Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “user interaction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

The use of workflows in the design and implementation of complex experiments in macromolecular crystallography

A powerful and easy-to-use workflow environment has been developed at the ESRF for combining experiment control with online data analysis on synchrotron beamlines. This tool provides the possibility of automating complex experiments without the need for expertise in instrumentation control and programming, but rather by accessing defined beamline services. The automation of beam delivery, sample handling and data analysis, together with increasing photon flux, diminishing focal spot size and the appearance of fast-readout detectors on synchrotron beamlines, have changed the way that many macromolecular crystallography experiments are planned and executed. Screening for the best diffracting crystal, or even the best diffracting part of a selected crystal, has been enabled by the development of microfocus beams, precise goniometers and fast-readout detectors that all require rapid feedback from the initial processing of images in order to be effective. All of these advances require the coupling of data feedback to the experimental control system and depend on immediate online data-analysis results during the experiment. To facilitate this, a Data Analysis WorkBench (DAWB) for the flexible creation of complex automated protocols has been developed. Here, example workflows designed and implemented using DAWB are presented for enhanced multi-step crystal characterizations, experiments involving crystal reorientation with kappa goniometers, crystal-burning experiments for empirically determining the radiation sensitivity of a crystal system and the application of mesh scans to find the best location of a crystal to obtain the highest diffraction quality. Beamline users interact with the prepared workflows through a specific brick within the beamline-control GUI MXCuBE.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optimization of tomographic reconstruction workflows on geographically distributed resources

New technological advancements in synchrotron light sources enable data acquisitions at unprecedented levels. This emergent trend affects not only the size of the generated data but also the need for larger computational resources. Although beamline scientists and users have access to local computational resources, these are typically limited and can result in extended execution times. Applications that are based on iterative processing as in tomographic reconstruction methods require high-performance compute clusters for timely analysis of data. Here, time-sensitive analysis and processing of Advanced Photon Source data on geographically distributed resources are focused on. Two main challenges are considered: (i) modeling of the performance of tomographic reconstruction workflows and (ii) transparent execution of these workflows on distributed resources. For the former, three main stages are considered: (i) data transfer between storage and computational resources, (i) wait/queue time of reconstruction jobs at compute resources, and (iii) computation of reconstruction tasks. These performance models allow evaluation and estimation of the execution time of any given iterative tomographic reconstruction workflow that runs on geographically distributed resources. For the latter challenge, a workflow management system is built, which can automate the execution of workflows and minimize the user interaction with the underlying infrastructure. The system utilizes Globus to perform secure and efficient data transfer operations. The proposed models and the workflow management system are evaluated by using three high-performance computing and two storage resources, all of which are geographically distributed. Workflows were created with different computational requirements using two compute-intensive tomographic reconstruction algorithms. Experimental evaluation shows that the proposed models and system can be used for selecting the optimum resources, which in turn can provide up to 3.13× speedup (on experimented resources). Furthermore, the error rates of the models range between 2.1 and 23.3% (considering workflow execution times), where the accuracy of the model estimations increases with higher computational demands in reconstruction tasks.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Review of Visualization Methods for Cyber-Physical Security: Smart Grid Case Study

Cyber-Physical Systems (CPSs) are becoming increasingly complex and interconnected as they attempt to meet the demands of evolving society. As a result, monitoring and maintaining them becomes a more complex and demanding task for control system operators and cyber defenders. While the literature on visualization techniques in the context of cybersecurity is extensive, the same cannot be said for studies on visualization for the security of cyber-physical systems. This paper aims to fill that gap by: 1) defining the main features of a visualizations workflow for security visualizations in cyber-physical systems. The workflow includes the acquisition of cyber and physical data, processing of data, selection, and configuration of both visualization tools and end-user interactions. 2) Providing an overview of cyber-physical security visualization systems, with a focus on smart grids as a case study. Finally, we use the perspectives gained from this analysis to provide insights and directions for future research and design of cyber-physical visualization techniques.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Situated Visualization of Photovoltaic Module Performance for Workforce Development

The rapid growth of the solar energy industry requires advanced educational tools to train the next generation of engineers and technicians. We present a novel system for situated visualization of photovoltaic (PV) module performance, leveraging a combination of PV simulation, sun-sky position, and head-mounted augmented reality (AR). Our system is guided by four principles of development: simplicity, adaptability, collaboration, and maintainability, realized in six components. Users interactively manipulate a physical module's orientation and shading referents with immediate feedback on the module's performance.

