Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “variable energy generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Characterizing the Energy Scale of the XRS on Astro-E2

The XRS on Astro-E2 consists of a microcalorimeter array with 31 active pixels. The XRS energy scale, which converts the measured pulse heights to the energies of the photons incident on the array, is a non-linear function of the thermal properties of the pixels and the power and noise conditions on the array. Each of the pixels operates independently and requires an individual energy scale. Analytic models of the XRS pulses are currently being developed that will be used to model the energy scale. However, because of the inherent complexity, a full empirical calibration of the energy scale is being conducted. The XRS energy scale has been calibrated for a range of operating conditions including variations in the detector temperature, bath temperatures, and photon flux. This allows us to characterize the functional dependence of the energy scale on these variables and to then generate a semi-empirical model that can be used to account for variations in operating conditions in space. We will present the results of the empirical characterization and comparisons to the analytic models.

Cottam, J.↗

The Impact of ENSO on Extratropical Low Frequency Noise in Seasonal Forecasts

This study examines the uncertainty in forecasts of the January-February-March (JFM) mean extratropical circulation, and how that uncertainty is modulated by the El Nino/Southern Oscillation (ENSO). The analysis is based on ensembles of hindcasts made with an Atmospheric General Circulation Model (AGCM) forced with sea surface temperatures observed during; the 1983 El Nino and 1989 La Nina events. The AGCM produces pronounced interannual differences in the magnitude of the extratropical seasonal mean noise (intra-ensemble variability). The North Pacific, in particular, shows extensive regions where the 1989 seasonal mean noise kinetic energy (SKE), which is dominated by a "PNA-like" spatial structure, is more than twice that of the 1983 forecasts. The larger SKE in 1989 is associated with a larger than normal barotropic conversion of kinetic energy from the mean Pacific jet to the seasonal mean noise. The generation of SKE due to sub-monthly transients also shows substantial interannual differences, though these are much smaller than the differences in the mean flow conversions. An analysis of the Generation of monthly mean noise kinetic energy (NIKE) and its variability suggests that the seasonal mean noise is predominantly a statistical residue of variability resulting from dynamical processes operating on monthly and shorter times scales. A stochastically-forced barotropic model (linearized about the AGCM's 1983 and 1989 base states) is used to further assess the role of the basic state, submonthly transients, and tropical forcing, in modulating the uncertainties in the seasonal AGCM forecasts. When forced globally with spatially-white noise, the linear model generates much larger variance for the 1989 base state, consistent with the AGCM results. The extratropical variability for the 1989 base state is dominanted by a single eigenmode, and is strongly coupled with forcing over tropical western Pacific and the Indian Ocean, again consistent with the AGCM results. Linear calculations that include forcing from the AGCM variance of the tropical forcing and submonthly transients show a small impact on the variability over the Pacific/North American region compared with that of the base state differences.

Schubert, Siegfried D.↗

Role of Electric Vehicles in the U.S. Power Sector Transition: A System-Level Perspective

After over a century of petroleum dominance many anticipate that electrification could disrupt the transportation energy landscape. At the same time, the electric power systems are undergoing profound changes: variable renewables are displacing conventional generation sources; distributed generation is disrupting utility business models; energy storage and other new technologies are emerging; and the traditional system based on the premise that generation is dispatched to match an inelastic demand is evolving to create a system with greater participation in power system planning and operations from traditionally passive consumers. In this context, it is important to understand how transportation electrification will impact electricity demand and in turn electricity supply, including changes in the load shapes that characterize the system and the opportunity to leverage flexible electric vehicle (EV) charging to better integrate demand and supply. Assessing the impacts of electrification on the energy system requires an understanding of how it might impact the amount and shape of electricity consumption, and how this electricity can be supplied. In particular, increased adoption of electric vehicles introduces a new source of demand altogether, potentially very flexible. Moreover, electrification could shift the consumption of natural gas between sectors, thereby affecting the economics for natural gas-fired generation relative to other electricity generation options. Several factors will impact the evolution of the power system under a widespread electrified future, which, in turn, could have far-reaching effects on future energy costs and emissions.

