Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “usability studies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Analysis of RF Surface Loss in a Planar 2D Qubit

The Josephson junction and shunt capacitor form a transmon qubit, which is the cornerstone of modern quantum computing platforms. For reliable quantum computing, it is important how long a qubit can remain in a superposition of quantum states, which is determined by the coherence time (T1). The coherence time of a qubit effectively sets the "lifetime" of usable quantum information, determining how long quantum computations can be performed before errors occur and information is lost. There are several sources of decoherence in transmon qubits, but the predominant one is generally considered to be dielectric losses in the natural oxide layer formed on the surface of the superconductor. In this paper, we present a numerical study of microwave surface losses in planar superconducting antennas of different transmon qubit designs. An asymptotic method for estimating the energy participation ratio in ultrathin films of nanometer scales is proposed, and estimates are given for the limits of achievable minimum RF losses depending on the electrical properties of the surface oxide and the interface of the qubit with the substrate material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A new generation of direct X-ray detectors for medical and synchrotron imaging applications

Abstract Large-area X-ray imaging is one of the most widely used imaging modalities that spans several scientific and technological fields. Currently, the direct X-ray conversion materials that are being commercially used for large-area (> 8 cm × 4 cm without tiling) flat panel applications, such as amorphous selenium (a-Se), have usable sensitivities of up to only 30 keV. Although there have been many promising candidates (such as polycrystalline HgI 2 and CdTe), none of the semiconductors were able to assuage the requirement for high energy (> 40 keV) large-area X-ray imaging applications due to inadequate cost, manufacturability, and long-term performance metrics. In this study, we successfully demonstrate the potential of the hybrid Methylammonium lead iodide (MAPbI 3 ) perovskite-based semiconductor detectors in satisfying all the requirements for its successful commercialization in synchrotron and medical imaging. This new generation of hybrid detectors demonstrates low dark current under electric fields needed for high sensitivity X-ray imaging applications. The detectors have a linear response to X-ray energy and applied bias, no polarization effects at a moderate bias, and signal stability over long usage durations. Also, these detectors have demonstrated a stable detection response under BNL’s National Synchrotron Light Source II (NSLS-II) 70 keV monochromatic synchrotron beamline.

47 OTHER INSTRUMENTATION↗

DeePMD-kit v2: A software package for deep potential models

DeePMD-kit is a powerful open-source software package that facilitates molecular dynamics simulations using machine learning potentials known as Deep Potential (DP) models. This package, which was released in 2017, has been widely used in the fields of physics, chemistry, biology, and material science for studying atomistic systems. The current version of DeePMD-kit offers numerous advanced features, such as DeepPot-SE, attention-based and hybrid descriptors, the ability to fit tensile properties, type embedding, model deviation, DP-range correction, DP long range, graphics processing unit support for customized operators, model compression, non-von Neumann molecular dynamics, and improved usability, including documentation, compiled binary packages, graphical user interfaces, and application programming interfaces. This article presents an overview of the current major version of the DeePMD-kit package, highlighting its features and technical details. Additionally, this article presents a comprehensive procedure for conducting molecular dynamics as a representative application, benchmarks the accuracy and efficiency of different models, and discusses ongoing developments.