augmented reality↗

Solid State Power Substation DC Node Optimization and Controller Hardware-In-The-Loop Demonstration

A solid state power substation (SSPS) node is a microgrid that integrates distributed energy resources and loads and injects/absorbs power to/from the SSPS distribution network. It is an essential building block of a futuristic distribution grid network. This paper presents the development and demonstration of optimization use cases of a SSPS DC node. By adopting multi-layer hierarchical control architecture and developing automatic device identification and dynamic optimization formulation algorithms, the SSPS DC node can perform plug-and-play resource integration and seamless transition of the optimized node operation under on and off grid condition without sophisticated algorithms, control mode changes, and user interactions. Four optimization use cases including economic dispatches with price signal changes, a sudden PV power drop, and a single directional meter and its associated costs with sending power back to the grid, and resiliency under a grid inverter trip condition were demonstrated through the real-time controller hardware-in-the-loop simulation.

Kim, Namwon↗

Multimedia Analysis plus Visual Analytics = Multimedia Analytics

Multimedia analysis has focused on images, video, and to some extent audio and has made progress in single channels excluding text. Visual analytics has focused on the user interaction with data during the analytic process plus the fundamental mathematics and has continued to treat text as did its precursor, information visualization. The general problem we address in this tutorial is the combining of multimedia analysis and visual analytics to deal with multimedia information gathered from different sources, with different goals or objectives, and containing all media types and combinations in common usage.

99 GENERAL AND MISCELLANEOUS↗

GRUMDN: A Multi-Task Model for Predicting Human Patterns-of-Life from Stay Transition Data

Understanding human patterns-of-life (PoL) is essential towards ensuring safe and secure indoor facility environment as well as outdoor urban environment. Prediction of human movement in between places of interest is vital in understanding human PoL. Movement between spaces maybe represented and detected in one of the two forms: 1) trajectories: locations measured at regular time intervals by mobile sensors, bluetooth or GPS sensors; or 2) stay transitions: semantic PoI (points of interest) and stay duration data measurable by eventbased sensors that collect data when a check-in or check-out event is detected. Stay transition data provides a more compressed data format compared to trajectories data, especially in situations with longer stay durations, while preserving the information necessary for PoL analysis. Now as introduced briefly in the paper, our deployed end application (Digital Twin of a facility with non-player characters, besides the interactive user in virtual reality) needed a well-performing and validated AI/ML model for simulating high quality stay transitions behavior. In this study we thus primarily present our findings with developing and validating that model, which is a multi-task neural network for stay transition prediction. The neural network consists of two heads, for corresponding two tasks of stay category prediction and stay duration prediction. We evaluated gated recurrent units and multi-layer perceptrons of varying network sizes for stay category prediction; while mixture density networks, noisy generator-only networks, and generative adversarial networks of varying network sizes for stay duration prediction. We have then evaluated four multi-task models, constructed by combining these specialized models, on their ability to predict stay transition data. We tested our models on datasets from two different cases: 1) a simulation-generated dataset of indoor movement within the HFIR (high flux isotope reactor) nuclear reactor facility at Oak Ridge National Laboratory (ORNL); and 2) the GeoLife human mobility dataset of outdoor urban movement available in literature. Our results indicate that GRUMDN, which combines gated recurrent units (GRU) for stay category prediction task, and mixture density networks (MDN) for stay duration prediction task, did overall outperform other multitask models and the current state-of-the-art.

Gunaratne, Chathika [ORNL] (ORCID:0000000225088745↗

Fast Demand Forecast of Electric Vehicle Charging Stations for Cell Phone Application

This paper describes the core cellphone application algorithm which has been implemented for the prediction of energy consumption at Electric Vehicle (EV) Charging Stations at UCLA. For this interactive user application, the total time of accessing database, processing the data and making the prediction, needs to be within a few seconds. We analyze four relatively fast Machine Learning based time series prediction algorithms for our prediction engine: Historical Average, kNearest Neighbor, Weighted k-Nearest Neighbor, and Lazy Learning. The Nearest Neighbor algorithm (k Nearest Neighbor with k=1) shows better performance and is selected to be the prediction algorithm implemented for the cellphone application. Two applications have been designed on top of the prediction algorithm: one predicts the expected available energy at the station and the other one predicts the expected charging finishing time. The total time, including accessing the database, data processing, and prediction is about one second for both applications.

