An electro-mechanical dc voltage amplifier
Direct current voltage amplifier utilizing principles of servo system for gain stability
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Direct current voltage amplifier utilizing principles of servo system for gain stability
The underlying philosophy of the Global Positioning System (GPS) 2R Time Standard Assembly (TSA) architecture is to utilize two frequency sources, one fixed frequency reference source and one system frequency source, and to couple the system frequency source to the reference frequency source via a sample data loop. The system source is used to provide the basic clock frequency and timing for the space vehicle (SV) and it uses a voltage controlled crystal oscillator (VCXO) with high short term stability. The reference source is an atomic frequency standard (AFS) with high long term stability. The architecture can support any type of frequency standard. In the system design rubidium, cesium, and H2 masers outputting a canonical frequency were accommodated. The architecture is software intensive. All VCXO adjustments are digital and are calculated by a processor. They are applied to the VCXO via a digital to analog converter.
A new successive-approximation A/D converter is described. It combines a string of equal-valued polysilicon resistors and a set of ratioed capacitors in a unique circuit configuration so that a high sampling rate is achieved. The comparator is realized by a chopper-stabilized amplifier to reduce the effect of the offset voltages of MOS amplifiers. The converter performs an 8-b monotonic conversion with a differential nonlinearity less than 1 LSB in 770 nsec. The die area is 3750 sq mil. This new conversion technique can also be utilized in a pipelined A/D converter (Temes, 1985) and enables it to achieve high speed.
NASAs Hall Effect Rocket with Magnetic Shielding (HERMeS) 12.5 kW Technology Demonstration Unit-1 (TDU-1) Hall thruster has been the subject of extensive technology maturation in preparation for flight system development. Part of the technology maturation effort included experimental evaluation of the TDU-1 thruster with conducting and dielectric front pole cover materials in two different electrical configurations. A graphite front pole cover thruster configuration with the thruster body electrically tied to cathode and an alumina front pole cover thruster configuration with the thruster body floating were evaluated. Both configurations were also evaluated at different facility background pressure conditions to evaluate background pressure effects on thruster operation. Performance characterization tests found that higher thruster performance was attained with the graphite front pole cover configuration with the thruster electrically tied to cathode. A total thrust efficiency of 68 and a total specific impulse of 2,820 s was demonstrated at a discharge voltage of 600 V and a discharge power of 12.5 kW. Thruster stability regimes were characterized with respect to the thruster discharge current oscillations and with maps of the current-voltage-magnetic field (IVB). Analysis of TDU-1 discharge current waveforms found that lower normalized discharge current peak-to-peak and root mean square magnitudes were attained when the thruster was electrically floated with alumina front pole covers. Background pressure effects characterization tests indicated that the thruster performance and stability was mostly invariant to changes in the facility background pressure for vacuum chamber pressure below 110-5 Torr-Xe (for thruster flow rate above 8 mgs). Power spectral density analysis of the discharge current waveform showed that increasing the vacuum chamber background pressure resulted in a higher discharge current dominant frequency. Finally the IVB maps of the TDU-1 thruster taken at elevated magnetic fields indicated that the discharge current became more oscillatory with increased facility background pressure at lower thruster mass flow rates, where thruster operation at higher flow rates resulted in less change to the thrusters IVB characteristics.
