Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “water evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Performance Evaluation of a High Salinity Produced Water Treatment Train: Chemical Analysis and Aryl Hydrocarbon Activation

Water scarcity and increased energy demands have put a strong focus on improving industries at the heart of the water–energy nexus. Treatment of oil and gas produced water (PW) can help reduce freshwater consumption during hydraulic fracturing, especially in arid regions, while also removing harmful contaminants from entering the environment. However, it is also difficult to treat because PW contains high concentrations of many environmentally toxic contaminants, which require complex and expensive treatment processes to achieve their removal. To demonstrate the possibility of PW treatment and reuse in the O&G industry, a comprehensive environmental toxicity and water quality analysis throughout a five-process treatment train was performed on high salinity (>120 g/L) Permian basin raw PW. Here, the concentrations of naturally occurring radioactive materials were reduced by over 99%, total organic carbon was reduced by 93%, and inorganic constituents, including total dissolved solids, were reduced by over 99%. Compounds that induced the aryl hydrocarbon receptor and caused cytotoxicity in MCF-7 cells were also removed. Overall, the results of this study show that a short treatment train (five distinct unit processes) can be effective in treating PW to a level suitable for use outside of the oil industry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of Floating PV (FPV) System on Water Evaporation: Case Study of an Open Loop Reservoir in North Carolina

Fresh water scarcity is becoming one of the important concerns worldwide. This situation of water scarcity is further exacerbated by the increase in water evaporation due to climate change. This manuscript will address this concern by considering the impact of floating photovoltaics (FPVs) systems on water evaporation. The installation of PV modules on the water bodies can help reduce the water evaporation rate from reservoirs by reducing the evaporating area of the water surface. This work evaluates the effect of FPV on water evaporation rates in the TuckerTown reservoir located in North Carolina state of United States. Meteorological data, such as mean temperature and dew-point, are used to calculate the rate of the water evaporation by Linacre method. The simulation results for the TuckerTown case study showed that the aggregated avoided evaporated volume for one year is 9 million gallons.

14 SOLAR ENERGY↗

Evaluating T 2 Conversion to Tritiated Water under Ambient Conditions - Case Study

In 2015, an incident released approximately 40 Ci of T 2 gas directly into the Tritium Exhaust System. Data from a bubbler system that monitored the stack effluent during the time period encompassing the accident, from 9 days prior through approximately 26 hours following the release, indicated that approximately 0.25% of the total accumulated tritium gas was in the form of tritiated water; however this value does not account for sources of tritium exhaust from other building operations and processes during the 9 days prior to this incident. Further analysis of the bubbler data around this time period considered the 9-day background contributions and shows that the actual fraction of the tritium that was released as tritiated water vapor (during and within 26 hours after the release) was likely lower than 0.1%.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance Testing of Additively Manufactured 316L Stainless Steel in Light Water Reactor Environment

This report summarizes research activities conducted at Argonne National Laboratory in support of the development, qualification and certification of additively manufactured (AM) metallic components for the long-term sustainability of light water reactors. In this program, AM 316L stainless steel (SS) has been evaluated in light water reactor (LWR) environments for their fatigue, environmentally assisted fatigue, and stress corrosion cracking performances on specimens in as-printed condition, aiming for facilitating the regulatory acceptance and ultimately adoption of AM components in aging LWRs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Actions to Evaluate Tritium in ATR Complex Perched Water Well 12

On April 23, 2019, elevated tritium concentrations in monitoring well PW-12 were reported to the Advanced Test Reactor (ATR) Complex environmental manager by the Fluor Idaho Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) lead. The monitoring well is one of a series of wells located in and around the ATR Complex that are sampled on an annual basis as part of the CERCLA monitoring program. The Fluor Idaho CERCLA lead indicated the elevated concentrations had been trending upward from Fiscal Year (FY) 2017 through FY 2019. The tritium levels went from 1,880 pCi/L in October 2016 to 7,890 pCi/L in October 2017 and increased to 13,000 pCi/L in October 2018. In order to identify a baseline, the safe drinking water level (e.g. 20,000 pCi/L) can be used as a reference point for comparison only, as PW-12 is a perched water well and does not penetrate the aquifer. Although well below safe drinking water levels, an investigation was initiated to identify the source of tritium.