97 MATHEMATICS AND COMPUTING↗

Port of New York and New Jersey Drayage Electrification Analysis

The National Renewable Energy Laboratory (NREL) evaluated the potential for drayage electrification in the Port of New York and New Jersey (PoNYNJ), with a focus on operators: Harbor Freight Transport (HF), Safeway Trucking (SWT), and International Motor Freight Inc (IMF). This report summarizes the data collection and electrification evaluation of all three drayage operators, includes detailed operational data, and identifies the performance requirements for battery electric tractors (BETs) and corresponding infrastructure operated within the context of PoNYNJ drayage operation. This report also details a methodology to evaluate opportunities, strategies, and challenges associated with future expansions of BETs in meeting PANYNJ emissions goals. The Port Authority has established a goal of achieving Net Zero carbon emissions by 2050 across all facilities, including from tenant and stakeholder sources such as drayage trucks. NREL used real-world performance data collected on the three PoNYNJ drayage operations, along with modeling and analysis tools to compare BET to diesel trucks. From March to July 2021, NREL collected 1Hz vehicle and engine data from 46 drayage trucks at the three operators totaling nearly 121,000 miles of operation, providing enough information to assess vehicle operations for electrification potential. A Future Automotive Systems Technology Simulator (FASTSim) electric truck powertrain model was validated using PoNYNJ data and scenarios were run to evaluate drayage truck electrification requirements over the real-world cycles. The first scenario examined BET viability with minimal changes to existing operations. This assumes the trucks charge when stopped for two hours or longer, have a functional battery size of 375 kWh, and can charge at 270 kilowatts (kW) average which are the specification of the commercially available Freightliner eCascadia. The second scenario looked at what operational, charging infrastructure, and BET technology changes would be needed to fully electrify. Finally, detailed analysis was run on charging rate structure to understand operational costs to the fleets. The studied drayage trucks averaged 5.1 MPG, spent roughly 9% of their energy at idle, and drove an average of 140 miles per day with a maximum daily distance of 573 miles. The FASTSim model results indicate a comparable BET would use 417 kWh of energy per day on average accounting for cargo weight, which is close to the full usable capacity of the eCascadia currently available on the market. Based on the daily average operating data, partial fleet electrification is possible with current technology. However, some specific days of operation would require over 1,600 kWh of energy due to longer distances traveled by the trucks and more intense operation. Trucks used for long distance and intense operation cannot be readily electrified with current technology without operational changes. Full adoption of BETs could reduce CO 2 emissions from these fleets by roughly 75% today, eliminating 76 metric tons of CO 2 (MTCO 2 ) per vehicle each year, which equates to 24,100 MTCO 2 per year for all three operators. Commercially available direct current fast chargers (DCFC) have charge rates up to 350 kW. Based on the average daily modeled energy use for each operator, current industrial rate structures, and the assumption of 350 kW peak charging, full drayage electrification would increase electricity consumption. In addition, peak demand usage would increase with unmanaged charging along with cost of electricity having a direct impact on cost per mile for electric vehicles. The resulting cost per mile for BETs along with comparable cost per mile for conventional diesel trucks are also examined at $\$$4.00 per gallon of diesel. It will be important for PANYNJ and the drayage operators within the PoNYNJ to consider these load impacts to their existing electrical infrastructure and devise operational strategies that avoid coincident charging of vehicles to mitigate demand charges. Despite these electricity cost increases, savings from reductions in diesel consumption will help offset the costs of this increased electricity consumption. However, prices of both electricity and diesel are subject to change based on various factors meaning the realized savings will vary over time. This shows BETs could be cost-competitive on an energy cost per mile basis for all scenarios while diesel is above $\$$3.00/gal. Further, if diesel prices dropped to the 15-year low of $2.33/gal, it would still be cost competitive to operate the EVs with electricity costs of 16.3 ¢/kWh or less.

33 ADVANCED PROPULSION SYSTEMS↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating the Effectiveness of an Ultrasonic Acoustic Deterrent in Reducing Bat Fatalities at Wind Energy Facilities

