Benchmarking performance changes in the simulation of extratropical modes of variability across CMIP generations

In this work, we evaluate extratropical modes of variability in the three most recent phases of the Coupled Model Intercomparison Project (CMIP3, 5, and 6) to gauge improvement of climate models over time. A suite of high-level metrics is employed to objectively evaluate how well climate models simulate the qobserved Northern Annular Mode (NAM), North Atlantic Oscillation (NAO), Pacific North America pattern (PNA), Southern Annular Mode (SAM), Pacific Decadal Oscillation (PDO), North Pacific Oscillation (NPO), and North Pacific Gyre Oscillation (NPGO). We apply a Common Basis Function (CBF) approach that projects model anomalies onto observed empirical orthogonal functions (EOFs), together with the traditional EOF approach, to CMIP Historical and AMIP models. We find simulated spatial patterns of those modes have been significantly improved in the newer models, although the skill improvement is sensitive to the mode and season considered. We identify some potential contributions to the pattern improvement of certain modes (e.g., the Southern Hemisphere jet and High-top vertical coordinate), however the performance changes are likely attributed to gradual improvement of the base climate and multiple relevant processes. Less performance improvement is evident in the mode amplitude of these modes and systematic overestimation of the mode amplitude in spring remains in the newer climate models. We find that the post-dominant season amplitude errors in atmospheric modes are not limited to coupled runs but are often already evident in AMIP simulations. This suggests that rectifying the egregious post-dominant season amplitude errors found in many models can be addressed in an atmospheric-only framework making it more tractable to address in the model development process.

54 ENVIRONMENTAL SCIENCES↗

A Penalty Scheme for Mitigating Uninstructed Deviation of Generation Outputs From Variable Renewables in a Distribution Market

With rapid growth of distributed renewable generation, the establishment of electricity distribution markets has attracted widespread concerns. Different from existing transmission grid-scale electricity markets, an electricity distribution market is featured by numerous small-scale prosumers, and zero marginal cost and intermittency of renewable generation units. Against this background, this paper first extends an average pricing market (APM) mechanism for pricing renewable generation outputs with zero marginal cost in the distribution network concerned. Then, to mitigate the uninstructed volatility of renewable generation outputs and power demand, a penalty scheme is proposed for deviations between the real-time demand/output and market cleared bid/offer, with frequency regulation service (FRS) from energy storage systems (ESSs) considered. It is proved that the market volatility can be well controlled within an expected limit through properly setting the penalty prices for load demand and generation output fluctuations. Also, with this mechanism a non-negative market surplus could always be attained. Case studies are carried out to demonstrate the feasibility and efficiency of the proposed distribution market mechanism and penalty scheme.

electricity distribution market↗

Three-function signal generator

Variable-frequency circuit develops sine square and triangular waveforms. Three-function generator used variable-rate integrator to generate triangular wave and zero-crossing detector to develop square wave. Sine wave generator uses diode matrix to operate on triangular wave, thus with design harmonic distortion in output is less then one percent. By changing values of outboard resistors and capacitors, same design can be used at higher frequencies.

Kopp, G. F.↗

Stochastic Modeling Workflow to Generate Representative Geologic Variability in Training Dataset for SMART Initiative

The poster discusses the modeling workflow to generate ensemble of geologic realizations of the Illinois Basin Decatur Project (IBDP) site, based on available site characterization data and inherent uncertainty of those data, for use by project collaborators in DOE SMART Initiative (Phase 2) to build their forward modeling, history matching, and optimization workflows. This poster is summarized from the technical report for the SMART project submitted to U.S. DOE earlier this year.

Ganesh, Priya Ravi↗

Observations of wind-generated waves on variable current

Laboratory measurements utilizing a laser probe are made for the slopes of wind waves generated on both positive and negative currents at different values of fetch. The data are then processed electronically to yield an average wave-slope spectrum in frequency space with 128 degrees of freedom. These spectra are used to obtain the growth of the spectral components at various frequency bands for increasing wind and different values of fetch and current. The results indicate that the growth of these components is not monotonic with the frictional wind speed, but rather exhibits an 'overshoot' phenomena at lower values of frictional wind speed, and in addition, displays a significant effect due to current. The peak location and spectral intensity of the spectra also show strong influence by the current condition. This results in the rms surface slope value increasing with negative current and decreasing with positive current. The results agree qualitatively with some theoretical predictions. The potential use of the current-induced effects as a means for remote sensing of ocean current is also briefly discussed.