99 GENERAL AND MISCELLANEOUS↗

Technical, Economic, Energetic, and Environmental Evaluation of Pretreatment Strategies for Scaling Control in Brackish Water Desalination Brine Treatment

Effective pretreatment is essential for achieving long-term stable operation and high water recovery during the desalination of alternative waters. This study developed a process modeling approach for technical, economic, energetic, and environmental assessments of pretreatment technologies to identify the impacts of each technology treating brackish water desalination brine with high scaling propensity. The model simulations evaluated individual pretreatment technologies, including chemical softening (CS), chemical coagulation (CC), electrocoagulation (EC), and ion exchange (IX). In addition, combinations of these pretreatment technologies aiming at the effective reduction of key scaling constituents such as hardness and silica were investigated. The three evaluation parameters in this assessment consist of levelized cost of water (LCOW, $/m 3 ), specific energy consumption and cumulative energy demand (SEC|CED, kWh/m 3 ), and carbon dioxide emissions (CO 2 , kg CO 2-eq /m 3 ). The case study evaluated in this work was the desalination brine from the Kay Bailey Hutchison Desalination Plant (KBHDP) with a total dissolved solids (TDS) concentration of 11,000 mg/L and rich in hardness and silica. The evaluation of individual pretreatment units from the highest to lowest LCOW, SEC|CED, and CO 2 emissions in the KBHDP brine was IX > CS > EC > CC, CS > IX > EC > CC, and CC > CS > EC > IX, respectively. In the case of pretreatment combinations for the KBHDP, the EC + IX treatment combination was shown to be the best in terms of the LCOW and CO 2 emissions. The modeling and evaluation of these pretreatment units provide valuable guidance on the selection of cost-effective, energy-efficient, and environmentally sustainable pretreatment technologies tailored to desalination brine applications for minimal- or zero-liquid discharge.

14 SOLAR ENERGY↗

Exploring Afro-Asian water fluxes in CMIP5 and CMIP6 models: Present-day evaluation and future projections

Accurate representation and projection of water fluxes are vital, particularly in monsoon regions where seasonal variability and changes significantly impact water resources, agriculture, hydroelectric power generation, and the economy. This study uses both CMIP5 and CMIP6 models to investigate the present-day representation of key water flux components (including precipitation, evaporation, water vapor, and moisture advection) over the Afro-Asian region during the summer monsoon (JJAS). We also examine future changes under two emission scenarios and assess the underlying physical mechanisms driving these changes while identifying sources of projection uncertainty. Our results show that both models reasonably capture the present-day characteristics of water flux components, although with noticeable biases. Across most regions, we find that CMIP6 models demonstrate slight improvements over CMIP5 in the representation of these components. In a warmer future, a robust intensification of JJAS precipitation (exceeding 0.25 mm/day) is projected across the Afro-Asian region. This increase is largely driven by the vertical thermodynamic term associated with increasing temperature. We find that model uncertainty is the primary source of uncertainty in water flux projections, accounting for over 50 % of the total variance.

Climate change↗

Thermodynamic Model and Initial Experimental Investigation of Air Dehumidification through Electrically Charged Vapor Capturing Electrostatic Droplets

The removal of water vapor from the air to reduce relative humidity is a well known indoor environmental comfort requirement. Common dehumidification approaches require a substantial amount of energy and usually involve the cooling of atmospheric humid air below its dew point or the use of absorbent/adsorbent materials to extract water vapor out of the air. More recently, researchers investigated the effect of electrostatic forces for enhancing water vapor condensation with the goal to reduce the energy consumption associated with dehumidification. However, the studies are limited, and there is a lack of correlations that can predict the dehumidification rate. In this thesis, a broad theoretical investigation to study the electrostatically enhanced condensation processes was carried out. These processes consist of the use of highly charged particles, preferably highly charged water droplets to attract polar water vapor molecules to their surfaces and promote condensation, a phenomenon known as dielectrophoresis. The electrical charge promotes the reduction of the vapor pressure on the droplets' surface with respect to the saturated pressure predicted by the Kelvin equation on curved surfaces and, consequently, the equilibrium between evaporation and condensation is shifted towards condensation. This investigation resulted in the development of a thermodynamics model, which was able to predict an effective size range of the charged droplets for optimal dehumidification, under ideal conditions. The range resulted in about 2 to 4 m in diameter, while the electrical charge was kept to the maximum limit predicted by the Rayleigh model. A sensitivity analysis on the variation of the size and the charge of the charged droplets was also performed. In terms of dehumidification rates, when six electrospray heads, i.e. the maximum number of heads tested in the experimental campaign, were considered, the model predicted very limited rates, way lower than the target of this research, i.e. a dehumidification rate in terms of relative humidity of 5 % with an air flow rate of 5 cfm. While ways to increase this rate existed, their implementation proved difficult for this initial investigation. According to the requirements predicted by the model, the use of electrosprays appeared the most suitable solution for the production of small but highly charged droplets. The electrospray features and operational modes were studied in detail and an electrospray assembly was designed to be tested in this initial experimental investigation. For this initial investigation, an experimental system was designed and built to validate the thermodynamics model and with the goal to achieve a dehumidification rate of 5 % in terms of relative humidity with an air flow rate of 5 cfm. The experimental system consisted of a wind tunnel test apparatus, dew point sensors, thermocouples for temperature measurements, pressure sensors and other devices. The experimental system was equipped with a computerized data acquisition and storage system. The system was suitable to evaluate the air water content differential before and after the test section where the electrospray heads were installed. The air water content differential was evaluated in terms of the ∆ω/ω_1 ratio, to eliminate the dependence on the dry bulb temperature along the test apparatus. This work presented initial experimental data for electrostatically enhanced dehumidification processes. Working parameters, such as air and water flow rates, high voltage potentials and polarity, deionized water types with different electrical conductivity, were varied to find the best combination for an improved dehumidification. With the set up used and the conditions considered, it was never possible to achieve a 5 % dehumidification rate with 5 cfm. In general, the dehumidification rate was always limited and lower than 1 % for all the air flow rates considered and mainly within the uncertainty of the dew point sensors. These results confirmed the already limited predictions of the thermodynamics model, for ideal conditions and the interesting and promising results obtained in some experimental investigations available in the open literature were not achievable in this thesis. The more probable reasons were the higher air flow rates considered and the complete absence of the use of cooling power, which was mainly implemented to facilitate the vapor condensation.