This project was designed to use thermal video cameras and fatality monitoring to evaluate the effectiveness of an ultrasonic acoustic deterrent (UAD) on bat activity and mortality, respectively. Our goals were to redesign the UAD device and installation infrastructure, determine the placement on wind turbines to optimize safety, compatibility and functionality, and to compare the mortality among the following conditions: Control (deterrents off and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Deterrent (deterrents on and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Curtailment (deterrents off and turbines feathered up to 5/ m/s), and combination (deterrents on and turbines feathered up to 5 m/s). The project was divided into a Feasibility Study and Comparative Study. The objectives for the Feasibility Study were to develop an installation strategy, redesign a previous iteration of a UAD to improve performance and weatherization, and test the effectiveness of the deterrents on bat activity. The Feasibility Study was intended to work out potential issues using a relatively small number of devices prior to manufacturing and installing numerous devices for a larger-scale comparative study. The division of the project into these separate studies was based on previous experience and the challenges of assessing the capabilities of an untested UAD. During the initial development and manufacturing of the UAD, NRG Systems decided to use a piezoelectric transducer rather than an electrostatic transducer, which was used by a previous device (i.e. Deaton UAD). NRG Systems conducted lab testing (i.e., IP67 or Ingress Protection) to ensure no water or dust ingress. In addition, shock/drop trials and variations in temperature exposure were conducted as part of the reliability testing. NRG Systems also developed a communications system to allow for continuous performance monitoring of the UADs. For the Feasibility Study, we installed 6 UADs on each of 2 Gamesa G90 2-MW wind turbines (Turbine 14 and 8) at the South Chestnut Wind Energy Facility, Pennsylvania and monitored activity under control and treatment (i.e. Deterrent) conditions using thermal video monitoring. There are two major sources of variation in bat activity (beyond the anticipated treatment effect): 1) environment around the turbines might inherently favor more activity at one than the other; 2) weather conditions on any given night or within season difference (e.g., migration later during the study period) might favor more activity on some nights than on other nights. Because we could only monitor two turbines on any night, we sought to control the potential influences of these two sources by alternating the turbine on which deterrents were activated each night. If there were no loss of data due to technical failures, this design would result in an equal number of deterrent and control nights at each turbine through the monitoring period, balancing the effects of both sources of variation. We compared the time bats spent and the number of events that occurred in overlapping cameras FOV as an indicator of risk, since 80% of the overlapping FOV of the cameras was in the RSA. Equipment failures, majority due to lightning, resulted in only 17 nights with useable data, with unbalanced treatment assignment within turbines and uneven distribution of treatment assignment throughout the observational period. This resulted in a confounding of treatment assignment and seasonal change. Deterrent treatment was measured at Turbine 14 on only 2 of the first 8 usable nights (spanning the period from 8/18-9/17), whereas 6 times on Turbine 8. From 9/18-927, deterrent was on at Turbine 14 on 6 of the remaining 10 nights, and 4 on Turbine 8. We recorded a total of 1,057 bats and observed a reduction in number of events and duration of events at the UAD-activated turbine when it was Turbine 14. When Turbine 8 had the UAD activated, we observed no difference in number or duration of events. Variation between turbines is not unusual and can cause issues when study designs have no true replication, i.e., multiple turbines per treatment. Within-turbine differences suggested a trend for reduced activity when UADs were activated, particularly for Turbine 14. These results may be caused by the overall higher bat activity at Turbine 8 and confounding of treatment assignment and seasonal trends. We mapped 58 bat events in 3-dimensional space (3D), 30 and 28 events during control and treatment conditions, respectively. We observed bats crossing the rotor plane under both control and treatment conditions and observed a total of 40 confirmed or near-collisions (i.e., target close to blade but no visual confirmation of a strike) out of a total of 1,491 medium and high confidence bat observations (880 control, 611 at treatment). Twice as many collisions/possible collisions were observed during control conditions. Given the challenges with the equipment and potential confounding of the data (i.e., different activity levels at the two wind turbines), we were unable to determine whether this initial turbine placement and orientation was optimal. Given no new information on how best to install the devices, we elected to use the same placement and orientation for the comparative study. For the Comparative Study, the