Long, S. R.↗

Deep Generative Modeling of Periodic Variable Stars Using Physical Parameters

The ability to generate physically plausible ensembles of variable sources is critical to the optimization of time domain survey cadences and the training of classification models on data sets with few to no labels. Traditional data augmentation techniques expand training sets by reenvisioning observed exemplars, seeking to simulate observations of specific training sources under different (exogenous) conditions. Unlike fully theory-driven models, these approaches do not typically allow principled interpolation nor extrapolation. Moreover, the principal drawback of theory-driven models lies in the prohibitive computational cost of simulating source observables from ab initio parameters. In this work, we propose a computationally tractable machine learning approach to generate realistic light curves of periodic variables capable of integrating physical parameters and variability classes as inputs. Our deep generative model, inspired by the transparent latent space generative adversarial networks, uses a variational autoencoder (VAE) architecture with temporal convolutional network layers, trained using the OGLE-III optical light curves and physical characteristics (e.g., effective temperature and absolute magnitude) from Gaia DR2. A test using the temperature–shape relationship of RR Lyrae demonstrates the efficacy of our generative “physics-enhanced latent space VAE” (PELS-VAE) model. Such deep generative models, serving as nonlinear nonparametric emulators, present a novel tool for astronomers to create synthetic time series over arbitrary cadences.

79 ASTRONOMY AND ASTROPHYSICS↗

Combined Cycle Integrated Thermal Energy Storage “CiTES” (Final Scientific/Technical Report)

The Phase I of this project confirmed the technical feasibility of a Combined Cycle integrated Thermal Energy Storage “CiTES” system, calculated the key performance parameters like power efficiency and costs, and proved its commercial value with full-year simulations for several US electricity markets with high degree of variable renewable generation and volatile hourly electricity prices. The core element of this project is the Electro Thermal Energy Storage (ETES) technology from Siemens Gamesa Renewable Energy GmbH, using thermally stable and inexpensive volcanic rocks as storage material and air as heat transfer medium. This technology is backed by more than 10 years of experience and a 440MMBTU (130MWh-th) pilot plant in Hamburg, Germany, which is in operation since 2019. The integration of this thermal storage in an existing combined cycle power plant (CCPP) is typical power plant technology without any major technology risks. It allows the storage of inexpensive renewable energy during times of surplus renewable generation and the discharge of this energy in times of high energy demand when the fossil plant is in operation. This supplements the fossil power generation with CO2-emission-free energy. The secondary effect of the CiTES system is that a small part of the stored thermal energy is used to keep the heat recovery steam generator (HRSG) and steam turbine (ST) of the combined cycle power plant in hot and ready-to-start condition. This enables the plant to start rapidly when fossil generation is required to satisfy demand as soon variable generation drops off in the evenings or during cloud cover and calm wind periods. Without pre-warming of the HRSG and ST, the CCPP would need several hours for a cold or warm start, burn a lot of gas and release high NOx emissions during start and wouldn’t be able to use the short times of high energy prices in an efficient or economical manner. The economic parameters of CiTES were determined by a full year “8760” simulation using a data set calculation for each of the hours of the year, and historical electricity and gas prices. For consistency, the simulations were focused on the pre-COVID year 2019. The financially most attractive markets were in the Energy Reliability Council of Texas (ERCOT) region, which allowed substantial value generation with arbitrage (charge with cheap energy during renewable surplus times and discharge when energy is needed and expensive). The improvement of flexibility with the CiTES system by pre-heating and warm-keeping of the CCPP allowed for additional power generation during short time periods when demand is high but renewable generation is down; when the hourly energy prices are highest in these markets. The simulations are based on 2019 data, when ERCOT had 27GW of installed photovoltaic (PV) and wind generation. They showed that the created revenue with the prototypically sized CiTES system of 1,000MMBTU (300MWh-th) falls a little bit short of what is expected from a commercially viable investment. The system has optimization opportunities for cost reduction and increased effectiveness which will be realized during a potential Phase II Pre-FEED study following this project. Furthermore, it is safe to assume that a lot of renewable generation capacity will be added all over the US in the coming years. As an example, ERCOT is predicting to more than double its renewable generation from 27GW in 2019 to a forecasted 63GW in 2023. This will increase the amount of renewable overproduction exponentially. This rapid increase of local overproduction and the need to curtail renewable generation is well documented by the California ISO (www.CAISO.com / managing oversupply). However, the simulations also revealed a weakness in the structure of the electricity markets in the US. More specifically, when electricity prices are very low and approaching negative levels, the owners of Variable Renewable Energy (VRE) will curtail a part of their facility to stabilize the price by reducing supply. This results in a situation in which storage facilities, which are integrated in existing fossil assets and don’t have the behind-the-meter benefit of a VRE, won’t be able to purchase low cost – otherwise curtailed – renewable energy off the grid. A special tariff, which motivates VRE owners to sell otherwise curtailed renewable energy to storage facilities (Hydrogen, thermal, pumped hydro, etc.) can solve this issue. The implementation of such a regulating tariff by Independent System Operators, thus avoiding renewable curtailment, is a pre condition for successful commercialization for renewable energy storage technologies. With this advancement of design and technology and improvements in the market environment, it can be expected that the Combined Cycle integrated Thermal Energy Storage proves itself as an important innovation to keep highly efficient, natural gas-based power generation economically successful and relevant for the power industry in the United States of America.