47 OTHER INSTRUMENTATION↗

Lower Snake River Dams Contribution to Grid Services

Hydroelectric generation and water storage have long been components of the clean energy mix, providing both reliable steady output and operational flexibility. As variable renewable energy sources such as wind and solar increasingly replace traditional generation, the role of all flexible resources—including hydropower—in balancing supply and demand continues to evolve. This study examined the contribution of the Lower Snake River (LSR) Dam plants to Bonneville Power Administration grid services in maintaining power system reliability within the Western Interconnection. By analyzing publicly available data, the study evaluated various reliability services through performance metrics including energy capacity, balancing and ramping, voltage and reactive power support, frequency response, and transmission impact. Results indicated that the LSR plants deliver services as expected based on their size, contributing to the balancing process, ramping capabilities, and operational reserves, particularly during peak load conditions and weather events, while also providing measurable frequency and voltage support to the grid.

13 HYDRO ENERGY↗

Mesoscale and large-scale variability of the Antarctic circumpolar current

This investigation of the physical oceanography of the Southern Ocean will carry out two parallel efforts during the years preceding the launch of TOPEX/POSEIDON. First, the Geosat data will be used to develop a preliminary descriptive picture of the mesoscale and large-scale, low-frequency surface circulation of the Southern Ocean. Some of this analysis of Geosat data has already begun. For example, as a measure of the geographical distribution of mesoscale variability, a color-coded map of the standard deviation of sea level from two years of Geosat data is shown. Efforts are presently under way to investigate the seasonal and year-to-year variability of this mesoscale energy. The data are also being used to generate low-pass filtered fields of sea level from which the temporal evolution of large-scale variability in the Southern Ocean may be investigated. The second parallel effort is the development and test of modeling and data assimilation techniques that will later be applied to TOPEX/POSEIDON data during the postlaunch phase. One objective of the modeling and data assimilation is to investigate the relation between mesoscale sea level variations and eddy flux in the Southern Ocean. Uncertainties in present estimates of the various components of meridional oceanic heat transport are large. The evidence presented indicates that the very energetic mesoscale variability in the ACC apparently accounts for much of the estimated 0.45x10(exp 15) watts of poleward heat transport across the ACC required to balance the heat budget. Eddy variability is strongly coherent vertically in the ACC, at least in the vicinity of Drake Passage where nearly all of the historical in situ data have been collected.

Chelton, Dudley B.↗

Net-Zero Carbon Microgrids

The microgrid concept has been effective in creating aggregations of distributed energy resources—generation, storage and loads—for resiliency, in the form of energy security. The success of microgrids in bringing energy security to a wide range of customers—from individual residences to commercial and industrial installations to military bases—has been exemplified during power disruptions and extended outages due to extreme weather events, cybersecurity attacks, and equipment failures. Now microgrids have an opportunity to meet the challenges of climate change and contribute to a carbon-free power delivery system. The transition to net-zero starts within microgrids themselves. In fact, today’s microgrids are largely dominated by generators using fossil fuels, natural gas and diesel, with high greenhouse gas emissions. In short, the transition to net-zero means replacing fossil fueled generators with renewable generation in microgrids. This transition is extended by including new dispatchable generation technologies that are 100% carbon-free and that offer additional advantage of a more-dependable and sustainable source of energy and power. Basically, the decarbonization of microgrids requires three elements: 1) maximizing generation from renewable energy resources, 2) management of storage and flexible loads to balance the variability and intermittency of renewable energy resources, and 3) introducing new clean power sources, including hydrogen-based generation and small modular reactors. This report affirms a need for specific focus by governmental agencies at national, regional, and local levels to establish technology, policy, and investment in this area. The intention of the Net-Zero Microgrid (NZM) Program is to inform these constituencies with cross-cutting research and tools for the reduction of GHG in microgrids – to net-zero in the near term eventually to zero in the longer term. The NZM Program is committed to achieving decarbonization for resiliency and for providing clean energy at the local or distribution level, from remote communities to underserved communities, and large industrial and military facilities. The NZM Planning and Design Platform is a core tool to be developed as an early deliverable of the NZM Program because only a fully integrated microgrid-design approach will ensure maximum carbon reduction in energy production.