Morcelli, Stefano↗

Hybrid Cooling and Water Treatment for Resilient, Water-Self-Sufficient Data Centers

The continued growth of data center infrastructure is intensifying demand for freshwater resources, particularly in water-stressed regions, and is increasingly limiting sustainable capacity expansion. This work investigates a conceptual hybrid system that integrates freeze desalination with ultrasonic-assisted ice separation to enable on-site production of pure water from diverse sources, including seawater, brackish groundwater, and reclaimed industrial or agricultural wastewater. Simultaneously, the system produces low-temperature cooling streams that enhance heat removal in high power density computing environments. A process-level thermodynamic analysis is performed across a range of boundary and operating conditions, including variations in feed concentration, freezing temperature, and mass flow rate. The results are presented as performance curves relating feedwater concentration and target purified water output to the corresponding intake flow requirements, enabling estimation of source water demand per unit of Information Technology Equipment (ITE) energy consumption (kWh) across varying data center scales and operational scenarios. The corresponding electrical energy consumption for integrated cooling and water treatment is also evaluated as a function of system operating parameters and target water production levels. These results provide a basis for evaluating system feasibility across different conditions and for identifying parameter ranges in which integrated water treatment and cooling improve resource efficiency, thermal performance, and operational flexibility in data centers.

Elhefny, Aly [ORNL] (ORCID:0000000284907923)↗

Model Data Archive for Manuscript Titled "Evaluation of a Coupled Surface–Subsurface Hydrologic Model Using Dense Water‑Level Sensors in a Mixed Urban–Rural Watershed"

This archive provides scripts, input files, and datasets used for the implementation and evaluation of a fully coupled surface–subsurface hydrologic model in the Neches River Basin, southeast Texas. The study uses the Advanced Terrestrial Simulator (ATS) to simulate coupled surface–subsurface hydrologic processes over a mixed urban–rural watershed and evaluates model performance using a dense network of 136 in situ water-level sensors, nine U.S. Geological Survey (USGS) stream gauges, and SSEBop-derived evapotranspiration estimates during the period October 2014–June 2024. The workflow is implemented primarily in Python 3 using the Watershed Workflow package. The Jupyter notebooks can be executed using open-source software such as Anaconda JupyterLab or Visual Studio Code. Other data files include TXT, CSV, XML, SHP, TIF, NetCDF, HDF5, and ExodusII files, which can be processed using the provided Python scripts. ATS input files are provided in XML format and can be edited using any commonly used text editor. This archive contains: *Scripts and input files used to generate the ATS model setup, including watershed discretization, mesh generation, parameter mapping, and model configuration. *Jupyter notebooks used for preprocessing observational data, evaluating streamflow, water levels, and evapotranspiration, computing performance metrics, and generating the figures presented in the manuscript. *ATS simulation outputs and processed observational datasets, including OneRain and DD6 water-level sensors, USGS streamflow observations, GIS data, and supporting spatial datasets used throughout the study.