Wolf, Thorsten↗

Dynamic Building Load Control to Facilitate High Penetration of Solar Photovoltaic Generation (Final Technical Report)

Solar photovoltaic (PV) resources are the most common form of distributed generation in residential and commercial customer premises within electric distribution networks. A higher penetration of PV generation in distribution circuits will impose challenges on maintaining service voltages within the range of industry standards, power quality, and power flow. Buildings consume 74% of the electricity produced in the United States, and a significant portion of the building load is dispatchable, making them responsive to electrical grid needs. Oak Ridge National Laboratory—in collaboration with Southern Company; the University of Tennessee, Knoxville; and the Georgia Institute of Technology—is examining the PV integration issues in distribution-level electrical grids and developing integrated demand-side control and communication systems to enable responsive loads. The proposed responsive loads mechanism performs renewable generation following to increase the penetration of solar PV within each feeder. The specific objectives of this project are to (1) examine distribution-level PV integration scenarios to understand requirements, (2) undertake an end-to-end simulation-based design of a distributed control strategy of loads geographically near the PV generation asset to minimize the effect on the distribution feeder, (3) deploy and demonstrate the control technology developed in partnership with utilities, and (4) perform a scalability analysis at the utility scale. This 3-year integrated project aims to develop, demonstrate, and validate demand-side control technology to enable increased the penetration of renewables while mitigating challenges that arise due to their intermittency. Activities in Budget Period (BP) 1 focused on a literature review and the formal design of a control system for integrating local distribution with generation and loads. The team used modeling and simulation to evaluate the impact of varying buildings loads, variable PV generation, and power flow dynamics on the distribution circuit. The dynamic models developed in BP 1 were used in BP 2 to develop a model-based control design and a test bed. The test bed has enabled the simulation-based testing and comparison of different control designs and formulations applied to different configurations of the distribution grid, PVs, and building loads. The control approaches developed in BP 2 were implemented in BP 3 in the form of hardware deployed at the Central Baptist Church (CBC) in Knoxville, Tennessee, for testing and evaluation. The outcome of this project was the development and demonstration of open-source, low-cost, low-touch sensing and control retrofits to distributed PV generation and building loads that, in a coordinated fashion, provide the load-shaping response needed to integrate high levels of renewable penetration. This research addresses the target metrics by dynamically controlling a load with solar generation variability to minimize the extent of two-way power flow, enhance reliability, facilitate high PV penetration (>100% of peak load in a line segment), and generate scalable software and hardware solutions adaptable to any penetration levels. The research and development activities are focused and designed to be impactful within the relevant 2020 targets time frame.An accurate open-source integration simulation framework for end-to-end control design was developed and deployed at the CBC facility for testing and evaluation. This final report provides a detailed review of the technical results achieved during this 3-year integrated project. A novel spectral analysis of PV data is demonstrated to derive the requirements of the control design. A detailed simulation-based analysis of PV integration at increasing penetration levels is presented using 1 year of PV data to demonstrate the impact on the distribution circuits. Two different control strategies were developed and demonstrated via simulation to track variable PV generation with adaptive load dispatch. The report concludes with a summary of accomplishments and recommendations for a path forward.