Majidpour, Mostafa↗

Visual Analytics of Crosstalk in Quantum Hardware

Crosstalk remains a major obstacle to building scalable and fault-tolerant quantum computers. Conventional diagnostic techniques-often based on numerical simulation or statistical modeling-struggle to scale with hardware complexity and offer limited interpretability. In this work, we present a visual analytics framework for diagnosing qubit crosstalk using lightweight, circuit-based models integrated with an interactive user interface. Our approach quantifies correlations between active and idle qubits under parameterized single- and twoqubit operations, enabling detection of both spatial and gateinduced crosstalk. The system incorporates qubit topology and gate performance data to support sector-based exploration and correlation mapping. This tool assists users in identifying correlated error sources, informing qubit placement strategies, and guiding noise-aware circuit design.

Chae, Junghoon [ORNL] (ORCID:0000000206016746)↗

Three-dimensional gravity modeling and focusing inversion using rectangular meshes.

Rectangular grid cells are commonly used for the geophysical modeling of gravity anomalies, owing to their flexibility in constructing complex models. The straightforward handling of cubic cells in gravity inversion algorithms allows for a flexible imposition of model regularization constraints, which are generally essential in the inversion of static potential field data. The first part of this paper provides a review of commonly used expressions for calculating the gravity of a right polygonal prism, both for gravity and gradiometry, where the formulas of Plouff and Forsberg are adapted. The formulas can be cast into general forms practical for implementation. In the second part, a weighting scheme for resolution enhancement at depth is presented. Modelling the earth using highly digitized meshes, depth weighting schemes are typically applied to the model objective functional, subject to minimizing the data misfit. The scheme proposed here involves a non-linear conjugate gradient inversion scheme with a weighting function applied to the non-linear conjugate gradient scheme's gradient vector of the objective functional. The low depth resolution due to the quick decay of the gravity kernel functions is counteracted by suppressing the search directions in the parameter space that would lead to near-surface concentrations of gravity anomalies. Further, a density parameter transformation function enabling the imposition of lower and upper bounding constraints is employed. Using synthetic data from models of varying complexity and a field data set, it is demonstrated that, given an adequate depth weighting function, the gravity inversion in the transform space can recover geologically meaningful models requiring a minimum of prior information and user interaction.

54 ENVIRONMENTAL SCIENCES↗

Software-controlled, highly automated intrafraction prostate motion correction with intrafraction stereographic targeting: System description and clinical results

Purpose: A new system for software-controlled, highly automated correction of intrafraction prostate motion,'' intrafraction stereographic targeting'' (iSGT), is described and evaluated. Methods: At our institute, daily prostate positioning is routinely performed at the start of treatment beam using stereographic targeting (SGT). iSGT was implemented by extension of the SGT software to facilitate fast and accurate intrafraction motion corrections with minimal user interaction. iSGT entails megavoltage (MV) image acquisitions with the first segment of selected IMRT beams, automatic registration of implanted markers, followed by remote couch repositioning to correct for intrafraction motion above a predefined threshold, prior to delivery of the remaining segments. For a group of 120 patients, iSGT with corrections for two nearly lateral beams was evaluated in terms of workload and impact on effective intrafraction displacements in the sagittal plane. Results: SDs of systematic ({Sigma}) and random ({sigma}) displacements relative to the planning CT measured directly after initial SGT setup correction were <0.5 and <0.8 mm, respectively. Without iSGT corrections, effective {Sigma} and {sigma} for the 11-min treatments would increase to {Sigma}{sub eff} < 1.1 mm and {sigma}{sub eff} < 1.2 mm. With the iSGT procedure with an action level of 4 mm, effective positioning errors were reduced to {Sigma}{sub eff} < 0.8 mm and {sigma}{sub eff} < 1.0 mm, with 23.1% of all fractions requiring a correction. Computer simulations demonstrated that with an action level of 2 mm, the errors would have been reduced to {Sigma}{sub eff} < 0.6 mm and {sigma}{sub eff} < 0.7 mm, requiring corrections in 82.4% of the fractions. Because iSGT is highly automated, the extra time added by iSGT is <30 s if a correction is required. Conclusions: Without increasing imaging dose, iSGT successfully reduces intrafraction prostate motion with minimal workload and increase in fraction time. An action level of 2 mm is recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Model generation of coronary artery bifurcations from CTA and single plane angiography