13 HYDRO ENERGY↗

Storage Futures Study: Grid Operational Impacts of Widespread Storage Deployment

This report, the fifth in the Storage Futures Study series, uses cost-driven scenarios from the ReEDS model as a starting point to examine the operational impacts of grid-scale storage deployment and relationships between this deployment and the contribution of variable renewable energy. We use commercial production cost modeling software to evaluate hourly operation of five scenarios that reach between 210 gigawatts (GW) and 930 GW of installed storage by 2050. We find that storage plays an important role in these power systems between now and 2050 - by storing the lowest-marginal cost generation (often, overgeneration from solar or wind plants) and generating energy during the highest net load periods of the day and year. Storage helps with the integration of variable renewable energy and by providing an important resource to provide continued reliable power.

battery↗

Variability and Diversity Load Model Tool [SWR-20-03]

The motivation for the development of this tool and the underlying algorithms and methods was to enable the development of high-temporal resolution, realistic time-series data for quasi-static time-series (QSTS) analysis of distribution systems. Often, aggregated load profile data for a distribution circuit is available (e.g. feeder loading data collected via SCADA at the utility substation) and, while this data is typically accurate it masks the considerable variability of the 100’s or 1000’s of individual loads connected on the circuit. This tool was developed to model both the increased variability expected for these individual loads (e.g. the load of a single distribution transformer connected to 8-12 houses) and the expected diversity between loads on the circuit. It is important to note that the difference in variability and diversity, in the context of this tool, is that variability modeling only adds representative variability due to disaggregated load characteristics (e.g. the presence in the load profile of loads turning off and on like an air conditioner/oven) while the average energy profile remains the same as the user supplied power profile. Diversity modeling generates multiple individual load profiles which, in aggregate, sum to the user supplied power profile. Diversity is effectively variability in the energy usage over longer periods of time than seen in the variability model. Put another way, variability modeling supplies the expected variability due to the operation of various end-use loads and diversity modeling supplies the usage differences due to human behavior, schedules, etc. This load modeling tool was developed for use in generating data for distribution systems. Modeling is summarized by two major functions: 1) taking low resolution load profiles and adding intra-seconds variability onto the profiles, and 2) taking a user supplied load profile and distribution factors and adding both diversity and variability to the user supplied profile.

Zhu, Xiangqi↗

An electrical generator with a variable speed input: Constant frequency output

A new type of rotary energy conversion device for obtaining a desired constant frequency output independent of the speed of the prime mover has been developed and tested using the technique of field modulation and solid state alternator output processing. A 10-kilowatt prototype field modulated frequency down converter system was designed, built, and successfully tested. Experimentally obtained performance characteristics are presented.

Allison, H. J.↗

NTAC Augmented Nuclear and Advanced Propulsion

Currently, there are two types of nuclear propulsion: Nuclear Thermal Propulsion (NTP) and Nuclear Electric Propulsion (NEP). Common to both types, a nuclear reactor generates heat energy to raise the temperature of propellant, or the generated heat energy is converted into electric power. The electricity generated powers propulsion systems, such as a Hall thruster, magnetoplasma dynamic (MPD) thruster, or variable specific impulse magnetoplasma rocket (VASIMR). Customarily, only the thermal energy output from nuclear reaction is considered for NTP and NEP systems. However, the nuclear fission reaction can also generate ~7 MeV of prompt gamma rays. Therefore, most designers of NTP and NEP systems incorporate safety features to shield against this radiation. An optimized design approach would be to integrate a Nuclear Thermionic Avalanche Cell (NTAC) within the NTP or NEP structure for converting this radiation energy into additional electric power, while also shielding gamma rays. Consequently, this study addresses several combinations of NTP and NEP structures with NTAC devices in order to achieve that goal.

NTAC↗

Utilization of an Advanced Sensor network to determine fuel heating value and Real-Time net unit heat rate during transient operation

Coal-fired utility boilers are being increasingly used as variable electricity generation to resolve the imbalance in the energy market from the expansion of intermittent renewable energy. The frequent transient operation required to meet residual energy demand has created a challenge for coal-fired units to operate efficiently. This work utilizes an advanced sensor network (ASN) to calculate net unit heat rate (NUHR) of a coal-fired boiler in real time through combustion calculations and statistical correlations to provide the tools for optimizing dynamic operation. Real-time heating values that were necessary to determine fuel input energy to calculate accurate NUHR were found using both fundamental and data-driven methods. Real-time NUHR shows distinct shifts that reflect changes in process conditions that will improve the ability to optimize transient operation. Data-driven heating value correlations had 24% lower root mean square error (RMSE) than the fundamental combustion calculation approach when compared to daily retrospective proximate analysis. Furthermore, the data-driven method RMSE improved by 7% with the inclusion of ASN data. Future work is to validate by comparing unit performance with and without the inclusion of NUHR as a control parameter for the dynamic neural network.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Demonstration System for Geological Thermal Energy Storage of Concentrating Solar Thermal