objectives were to investigate the relative mortality rates among 4 treatments. We searched the area within 90 m of each turbine daily to recover the highest number of fresh fatalities possible. We were unable to detect a clear reduction in mortality from deterrents alone for any individual species. Surprisingly, mortality rate of the eastern red bat (Lasiurus borealis) was estimated to be 1.3–4.2 times as much when turbines were operating normally and UADs were on than when UADs were off. Reduction in mortality of all bat species combined due to curtailment of turbines was estimated to be between 0%–38%. This effect was nullified when, in addition to curtailment, UADs were on, with 95% confidence interval ranging from a 45% reduction to a 36% increase in mortality. This was likely due to the large proportion of eastern red bats in the total carcass population. Mortality of all low-frequency echolocating bats combined (i.e. hoary bat [L. cinereus], big brown bat [Eptesicus fuscus], silver-haired bat [Lasionycteris noctivagans]) relative to control was lower when curtailed (95% CI: 0%–74%), but the addition of UADs had no detectable effect (95%CI: 13%–79%). The combined treatment reduced mortality in silver-haired bats relative to control by 11%–99%, compared to curtailment (81% reduction–67% increase) or deterrent (82% reduction–67% increase) alone. Because silver-haired bats comprised a large proportion of low-frequency calling bats found during this study, a similar effect was seen for that group. The higher mortality observed for eastern red bats at UAD compared to control could have been caused by several factors, such as the effective range of the UAD, particularly at higher frequencies, behavior, positioning of the devices on the nacelle, or a combination of these. We used 3D thermal videography to compare control and UAD bat behavior from two turbines using a total of 203 3D bat-tracks across 34 nights. We recorded a similar number of bat-tracks between treatment groups, with 51% and 49% for control and UAD, respectively. Due to potential differences in bat behavior around spinning vs stationary turbine blades, we examined UAD effectiveness separately for non-operating turbines (feathered below cut-in speed of 3.5 m/s) and operating (normal operation above wind speed of 3.5 m/s). We found a higher proportion of bat-tracks at operating turbines (82%) compared to non-operating turbines (18%), although this does not account for overall time turbines were operating versus not. At non-operating turbines the UAD appears to be effective at reducing the amount of time, flight length, and number of passes through the rotor plane, compared to control. In addition, we found bats approached turbines similarly between control and treatment turbines, with 61% of control and 63% of UAD bat-tracks originating leeward of the hub. In contrast, at operating turbines, we saw little change in bat behavior in response to UADs. For example, we found an increase in the average duration of bat-tracks between non-operating and operating turbines for UAD but at control turbines we found average duration decreased once turbines became operational. Both control and UAD had a high proportion of bat-tracks that crossed the rotor plane (i.e., collision risk) originate from the windward side when turbines were operational 65% to 92%, respectively. Given that the UAD devices closest to the blades were orientated parallel to the blades, its possible bats were not exposed to the signal until they were close to the turbine blades, as suggested by the slightly higher mean duration within 5 meters of the blades for UAD turbines. Future research should consider concentrating UAD intensity on the areas of risk (i.e. blades) with enough buffer to allow bats to react to the sound before entering the rotor-swept area (RSA). In addition, investigating the potential of installing UAD units windward of the turbine blades (e.g. a hub-mounted UAD), particularly since even under control conditions, a relatively high proportion (65%) of crosses through the blade plane originated windward. 3D thermal videography provided valuable information on future testing strategies (e.g. device placement, UAD orientation) to improve UAD effectiveness when bats are at risk (i.e., operating wind turbines). Across the entire project we experienced issues with the operation and communication with the UADs. Most of the issues occurred during the Feasibility Study and were resolved prior to the Comparability Study. Additional challenges surfaced during the Comparability Study but were remedied immediately and are thought to have little impact on the results. We had logistical constraints at the project that limited our ability use traditional methods in our camera calibration. Several calibrations showed inaccurate scales, which may have been related to inadequate spatial coverage of “points” in the camera calibration volume. Because we were using actual video recordings of bats at a wind turbine, the behavior of bats could have concentrated “points” in specific areas of the turbine (i.e. leeward of nacelle), and limited “points” in other areas, resulting in camera calibration issues. We have plans to address these inconsistencies and improving the software and related methodologies by early 2020.