Purpose: To generate accurate and realistic models of coronary artery bifurcations before and after percutaneous coronary intervention (PCI), using information from two image modalities. Because bifurcations are regions where atherosclerotic plaque appears frequently and intervention is more challenging, generation of such realistic models could be of high value to predict the risk of restenosis or thrombosis after stent implantation, and to study geometrical and hemodynamical changes. Methods: Two image modalities have been employed to generate the bifurcation models: computer tomography angiography (CTA) to obtain the 3D trajectory of vessels, and 2D conventional coronary angiography (CCA) to obtain radius information of the vessel lumen, due to its better contrast and image resolution. In addition, CCA can be acquired right before and after the intervention in the operation room; therefore, the combination of CTA and CCA allows the generation of realistic preprocedure and postprocedure models of coronary bifurcations. The method proposed is semiautomatic, based on landmarks manually placed on both image modalities. Results: A comparative study of the models obtained with the proposed method with models manually obtained using only CTA, shows more reliable results when both modalities are used together. The authors show that using preprocedure CTA and postprocedure CCA, realistic postprocedure models can be obtained. Analysis carried out of the Murray's law in all patient bifurcations shows the geometric improvement of PCI in our models, better than using manual models from CTA alone. An experiment using a cardiac phantom also shows the feasibility of the proposed method. Conclusions: The authors have shown that fusion of CTA and CCA is feasible for realistic generation of coronary bifurcation models before and after PCI. The method proposed is efficient, and relies on minimal user interaction, and therefore is of high value to study geometric and hemodynamic changes of treated patients.

60 APPLIED LIFE SCIENCES↗

Real-time x-ray fluoroscopy-based catheter detection and tracking for cardiac electrophysiology interventions

Purpose: X-ray fluoroscopically guided cardiac electrophysiology (EP) procedures are commonly carried out to treat patients with arrhythmias. X-ray images have poor soft tissue contrast and, for this reason, overlay of a three-dimensional (3D) roadmap derived from preprocedural volumetric images can be used to add anatomical information. It is useful to know the position of the catheter electrodes relative to the cardiac anatomy, for example, to record ablation therapy locations during atrial fibrillation therapy. Also, the electrode positions of the coronary sinus (CS) catheter or lasso catheter can be used for road map motion correction.Methods: In this paper, the authors present a novel unified computational framework for image-based catheter detection and tracking without any user interaction. The proposed framework includes fast blob detection, shape-constrained searching and model-based detection. In addition, catheter tracking methods were designed based on the customized catheter models input from the detection method. Three real-time detection and tracking methods are derived from the computational framework to detect or track the three most common types of catheters in EP procedures: the ablation catheter, the CS catheter, and the lasso catheter. Since the proposed methods use the same blob detection method to extract key information from x-ray images, the ablation, CS, and lasso catheters can be detected and tracked simultaneously in real-time.Results: The catheter detection methods were tested on 105 different clinical fluoroscopy sequences taken from 31 clinical procedures. Two-dimensional (2D) detection errors of 0.50 {+-} 0.29, 0.92 {+-} 0.61, and 0.63 {+-} 0.45 mm as well as success rates of 99.4%, 97.2%, and 88.9% were achieved for the CS catheter, ablation catheter, and lasso catheter, respectively. With the tracking method, accuracies were increased to 0.45 {+-} 0.28, 0.64 {+-} 0.37, and 0.53 {+-} 0.38 mm and success rates increased to 100%, 99.2%, and 96.5% for the CS, ablation, and lasso catheters, respectively. Subjective clinical evaluation by three experienced electrophysiologists showed that the detection and tracking results were clinically acceptable.Conclusions: The proposed detection and tracking methods are automatic and can detect and track CS, ablation, and lasso catheters simultaneously and in real-time. The accuracy of the proposed methods is sub-mm and the methods are robust toward low-dose x-ray fluoroscopic images, which are mainly used during EP procedures to maintain low radiation dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-I-02: A Framework to Perform Batch Simulations of Computational Voxel Phantoms to Study Organ Doses in Computed Tomography Using a Commercial Monte Carlo Software Package