NASA's Hall Effect Rocket with Magnetic Shielding (HERMeS) 12.5 kW Technology Demonstration Unit-1 (TDU-1) has been the subject of extensive technology maturation in preparation for flight system development. Part of the technology maturation effort included experimental evaluation of the TDU-1 thruster with conducting and dielectric front pole cover materials in two different electrical configurations. A graphite front magnetic pole cover thruster configuration with the thruster body electrically tied to cathode, and an alumina front pole cover thruster configuration with the thruster body floating were evaluated. Both configurations were also evaluated at different facility background pressure conditions to evaluate background pressure effects on thruster operation. Performance characterization tests found that higher thruster performance was attained with the graphite front pole cover configuration with the thruster electrically tied to cathode. A total thrust efficiency of 68% and a total specific impulse of 2,820 s was demonstrated at a discharge voltage of 600 V and a discharge power of 12.5 kW. Thruster stability regimes were characterized with respect to the thruster discharge current oscillations and with maps of the discharge current-voltage-magnetic field (IVB). Analysis of TDU-1 discharge current waveforms found that lower normalized discharge current peak-to-peak and root mean square magnitudes were attained when the thruster was electrically floated with alumina front pole covers. Background pressure effects characterization tests indicated that the thruster performance and stability were mostly invariant to changes in the facility background pressure for vacuum chamber pressure below 1×10-5 Torr-Xe (for thruster flow rates of 20.5 mg/s). Power spectral density analysis of the discharge current waveforms showed that increasing the vacuum chamber background pressure resulted in a higher discharge current dominant breathing mode frequency. Finally, IVB maps of the TDU-1 thruster indicated that the discharge current became more oscillatory with higher discharge current peak-to-peak and RMS values with increased facility background pressure at lower thruster mass flow rates; thruster operation at higher flow rates resulted in less change to the thruster's IVB characteristics with elevated background pressure.
Many contemporary Advanced Air Mobility (AAM), and more specifically, urban air mobility (UAM) vehicle designers are attracted to variable rotor speed-controlled designs with multiple rotors because of the great potential for mass savings compared to more traditional, variable blade pitch-controlled vehicles. These designs are based on the assumption that the stability and control of recreation or basic utility-sized drones can be scaled to larger passenger-sized vehicles. Previous work had shown the challenges in stabilizing passenger-sized quadcopters. In this study, power constraints were made less restrictive and varied, allowing more control power. Motor parameters such as efficiency, nominal voltage and current operating point, and rise time of the rotor speed controller step response were studied. By fixing the efficiency of the motor to 95% and assuming a motor voltage to current ratio of 2.0 (previously, assumed to be 1.0), the authors were able to stabilize the quadcopter in the roll axis because this allowed the vehicle to achieve adequate rise times between 0.4 and 0.8 s. This motor optimization was extended to a hexacopter and octocopter designed to the same payload size and mission as the quadcopter. The three vehicle configurations and their motor speed controllers were compared. It was found that while hexacopter and octocopter required more mass and overall power; all three configurations had similar margins required for control. However, the hexacopter and octocopter were able to use this power margin to achieve lower rise times (i.e. the vehicle responded more quickly to pilot inputs) than the quadcopter, with the octocopter having the lowest rotor response rise time of the three vehicle configurations studied.
An externally configured thermionic converter was operated for 200 h. The converter was disassembled and examined to determine internal changes as a result of operation. The metal/ceramic seals and all joints were unaffected by operation. Converter output voltage and operational time were sufficient to produce electrolysis of stabilized zirconia spacers used in the converter. Surface analysis of the electrode surfaces indicated the presence on the tungsten emitter of only oxygen, carbon, and silicon. The niobium collector was, however, 25 to 40% covered with other elements. This coverage represented all elements present within the converter as construction materials other than silicon and tungsten, which were not detected on the collector, and carbon, which was detected only in small amounts.
An electrical RF signal amplifier for providing high temperature stability and RF isolation and comprised of an integrated circuit voltage regulator, a single transistor, and an integrated circuit operational amplifier mounted on a circuit board such that passive circuit elements are located on side of the circuit board while the active circuit elements are located on the other side is described. The active circuit elements are embedded in a common heat sink so that a common temperature reference is provided for changes in ambient temperature. The single transistor and operational amplifier are connected together to form a feedback amplifier powered from the voltage regulator with transistor implementing primarily the desired signal gain while the operational amplifier implements signal isolation. Further RF isolation is provided by the voltage regulator which inhibits cross-talk from other like amplifiers powered from a common power supply. Input and output terminals consisting of coaxial connectors are located on the sides of a housing in which all the circuit components and heat sink are located.