17 WIND ENERGY↗

Laboratory evaluation of cyclic underground hydrogen storage in the Temblor sandstone of the San Joaquin Basin, California

Underground Hydrogen Storage (UHS) in depleted oil and gas reservoirs could provide a cost-effective solution to balance seasonal fluctuations in renewable energy generation. However, data and knowledge on UHS at subsurface conditions are limited so it is difficult to estimate how effective this type of storage could be. In this study, we perform high pressure experiment to measure the effectiveness of cyclic hydrogen (H 2 ) storage in a specimen of Temblor sandstone retrieved from the San Joaquin Basin of California. Our experiment mimics reservoir pressure conditions to measure H 2 -brine relative permeability and fluid-rock interactions over the course of ten charging and discharging cycles. Initial gas breakthrough occurred at 15 % to 25 % H2 saturation in the specimen with 3 % NaCl brine as the resident fluid. Continuing injecting to 4 pore volumes (PV) of H 2 yielded an asymptotic H 2 saturation of 38 % to 41 %, a level often referred to as the irreducible gas saturation based on two-phase flow. The boundary condition in this study mimics the near wellbore region, which experiences bi-directional H 2 flow. This bi-directional flow led to evaporative drying of the specimen resulting in 94 % H 2 saturation at the end of 10th cycle. This indicates that cyclic flow and evaporative drying can lead to more efficient reservoir storage where a larger fraction of the reservoir porosity is usable to store H 2 . The produced gas stream consisted of H 2 mixed with 8 % to 22 % H 2 O, indicating formation dry-out by evaporation. Meanwhile, produced water chemistry indicated calcite and silicate dissolution, with calcite sourced from fossil fragments. This led to a loss of cementation and weakened the rock sample. Combined, our results indicate dry-out, compaction, increased H 2 saturation, rock weakening, and permeability loss during cyclic UHS. Overall, we anticipate that the combined effects should lead to higher than anticipated UHS storage efficiency per volume of sandstone reservoir rock.

08 HYDROGEN↗

Liquid-phase mega-electron-volt ultrafast electron diffraction

The conversion of light into usable chemical and mechanical energy is pivotal to several biological and chemical processes, many of which occur in solution. To understand the structure–function relationships mediating these processes, a technique with high spatial and temporal resolutions is required. Here, we report on the design and commissioning of a liquid-phase mega-electron-volt (MeV) ultrafast electron diffraction instrument for the study of structural dynamics in solution. Limitations posed by the shallow penetration depth of electrons and the resulting information loss due to multiple scattering and the technical challenge of delivering liquids to vacuum were overcome through the use of MeV electrons and a gas-accelerated thin liquid sheet jet. To demonstrate the capabilities of this instrument, the structure of water and its network were resolved up to the 3rd hydration shell with a spatial resolution of 0.6 Å; preliminary time-resolved experiments demonstrated a temporal resolution of 200 fs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Techno-Economic Implications of Electrical Machine Scaling for Wave Energy Converters

The sizing of an electrical machine for a Wave Energy Converter (WEC) can have a substantial impact on the overall sizing, cost, and rating of the device. An electrical generator is typically part of the power take-off system, which is the mechanism by which the energy absorbed by the prime mover is transformed into usable electrical energy. For practically all WECs, the rate of change of actuation is predominantly determined by the wave resource (i.e., the wave height and frequency), and devices will see a sinusoidal varying velocity according to the wave conditions. The same can then be said for both directly and indirectly coupled power take-offs with electrical generators. This techno-economic study investigates electrical machine scaling and associated cost implications through core machine design theory, manufacturer data, supporting literature, and the Reference Model Project sponsored by the U.S. Department of Energy. The Reference Model Project was a partnered effort to develop open-source marine energy point designs as reference models to benchmark marine energy technology performance and costs, methods for design and analysis of marine energy technologies, estimations for capital costs, operational costs, and levelized cost of energy. The results from this study show torque is directly related to (1) the physical size of the machine required to increase the air-gap sheer stresses, (2)the amount of active material, (3) the support structure, (4) bearing size and rating, and (5) offshore cable rating, all of which have a significant effect on overall system costs in terms of both capital and operational expenditures. This paper aims to be a critical benchmark in helping determine an "optimal" nameplate rating for wave energy devices and their associated power take-offs. With an optimized rating and sizing process, WEC costs can be reduced and overall performance can be improved.

