Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “wall insulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Method of hybrid plume plasma propulsion

A technique for producing thrust by generating a hybrid plume plasma exhaust is disclosed. A plasma flow is generated and introduced into a nozzle which features one or more inlets positioned to direct a flow of neutral gas about the interior of the nozzle. When such a neutral gas flow is combined with the plasma flow within the nozzle, a hybrid plume is constructed including a flow of hot plasma along the center of the nozzle surrounded by a generally annular flow of neutral gas, with an annular transition region between the pure plasma and the neutral gas. The temperature of the outer gas layer is below that of the pure plasma and generally separates the pure plasma from the interior surfaces of the nozzle. The neutral gas flow both insulates the nozzle walls from the high temperatures of the plasma flow and adds to the mass flow rate of the hybrid exhaust. The rate of flow of neutral gas into the interior of the nozzle may be selectively adjusted to control the thrust and specific impulse of the device.

Chang, Franklin R.↗

Buoyancy-driven flows of a radiatively participating fluid in a vertical cylinder heated from below

The effect of radiative energy transport on the onset and evolution of natural convective flows is studied in a Rayleigh-Benard system. Steady, axisymmetric flows of a radiatively participating fluid contained in a rigid-walled, vertical cylinder which is heated on the base, cooled on top, and insulated on the side wall are calculated by using the Galerkin FEM. Bifurcation analysis techniques are used to investigate the changes in the flow structure due to internal radiation. The results of this two-parameter study - where the Rayleigh number, Ra and optical thickness, tau, are varied - apply to fluids ranging from opaque to nearly transparent with respect to IR radiation. For any nonopaque fluid, internal radiation eliminates the static state that without radiation, exists for all values of the Rayleigh number. This heat transfer mechanism also destroys a symmetry of the system that relates clockwise and counterclockwise flows. The connectivity between characteristic flow families and the range of Ra where families are stable are found to depend greatly on tau. Results demonstrate the inadequacy of characterizing the behavior of this system using simple notions of radiative transfer in optically thick or thin media; the nonlinear interaction of radiation and flow are far more complicated than these asymptotic limits would imply.

Salinger, A. G.↗

Cryogenic Insulation Bondline Studies for Reusable Launch Vehicles

Cryogenic insulations bonded to metallic substrates were characterized under simulated mission conditions representative for a reusable launch vehicle. The combined thermal and mechanical test consisted of 50 to a 100 cycles. These combined thermal and mechanical cycles simulated flight missions with temperatures ranging from -423 F to 450 F and a maximum mechanical tension load ranging from 20,000 lbs. to 97,650 lbs. The combined thermal and mechanical (uniaxial tension) test apparatus (1 ft. by 2 ft. Test Apparatus) developed at the NASA Langley Research Center, was used to perform cyclic tests on cryogenic insulations bonded to tank wall substrates. No visual delamination or degradation was observed in the cryogenic insulation-to-metallic substrate bondline or butt joints between cryogenic insulation panels. In addition, after cyclic testing was performed, residual property results from tension-pull and closed-cell content tests of the cryogenic insulations indicated a decrease in the bondline strength and closed-cell content.

Johnson, T. F.↗

Home Insulation With the Stroke of a Brush

Hy-Tech Thermal Solutions, LLC, of Melbourne, Florida, is producing a very complex blend of ceramic vacuum-filled refractory products designed to minimize the path of hot air transfer through ceilings, walls, and roofs. The insulating ceramic technology blocks the transfer of heat outward when applied to paint on interior walls and ceilings, and prevents the transfer of heat inward when used to paint exterior walls and roofs, effectively providing year-round comfort in the home. As a manufacturer and marketer of thermal solutions for residential, commercial, and industrial applications, Hy-Tech Thermal Solutions attributes its success to the high performance insulating ceramic microsphere originally developed from NASA thermal research at Ames Research Center. Shaped like a hollow ball so small that it looks as if it is a single grain of flour to the naked eye (slightly thicker than a human hair), the microsphere is noncombustible and fairly chemical-resistant, and has a wall thickness about 1/10 of the sphere diameter, a compressive strength of about 4,000 pounds per square inch, and a softening point of about 1,800 C. Hy-Tech Thermal Solutions improved upon these properties by removing all of the gas inside and creating a vacuum. In effect, a 'mini thermos bottle' is produced, acting as a barrier to heat by reflecting it away from the protected surface. When these microspheres are combined with other materials, they enhance the thermal resistance of those materials. In bulk, the tiny ceramic 'beads' have the appearance of a fine talcum powder. Their inert, nontoxic properties allow them to mix easily into any type of paint, coating, adhesive, masonry, or drywall finish. Additionally, their roundness causes them to behave like ball bearings, rolling upon each other, and letting the coatings flow smoothly. When applied like paint to a wall or roof, the microsphere coating shrinks down tight and creates a dense film of the vacuum cells. The resulting ceramic layer improves fire resistance, protects from ultraviolet rays, repels insects such as termites, and shields from the destructive forces of nature.