The authors have developed a bolometer readout circuit which greatly improves the low-frequency stability of bolometric detectors. The circuit uses an ac bias voltage and two matched bolometers and allows stable dc bolometer operation for integration times greater than 10 s. In astronomical applications the readout allows for qualitatively different observation modes (e.g. staring or slow-drift scanning) which are particularly well suited for space observations and for the use of arrays. In many applications the readout can increase sensitivity. The authors present noise spectra for 4He temperature bolometers with no excess noise at frequencies greater than 0.1 Hz. The measured optical responsivity of a bolometer operated with the present readout is the same as that of a bolometer operated with a conventional readout.
AlGaAs diode lasers were used to injection seed a pulsed Q-switched alexandrite laser which produces a narrowband of radiation. Injection seeding is a method for achieving linewidths of less than 500 mega-Hz in the output of the broadband, tunable solid state laser. When the laser was set at a current of 59.8 milli-A and a temperature of 14.04 C, the wavelength was 767.6 nano-m. The Q-switched alexandrite laser was injection seeded and frequency stabilization was studied. The linewidth requirement was met, but the stability requirement was not due to drifting in the feedback voltage. Improvements on injection seeding should focus on increasing the feedback voltage to the laser diode, filtering the laser diode by using temperature controlled narrowband filters, and the use of diamond (SiC) grating placed inside the alexandrite laser's resonator cavity.
Compared to the conventional Ni-Co oxides (with or without AI additions), the NMC (1/3:1/3:1/3) cathode provides marginal improvement in specific capacity. However, some of the formulations based on the solid solutions of layered Li2Mn03 and LiM02 (M = Mn0.5Ni0.5} have shown capacities as high as 250 mAh/g, combined with high cell voltages (4.5 V) and with the likelihood of enhanced thermal stability. Multi-component electrolytes with low EC-proportions and selected co-solvents provide significant improvement in the low temperature performance, down to -60 C, combined with the non-flammable attribute from the co-solvents. The NMC cathode shows good compatibility with the carbonate-based low temperature electrolytes. Impressive performances have been realized at low temperatures of <= 30 C. Electrolytes with high salt concentration and high EC content fare well at room temperatures, while the formulations with low EC content and low salt concentration are preferred at low temperatures. DPA studies reveal increased SEI growth on the electrodes, especially anode, upon irradiation. Performance of low temperature electrolytes in prototype cells corroborate the findings from laboratory cells.
This paper discusses the results of an experimental study of the electrical aspects of carbon dioxide electrolysis using a ceramic electrolyte. The electrolyte compositions used in this study are 8% Y2O3 stabilized ZrO2, 7.5% CaO stabilized ZrO2, and 5% Y2O3 stabilized ThO2. Results indicate that the 8% Y2O3 stabilized ZrO2 is the best material to use for electrolysis, in terms of current as a function of voltage and temperature, and in terms of efficiency of oxide ion flow through it. The poorest results were obtained with the 5% Y2O3 stabilized ThO2 composition. An electrolysis system which might be employed to reclaim oxygen and carbon from effluents of space manufacturing, assuming that an industry would have to electrolyze 258,000 tonnes of CO2 per year, is predicted to require a total cell area of 110,000 sq m of 1 mm thickness and electrical capacity of 441 MW.
A voltage controlled phase shifter is rendered substantially harmonic distortion free over a large dynamic input range by employing two oppositely poled, equally biased varactor diodes as the voltage controlled elements which adjust the phase shift. Control voltages which affect the bias of both diodes equally are used to adjust the phase shift without increasing distortion. A feedback stabilized phase shifter is rendered substantially frequency independent by employing a phase detector to control the phase shift of the voltage controlled phase shifter.
