Studies of Alternative Ventilation Configurations to Mitigate Airborne Exposure Risks in Office Spaces

The objective of this study was to evaluate the impact of alternative ventilation configurations on airflow patterns and potential exposure risks in office spaces. Two existing conference rooms at Sandia NM were modeled using Computational Fluid Dynamics (CFD) simulations to characterize airflow patterns and potential airborne exposure risks in well-mixed and once-through (through-flow) ventilation conditions. Multiple scenarios were studied to evaluate the impact of occupancy, Plexiglass barriers, and a modified-return airflow configuration. Experimental and visualization tests were also conducted to validate the well-mixed and through-flow models and findings. The simulations demonstrated that the modified-return airflow configuration that promoted through-flow conditions reduced pathogen concentrations within the space compared to the well-mixed airflow configuration; occupancy reduction only reduced the number of exposed individuals, and Plexiglass barriers had almost no effect. The experimentally measured air speeds at nine anemometer locations generally matched the simulated airflow velocities, and a fog-purge visualization test was also consistent with simulated results of plume movement and dissipation. The visualization tests demonstrated improvements in air change rate with the modified return, which promoted through-flow conditions, versus the original well-mixed ventilation configuration. The results of this study demonstrate that minor modifications to a space that promote through-flow conditions can improve air quality and reduce pathogen concentrations. Additional airflow modeling and testing of alternative occupied space configurations are recommended to further inform room designs that mitigate airborne exposure risks for occupants.

42 ENGINEERING↗

Ventilation: Fume Hoods Self-Study Course # 48002

This course presents an overview of the requirements and safe work practices for the use of engineered ventilation controls (EVCs) at Los Alamos National Laboratory (LANL). EVCs addressed in this manual include fume hoods, local exhaust ventilation (LEV) systems other than fume hoods, portable and in-place high-efficiency particulate air (HEPA) filtration systems. Requirements from LANL Procedure P101-16, Industrial Ventilation (non-HVACR) that address EVC certification and use, along with responsibilities of workers who use EVCs and the responsible line managers (RLMs) of such workers, are also presented. Per 101-16, 6.1, workers who use, maintain, or certify (i.e., inspect and test) fume hoods, or Persons in Charge (PICs) who oversee others in those tasks, must complete this course.

42 ENGINEERING↗

The effect of gas diffusion on the flow coefficient for a ventilated cavity

The results of an experimental investigation into the effect of gas diffusion on the volume flow-rate of gas needed to sustain a ventilated cavity are presented. Gas diffusion was found to have a significant effect on the ventilated flow rate required to sustain a cavity of a given size. An analysis for the gas diffusion effect was conducted based on a mathematical model of diffusion proposed by Brennen. The results compare favorably with experimental data. Also, an empirical scaling relationship is proposed for ventilated cavity flows.

Billet, M. L.↗

Protective garment ventilation system

A method and apparatus for ventilating a protective garment, space suit system, and/or pressure suits to maintain a comfortable and nontoxic atmosphere within is described. The direction of flow of a ventilating and purging gas in portions of the garment may be reversed in order to compensate for changes in environment and activity of the wearer. The entire flow of the ventilating gas can also be directed first to the helmet associated with the garment.

Lang, R.↗

Distribution of pulmonary ventilation and perfusion during short periods of weightlessness

Airborne experiments were conducted on four trained normal male subjects (28-40 yr) to study pulmonary function during short periods (22-27 sec) of zero gravity obtained by flying a jet aircraft through appropriate parabolic trajectories. The cabin was always pressurized to a sea-level altitude. The discussion is limited to pulmonary ventilation and perfusion. The results clearly demonstrate that gravity is the major factor causing nonuniformity in the topographical distribution of pulmonary ventilation. More importantly, the results suggest that virtually all the topographical nonuniformity of ventilation, blood flow, and lung volume observed under 1-G conditions are eliminated during short periods of zero gravity.

Michels, D. B.↗

Measurement of convective heat transfer to solid cylinders inside ventilated shrouds

The influence of ventilated cylindrical shrouds on the convective heat transfer to circular cylinders has been studied experimentally. Geometries studied were similar to those used in commercially available platinum resistance thermometers. Experiments showed that thermal response (convection) was enhanced when the shroud ventilation factor was approximately 20 percent (80 percent solid), and that maximum enhancement occurred when the ventilation holes were located symmetrically on either side of the stagnation lines.

Daryabeigi, K.↗

Ventilating Air-Conditioner

Air-conditioner provides ventilation designed to be used alone or incorporated into cooling or heating system operates efficiently only by recirculating stale air within building. Energy needed to operate overall ventilating cooling or heating system slightly greater than operating nonventilating cooling or heating system. Helps to preserve energy efficiency while satisfying need for increased forced ventilation to prevent accumulation of undesired gases like radon and formaldehyde. Provides fresh treated air to variety of confined spaces: hospital surgeries, laboratories, clean rooms, and printing shops and other places where solvents used. In mobile homes and portable classrooms, eliminates irritant chemicals exuded by carpets, panels, and other materials, ensuring healthy indoor environment for occupants.

