Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “variable conductance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Heat pipes for spacecraft temperature control: An assessment of the state-of-the-art

Spacecraft applications that require the efficient cooling of high-powered components, the precise temperature control of sensitive electronic and optical components, and the protection of cooled components from temporary, adverse environmental conditions are increasing. Heat pipes using gas, vapor, liquid, or voltage control to provide variable conductance or diode thermal behavior have been and are continuing to be developed to meet increasingly difficult requirements. The various control techniques are critically evaluated using characteristic features and properties, including heat transport capability, volume and mass requirements, complexity and ease of fabrication, reliability, and control characteristics. As a result, advantages and disadvantages of specific approaches are derived and discussed. Using four development levels, the state-of-the-art of the various heat pipe temperature control techniques is assessed.

Groll, M.↗

Investigation of the thermal control of instruments mounted in the Space Shuttle cargo bay

Results are presented for an investigation intended to examine the orbital averaged thermal response of a number of instruments, each being representative of a class of scientific instrumentation, when they are individually mounted on pallets and operated in the cargo bay of the Shuttle. The discussion covers mainly the Shuttle Orbiter thermal models, the solar viewing instrument, and the high-energy instrument. One approach to thermal insulation of smaller instruments is to provide a thermal canister insulated from the cargo bay and equipped with variable conductance heat pipes. Two approaches are proposed for larger instruments. One approach is to provide a thermal curtain across the top of the pallet which shields the pallet cavity from direct sunlight, while the second approach is to provide a fluid system to transfer heat from a specified location on an instrument to either a space viewing radiator on the pallet or instrument or the orbiter cooling system. These thermal control design concepts represent several ideas for standard reusable thermal control systems.

Bartoszek, J. T.↗

Test program for transmitter experiment package and heat pipe system for the communications technology satellite

The test program is described for the 200 watt transmitter experiment package and the variable conductance heat pipe system which are components of the high-power transponder aboard the Communications Technology Satellite. The program includes qualification tests to demonstrate design adequacy, acceptance tests to expose latent defects in flight hardware, and development tests to integrate the components into the transponder system and to demonstrate compatibility.

Depauw, J. F.↗

Transmitter experiment package for the communications technology satellite

The operating requirements, system design characteristics, high voltage packaging considerations, nonstandard components development, and test results for the transmitter experiment package (TEP) are described. The TEP is used for broadcasting power transmission from the Communications Technology Satellite. The TEP consists of a 12 GHz, 200-watt output stage tube (OST), a high voltage processing system that converts the unregulated spacecraft solar array power to the regulated voltages required for OST operation, and a variable conductance heat pipe system that is used to cool the OST body.

Farber, B.↗

On-orbit performance of the 12 GHz, 200 watt transmitter experiment package for CTS

Performance characteristics from on-orbit tests of the transmitter experiment package (TEP) for the Communications Technology Satellite (CTS) are presented. The TEP consists of a power processing system (PPS), an output stage tube (OST) and a variable conductance heat pipe system (VCHPS), all of which are described. Test results presented include efficiencies, RF output power, frequency response, and performance with single and multiple (two) carriers, frequency-modulated by video signals.

Alexovich, R. E.↗

Early performance of the 12-GHz, 200-watt transmitter experiment package in the communications technology satellite

Measured performance characteristics of the transmitter experiment package (TEP) aboard the Communications Technology Satellite for the first 90 operating days in orbit are presented. The TEP consists of a nominal 200-watt output stage tube (OST), a supporting power processing system (PPS), and a variable-conductance heat pipe system (VCHPS). The OST, a traveling-wave tube augmented with a 10-stage depressed collector, has an overall saturated average efficiency of 51.5 percent and an average saturated radiofrequency (RF) output power at center-band frequency of 240 watts. The PPS operated with a measured efficiency of 86.5 percent to 88.5 percent. The VCHPS, using three pipes to conduct heat from the PPS and the body of the OST to a 52-centimeter by 124-centimeter (20.5-in. by 48.75-in.) radiator fin, maintained by the PPS baseplate temperature below 50 C for all operating conditions. The TEP performance characteristics presented include frequency response, RF output power, efficiency, and distortions. Communications characteristics were evaluated by using both video and audio modulated signals.