Source record↗

Demonstration of a Particle Impact Monitoring System for Crewed Space Exploration Modules

When micrometeorite or debris impacts occur on a space habitat, crew members need to be quickly informed of the likely extent of damage, and be directed to the impact location for possible repairs. The goal of the Habitat Particle Impact Monitoring System (HIMS) is to develop a fully automated, end-to-end particle impact detection system for crewed space exploration modules, both in space and on the surfaces of Solar System bodies. The HIMS uses multiple thin film piezo-polymer vibration sensors to detect impacts on a surface, and computer processing of the acoustical signals to characterize the impacts. Development and demonstration of the HIMS is proceeding in concert with NASA's Habitat Demonstration Unit (HDU) Project. The HDU Project is designed to develop and test various technologies, configurations, and operational concepts for exploration habitats. This paper describes the HIMS development, initial testing, and HDU integration efforts. Initial tests of the system on the HDU were conducted at NASA?s 2010 Desert Research and Technologies Studies (Desert-RATS). Four sensor locations were assigned near the corners of a rectangular pattern. To study the influence of wall thickness, three sets of four sensors were installed at different layer depths: on the interior of the PEM wall, on the exterior of the same wall, and on the exterior of a layer of foam insulation applied to the exterior wall. Once the system was activated, particle impacts were periodically applied by firing a pneumatic pellet gun at the exterior wall section. Impact signals from the sensors were recognized by a data acquisition system when they occurred, and recorded on a computer for later analysis. Preliminary analysis of the results found that the HIMS system located the point of impact to within 8 cm, provided a measure of the impact energy / damage produced, and was insensitive to other acoustic events. Based on this success, a fully automated version of this system will be completed and demonstrated as part of a crew "Caution/Warning" system at the 2011 Desert-RATS, along with a crew response procedure.

Opiela, J. N.↗

Maximum Expected Wall Heat Flux and Maximum Pressure After Sudden Loss of Vacuum Insulation on the Stratospheric Observatory for Infrared Astronomy (SOFIA) Liquid Helium (LHe) Dewars

The aircraft-based Stratospheric Observatory for Infrared Astronomy (SOFIA) is a platform for multiple infrared observation experiments. The experiments carry sensors cooled to liquid helium (LHe) temperatures. A question arose regarding the heat input and peak pressure that would result from a sudden loss of the dewar vacuum insulation. Owing to concerns about the adequacy of dewar pressure relief in the event of a sudden loss of the dewar vacuum insulation, the SOFIA Program engaged the NASA Engineering and Safety Center (NESC). This report summarizes and assesses the experiments that have been performed to measure the heat flux into LHe dewars following a sudden vacuum insulation failure, describes the physical limits of heat input to the dewar, and provides an NESC recommendation for the wall heat flux that should be used to assess the sudden loss of vacuum insulation case. This report also assesses the methodology used by the SOFIA Program to predict the maximum pressure that would occur following a loss of vacuum event.

