American-Made Geothermal Geophone Prize: Ultra-High Temperature Seismic Tool for Geothermal Wells Summary Report

This work was conducted in support of the American Made Geothermal Prize. The following data summary report presents the testing conducted at Sandia National Labs to validate the performance of the Ultra-High Temperature Seismic Tool for Geothermal Wells. The goal of the testing was to measure the sensitivity of the device to seismic vibrations and reliability of the instrument at elevated temperatures. To this end, two tests were conducted: 1) Ambient Temperature Seismic Testing, which measured the response of the tool to a sweep of frequencies from 1 to 1000 Hz, and 2) Elevated Temperature Survivability Testing which measured the voltage response of the device at 225°C over a month-long testing window. The details of the testing methodology and summary of the tests are presented herein.

15 GEOTHERMAL ENERGY↗

Multichannel deconvolution of vibrational signals: A state-space inverse filtering approach

Deconvolution of noisy measurements, especially when they are multichannel, has always been a challenging problem. The processing techniques developed range from simple Fourier methods to more sophisticated model-based parametric methodologies based on the underlying acoustics of the problem at hand. Methods relying on multichannel mean-squared error processors (Wiener filters) have evolved over long periods from the seminal efforts in seismic processing. However, when more is known about the acoustics, then model-based state-space techniques incorporating the underlying process physics can improve the processing significantly. The problems of interest are the vibrational response of tightly coupled acoustic test objects excited by an out-of-the-ordinary transient, potentially impairing their operational performance. Further, employing a multiple input/multiple output structural model of the test objects under investigation enables the development of an inverse filter by applying subspace identification techniques during initial calibration measurements. Feasibility applications based on a mass transport experiment and test object calibration test demonstrate the ability of the processor to extract the excitations successfully.

42 ENGINEERING↗

Pipeline Monitoring Using Highly Sensitive Vibration Sensor Based on Fiber Ring Cavity Laser

A vibration fiber sensor based on a fiber ring cavity laser and an interferometer based single-mode-multimode-single-mode (SMS) fiber structure is proposed and experimentally demonstrated. The SMS fiber sensor is positioned within the laser cavity, where the ring laser lasing wavelength can be swept to an optimized wavelength using a simple fiber loop design. To obtain a better signal-to-noise ratio, the ring laser lasing wavelength is tuned to the maximum gain region biasing point of the SMS transmission spectrum. A wide range of vibration frequencies from 10 Hz to 400 kHz are experimentally demonstrated. In addition, the proposed highly sensitive vibration sensor system was deployed in a field-test scenario for pipeline acoustic emission monitoring. An SMS fiber sensor is mounted on an 18” diameter pipeline, and vibrations were induced at different locations using a piezoelectric transducer. The proposed method was shown to be capable of real-time pipeline vibration monitoring.

47 OTHER INSTRUMENTATION↗

Process damping identification using Bayesian learning and time domain simulation

Process damping can provide improved machining productivity by increasing the stability limit at low spindle speeds. However, existing methods for identifying process damping models experimentally require specialized setups and/or multiple cutting tests. While the phenomenon is well known, the modeling challenges limit pre-process parameter selection that leverages the potential increases in material removal rates. This paper proposes a physics-informed Bayesian method that can identify the cutting force and process damping models from a limited set of test cuts without requiring direct measurements of cutting force or vibration. The method uses time domain simulation to incorporate process damping and provide a basis for test selection. Here, new strategies for efficient sampling and dimensionality reduction are applied to lower computation time and minimize the effect of model error. The proposed method is demonstrated and the identified cutting and damping force coefficients are compared to values obtained using machining tests and least-squares fitting.

42 ENGINEERING↗

Recent Radioactive Material Package Testing Experiences at Oak Ridge National Laboratory

Oak Ridge National Laboratory (ORNL) was a pioneer in the testing of radioactive material shipping packages and has been performing such tests for over 50 years. Currently, except for Type B thermal tests, testing is performed at the purpose-built Packaging Research Facility that is located at the National Transportation Research Center - a U.S. Department of Energy User Facility. Packages used for the transportation of Type B quantities of radioactive materials must be capable of meeting normal conditions of transportation (NCT) requirements and hypothetical accident conditions (HAC) requirements as defined in Title 10 Code of Federal Regulations (CFR) Part 71. Evaluation of package designs to these criteria typically involves a combination of analysis and physical testing. Required physical tests include free drop, crush, puncture, penetration, compression, vibration, water spray, water immersion, and thermal. The Oak Ridge National Laboratory (ORNL) Packaging Evaluation Facility (PEF) at the National Transportation Research Center (NTRC) provides an inclusive testing capability for a wide variety of packages needed for shipment of radioactive materials. Since PATRAM 2019, ORNL has performed several sets of tests including testing of two designs of the Defense Program Package (DPP-3 and DPP-1) and several Special Form Capsules. This paper provides an overview of the testing performed as well as a summary of advancements made to the ORNL package testing program during that time.