Source record↗

Instrument canister thermal control

A transient thermal analysis and test of a thermal control canister is described. The 1 x 1 x 3 m canister provides a uniform thermal environment for shuttle instrument payloads requiring fine temperature control, the design goal being operation between 0 C and 20 C with a range of plus or minus 1 C at any selected set-point temperature. The canister side walls are isothermalized by a system of longitudinal and circumferential heat pipes rejecting heat through feedback controlled, variable conductance heat pipes to side mounted radiators. A breadboard model of two side walls and two radiators was tested in a thermal vacuum chamber. The breadboard was stable over a wide range of effective environments, experiment dissipations, and control point temperature levels.

Harwell, W.↗

On-orbit performance of the 12 GHz, 200 watt transmitter experiment package for CTS

Performance characteristics from on-orbit tests of the Transmitter Experiment Package (TEP) for the Communications Technology Satellite (CTS) are presented. The TEP consists of a Power Processing System (PPS), an Output Stage Tube (OST), and a Variable Conductance Heat Pipe System (VCHPS), all of which are described. The OST is a coupled-cavity traveling-wave tube with a multistage depressed collector and a stepped velocity-tapered slow-wave structure for efficiency enhancement. It has an RF output power of 240 W and an overall efficiency of 51.5% at a center band frequency of 12.080 GHz. The PPS provides the required operating voltages, regulation, control, and protection for the OST. It has a measured dc-dc conversion efficiency of 86.5% to 88.5%. The VCHPS consists of a fin radiator and three dual-artery stainless steel heat pipes using methanol and a mixture of inert gases. Test results presented include efficiencies, RF output power, frequency response, and performance with single and multiple (two) carriers frequency-modulated by video signals.

Alexovich, R. E.↗

Thermal-control canister

Use of variable-conductance heat-pipe link together with fixed-conductance system allows canister temperature to vary over wide range, yet hold stable to + or - 1 degree Centigrade. System has fewer parts and requires considerably less power than conventional heaters and thermostats.

Ollendorf, S.↗

Performance of the 12GHz, 200 watt transmitter experiment package for the Hermes satellite

Performance characteristics from on-orbit tests of the Transmitter Experiment Package (TEP) for the Hermes Satellite are presented. The TEP consists of a Power Processing System (PPS), an Output Stage Tube (OST) and a Variable Conductance Heat Pipe System (VCHPS), all of which are described. The OST is a coupled-cavity Traveling Wave Tube (TWT) with a Multistage Depressed Collector (MDC) and a stepped velocity-tapered slow wave structure for efficiency enhancement. It has an RF output power of 233 watts and overall efficiency of 50.75 percent at a center band frequency of 12.080 GHz. The PPS provides the required operating voltages, regulation, control and protection for the OST. The VCHPS consists of a fin radiator and three dual-artery stainless steel heat pipes using methanol and a mixture of inert gases. Test results presented include efficiencies, RF output power and body current. A discussion of thermal anomalies which occurred is presented.

Alexovich, R. E.↗

Accelerated life tests of specimen heat pipe from Communication Technology Satellite (CTS) project

A gas-loaded variable conductance heat pipe of stainless steel with methanol working fluid identical to one now on the CTS satellite was life tested in the laboratory at accelerated conditions for 14 200 hours, equivalent to about 70 000 hours at flight conditions. The noncondensible gas inventory increased about 20 percent over the original charge. The observed gas increase is estimated to increase operating temperature by about 2.2 C, insufficient to harm the electronic gear cooled by the heat pipes in the satellite. Tests of maximum heat input against evaporator elevation agree well with the manufacturer's predictions.