cables↗

Baseline Fuel Fabrication Facility

PRO-RR is the research reactor focused program element of the broader Proliferation Resistance Optimization program (PRO-X) under the National Nuclear Safety Administration (NNSA) in the U.S. Department of Energy (DOE). PRO-X provides a framework for integrating proliferation resistance in nuclear system designs to minimize weapons usable nuclear materials (WUNM) production and diversion pathways while optimizing systems performance for peaceful use missions. PRO-RR applies the PRO-X mission objectives to research reactor system design. This document serves as one of the foundational documents for the PRO-RR-Fuel System Design technical team by documenting a baseline fuel fabrication facility to be used for further optimization studies. The PRO-RR-Fuel System Design technical team consists of subject matter experts from Argonne National Laboratory (Argonne) and Savannah River National Laboratory (SRNL). In order to develop specific strategies for fuel fabrication facilities to optimize proliferation resistance, performance, and safety, a baseline fuel fabrication facility design basis was developed. Having a baseline design basis allows for the qualitative and quantitative comparison of design choices in the optimization process. This report describes the baseline fuel fabrication facility and general optimization strategy. Chapter 2 describes the fuel system selected for examination, the fabrication process used as the baseline, a description of the model developed to track uranium utilization, and a generic floorplan of the fabrication facility. Chapter 3 describes the overarching optimization strategy that could be implemented for a fabrication facility.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Expanded Intercomparison of Nuclear Data Libraries Using Jupiter and Jupiter High-240 Experiments

There is a limited availability of plutonium experiments with sensitivity to lead in the ICSBEP (International Handbook of Evaluated Criticality Safety Benchmark Experiments) Handbook. The Jupiter and Jupiter High-240 experiments were performed at the National Criticality Experiments Research Center as a collaborative effort between Los Alamos National Laboratory and the Japan Atomic Energy Agency to assess lead void coefficients in a plutonium-lead system containing weapons- and reactor-grade plutonium, respectively. Concurrent with benchmark development, an intercomparison of calculations using different nuclear data libraries has been performed to assess the usability of the experimental data for nuclear data adjustment in a “softer-that-fast” neutron energy spectrum. Eigenvalue calculations using MCNP with the ENDF/B-VIII.0 and TENDL-2021 nuclear data libraries calculate closest to the benchmark values for Jupiter. Calculations using JENDL-5 and ENDF/B-VIII.1 match best with the Jupiter High-240 values. Lead void worth calculations using the various nuclear data libraries are all within 3σ of their respective measured values. Perturbation studies between ENDF/B-VIII.0 and ENDF/B-VIII.1 demonstrate an approximate increase in calculated eigenvalues for the Jupiter series experiments by ~240 pcm for plutonium (mostly 239 Pu) and ~120 pcm for lead accompanied by a decrease contributed by ~113 pcm for copper and ~13 pcm for stainless steel. Nuclear data sensitivities and uncertainties investigated using Whisper show slightly lower sensitivity to scatter than a lead-reflected plutonium sphere but greater sensitivity to neutron capture. The sensitivities between Jupiter and Jupiter High-240 for lead are very similar for both ENDF/B-VIII.0 and ENDF/B-VIII.1 nuclear data. These benchmarks are more sensitive to neutron capture in lead than other plutonium benchmark experiments and would be useful for both lead and 240 Pu validation. In conclusion, with the high degree of compensating effects between copper, lead, and plutonium cross sections, additional isolated Pb-Pu and Cu-Pu benchmarks would be beneficial in improving these nuclear data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Isolation and conversion of electrolyte components into a value-added product