Purpose: ImpactMC (CT Imaging, Erlangen, Germany) is a Monte Carlo (MC) software package that offers a GPU enabled, user definable and validated method for 3D dose distribution calculations for radiography and Computed Tomography (CT). ImpactMC, in and of itself, offers limited capabilities to perform batch simulations. The aim of this work was to develop a framework for the batch simulation of absorbed organ dose distributions from CT scans of computational voxel phantoms. Methods: The ICRP 110 adult Reference Male and Reference Female computational voxel phantoms were formatted into compatible input volumes for MC simulations. A Matlab (The MathWorks Inc., Natick, MA) script was written to loop through a user defined set of simulation parameters and 1) generate input files required for the simulation, 2) start the MC simulation, 3) segment the absorbed dose for organs in the simulated dose volume and 4) transfer the organ doses to a database. A demonstration of the framework is made where the glandular breast dose to the adult Reference Female phantom, for a typical Chest CT examination, is investigated. Results: A batch of 48 contiguous simulations was performed with variations in the total collimation and spiral pitch. The demonstration of the framework showed that the glandular dose to the right and left breast will vary depending on the start angle of rotation, total collimation and spiral pitch. Conclusion: The developed framework provides a robust and efficient approach to performing a large number of user defined MC simulations with computational voxel phantoms in CT (minimal user interaction). The resulting organ doses from each simulation can be accessed through a database which greatly increases the ease of analyzing the resulting organ doses. The framework developed in this work provides a valuable resource when investigating different dose optimization strategies in CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-497: Semi-Automated in Vivo Radiochromic Film Dosimetry Using a Novel Image Processing Algorithm

Purpose: To validate an automated image processing algorithm designed to detect the center of radiochromic film used for in vivo film dosimetry against the current gold standard of manual selection. Methods: An image processing algorithm was developed to automatically select the region of interest (ROI) in *.tiff images that contain multiple pieces of radiochromic film (0.5x1.3cm{sup 2}). After a user has linked a calibration file to the processing algorithm and selected a *.tiff file for processing, an ROI is automatically detected for all films by a combination of thresholding and erosion, which removes edges and any additional markings for orientation. Calibration is applied to the mean pixel values from the ROIs and a *.tiff image is output displaying the original image with an overlay of the ROIs and the measured doses. Validation of the algorithm was determined by comparing in vivo dose determined using the current gold standard (manually drawn ROIs) versus automated ROIs for n=420 scanned films. Bland-Altman analysis, paired t-test, and linear regression were performed to demonstrate agreement between the processes. Results: The measured doses ranged from 0.2-886.6cGy. Bland-Altman analysis of the two techniques (automatic minus manual) revealed a bias of -0.28cGy and a 95% confidence interval of (5.5cGy,-6.1cGy). These values demonstrate excellent agreement between the two techniques. Paired t-test results showed no statistical differences between the two techniques, p=0.98. Linear regression with a forced zero intercept demonstrated that Automatic=0.997*Manual, with a Pearson correlation coefficient of 0.999. The minimal differences between the two techniques may be explained by the fact that the hand drawn ROIs were not identical to the automatically selected ones. The average processing time was 6.7seconds in Matlab on an IntelCore2Duo processor. Conclusion: An automated image processing algorithm has been developed and validated, which will help minimize user interaction and processing time of radiochromic film used for in vivo dosimetry.

60 APPLIED LIFE SCIENCES↗

Multiattribute probabilistic prostate elastic registration (MAPPER): Application to fusion of ultrasound and magnetic resonance imaging

Purpose: Transrectal ultrasound (TRUS)-guided needle biopsy is the current gold standard for prostate cancer diagnosis. However, up to 40% of prostate cancer lesions appears isoechoic on TRUS. Hence, TRUS-guided biopsy has a high false negative rate for prostate cancer diagnosis. Magnetic resonance imaging (MRI) is better able to distinguish prostate cancer from benign tissue. However, MRI-guided biopsy requires special equipment and training and a longer procedure time. MRI-TRUS fusion, where MRI is acquired preoperatively and then aligned to TRUS, allows for advantages of both modalities to be leveraged during biopsy. MRI-TRUS-guided biopsy increases the yield of cancer positive biopsies. In this work, the authors present multiattribute probabilistic postate elastic registration (MAPPER) to align prostate MRI and TRUS imagery. Methods: MAPPER involves (1) segmenting the prostate on MRI, (2) calculating a multiattribute probabilistic map of prostate location on TRUS, and (3) maximizing overlap between the prostate segmentation on MRI and the multiattribute probabilistic map on TRUS, thereby driving registration of MRI onto TRUS. MAPPER represents a significant advancement over the current state-of-the-art as it requires no user interaction during the biopsy procedure by leveraging texture and spatial information to determine the prostate location on TRUS. Although MAPPER requires manual interaction to segment the prostate on MRI, this step is performed prior to biopsy and will not substantially increase biopsy procedure time. Results: MAPPER was evaluated on 13 patient studies from two independent datasets—Dataset 1 has 6 studies acquired with a side-firing TRUS probe and a 1.5 T pelvic phased-array coil MRI; Dataset 2 has 7 studies acquired with a volumetric end-firing TRUS probe and a 3.0 T endorectal coil MRI. MAPPER has a root-mean-square error (RMSE) for expert selected fiducials of 3.36 ± 1.10 mm for Dataset 1 and 3.14 ± 0.75 mm for Dataset 2. State-of-the-art MRI-TRUS fusion methods report RMSE of 3.06–2.07 mm. Conclusions: MAPPER aligns MRI and TRUS imagery without manual intervention ensuring efficient, reproducible registration. MAPPER has a similar RMSE to state-of-the-art methods that require manual intervention.