Tower, L. K.↗

CTS TEP thermal anomalies: Heat pipe system performance

A part of the investigation is summarized of the thermal anomalies of the transmitter experiment package (TEP) on the Communications Technology Satellite (CTS) which were observed on four occasions in 1977. Specifically, the possible failure modes of the variable conductance heat pipe system (VCHPS) used for principal thermal control of the high-power traveling wave tube in the TEP are considered. Further, the investigation examines how those malfunctions may have given rise to the TEP thermal anomalies. Using CTS flight data information, ground test results, analysis conclusions, and other relevant information, the investigation concentrated on artery depriming as the most likely VCHPS failure mode. Included in the study as possible depriming mechanisms were freezing of the working fluid, Marangoni flow, and gas evolution within the arteries. The report concludes that while depriming of the heat pipe arteries is consistent with the bulk of the observed data, the factors which cause the arteries to deprime have yet to be identified.

Marcus, B. D.↗

Transverse flat plate heat pipe experiment

This paper describes a Shuttle-launched flight experiment to evaluate the performance of a transverse flat plate heat pipe that serves as an integral temperature control/mounting panel for electronic equipment. A transverse heat pipe is a gas-controlled variable conductance heat pipe that can handle relatively large thermal loads. An experiment designed to flight test the concept over a 6-9 month period is self-sufficient with respect to electrical power, timing sequences, and data storage.

Edelstein, F.↗

Heat pipe life and processing study

The merit of adding water to the reflux charge in chemically and solvent cleaned aluminum/slab wick/ammonia heat pipes was evaluated. The effect of gas in the performance of three heat pipe thermal control systems was found significant in simple heat pipes, less significant in a modified simple heat pipe model with a short wickless pipe section. Use of gas data for the worst and best heat pipes of the matrix in a variable conductance heat pipe model showed a 3 C increase in the source temperature at full on condition after 20 and 246 years, respectively.

Antoniuk, D.↗

Advanced Thermal control Flight Experiment (ATFE)

A comprehensive description of the design and performance of the Advanced Thermal Control Flight Experiment (ATFE) is presented. The ATFE studied in a space environment for five years the steady state, transient ground and flight performance of (1) a thermal diode heat pipe, (2) a phase change material, and (3) a feedback controlled variable conductance heat pipe. It was found that all were flight worthy and highly reliable.

Source record↗

Life characteristics assessment of the communications technology satellite transmitter experiment package

The performance characteristics of the transmitter experiment package (TEP) aboard the Communications Technology Satellite (CTS) measured during its first 2 years in orbit are presented. The TEP consists of a nominal 200 watt output stage tube (OST), a supporting power processing system (PPS), and a variable conductance heat pipe system (VCHPS). The OST, a traveling wave tube augmented with a 10 stage depressed collector has an overall saturated average efficiency of 51.5 percent and an average saturated radio frequency (rf) output power at center band frequency of 240 watts. The PPS operated with a measured efficiency of 86.5 to 88.5 percent. The VCHPS, using three pipes to conduct heat from the PPS and the OST to a 52 by 124 centimeter radiator fin, maintained the PPS baseplate temperature below 50 C for all operating conditions. The TEP performance characteristics presented include frequency response, rf output power, thermal performance, and efficiency. Communications characteristics were evaluated by using both video and audio modulated signals. On four occasions, the TEP experienced temporary thermal control system malfunctions. The anomalies were terminated safely, and the problem was investigated because of the potential for TEP damage due to the signficant temperature increases. Safe TEP operating procedures were established.

Smetana, J.↗

Thermal control canister

An apparatus for maintaining a heat dissipating load at a substantially constant temperature, and more particularly, to such an apparatus where in variable conductance heat pipes control the radiating area of a radiator is described.

Ollendorf, S.↗

Depriming of arterial heat pipes: An investigation of CTS thermal excursions

Four thermal excursions of the Transmitter Experiment Package (TEP) were the result of the depriming of the arteries in all three heat pipes in the Variable Conductance Heat Pipe System which cooled the TEP. The determined cause of the depriming of the heat pipes was the formation of bubbles of the nitrogen/helium control gas mixture in the arteries during the thaw portion of a freeze/thaw cycle of the inactive region of the condenser section of the heat pipe. Conditions such as suction freezeout or heat pipe turn-on, which moved these bubbles into the active region of the heat pipe, contributed to the depriming mechanism. Methods for precluding, or reducing the probability of, this type of failure mechanism in future applications of arterial heat pipes are included.

Antoniuk, D.↗