14 SOLAR ENERGY↗

Generating Essential Climate Variables from Multiple Satellite Hyperspectral Remote Sensors

Hyperspectral observations from satellite-based sensors provide high information content for the Earth’s atmospheric and surface properties. Traditionally, long-term climate products are derived by performing spatial and temporal averaging of level-2 satellite products. There are two shortcomings of this approach. First, it is a time-consuming process to generate level-2 data products since modern hyperspectral satellite sensors have millions of observations each day with thousands of spectral channels for each observation. Secondly, differences in level-2 retrieval algorithms can lead to errors in the fused multi-satellite data. We have developed a radiometrically consistent spectral fingerprinting method, which overcomes the above-mentioned shortcomings, to derive climate change signals from multiple satellite sensors using spatiotemporally averaged level-1 data. We have applied this method to data collected from Atmospheric Infrared Sounder (AIRS) on Aqua satellite and Cross-track Infrared Sounder (CrIS) on SNPP and NOAA20 and generated decade-long climate data records for atmospheric temperature, water vapor, cloud, trace gases, and surface skin temperature. A key component to this work is a set of observational-based radiative kernels produced from CrIS level-1 data using a single field of view (SFOV) optimal estimation retrieval algorithm. Only limited CrIS level-1 data (e.g., 1-2 years of data) are needed to the derive radiative kernels. Our Principal Component-based Radiative Model (PCRTM) enables us to perform SFOV retrievals under all sky conditions and provides radiative kernels (including those for clouds) needed by the spectral fingerprinting method. In this presentation, we will describe the basic methodology, the details of the algorithm, and results from NASA Aqua AIRS and Suomi-NPP CrIS data. The method can be applied to study future hyperspectral remote sensors such as CLARREO (Climate Absolute Radiance and Refractivity Observatory) Pathfinder (CPF), Tropospheric Emissions: Monitoring of Pollution (TEMPO), Surface Biology and Geology (SBG), Atmosphere Observing System (AOS).

Xu Liu↗

Wind, Wave, and Tidal Energy Without Power Conditioning

Most present wind, wave, and tidal energy systems require expensive power conditioning systems that reduce overall efficiency. This new design eliminates power conditioning all, or nearly all, of the time. Wind, wave, and tidal energy systems can transmit their energy to pumps that send high-pressure fluid to a central power production area. The central power production area can consist of a series of hydraulic generators. The hydraulic generators can be variable displacement generators such that the RPM, and thus the voltage, remains constant, eliminating the need for further power conditioning. A series of wind blades is attached to a series of radial piston pumps, which pump fluid to a series of axial piston motors attached to generators. As the wind is reduced, the amount of energy is reduced, and the number of active hydraulic generators can be reduced to maintain a nearly constant RPM. If the axial piston motors have variable displacement, an exact RPM can be maintained for all, or nearly all, wind speeds. Analyses have been performed that show over 20% performance improvements with this technique over conventional wind turbines

Jones, Jack A.↗

Managing Solar Photovoltaic Integration in the Western United States: Power System Flexibility Requirements and Supply

