings positioned on either side of a roadway. The experiments exhibited unique results in the amount of signal suppression and variability of the cluttered signal, both demonstrating an observable suppression from the clutter-free background. These results reveal a new potential category of signal noise intrinsic to real-world detection scenarios that should be considered when establishing detection thresholds based on expected values.

Stewart, Ian R.↗

Informing solar blind radioluminescence imaging through a calibrated spectrum

While direct radiation detection methods offer great insight into the origin of ionizing particles and photons, their use to locate contaminated areas or concealed radioactive sources can lead to undue exposure of personnel and equipment to ionizing radiation or the potential for contamination. These same sources induce ultraviolet (UV) optical photon fluorescence in air – a process referred to as radioluminescence – that may be imaged from low dose regions over larger attenuation lengths than ionizing radiation. However, most optical detection methods are limited to low lighting conditions to image the more abundant ultraviolet-A (UV-A) photons. To extend this capability to room light or daytime conditions, the solar blind region (Ultraviolet-C (UV-C), <280 nm) can be tapped. Though the emission yield of UV-C photons is roughly two orders of magnitude lower than that in the UV-A regime, the UV-C offers dramatic improvements in signal-to-noise ratios under bright lighting conditions due to decreased background interferences. The yield of specific UV-C lines, if present in the literature at all, varies widely, which has a large impact in modeling and analyzing standoff UV-C measurement scenarios. Thus, we have captured improved radioluminescence spectra over 250–400 nm and identified observed emission peaks in ambient air. Many of the UV-C photons produced by ionizing radiation excitation result from high-energy, molecular nitrogen Gaydon-Herman transitions which have had limited study to date for this application. Relating these findings to published UV-A yields, we estimate emissions between 0.15–0.19 photons/MeV over 250–280 nm. Additionally, we also use a commercial corona-discharge imaging camera to demonstrate outdoor UV-C radiation mapping of alpha and gamma emitters from 50 and 75 m standoffs, respectively. The imaged “counts” are compared to optically modelled values and show the same trend over distance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electro-optic sampling for time resolving relativistic ultrafast electron diffraction

The Pegasus laboratory at UCLA features a state-of-the-art electron photoinjector capable of producing ultrashort (<100 fs) high-brightness electron bunches at energies of 3.75 MeV. These beams recently have been used to produce static diffraction patterns from scattering off thin metal foils, and it is foreseen to take advantage of the ultrashort nature of these bunches in future pump-probe time-resolved diffraction studies. In this paper, single shot 2-d electro-optic sampling is presented as a potential technique for time of arrival stamping of electron bunches used for diffraction. Effects of relatively low bunch charge (a few 10's of pC) and modestly relativistic beams are discussed and background compensation techniques to obtain high signal-to-noise ratio are explored. From these preliminary tests, electro-optic sampling is suitable to be a reliable nondestructive time stamping method for relativistic ultrafast electron diffraction at the Pegasus lab.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser-induced breakdown spectroscopy using mid-infrared femtosecond pulses

Here, we report on a laser-induced breakdown spectroscopy (LIBS) experiment driven by mid-infrared (2.05-μm) fs pulses, in which time-resolved emission spectra of copper were studied. Ab-initio modeling is consistent with the results of new fs measurements at 2.05 μm and traditional 800-nm fs-LIBS. Ablation by mid-infrared fs pulses results in a plasma with a lower plasma density and temperature compared to fs-LIBS performed at shorter laser wavelength. LIBS driven by mid-infrared fs pulses results in a signal-to-background ratio ~50% greater and a signal-to-noise ratio ~40% lower than fs-LIBS at near-infrared laser wavelength.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhanced ring lasers: a new measurement tool for Earth sciences

We report the progress in the technology of fabrication of large ring lasers that has resulted in an increase in instrumental rotation sensitivity by as much as a factor of 3, to {delta}{Omega} = 1.2 Multiplication-Sign 10{sup -11} rad s{sup -1} Hz{sup -1/2}, which makes the domain of changes in the angular velocity of Earth's rotation, {Delta}{Omega}/{Omega} Almost-Equal-To 10{sup -9}, accessible to a local rotation sensor. New studies show that the largest contribution to the observed deviation in sensor performance with respect to the computed shot noise limit is caused by the micro-seismic background activity of the Earth. Our efforts have been concentrated on the improvement of sensor stability, including correction of drift effects, which are caused by the aging of the laser gas, fixing scale factor instabilities induced by atmospheric pressure variations, and minimising the temperature variations resulting from corresponding adiabatic expansion and compression of the local air around the instrument. To achieve this, we have recently introduced a pressure-stabilising vessel with dimensions slightly larger than the ring laser apparatus, such that it encloses the entire structure. By monitoring the optical frequency in the ring laser cavity continuously and stabilising the scale factor in a closed loop system with the pressure-stabilising vessel, it has become possible to extend the range of sensor stability from the short term (1 - 3 days) to well into the mid-term regime (>40 days), and possibly even well beyond that. Once a sufficiently long timeseries of the ring laser data has been recorded, we will be able to define the range of temporal stability in more detail. The extension of the regime of stability gives access to geophysical signals at frequencies substantially lower than previously observable with ring lasers. (laser applications and other topics in quantum electronics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

GW170817: Implications for the Stochastic Gravitational-Wave Background from Compact Binary Coalescences

The LIGO Scientific and Virgo Collaborations have announced the event GW170817, the first detection of gravitational waves from the coalescence of two neutron stars. The merger rate of binary neutron stars estimated from this event suggests that distant, unresolvable binary neutron stars create a significant astrophysical stochastic gravitational-wave background. The binary neutron star component will add to the contribution from binary black holes, increasing the amplitude of the total astrophysical background relative to previous expectations. In the Advanced LIGO-Virgo frequency band most sensitive to stochastic backgrounds (near 25 Hz), we predict a total astrophysical background with amplitude Ω GW ( f = 25 Hz ) = 1. 8 - 1.3 + 2.7 × 10 - 9 with 90% confidence, compared with Ω GW ( f = 25 Hz ) = 1. 1 - 0.7 + 1.2 × 10 - 9 from binary black holes alone. Finally, assuming the most probable rate for compact binary mergers, we find that the total background may be detectable with a signal-to-noise-ratio of 3 after 40 months of total observation time, based on the expected timeline for Advanced LIGO and Virgo to reach their design sensitivity.

79 ASTRONOMY AND ASTROPHYSICS↗