Martinez, Oscar↗

MECHANICAL SHOCK AND VIBRATION ANALYSIS OF SPENT NUCLEAR FUEL CARRIED BY THE ATLAS RAILCAR

Researchers at Pacific Northwest National Laboratory have completed a structural-dynamic analysis of spent nuclear fuel subjected to the mechanical shock and vibration environment that is anticipated during normal conditions of transport in casks carried by the Atlas railcar. The Atlas railcar is a new railcar design that is being developed specifically for the purpose of carrying spent nuclear fuel casks. The analysis used best-estimate railcar dynamics models of the Atlas railcar and considered 17 different spent nuclear fuel transportation cask systems, representing the current fleet of cask options. This work used NUCARS, a specialized railcar dynamics explicit finite element code to calculate railcar dynamic response to prescribed speeds and track configurations. The railcar dynamics models provided cask transient motion for a wide range of speeds and track conditions, generating a relatively large database of potential cask motion. All of the cask motion transients were then applied as loading conditions to LS-DYNA structural-dynamic models of a single fuel rod. The analyses predict that the Equipos Nucleares S.A./U.S. Department of Energy (ENSA/DOE) multimodal transportation test of 2017 provided a relatively stronger vibration environment than is expected from the Atlas railcar. This paper describes the analysis methods, the analysis results, and compares the results of the Atlas transportation analysis to the test results and analyses of the ENSA/DOE multimodal transportation test of 2017.

Klymyshyn, Nicholas A.↗

Studying Open Quantum Systems Relevant to Chemistry on a Trapped-Ion Quantum Simulator (Final Technical Report)

This project advances the trapped-ion quantum simulator as a versatile platform for studying open quantum system phenomena. We aim to contribute to the emerging quantum simulation toolkits and enable simulation of nanoscale energy processes. Trapped-ion platforms offer unique capabilities: their vibrational motion can be precisely manipulated, measured, and coherently coupled to auxiliary qubits. The vibrational mode can function both as a highly sensitive quantum sensor and a programmable environment bath. Using this platform, we achieved three major outcomes. First, we demonstrated using the vibrational mode as an ultrasensitive probe for testing fundamental physics, including possible nonlinear quantum mechanics effects. Second, we established that these modes can act as controllable baths in which tunable noise and loss can enhance or modify energy-transfer dynamics, providing the experimental preparation toward studying mechanisms relevant to chemical reactions and light-harvesting systems. Third, by introducing controllable nonlinear gain and loss, we showed theoretically how simulations using trapped ions can model vibrationally-assisted energy transport in a non‐Hermitian quantum system comprising a chromophore dimer weakly coupled to a vibrational mode. Exploring the non‐Hermitian dynamics of the whole system including vibrations, we found that energy transfer accompanied by absorption of phonons from a vibrational mode can be significantly enhanced near an exceptional point. This theoretical work on simulation of energy transfer processes in driven non‐Hermitian quantum systems revealed an interesting novel path to study open quantum systems dynamics under conditions of gain and loss. We then further explored the benefits of controllable gain and loss with an experimental realization of quantum analogs of nonlinear oscillators, namely, the van der Pol oscillator. Here we observed mutual synchronization mediated by collective dissipation between two oscillators. In parallel, we explored related quantum networking protocols using the same trapped-ion platform, developing fast, high-fidelity schemes for distributing entanglement. Together, these achievements show that trapped-ion vibrational modes provide a highly programmable and high-fidelity platform for investigating complex dissipative quantum behavior, while enabling new approaches to remote quantum sensing, energy science, and nonlinear quantum dynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Vibrational processing of a dynamic structural flight system: A multichannel spectral estimation approach