Ungar, Eugene K.↗

Hypervelocity impact damage assessment for Space Station

To inhibit damage and limit the probability of penetration of the Space Station pressure wall by micrometeoroids and orbital debris, a shield placed away from the wall is used to form a double wall. To determine shield effectiveness and assess impact damage, existing test data were reviewed and additional testing was performed for Space Station double wall designs. Empirical spallation and penetration functions derived from the data show that shield thickness and impact angle affect the damage to the wall. Thick shields reduce wall damage for low angle impacts but increase damage for oblique impacts. Multilayer insulation between the shield and wall reduces impact damage to the wall. A relationship between impact velocity and spall damage to the wall is demonstrated. Preliminary test results on Li-Al shield material indicate possible improved effectiveness over Al shields.

Coronado, Alex R.↗

Cryogenic Insulation System

This invention relates to reusable, low density, high temperature cryogenic foam insulation systems and the process for their manufacture. A pacing technology for liquid hydrogen fueled, high speed aircraft is the development of a fully reusable, flight weight cryogenic insulation system for propellant tank structures. In the invention cryogenic foam insulation is adhesively bonded to the outer wall of the fuel tank structure. The cryogenic insulation consists of square sheets fabricated from an array of abutting square blocks. Each block consists of a sheet of glass cloth adhesively bonded between two layers of polymethacrylimide foam. Each block is wrapped in a vapor impermeable membrane, such as Kapton(R) aluminum Kapton(R), to provide a vapor barrier. Very beneficial results can be obtained by employing the present invention in conjunction with fibrous insulation and an outer aeroshell, a hot fuselage structure with an internal thermal protection system.

Davis, Randall C.↗

Cryogenic testing of a foam-multilayer insulation concept in a simulated prelaunch environment

NASA-Marshall has devised an upper-stage vehicle-applicable reusable cryogenic insulation thermal-control system which employs spray-on foam insulation (SOFI) that is attached to the cryotank wall and covered by 17-sheet multilayer insulation composed of double-aluminized mylar and Dacron scrim. Four prelaunch test simulations have been conducted for the case of LH2 with gaseous N2 purge gas. Test results indicate that the SOFI surface temperature was sufficiently high to preclude atmospheric oxygen and nitrogen liquefaction.

Martin, James J.↗

External Tank (ET) Foam Thermal/Structural Analysis Project

An independent study was performed to assess the pre-launch thermally induced stresses in the Space Shuttle External Tank Bipod closeout and Ice/Frost ramps (IFRs). Finite element models with various levels of detail were built that included the three types of foam (BX-265, NCFI 24-124, and PDL 1034) and the underlying structure and bracketry. Temperature profiles generated by the thermal analyses were input to the structural models to calculate the stress levels. An area of high stress in the Bipod closeout was found along the aluminum tank wall near the phenolic insulator and along the phenolic insulator itself. This area of high stress might be prone to cracking and possible delamination. There is a small region of slightly increased stress in the NCFI 24-124 foam near its joint with the Bipod closeout BX-265 foam. The calculated stresses in the NCFI 24-124 acreage foam are highest at the NCFI 24-124/PDL 1034/tank wall interface under the LO2 and LH2 IFRs. The highest calculated stresses in the LH2 NCFI 24-124 foam are higher than in similar locations in the LO2 IFR. This finding is consistent with the dissection results of IFRs on ET-120.

Moore, David F.↗

Lightweight High-Temperature Thermal Insulation

Fine Ni/Cr fibers sintered into corrosion-resistant, fireproof batt. Possible applications include stoves, furnaces, safes, fire clothing, draperies in public buildings, wall firebreaks, airplane walls, and jetengine components. New insulation takes advantage of some of same properties of nickel/chromium alloy useful in heating elements in toasters, namely, corrosion and oxidation resistance even at high temperatures.

Wagner, W. R.↗

Cellulose Insulation

Fire retardant cellulose insulation is produced by shredding old newspapers and treating them with a combination of chemicals. Insulating material is blown into walls and attics to form a fiber layer which blocks the flow of air. All-Weather Insulation's founders asked NASA/UK-TAP to help. They wanted to know what chemicals added to newspaper would produce an insulating material capable of meeting federal specifications. TAP researched the query and furnished extensive information. The information contributed to successful development of the product and helped launch a small business enterprise which is now growing rapidly.