Dense water-level sensor network↗

High-resolution neutron time-of-flight measurements for light water at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory

Series of light water inelastic neutron scattering experiments have been made at the Oak Ridge National Laboratory (ORNL), Spallation Neutron Source (SNS) covering temperatures ranging from 295 K to 600 K and pressures of 1 bar and 150 bar. The temperatures and pressures ranges correspond to that of pressurized light water reactors. The inelastic scattering measurements will help the development of light water thermal scattering kernels, also known as S (α,β) thermal scattering law (TSL), in a consistent fashion given the amount and the quality of the measured data. Light water thermal scattering evaluations available in existing nuclear data libraries have certain limitations and pitfalls. This paper introduces the state of the art of the light water thermal scattering cross-section data not only for room temperature but as well as for reactor operating temperatures, i.e. 550 - 600 K. During the past few years there has been a renewed interest in re-investigating the existing TSL models and utilize the recent experimental data or perform molecular dynamics simulations. It should be pointed out that no single TSL evaluation is based entirely on experimental data and one has to rely on TSL models or a combination of both. New TOF measurement of light water at the SNS, with a detailed description of the experimental setup, measurement conditions, and the associated foreseen results is presented in this paper. The analysis of the experimental data would help in validating the existing approach based on old experimental data or based on molecular dynamic simulations using classical water models, knowledge of which is very important to generate TSL libraries at reactor operating conditions.

Leal, Luiz C.↗

MODFLOW6 models used to evaluate potential stresses and hydrologic conditions driving water-level fluctuations in well ER-5-3-2, Frenchman Flat, Southern Nevada

The hydrograph for well ER-5-3-2 in Frenchman Flat, southern Nevada, has previously unexplained water-level fluctuations. Four, three-dimensional, groundwater models (MODFLOW 6) were developed to evaluate potential stresses and hydrologic conditions affecting the well ER-5-3-2 hydrograph. Four model scenarios were developed that simulated: (1) wellbore leakage without recharge, (2) wellbore leakage with recharge, (3) shallow (low transmissivity) and deep (high transmissivity) carbonate rocks, and (4) lateral heterogeneity of carbonate rocks. Input and output files for the four model scenarios are in the model and output directories, respectively. Hydraulic conductivity, specific storage, and wellbore-leakage rates (when simulated) were estimated with parameter estimation (PEST) by minimizing a weighted composite, sum-of-squares objective function. The objective function was informed by measurement and Tikhonov regularization observations. Measurement observations included drawdowns from the constant-rate aquifer test and water-level altitudes measured in well ER-5-3-2 from 2001-2021. Tikhonov regularization informed hydraulic conductivity and specific storage parameters that were insensitive to measurement observations, where homogeneity was the preferred relation. Batch files, executables, and MODFLOW 6, PEST, and post-processing utilities are in the ancillary directory. Supplementary data also are included in the ancillary directory, including site information, high-frequency water-level and aquifer-test data, transmissivity estimates, water-chemistry data, and water-temperature analyses. This USGS data release contains data, analyses, and model files for the simulations and analysis results described in U.S. Geological Survey Scientific Investigations Report (https://doi.org/10.3133/sir20225132).

54 ENVIRONMENTAL SCIENCES↗

Long-Term Monitoring & Stewardship at Los Alamos National Laboratory [Slides]

Development and implementation of the Institutional Control Evaluation Project will include: Evaluate institutional surface water controls and infrastructure installed by LANL. Implement pilot project in the Los Alamos Canyon Watershed Spring, 2020. Initial evaluations will include canyon bottom controls with plan to expand program as funding allows. This will be a building block for successful Long-Term Monitoring and Stewardship (LTM&S) Program.

54 ENVIRONMENTAL SCIENCES↗

Dynamic regulation of water potential in Juniperus osteosperma mediates ecosystem carbon fluxes

Summary Some plants exhibit dynamic hydraulic regulation, in which the strictness of hydraulic regulation (i.e. iso/anisohydry) changes in response to environmental conditions. However, the environmental controls over iso/anisohydry and the implications of flexible hydraulic regulation for plant productivity remain unknown. InJuniperus osteosperma, a drought‐resistant dryland conifer, we collected a 5‐month growing season time series ofin situ, high temporal‐resolution plant water potential () and stand gross primary productivity (GPP). We quantified the stringency of hydraulic regulation associated with environmental covariates and evaluated how predawn water potential contributes to empirically predicting carbon uptake. Juniperus osteospermashowed less stringent hydraulic regulation (more anisohydric) after monsoon precipitation pulses, when soil moisture and atmospheric demand were high, and corresponded with GPP pulses. Predawn water potential matched the timing of GPP fluxes and improved estimates of GPP more strongly than soil and/or atmospheric moisture, notably resolving GPP underestimation before vegetation green‐up. Flexible hydraulic regulation appears to allowJ. osteospermato prolong soil water extraction and, therefore, the period of high carbon uptake following monsoon precipitation pulses. Water potential and its dynamic regulation may account for why process‐based and empirical models commonly underestimate the magnitude and temporal variability of dryland GPP.