Dynamic testing of large flight vehicles (rockets) is not only complex, but also can be very costly. These flights are infrequent and can lead to disastrous effects if something were to fail during the flight. The development of sensors coupled to internal components offers a great challenge in reducing their size, yet still maintaining their precision. Sounding rockets provide both a viable and convenient alternative to the more costly vehicular flights. Some of the major objectives are to test various types of sensors for monitoring components of high interest as well as investigating real-time processing techniques. Signal processing presents an extreme challenge in this noisy multichannel environment. The estimation and tracking of modal frequencies from vibrating structures is an important set of features that can provide information about the components under test; therefore, high resolution multichannel spectral processing is required. Finally, the application of both single channel and multichannel techniques capable of producing reliable modal frequency estimates of a vibrating structure from uncertain accelerometer measurements is discussed.

42 ENGINEERING↗

Harvesting Subsea Water Motion to Provide Clean Electrical Power

This TEAMER project had three main objectives related to characterizing the performance of a vortex-induced vibration (VIV) marine energy harvesting device called the Whatever Input To Torsion (WITT). The first was to characterize the motion of the WITT device as it vibrates on top of a pipe in a natural tidal flow. The second was to measure how much electricity the WITT device generates when it is deployed on top of a pipe that is secured to the seabed with a lander. The third objective was to measure how much electricity the WITT device generates in the same configuration but with a longer pipe. This TEAMER project succeeded in satisfying the first objective by measuring the motion of the WITT device with an inertial measurement unit (IMU) mounted in the WITT housing. The motion was described by examining changes in the acceleration, pitch, roll, and yaw, and displacement. The frequency of the motion was characterized using spectral analysis. The TEAMER project succeeded in reaching the second objective by measuring the power produced by the WITT. It is reported here as the average and maximum power in hourly intervals. WITT Energy decided to not have us pursue the third objective of testing a longer pipe because the first test was unexpectedly successful at having the system vibrate at the target frequency. A longer pipe would have resulted in a decreased frequency and therefore not have been a useful test. Based on these findings, the decision was made to keep the same pipe length for both tests and improve on other aspects of the test structure that had failed during the first test. The key finding of this TEAMER project is that the WITT is capable of generating electricity in moderate flow speeds when it is in a housing that is attached to a 2.5 m pipe and secured to the seabed by a lander. This report contains the first power values for a VIV instrument that generates electricity from a pendulum swinging at the top of a long pipe. The experiment demonstrated that the vibration frequency of the device varied with the tidal current speed, which changed throughout a given tidal cycle. This meant that the desired peak frequency was not sustained for more than one hour. The success of this TEAMER test provides evidence that continued research in the area of electricity generation from VIV holds promise as a source of marine energy for offshore applications. Future tests should focus on refining the pipe length equations and improving the power take off system of the WITT power electronics. In addition, experiments aimed at expanded testing and evaluation (e.g. longer than one month) are needed to measure the power production at higher tidal current speeds and test the system's durability.

Branch, Ruth A. (ORCID:0000000202356719)↗

Flow Induced Vibration Studies in Pressurized Helium Gas Cooling Channels

Production of metastable Technetium-99 (Tc-99m), a radioactive tracer that emits gamma rays, is vital to the medical imaging community. Tc-99m is extracted from the decay of Molybdenum-99 (Mo-99) which has a half-life of about 2-3 days. The work presented in this report is part of the NNSA’s mission to produce Mo-99 commercially, within the US, without the use of highly enriched uranium (HEU) in support of nonproliferation and global security. Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 through the irradiation of Mo-100 targets using an electron beam. The NMR target comprises a stack of approximately 60-70 Mo-100 disks with diameter 24 mm and thickness 0.74 mm held in stainless steel laminations, each separated using 0.25 mm thick stainless steel spacers. The symmetric target stack is housed in an Inconel vessel with two Inconel windows on either side. Two electron accelerators are used to produce 40 MeV, 3.16 µA electron beams each that penetrate the Inconel windows and irradiate the Mo-100 disks. Approximately 90% of the total 250 kW beam power is deposited in the NMR target during the irradiation process. During irradiation, pressurized helium gas flows through 0.25 mm thin gaps between the disks cooling the beam window, target disks, disk laminations and spacers. Both NMR and LANL have found during cold testing of the target system (no heat deposition) that the Mo-100 disks undergo significant mass loss and disk breakage due to vibrations induced by the flowing helium gas. The mass loss is not only undesirable due to monetary loss from reduced final quantities of Mo-99, but also due to the hazards associated with radioactive material trapped in the cooling lines and particle filters. The effect of flow rate and target geometry on the flow induced vibrations need to be quantified, and recommendations provided to minimize this mass loss. This work describes LANL’s experimental characterization of the flow induced vibrations and disk mass loss in a reduced scale set-up containing 10 Mo-100 disks. We use high speed imaging, displacement measurements and microphone measurements combined with signal processing to estimate the vibration frequency of each disk. The effect of disk thickness, target fit and duration of testing on the mass loss is described. We find that in the current configuration of NMR targets, the vibrations and mass loss on the first disk are minimized, while those in the adjacent disks are highest. The microphone and high-speed image data show that increased flow rates and increased duration of testing increases vibration frequency and mass loss. The mass loss is due to both disk rotation and back and forth motion. There are visible wear marks on the disks with the highest mass loss. We also note that the current NMR window gap reduces flow induced vibrations compared to the previous smaller gaps. Longer duration testing will provide more data and verification for the findings presented in this report. The work will be continued in FY 24.