Energy storage is increasingly necessary as variable energy technologies are deployed. Seasonal energy storage can shift energy generation from the summer to the winter, but these technologies must have extremely large energy capacities and low costs. Geological Thermal Energy Storage (GeoTES) is proposed as a solution for long-term energy storage [1]. Excess thermal energy can be stored in permeable reservoirs such as aquifers and depleted hydrocarbon reservoirs for several months. The energy capacity cost of GeoTES is very low which makes it suitable for both daily- and seasonal storage of Concentrating Solar Thermal (CST) energy, thus enabling CST to provide value to electricity markets and thermal energy off-takers. A CST-GeoTES demonstration system has been funded by the U.S. Department of Energy, Solar Energy Technology Office. In this article, we will describe this demonstration system and progress that has been made in its development. The demonstration system will comprise a 2 MWth parabolic trough with an 8m aperture developed by Gossamer Space Frames, seven wells, and a 100 kWe power cycle. The demonstration system will be deployed in Kern County, California by Premier Resource Management. A techno-economic model for CST-GeoTES systems has also been developed [3] and is applied to the demonstration system and its planned future expansion. The model integrates the output of specialist models of each subsystem, which enables the performance and cost of both the subsurface and surface systems to be captured. Off-design models enable the performance to be evaluated at each hour of the year, before being aggregated to evaluate the economic potential of CST-GeoTES. Initial analysis indicates that CST-GeoTES can provide long duration energy storage capabilities with low marginal costs of energy capacity - leading to a low value of Levelized Cost of Storage (LCOS) compared to alternative technologies, see Figure 2. In this article, we investigate the cost and performance of the specific demonstration site being developed by PRM and explore a range of operational profiles that can deliver different value streams, such as daily and seasonal storage, capacity, and resiliancy.

14 SOLAR ENERGY↗

Pressure variable orifice for hydraulic control valve

Hydraulic valve absorbs impact energy generated in docking or joining of two large bodies by controlling energy release to avoid jarring shock. The area of exit porting presented to the hydraulic control fluid is directly proportional to the pressure acting on the fluid.

Ammerman, R. L.↗

Hybrid Electric Transit Bus

A government, industry, and university cooperative is developing an advanced hybrid electric city transit bus. Goals of this effort include doubling the fuel economy compared to current buses and reducing emissions to one-tenth of current EPA standards. Unique aspects of the vehicle's power system include the use of ultra-capacitors as an energy storage system, and a planned natural gas fueled turbogenerator developed from a small jet engine. Power from both the generator and energy storage system is provided to a variable speed electric motor attached to the rear axle. At over 15000 kg gross weight, this is the largest vehicle of its kind ever built using ultra-capacitor energy storage. This paper describes the overall power system architecture, the evolution of the control strategy, and its performance over industry standard drive cycles.

Viterna, Larry A.↗

Synergistic Heat Pumped Thermal Storage and Flexibly Carbon Capture System

As the U.S. grid evolves toward a lower-carbon system, fossil generation assets need to operate in energy markets with high variable renewable energy (VRE) penetration while also decreasing carbon emissions. Current carbon capture and storage (CCS) technologies suffer from high capital cost and an inability to operate flexibly during periods of oscillating demand. The ARPA-E FLECCS Program Phase 1 was created to fund designing and optimizing innovative CCS processes that enable flexibility on a high-VRE grid. To address this need, the Colorado State University (CSU) Team won funding to design a synergized system of thermal energy storage, power generation, and flexible carbon capture to enable breakthrough system performance that achieves an LCOE <$75/MWh with >99% capture rate. This approach will target new or existing natural gas combined cycle power plants. The proposed design utilizes novel hot and cold thermal energy storage (TES) technologies that store low-cost, off-peak electricity as thermal energy to power CCS solvent regeneration and boost plant output during periods of peak demand. The design provides an overall optimized net present value (NPV) by maximizing low carbon power to grid while prices are highest using Storworks Power’s concrete TES technology. The team also capitalizes on decades of ION Clean Energy’s (ION) development in low cost and flexible pioneering solvent technology, which has proven reductions in energy consumption and overall cost of 28% and 38%, respectively, compared with state-of-the-art CCS.