Plant Sciences↗

Evaluation of the Sum-of-Fractions Methodology for Water and Polyethylene Moderated Systems

Sum-of-Fractions is a method intended to assure a subcritical margin for aqueous solutions and slurries of fissionable isotopes. The method indicates that a system is subcritical if the sum of the ratios of the mass of each isotope in a mixture to its individual minimum subcritical mass limit is less than or equal to one. The basis of the Sum-of Fractions has historically been derived from allowances given in ANSI/ANS-8.15-1981. However, the allowance was removed in ANSI/ANS-8.15-2014 due to a lack of technical basis. A methodology was developed to assess the validity of using the Sum-of-Fractions for water or polyethylene moderated systems for the following nuclides: 232 U, 233 U, 234 U, 235 U, 237 Np, 236 Pu, 238 Pu, 239 Pu, 240 Pu, 241 Pu, 242 Pu, 241 Am, 242 mAm, 243 Am, 242 Cm, 243 Cm, 244 Cm, 245 Cm, 246 Cm, 247 Cm, 249 Cf, and 251 Cf. The methodology uses available benchmark data for mixtures of 233 U, 235 U, and 239 Pu to establish the calculational margin, and a mass limit reduction to establish the margin of subcriticality. Water or polyethylene moderated and reflected mixtures containing the nuclides are evaluated with SCALE 6.2.4. Including the calculational margin, subcritical mass limits for each nuclide were computed for optimally water or polyethylene moderated and fully reflected systems. These masses were used to create nuclide mixtures in which the sum of the mass to subcritical mass limit ratios is one. The various nuclide mixtures were modeled over a range of moderation and demonstrate the k eff does not exceed the calculational margin. For additional assurance of subcriticality, a significant mass reduction is applied to each computed minimum critical mass of the nuclides without adequate benchmark data consistent with the method in ANSI/ANS-8.15-2014.

07 ISOTOPE AND RADIATION SOURCES↗

Neutronic Characteristics of ENDF/B-VIII.0 Compared to ENDF/B-VII.1 for Light-Water Reactor Analysis

The Evaluated Nuclear Data File (ENDF)/B-VIII.0 data library was released in 2018. To assess the new data during development and shortly after release, many validation calculations were performed with static, room-temperature benchmarks. Recently, when performing validation of ENDF/B-VIII.0 for pressurized water reactor depletion calculations, a regression in performance compared to ENDF/B-VII.1 was observed. This paper documents extensive benchmark calculations for light-water reactors performed using continuous energy Monte Carlo code with ENDF/B-VII.1 and -VIII.0 and neutronic characteristics of ENDF/B-VIII.0 are discussed and compared to those of ENDF/B-VII.1. It is our recommendation that ENDF/B data library assessment should include reactor-specific benchmark assessments, including depletion cases, such that these types of regressions may be caught earlier in the data development cycle.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Performance of Different Water-Based Binder Formulations for Ni-Rich Cathodes Evaluated in LiNi 0.8 Mn 0.1 Co 0.1 O 2 //Graphite Pouch Cells

Water-based processing for lithium-ion battery electrodes is attractive due to its lower manufacturing cost and smaller environmental impact. However, multiple challenges associated with aqueous cathode processing have hindered commercial adoption. Polymer binders are an important component of the electrode, and thus the choice of binders can alter electrode cycling performance significantly. In this work, four different water-based binder combinations are investigated for Ni-rich LiNi 0.8 Mn 0.1 Co 0.1 O 2 (NMC811)-based cathodes, with a focus on the long-term electrochemical performance in practical-format full pouch cells. No additional pH-modulating additives were added to the aqueous cathode slurries, and no protective coatings were present on the cathode or aluminum current collector. Results are compared with the standard PVDF/NMP-based binder/solvent combination, used as a baseline. The influence of water-based binder type on slurry rheology and electrode microstructure are also discussed. All cells made by water-processing had worse rate performance compared to the baseline. However, the cell discharge capacity after 1000 U.S. Advanced Battery Consortium (USABC) cycles at C/3 charge/discharge rate was comparable to the baseline for two of the water-based cathode formulations (CMC & JSR, and LiPAA), demonstrating the potential viability of aqueous-processed Ni-rich cathodes at a commercial scale.

25 ENERGY STORAGE↗