The overall objective of this work was to develop a process for effectively (i) recycling the electrolyte components from the end-of-life batteries and reduce the environmental hazard, (ii) understand the fundamental differences between pristine and recycled electrolyte components, (iii) electrochemically and analytically evaluate the recycled electrolyte components and (iv) establish deviations from the pristine electrolyte, and effectively separation of value-added product. We focused on determining scaling up the electrolyte recovery process by distillation of end-of-life batteries to get yield enough to use it for electrolyte formulation of reuse in the battery cell. The used cells from the ORNL battery manufacture facility (BMF)as well as received from the industry partner, Austin Elements Inc., was scaled to 10 used multilayered pouch cells in each batch of distillation and systematically separated and identified the electrolyte components of the used cells with FTIR and NMR studies. We were able to recovery 10g of solvent mass from the used pouch cells. NMR spectroscopy showed that the solvent was pure EMC,DMC and the sample was used to make a new battery cell. The end-of-life battery, it was noted that some cells were visually drier than the other cells and were more advanced in aged. In that case, even though the same distillation conditions were utilized, no usable mass of electrolyte solvent was recovered. It is expected that most of the solvent was decomposed during the battery charge-discharge cycling. The solid salt residue was separated by chemical and water treatment processes. Components of resulting solid product was analyzed by XRD and XPS measurements. The solid products are very much related to the salts used in the electrolyte solution.

25 ENERGY STORAGE↗

Isolation and Conversion of Electrolyte Components into a Value-Added Product

The overall objective of this work was to develop a process for effectively (i) recycling the electrolyte components from the end-of-life batteries and reduce the environmental hazard, (ii) understand the fundamental differences between pristine and recycled electrolyte components, (iii) electrochemically and analytically evaluate the recycled electrolyte components and (iv) establish deviations from the pristine electrolyte, and effectively separation of value-added product. We focused on determining scaling up the electrolyte recovery process by distillation of end-of-life batteries to get yield enough to use it for electrolyte formulation of reuse in the battery cell. The used cells from the ORNL battery manufacture facility (BMF) as well as received from the industry partner, Austin Elements Inc., was scaled to 10 used multilayered pouch cells in each batch of distillation and systematically separated and identified the electrolyte components of the used cells with FTIR and NMR studies. We were able to recovery 10g of solvent mass from the used pouch cells. NMR spectroscopy showed that the solvent was pure EMC, DMC and the sample was used to make a new battery cell. The end-of-life battery, it was noted that some cells were visually drier than the other cells and were more advanced in aged. In that case, even though the same distillation conditions were utilized, no usable mass of electrolyte solvent was recovered. It is expected that most of the solvent was decomposed during the battery charge-discharge cycling. The solid salt residue was separated by chemical and water treatment processes. Components of resulting solid product was analyzed by XRD and XPS measurements. The solid products are very much related to the salts used in the electrolyte solution.

25 ENERGY STORAGE↗

Heuristic Evaluation Methods Applied to a Predictive Maintenance Chatbot

The need for an accessible iterative approach for evaluating prospective artificial intelligence (AI)/ML based technologies in the nuclear industry is needed, given the nature of algorithms and rapid advancements. This paper explores existing heuristic design principles for user-centered design and evaluates them based on their relevancy and usefulness for evaluating AI/ ML based technologies. Researchers at the Idaho National Laboratory (INL) have developed a machine learning software application called VIsualization for PrEdictive maintenance Recommendation (VIPER), which is used to help users understand and engage with the tool to learn more about work orders, data used, predictive maintenance, and machine learning (ML) algorithms. Early user research studies used to access VIPER’s technology readiness level have occurred; however, there is room for further improvement of the software through heuristic evaluations along with other methods and user testing. This work describes the applicability of heuristic evaluation methods and cognitive walkthroughs to help ensure human readiness for prospective AI/ ML based applications, using VIPER as a candidate use case. This work supports industry in ensuring that prospective AI/ML based technologies are usable and useful for plant personnel at nuclear power plants, ultimately leading to their safe, reliable, and efficient use.