20 FOSSIL-FUELED POWER PLANTS↗

Drought Impacts on Hydroelectric Power Generation in the Western United States

The Western United States experiences large fluctuations in rain and snowfall from year to year, affecting river flows and reservoir levels throughout the region. This interannual variability in water resources leaves a strong signature on total annual energy generated by the region’s fleet of hydroelectric dams. In a wet year, like 2011, hydroelectric power can meet 30 percent of annual western electricity demand. That contribution can drop below 20 percent during severe drought years. Characterizing the contribution of hydroelectric power to the western generation portfolio during drought is crucial to understanding the resilience of the hydropower sector to climate-related risk, both now and in the future. This report analyzes the impacts of historical western droughts on hydroelectric power production by combining two decades’ worth of annual generation—recorded at more than 600 hydroelectric power plants—with historical climate data developed for distinct hydropower subregions of the West. The most extreme impacts of drought on hydroelectric power are found at individual dams where reservoir levels are so low that released water and thus generation becomes severely restricted. These isolated cases often receive widespread media attention, leading to a common misconception that hydroelectric power is an unreliable technology whose role will diminish over time as the western climate produces longer and more severe droughts. Yet, when aggregated to the scale of the West, the observational records of hydropower generation reveal a different story. Even during the most severe droughts experienced since the turn of the century, the western hydropower fleet sustained more than 80% of its typical annual generation. Observational data indicate that drought in 2021 led to the worst year for hydropower generation in the West since 2001, with total generation approximately 16 percent below the 21st century two-decade average. The year 2021 was particularly severe in California (second worst hydro year of last two decades, ~48 percent below average) and Oregon (worst hydro year of last two decades), while generation in Washington and Idaho was affected to a lesser degree (~12 percent below average for combined region). The year 2001 remains the year of lowest western hydropower generation of the twenty-first century so far, owing to extreme drought in the Pacific Northwest, where about two-thirds of western hydropower capacity is located. The primary reason for this relative stability is the diversity of weather across the West; drought rarely impairs hydroelectric power across all river basins at the same time.

13 HYDRO ENERGY↗

Pathways to the Next-Generation Power System With Inverter-Based Resources: Challenges and recommendations

Managing the stability of today's electric power systems is based on decades of experience with the physical properties and control responses of large synchronous generators. Today's electric power systems are rapidly transitioning toward having an increasing proportion of generation from nontraditional sources, such as wind and solar (among others), as well as energy storage devices, such as batteries. In addition to the variable nature of many renewable generation sources (because of the weather-driven nature of their fuel supply), these newer sources vary in size - from residential-scale rooftop systems to utility-scale power plants - and they are interconnected throughout the electric grid, both from within the distribution system and directly to the high-voltage transmission system. Most important for our purposes, many of these new resources are connected to the power system through power electronic inverters. Collectively, we refer to these sources as inverter-based resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Capacity Markets for Transactive Energy Systems

Capacity markets provide important incentives for resource adequacy in electricity markets and may become more important for providing sufficient revenue and generation capacity with changes to energy market prices driven by increasing levels of zero marginal cost resources. However, current capacity market designs also have important shortfalls that may limit the benefits they can provide to the future grid. Current capacity markets are primarily designed for participation from conventional thermal generators, but markets are evolving with increasing levels of variable renewable energy resources. However, further reforms may be necessary to enable more participation from DERs and demand-side resources. To understand the benefits and shortfalls of current capacity market design, we review the historical reasons electricity markets have needed capacity markets or capacity payments for resource adequacy, and how current capacity market designs may create challenges for incorporating increasing levels of DERs and demand-side resources. We then consider how transactive systems, which allow the coordination of bids and offers for DERs and demand-side resources through a market interaction approach, administered by a Distribution System Operator (DSO), can address traditional resource adequacy problems due to inelastic consumer demand. We also consider the need for a DSO-level capacity market in helping to meet resource adequacy, reliability, and other electricity market objectives. We find that because the missing money in electricity markets is largely driven by incentives to meet resource adequacy goals, and the bulk grid would always supply power to the DSO, that resource adequacy is unlikely to be a determining factor in the need for a DSO-level capacity market. Many current reliability problems could also be addressed by the incorporation of more flexible demand enabled with transactive energy systems. However, other DSO objectives, including resilience, reactive power, voltage control, environmental policies, and energy equity could lead to specific challenges that could be aided by a DSO-level capacity market. We consider the possibility of a DSO-level capacity market in addressing these challenges as well as its potential role in coordinating with the Independent System Operator (ISO) who operates the wholesale market. We conclude with suggestions for future research, including the need to develop analytical models of DSO-level capacity market designs to address these potential objectives and examine their implications for DSOs and consumers.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