60 APPLIED LIFE SCIENCES↗

Noninvasive differential diagnosis of dental periapical lesions in cone-beam CT scans

Purpose: This paper proposes a novel application of computer-aided diagnosis (CAD) to an everyday clinical dental challenge: the noninvasive differential diagnosis of periapical lesions between periapical cysts and granulomas. A histological biopsy is the most reliable method currently available for this differential diagnosis; however, this invasive procedure prevents the lesions from healing noninvasively despite a report that they may heal without surgical treatment. A CAD using cone-beam computed tomography (CBCT) offers an alternative noninvasive diagnostic tool which helps to avoid potentially unnecessary surgery and to investigate the unknown healing process and rate for the lesions. Methods: The proposed semiautomatic solution combines graph-based random walks segmentation with machine learning-based boosted classifiers and offers a robust clinical tool with minimal user interaction. As part of this CAD framework, the authors provide two novel technical contributions: (1) probabilistic extension of the random walks segmentation with likelihood ratio test and (2) LDA-AdaBoost: a new integration of weighted linear discriminant analysis to AdaBoost. Results: A dataset of 28 CBCT scans is used to validate the approach and compare it with other popular segmentation and classification methods. The results show the effectiveness of the proposed method with 94.1% correct classification rate and an improvement of the performance by comparison with the Simon’s state-of-the-art method by 17.6%. The authors also compare classification performances with two independent ground-truth sets from the histopathology and CBCT diagnoses provided by endodontic experts. Conclusions: Experimental results of the authors show that the proposed CAD system behaves in clearer agreement with the CBCT ground-truth than with histopathology, supporting the Simon’s conjecture that CBCT diagnosis can be as accurate as histopathology for differentiating the periapical lesions.

60 APPLIED LIFE SCIENCES↗

SU-C-304-02: Robust and Efficient Process for Acceptance Testing of Varian TrueBeam Linacs Using An Electronic Portal Imaging Device (EPID)

Purpose: The purpose of this project was to develop a process that utilizes the onboard kV and MV electronic portal imaging devices (EPIDs) to perform rapid acceptance testing (AT) of linacs in order to improve efficiency and standardize AT equipment and processes. Methods: In this study a Varian TrueBeam linac equipped with an amorphous silicon based EPID (aSi1000) was used. The conventional set of AT tests and tolerances was used as a baseline guide, and a novel methodology was developed to perform as many tests as possible using EPID exclusively. The developer mode on Varian TrueBeam linac was used to automate the process. In the current AT process there are about 45 tests that call for customer demos. Many of the geometric tests such as jaw alignment and MLC positioning are performed with highly manual methods, such as using graph paper. The goal of the new methodology was to achieve quantitative testing while reducing variability in data acquisition, analysis and interpretation of the results. The developed process was validated on two machines at two different institutions. Results: At least 25 of the 45 (56%) tests which required customer demo can be streamlined and performed using EPIDs. More than half of the AT tests can be fully automated using the developer mode, while others still require some user interaction. Overall, the preliminary data shows that EPID-based linac AT can be performed in less than a day, compared to 2–3 days using conventional methods. Conclusions: Our preliminary results show that performance of onboard imagers is quite suitable for both geometric and dosimetric testing of TrueBeam systems. A standardized AT process can tremendously improve efficiency, and minimize the variability related to third party quality assurance (QA) equipment and the available onsite expertise. Research funding provided by Varian Medical Systems. Dr. Sasa Mutic receives compensation for providing patient safety training services from Varian Medical Systems, the sponsor of this study.

07 ISOTOPE AND RADIATION SOURCES↗