Dinh, Khanh↗

Ventilation Transport Trade Study for Future Space Suit Life Support Systems

A new and advanced portable life support system (PLSS) for space suit surface exploration will require a durable, compact, and energy efficient system to transport the ventilation stream through the space suit. Current space suits used by NASA circulate the ventilation stream via a ball-bearing supported centrifugal fan. As NASA enters the design phase for the next generation PLSS, it is necessary to evaluate available technologies to determine what improvements can be made in mass, volume, power, and reliability for a ventilation transport system. Several air movement devices already designed for commercial, military, and space applications are optimized in these areas and could be adapted for EVA use. This paper summarizes the efforts to identify and compare the latest fan and bearing technologies to determine candidates for the next generation PLSS.

Kempf, Robert↗

Weather responsive smart ventilation system using multiple optimization parameters

A smart ventilation system which uses outdoor temperature and moisture to optimize control of the system. The main principle is to shift ventilation from time periods that have large indoor-outdoor temperature and moisture differences to periods when these differences are smaller, and their energy and comfort impacts are expected to be less. Fan flow rates are reduced when the outside temperature and moisture falls outside of optimum levels, yet overall air exchange is maintained to ensure chronic and acute exposure to pollutants remains relative to best practice. Online weather and smart thermostat data can be used as control inputs, so no specific measurement devices are needed to control ventilation fans.

Parker, Danny↗

Investigation of ventilation-coupled high energy density sensible thermal energy storage

Low-cost energy storage will play an important role in supporting the decarbonization of the energy sector. Here, a novel approach to thermal energy storage for buildings is proposed, in which a tank of antifreeze liquid can be used to heat outdoor air in mechanical ventilation systems. If heated to a high enough temperature, the fluid can potentially undergo temperature swings of nearly 100°C during discharge in cold climates. Because the energy density of sensible storage systems scales proportionally to the system temperature change, this concept has the potential to offer higher energy densities than other liquid-based sensible storage devices used in building applications. A one-dimensional numerical model of the storage system was developed and experimentally validated using 30 wt% (wt%) potassium acetate as an aqueous antifreeze solution. Using a commercial hot water tank, energy densities of 47.0 kW-hour per cubic meter (kWh/m 3 ) were demonstrated in a laboratory setting. Material energy densities of approximately 74.7 (kWh/m 3 ) were measured. Design improvements may boost this energy storage density even further. Because of the system's relative simplicity, ventilation-coupled sensible storage has the potential to be an easily deployable, low-cost energy storage solution for building systems.

25 ENERGY STORAGE↗

Modelling Airborne Transmission and Ventilation Impacts of a COVID-19 Outbreak in a Restaurant in Guangzhou, China

Computational fluid dynamics (CFD) modelling was performed to simulate spatial and temporal airborne pathogen concentrations during an observed COVID-19 outbreak in a restaurant in Guangzhou, China. The reported seating configuration, overlap durations, room ventilation, layout, and dimensions were modelled in the CFD simulations to determine relative exposures and probabilities of infection. Results showed that the trends in the simulated probabilities of infection were consistent with the observed rates of infection at each of the tables surrounding the index patient. Alternative configurations that investigated different boundary conditions and ventilation conditions were also simulated. Increasing the fresh-air percentage to 10%, 50%, and 100% of the supply air reduced the accumulated pathogen mass in the room by an average of ~30%, ~70%, and ~80%, respectively, over 73 min. Overall, the probability of infection was reduced by ~10%, 40%, and 50%, respectively.

60 APPLIED LIFE SCIENCES↗

End-Use Savings Shapes Measure Documentation: Demand Control Ventilation

This documentation focuses on a single end-use savings shape measure - Demand Control Ventilation (DCV). DCV can save energy by reducing the rate at which outdoor air (OA) is delivered during periods of less-than-design occupancy. This measure will enable DCV for air loops using applicable HVAC system types (all except dedicated outdoor air systems [DOAS], packaged systems, or that have an energy recovery ventilator [ERV]) and serving applicable space types (all except kitchens, dining areas, patient spaces, mechanical rooms, stairwells and corridors, or high exhaust space types) using model occupancy schedules to control the DCV. The measure is applicable to 72.7% of the stock floor area. As office buildings outside of California in ComStock are modeled using a single, whole-building space type, DCV is not applied to these building types. The DCV measure demonstrates 2.6% total site energy savings (119 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat Pumps and Energy Recovering Ventilators in Northern Alaska