As penetrations of variable renewable energy generation technologies such as wind and solar photovoltaics (PV) continue to increase across the United States, greater uncertainty and variability in the net load often lead to a concern about how power systems may adapt. Managing the system net load (i.e., load minus contribution from variable generation technologies) may become more challenging with increasing variable generation, as the magnitude and frequency of net ramps increase. However, there is inherent flexibility in power systems through the conventional generator fleet (under least-cost unit commitment and economic dispatch), less-conventional generation sources (e.g., storage, demand response, concentrating solar power with thermal energy storage), and imports and exports with neighbors. In this analysis, we create an open-source tool to analyze the flexibility of the results of a specific commercial unit commitment and economic dispatch tool (PLEXOS), but the code can be applied generically as well. The tool assesses the flexibility requirements (or demand) of a system through a net load analysis. The constraints and limitations of each generator are then considered to determine the availability (or supply) of flexibility. Then, the supply and demand of flexibility are compared to gain a more complete picture of potential flexibility concerns. We apply this open-source tool to high-penetration PV scenarios constructed for three focus regions in the western United States defined using the Resource Planning Model (RPM) capacity expansion modeling tool: RPM-OR, RPM-CO, and RPM-AZ. Generally, we find few flexibility concerns, as the western United States represents a large and interconnected power system with significant inherent flexibility. In addition, the PV scenarios we analyzed are overbuilt on capacity, leaving plenty of ramping ability on the system. We do find that for each focus region, the impact of imports on meeting ramping needs is essential. This means the PV integration in each focus region impacts the entire rest of the system. Each system has different dominant sources of flexibility. The conventional generator fleet (especially coal and gas combined-cycle technologies) as well as less-conventional sources such as storage are all shown to be important sources of flexibility. The scenarios evaluated here were designed to study the planning and operations impact of high solar penetration in each of three focus regions. However, none of the three focus regions likely will deploy PV in isolation, meaning the ability of imports and exports to provide flexibility may be considerably different in scenarios with strong PV deployment in every region. Overall, we intend that the framework we present here will be useful in future analysis of other system evolutions to identify whether and how flexibility may constrain the successful deployment of variable generation technologies.

14 SOLAR ENERGY↗

An electrical generator with a variable speed input: Constant frequency output

A new type of rotary energy conversion device for obtaining a desired constant frequency output independent of the speed of the prime mover has been developed and tested using the technique of field modulation and solid state alternator output processing. A 10-kilowatt prototype field modulated frequency down converter system was designed, built, and successfully tested. Experimentally obtained performance characteristics are presented.

Allison, H. J.↗

Impact of Geothermal District Heating System on Flexibility of Microgrid in Tuttle, Oklahoma: Preprint

Flexibility is the capability of the power grid to maintain a balance between electricity generation and variable demand. This study presents preliminary results evaluating the impact of geothermal district heating systems on the flexibility of a conceptual microgrid in Tuttle, Oklahoma. Heating demand profiles were modeled using EnergyPlus for the district that includes two schools and 250 single-family houses. Then, geothermal energy production was modeled using GEOPHIRES to estimate how much heating demand in the district can be supplied by five different geothermal system scenarios. The results indicated that geothermal energy production varied depending on the resource temperature at different depths, system configurations, and flow rates. For the grid flexibility analysis, electricity consumptions in the five geothermal systems were estimated for pump operations to circulate water from the wells to radiators, while electricity consumption by air-source heat pump in the base case was estimated to supply the same heating load. Electricity consumption in the geothermal systems was significantly lower than those in base cases. The electricity saved by the geothermal system was then incorporated into the microgrid electrical load profiles where variable renewable electricity generation is significantly high. The results visually showed that geothermal district heating system can improve grid flexibility as a baseload during the winter season. The results also highlighted potential opportunities to save energy costs that will be further analyzed in future study.