43 PARTICLE ACCELERATORS↗

Laboratory Drilling Test Data of PDC bits with Sierra White Granite Rock

This file contains unprocessed drilling data tests on Sierra White Granite (SWG) using two new PDC bits. The tests were conducted at Sandia National Laboratories (SNL) in the Hard Rock Drilling Facility (HRDF). The collected data includes ROP data at rotational speeds of 80, 120, and 160 RPMs, with incremental weight on bit (WOB) up to 5100 lbs. The diameter of the 4-bladed and 5-bladed PDC bits was 3 3/4" and supplied by National Oilwell Varco (NOV). Five tests modes were conducted for both bits, which are as follow: (1) Rigid configuration, with no vibration compliance (2) Flywheel configuration (3) Torsional compliance configuration (4) Axial Compliance configuration (5) Combined Axial and Torsional compliance configuration Note: the WOB and torque in the drilling data should be calibrated by zeroing the WOB and torque when the drill bit tags the rock sample.

15 GEOTHERMAL ENERGY↗

Sensor Selection for MIMO Vibration [Slides]

Objectives: Introduce a sensor selection approach to assist test engineers with MIMO test design. Demonstrate the capability of the approach. Approach: Define a desired response from a field model. Supply the sensor selection technique to two lab models, with different boundary conditions than the “field” model. Compare the laboratory response to the field response using sensors selected from the approach.

42 ENGINEERING↗

Sensor Selection for MIMO Vibration: Summary Slides [Slides]

Summary: Sensor selection approach for MIMO testing was defined and demonstrated on a model of a practical system. Laboratory response obtained using the approach matched the field response well. Information about how many control sensors, and where to locate sensors can be gleaned from the approach.

42 ENGINEERING↗

A high efficiency and low vibration liquid nitrogen cooling system for silicon crystal based x-ray optics

A compact low-cost cryocooling system has been designed, constructed, and tested at SLAC National Accelerator Laboratory. The cooling power is provided by natural convection and phase change of the liquid nitrogen. The initial application was to cool silicon crystal optics to the sub-100 K range. A silicon crystal of dimension (width × depth × height) 50 × 50 × 30 mm3 has been used with an electric heater on the top surface in this prototyping test. This system can effectively provide more than 80 W of cooling power to the optics with a consumption of liquid nitrogen less than 2.1 l/h. The vibration of the silicon crystal was monitored during the tests with added electric heater power on the crystal. We note the vibration of the silicon crystal due to liquid nitrogen boiling is negligible.