Source record↗

Magnetically Actuated Propellant Orientation, Controlling Fluids in a Low-Gravity Environment

Cryogenic fluid management (CFM) is a technology area common to virtually every space transportation propulsion concept envisioned. Storage, supply, transfer and handling of sub-critical cryogenic fluids are basic capabilities that have long been needed by multiple programs and the need is expected to continue in the future. The use of magnetic fields provides another method, which could replace or augment current/traditional approaches, potentially simplifying vehicle operational constraints. The magnetically actuated propellant orientation (MAPO) program effort focused on the use of magnetic fields to control fluid motion as it relates to positioning (i.e. orientation and acquisition) of a paramagnetic substance such as LO2. Current CFM state- of-the-art systems used to control and acquire propellant in low gravity environments rely on liquid surface tension devices which employ vanes, fine screen mesh channels and baskets. These devices trap and direct propellant to areas where it's needed and have been used routinely with storable (non-cryogenic) propellants. However, almost no data exists r,egarding their operation in cryogenics and the use of such devices confronts designers with a multitude of significant technology issues. Typical problems include a sensitivity to screen dry out (due to thermal loads and pressurant gas) and momentary adverse accelerations (generated from either internal or external sources). Any of these problems can potentially cause the acquisition systems to ingest or develop vapor and fail. The use of lightweight high field strength magnets may offer a valuable means of augmenting traditional systems potentially mitigating or at least easing operational requirements. Two potential uses of magnetic fields include: 1) strategically positioning magnets to keep vent ports clear of liquid (enabling low G vented fill operations), and 2) placing magnets in the center or around the walls of the tank to create an insulating vapor pocket (between the liquid and the tank wall) which could effectively lower heat transfer to the liquid (enabling increased storage time).

Martin, James J.↗

Development of thermal stratification and destratification scaling concepts. Volume 1: Definition of thermal stratification scaling parameters and experimental investigations

The dimensionless parameters associated with the thermal stratification and pressure history of a heated container of liquid and its vapor were examined. The Modified Grashof number, the Fourier number, and an Interface number were parameterized using a single test liquid, Freon 113. Cylindrical test tanks with spherical dome end caps were built. Blanket heaters covered the tanks and thermocouples monitored the temperatures of the liquid, the ullage, the tank walls, and the foam insulation encapsulating the tank. A centrifuge was used for the 6 inch tank to preserve the same scaling parameter values between it and the larger tanks. Tests were conducted over a range of Gr* values and the degree of scaling was checked by comparing the dimensionless pressures and temperatures for each scaled pair of tests. Results indicate that the bulk liquid temperature, the surface temperature of the liquid, and the tank pressure can be scaled with the three dimensionless parameters. Some deviation was, however, found in the detailed temperature profiles between the scaled pairs of tests.

Lovrich, T. N.↗

Lightweight cryogenic vessel

Thin cooling jacket of recirculating liquid nitrogen is contained by relatively thin walls. Nitrogen is maintained at slight positive pressure, unlike full atmospheric pressure of conventional Dewar design, eliminating need for evacuated insulating spaces and heavy-walled shells. Besides cryogenic applications, design keeps liquids hot when recirculating liquid hotter than nitrogen is used.

Lewis, J. C.↗

Novel technique to measure the microwave response of high T(c) superconductors between 4.2 and 200 K

This paper describes a novel technique for measurements of the complex surface impedance Z(s) of high-T(c) superconductors over an extremely wide range of temperature, from 4.2 K and at least 200 K. The technique uses a superconducting Pb-plated Cu high-Q-cavity resonator operated at an ambient temperature of 4.2 K, with the sample (typically a 3-mm-diam x 1-mm-thick disk) mounted on a sapphire rod in the center of cavity, at a high B-field and thermally insulated from the cavity walls, making it possible to control the sample temperature externally. Since the cavity characteristics are dominated by the sample properties (the contribution of the Pb-covered walls maintained at 4.2 K is negligible), measurement of the cavity Q and resonant frequency makes it possible to measure Zs as a function of the sample temperature. The Z(s) values for bulk Y1Ba2Cu3O(y) and La(1.85)Sr(0.15)CuO4 were measured over a temperature range 4.2-100 K.

Sridhar, S.↗