The intended purpose of this project was to bring alternative heat and ventilation options to rural communities off the road system in Northwestern Alaska. Most of the residents of these communities are reliant upon kerosene or other fossil fuels to provide heat to their homes. Our intention was to offer an alternative to using those sources by providing heat pumps to 45 homes in the communities of Elim and Koyuk. When projecting energy use for these units based on the fuel prices at the time, it was discovered that energy costs for heat pumps would equal or slightly exceed the costs of existing kerosene units. Secondly, as part of our E&l grant we installed 45 energy recovery ventilators (ERV’s) in those same homes. This was important given our experience over the years with moisture and comfort issues in most homes within this region. Exhaust-only systems are rarely used due to the high heating costs. Additionally, exhaust-only systems have a potential risk of back drafting due to tight building construction. Balanced systems like this eliminate that risk while improving indoor air quality. Another benefit to these types of systems is the fact that they help transfer heat from a single heat source equally throughout the building. Our overall goal was to offer new technology options to improve these structures and the families that reside in them where, given their location and extreme seasonal temperature swings, they have historically never been offered.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Alveolar ventilation to perfusion heterogeneity and diffusion impairment in a mathematical model of gas exchange

This study describes a two-compartment model of pulmonary gas exchange in which alveolar ventilation to perfusion (VA/Q) heterogeneity and impairment of pulmonary diffusing capacity (D) are simultaneously taken into account. The mathematical model uses as input data measurements usually obtained in the lung function laboratory. It consists of two compartments and an anatomical shunt. Each compartment receives fractions of alveolar ventilation and blood flow. Mass balance equations and integration of Fick's law of diffusion are used to compute alveolar and blood O2 and CO2 values compatible with input O2 uptake and CO2 elimination. Two applications are presented. The first is a method to partition O2 and CO2 alveolar-arterial gradients into VA/Q and D components. The technique is evaluated in data of patients with chronic obstructive pulmonary disease (COPD). The second is a theoretical analysis of the effects of blood flow variation in alveolar and blood O2 partial pressures. The results show the importance of simultaneous consideration of D to estimate VA/Q heterogeneity in patients with diffusion impairment. This factor plays an increasing role in gas alveolar-arterial gradients as severity of COPD increases. Association of VA/Q heterogeneity and D may produce an increase of O2 arterial pressure with decreasing QT which would not be observed if only D were considered. We conclude that the presented computer model is a useful tool for description and interpretation of data from COPD patients and for performing theoretical analysis of variables involved in the gas exchange process.

NASA Discipline Environmental Health↗

Spacecraft Cabin Ventilation Fan Research at NASA

NASA has recently made the geometry and solid model for a spacecraft cabin ventilation fan prototype available to the public via electronic file downloads from the NASA Technical Report Server. This fan can be used for research and development by many organizations. The fan is 3.5 inches in diameter, 9 inches long, and weighed 3.6 lb. The NASA Quiet Space Fan was designed to make 3.64 inches of water pressure rise at 150.3 cfm of airflow at 12,000 rpm at standard air conditions of 70ºF and 14.7 psia. The performance of the metal version of the fan was measured to be 3.48 inches of water at 150.6 cfm at design speed. A low-noise blade-vane count was chosen to try to reduce tone noise generated by this fan by cutting off the first three blade passing frequency tones. In-duct microphone array measurements indicated that the most evident tones occur for frequencies of 1800 Hz (1 BPF) and 7200 Hz (4 BPF). Using reverberant room standard testing methods, the A-weighted sound power level for the fan operating at design point conditions was measured to be 71 dBA. This report describes the current set of publicly available information for this fan. The fan was designed, optimized, and tested with tools and techniques that NASA has traditionally used for turbofan engine research. This is one way that technology developed for aerospace applications can be used more broadly, since quiet and efficient fans are needed for many ventilation systems on spacecraft, aircraft, watercraft, land vehicles, and buildings.

fan, noise, ventilation↗

Spacecraft Cabin Ventilation Fan Research at NASA

NASA has recently made the geometry and solid model for a spacecraft cabin ventilation fan prototype available to the public via electronic file downloads from the NASA Technical Reports Server. This fan can be used for research and development by many organizations. The NASA Quiet Space Fan is 8.89 cm (3.50 in) in diameter, 22.9 cm (9.00 in) long, and the metal fan weighs 1.63 kg (3.6 lbm). The fan was designed to generate a system total pressure rise of 906 Pa (3.64 inches of water) at 0.709 m3/s (150.3 cfm) of airflow at 12,000 rpm (at 21.1ºC (70ºF) and 14.7 psia). Performance measured using standardized techniques showed good agreement with design and predicted values. A low-noise blade-vane count was chosen to reduce tonal noise generated by rotor-stator interaction for the first three blade passing frequency harmonics. In-duct microphone array measurements indicated that the most evident tones occur at frequencies of 1,800 Hz (1 BPF) and 7,200 Hz (4 BPF). Using reverberant room standard testing methods, the A-weighted sound power level for the fan operating at design point conditions was measured to be 71 dBA. This report describes the current set of publicly available information for this fan. The fan was designed, optimized, and tested with tools and techniques that NASA has traditionally used for turbofan engine research. This demonstrates that technology developed for aerospace applications can be used more broadly, since quiet and efficient fans are needed for many ventilation systems in spacecraft, aircraft, watercraft, land vehicles, and buildings.

fan↗