47 OTHER INSTRUMENTATION↗

Module-Level Thermal Interface Material Degradation in HALT

Abstract In this study, thermal interface material (TIM) degradation is driven through highly accelerated life test (HALT) using temperature cycling with a prescribed vibrational acceleration for two commercially available materials having thermal conductivities of 6.0 and 8.5 W/m K. HALT specimens were prepared by applying TIM through a 4-mil stencil over AlSiC baseplates in the shape of those used in Wolfspeed CAS325M12HM2 power electronics modules. Baseplates were mounted onto aluminum carrier blocks with embedded thermocouples to characterize the thermal resistance across the baseplate and TIM layer. Thermal dissipation into the top of the baseplates was provided by a custom heating block, which mimics the size and placement of the die junctions in CAS325 modules, applying power loads of 200, 300, and 400 W. After initial characterization, samples were transferred to the HALT chamber with one set of samples exposed to temperature cycling only (TCO) and the other temperature cycling and vibration (TCV). Both sample sets were cycled between temperature extremes of −40 °C and 180 °C with vibrations applied at a peak acceleration of 3.21 Grms. After hundreds of cycles, samples were reevaluated to assess changes in thermal resistance to provide an accelerated measure of TIM degradation. This allows for reliability prediction of useful lifetime (illustrated in a solar inverter case study herein), as well as to provide a basis for developing an accelerated testing method to related temperature cycling to faster methods of degradation. Such techniques provide a means to develop maintenance schedules for power modules for ensuring sufficient thermal performance over the operating lifetime.

Engineering↗

Small-sized specimen design with the provision for high-frequency bending-fatigue testing

The testing and study of emerging materials—such as additively manufactured materials—demands for specimen designs that are cost effective and time saving. Here the design of a small-sized bending-fatigue test specimen for an ultrasonic fatigue testing system is reported in this paper. The design is optimized based on the finite element analysis and analytical-solution results to achieve the proper vibration shape and stress distribution. The proposed design is evaluated in the high- and very-high-cycle fatigue regimes under 20-kHz frequency. Both simulation and testing results confirm that the desirable vibration mode occurs and the specimen fails at the designated test (gauge) section, where the maximum stress exists. The stress–life (S–N) curve is obtained for Inconel alloy 718 and indicates an expected trend.

36 MATERIALS SCIENCE↗

Laser Measurements and Modeling of Shock Tunnel Freestream Velocity and Multispecies Thermal Nonequilibrium

Coherent anti-Stokes Raman scattering (CARS) and nitric oxide molecular tagging velocimetry (NO-MTV) were used to characterize the freestream in Sandia’s Hypersonic Shock Tunnel (HST) using a burst-mode laser operated at 100 kHz. Experiments were performed at nominal freestream velocities of 3 and 4 km/s using both air and N 2 test gas. The CARS diagnostic provides nonequilibrium characterization of the flow by measuring vibrational and rotational temperatures of N 2 and O 2 , which are compared to NO temperatures from separate laser absorption experiments. Simultaneous, collinear freestream velocities were measured using NO MTV along with pitot pressure measurements. Furthermore, this extensive freestream dataset is compared to nonequilibrium CFD that is capable of modeling species-specific, vibrational temperatures throughout the nozzle expansion. Significant nonequilibrium between vibrational and rotational temperatures was measured at each flow condition. N 2 exhibits the most nonequilibrium, followed by O 2 and NO. The CFD model captures this trend, although it consistently overpredicts N 2 and O 2 vibrational temperatures. At 3 km/s, the modeled NO nonequilibrium is underpredicted, whereas it is overpredicted at 4 km/s. Good agreement is seen between CFD and the velocity and rotational temperature measurements. Experiments with water added to the test gas yielded no discernable difference in vibrational relaxation.

Aerodynamics↗

Multi-Axis Resonant Plate Shock Testing Evaluation and Test Specification Development

Resonant plate testing is a shock test method that is frequently used to simulate pyroshock events in the laboratory. Recently, it was discovered that if the unit under test is installed at an off-center location, a tri-axial accelerometer would record a shock response in three directions and the resulting shock response spectra implied that the test may have qualified the component in three directions simultaneously. The purpose of this research project was to evaluate this idea of multi-axis shock testing to determine if it was truly a multi-axis shock environment and if such a test could be used as an equivalent component qualification test. A study was conducted using generic, additively manufactured components tested on a resonant plate, along with an investigation of plate motion to evaluate the component response to off- center plate excitation. The data obtained here along with the analytical simulations performed indicate that off-center resonant plate tests are actually not three-axis shock tests, but rather single axis shocks at an arbitrary angle dictated by the location of the unit under test on the plate. This conclusion is supported by the fact that only one vectored shock input is provided to the component in a resonant plate test. Thus, the output response is a coupled response of the transverse plate vibration and the rotational motion of the component on the plate. Additionally, a multi-axis shock test defined by three single axis test environments always results in a significant component over-test in one direction.

42 ENGINEERING↗