Perovskite quantum dots (PQDs) have many properties that make them attractive for optoelectronic applications, including expanded compositional tunability and crystallographic stabilization. While they have not achieved the same photovoltaic (PV) efficiencies of top-performing perovskite thin films, they do reproducibly show high open circuit voltage (VOC) in comparison. Further understanding of the VOC attainable in PQDs as a function of surface passivation, contact layers, and PQD composition will further progress the field and may lend useful lessons for non-QD perovskite solar cells. Here, we use photoluminescence-based spectroscopic techniques to understand and identify the governing physics of the VOC in CsPbI3 PQDs. In particular, we probe the effect of the ligand exchange and contact interfaces on the VOC and free charge carrier concentration. The free charge carrier concentration is orders of magnitude higher than in typical perovskite thin films and could be tunable through ligand chemistry. Tuning the PQD A-site cation composition via replacement of Cs+ with FA+ maintains the background carrier concentration but reduces the trap density by up to a factor of 40, reducing the VOC deficit. These results dictate how to improve PQD optoelectronic properties and PV device performance and explain the reduced interfacial recombination observed by coupling PQDs with thin-film perovskites for a hybrid absorber layer.
This paper reports on a tungsten-oxide-based, nonvolatile, electrically reprogrammable, variable resistance device as an analog synaptic memory connection for electronic neural networks. A voltage controlled, reversible injection of H(+) ions in electrochromic thin films of WO3 is utilized to modulate its resistance. A hygroscopic thin film of Cr2O3 is the source of H(+) ions. The resistance of the device can be tailored and stabilized over a wide dynamic range (about 4 orders of magnitude), and the programming speed is modulated by the control voltage. The suitability of such a device in terms of its response speed, reversibility, stability, and cyclability for its use in electronic neural networks is discussed.
Discussion of the properties of both the stationary and portable magnetometers used in the Apollo program to measure static and dynamic fields on the lunar surface. A stationary magnetometer is described in which the three orthogonal vector components of the magnetic field are measured by three fluxgate sensors which are located at the ends of three orthogonal booms and contain ferromagnetic cores driven to saturation by means of a periodic current. In the Apollo 16 magnetometer special high-stability ring-core sensors were used which provided an output voltage to the analog-to-digital converter which is proportional to the magnetic field. A portable magnetometer is described which consists of a set of three orthogonal fluxgate sensors mounted on top of a tripod connected to an electronics box by a ribbon cable. The above-mentioned stationary magnetometer simultaneously measured the time-varying components of the field which were later subtracted from the portable magnetometer measurements to give the desired resultant steady field values caused by the magnetized crustal material.
With the intent of improving the safety characteristics of lithium ion cells, electrolytes containing flame retardant additives have been investigated. A number of triphenyl phosphate-containing electrolytes were evaluated in both coin cells and experimental three electrode lithium-ion cells (containing reference electrodes). A number of chemistries were investigated, including MCMB carbon/LiNi(0.8)Co(0.2)O2 (NCO), graphite/LiNi(0.8)Co(0.15)Al(0.05)O2 (NCA), Li/Li(Li(0.17)Ni(0.25)Mn(0.58))O2, Li/LiNiMnCoO2 (NMC) and graphite/LiNiMnCoO2 (NMC), to study the effect that different electrolyte compositions have upon performance. A wide range of TPP-containing electrolytes were demonstrated to have good compatibility with the C/NCO, C/NCA, and Li/NMC systems, however, poor performance was initially observed with the high voltage C/NMC system. This necessitated the development of improved electrolytes with stabilizing additives, leading to formulations containing lithium bis(oxalato)borate (LiBOB) that displayed substantially improved performance.
The definition of pulse modulated carrier frequency stability and timing jitter as well as the configuration and synchronous acquisition measurement method of its measurement system. Frequency stability of the pulse modulated carrier is measured with a discrimination technique. The pulse modulated carrier under testing is mixed with a reference frequency synthesizer. A delay line is used to convert the frequency fluctuation mixed IF signal to the voltage fluctuation. The system has the capability to make the phase noise measurement of two port devices on a pulsed carrier using a phase bridge. The noise voltage mentioned above is applied to the data acquisition and processing unit by PC to realize stability measurement. The data acquisition is in the form of pulse synchronization so that the measurement system accuracy is increased. The pulse width is more than 0.3 microseconds. The phase fluctuation variance, sigma, is less than 0.017. The time interval measuring system with high resolution is used to make interpulse timing and pulse width jitters automatic measurement. The pulse width is less than 0.2 ns. The resolution is 0.1 ns. The system is successfully applied to radar measurement.