Cambium↗

Impact of Geothermal District Heating System on Flexibility of Microgrid in Tuttle, Oklahoma

Flexibility is the capability of the power grid to maintain a balance between electricity generation and variable demand. This study presents preliminary results evaluating the impact of geothermal district heating systems on the flexibility of microgrid in Tuttle, Oklahoma. Heating demand profiles were modeled using EnergyPlus for the district that includes two schools and 250 single-family houses. Then, geothermal energy production was modeled using GEOPHIRES to estimate how much heating demand in the district can be supplied by five different geothermal system scenarios. The results indicated that geothermal energy production varied depending on the resource temperature at different depths, system configurations, and flow rates. For the grid flexibility analysis, electricity consumptions in the five geothermal systems were estimated for pump operations to circulate water from the wells to radiators, while electricity consumption by air-source heat pump in the base case was estimated to supply the same heating load. Electricity consumption in the geothermal systems was significantly lower than those in base cases. The electricity saved by the geothermal system was then incorporated into the microgrid electrical load profiles where variable renewable electricity generation is significantly high. The results visually showed that geothermal district heating system can improve grid flexibility as a baseload during the winter season. The results also highlighted potential opportunities to save energy costs that will be further analyzed in future study.

Cambium↗

Rethinking the Role of Financial Transmission Rights in Wind-Rich Electricity Markets in the Central U.S.

Transmission congestion can cause a divergence between wholesale power prices at the individual pricing nodes where power is generated and the more-liquid trading hubs where that power is often delivered and sold. This nodal price difference is commonly referred to as the “locational basis” (or just “basis”). Because the basis varies over time, it can—if not hedged—unpredictably affect a wind plant’s revenue and/or value, which increases investor risk and potentially slows deployment. We find wind plants typically face a larger and more-negative basis than do thermal generators, and hence are more-negatively impacted by congestion. Moreover, while most thermal generators can effectively hedge basis risk by purchasing conventional fixed-volume financial transmission rights (FTRs), these fixed-volume FTRs do not effectively hedge basis risk for variable wind generation. More-effective hedging mechanisms may be required to support those generators most-impacted by congestion, and to promote continued investment in variable generation resources in congested markets.

17 WIND ENERGY↗

Control system design for the MOD-5A 7.3 mW wind turbine generator

This paper provides descriptions of the requirements analysis, hardware development and software development phases of the Control System design for the MOD-5A 7.3 mW Wind Turbine Generator. The system, designed by General Electric Company, Advanced Energy Programs Department, under contract DEN 3-153 with NASA Lewis Research Center and DOE, provides real time regulation of rotor speed by control of both generator torque and rotor torque. A variable speed generator system is used to provide both airgap torque control and reactive power control. The wind rotor is designed with segmented ailerons which are positioned to control blade torque. The central component of the control system, selected early in the design process, is a programmable controller used for sequencing, alarm monitoring, communication, and real time control. Development of requirements for use of aileron controlled blades and a variable speed generator required an analytical simulation that combined drivetrain, tower and blade elastic modes with wind disturbances and control behavior. An orderly two phase plan was used for controller software development. A microcomputer based turbine simulator was used to facilitate hardware and software integration and test.

Barton, Robert S.↗

Applying Particle Swarm Optimization and Extended Kalman Filtering to Model Kaplan Generation Dynamics for Hydropower Systems

Variable renewable generation is increasing the need for hydropower plants to provide fast and flexible grid support, which places new demands on plant-level dynamic models used for monitoring, control, and operational decision-making. This need is especially important for hydroelectric systems, where turbine and generator dynamics are strongly coupled, nonlinear, and time-varying, making accurate real-time representation difficult. To address this problem, this paper develops a digital twin (DT) framework for a synchronous generator–Kaplan turbine system using an explicit separation of slow turbine dynamics and fast generator dynamics. The turbine subsystem is represented by a six-coefficient model, whose parameters are identified offline using particle swarm optimization, while the generator subsystem is updated online through an extended Kalman filter for real-time state and parameter estimation. These models are integrated within a closed-loop simulation that includes a proportional–integral–derivative–double-derivative governor and excitation system, allowing the DT to track plant behavior under realistic operating conditions. Unlike prior studies that treat turbine and generator modeling separately or rely mainly on simulated inputs, the proposed framework is validated using real operational data from a hydropower plant. Results show that the DT reproduces terminal voltage, active power, and reactive power with a normalized root mean square error of approximately 5%. This hybrid offline–online formulation constitutes the main contribution of the work, providing an adaptive and practically deployable DT for hydropower systems with direct relevance to control improvement, performance monitoring, and grid-support applications under high renewable penetration.

13 HYDRO ENERGY↗