99 - GENERAL AND MISCELLANEOUS↗

Heuristic Evaluation Methods Applied to a Predictive Maintenance Chatbot

The need for an accessible iterative approach for evaluating prospective artificial intelligence (AI)/ML based technologies in the nuclear industry is needed, given the nature of algorithms and rapid advancements. This paper explores existing heuristic design principles for user-centered design and evaluates them based on their relevancy and usefulness for evaluating AI/ ML based technologies. Researchers at the Idaho National Laboratory (INL) have developed a machine learning software application called VIsualization for PrEdictive maintenance Recommendation (VIPER), which is used to help users understand and engage with the tool to learn more about work orders, data used, predictive maintenance, and machine learning (ML) algorithms. Early user research studies used to access VIPER?s technology readiness level have occurred; however, there is room for further improvement of the software through heuristic evaluations along with other methods and user testing. This work describes the applicability of heuristic evaluation methods and cognitive walkthroughs to help ensure human readiness for prospective AI/ ML based applications, using VIPER as a candidate use case. This work supports industry in ensuring that prospective AI/ML based technologies are usable and useful for plant personnel at nuclear power plants, ultimately leading to their safe, reliable, and efficient use. PowerPoint for conference that was reviewed in PRS and LRS PRS/CON-25-05379 and INL/CON-25-82946

99 - GENERAL AND MISCELLANEOUS↗

Component-Level Inverse Design of Transmon Qubits Using Neural Networks

Designing a superconducting qubit to realize specific Hamiltonian parameters typically requires iterating through a time and compute-intensive forward loop in which the designer chooses a layout geometry, simulates it, extracts circuit parameters such as capacitances, and refines the geometry. We study the inverse version of this task using a neural-network workflow that maps target Hamiltonian parameters directly to component-level layout parameters, which we subsequently demonstrate on a planar transmon layout. During training, we pair the inverse model with a frozen forward surrogate model and evaluate the loss in Hamiltonian space rather than in layout-parameter space. In validation against a conventional EM solver, 97% of generated designs produce usable geometries, and the inverse-plus-surrogate pipeline reaches mean percent errors of 0.73% for qubit frequency and 1.58% for anharmonicity, comparable to or below the fabrication and simulation-to-measurement uncertainty expected for academic-process transmon devices of this type. A single pipeline query takes ~60 ms on CPU, versus ~2 min for a conventional EM capacitance extraction on the same hardware, a speedup of approximately 2,000x. Batching minimizes the AI model inference overhead, reducing the runtime to 3.1 microseconds per sample on CPU and 2.6 microseconds per sample on GPU at a batch size of 2048, resulting in speedups of 3.9 x 10^7 and 4.6 x 10^7, respectively, relative to a single conventional CPU EM extraction. Our results indicate that component-level inverse design usefully extends and complements conventional EM simulation, including for small datasets on the order of 1,000 samples.

Seidel, Olivia [Fermilab; Texas U., Arlington]↗

Safety and effectiveness of a non-electric infant warmer for hypothermia in Rwanda: A cluster-randomized stepped-wedge trial

Background: Neonatal hypothermia is a common source of morbidity and mortality in low resource settings. We developed the Dream Warmer, a low cost, re-usable non-electric infant warmer to prevent and treat hypothermia. Methods: We conducted a cluster-randomized stepped-wedge trial. The primary aim was to assess the effect on overall euthermia rates of introducing the warmer compared to standard of care in rural Rwandan hospitals. The secondary aims were to assess effects of warmer introduction on mortality, as well as the safety and feasibility of the warmer. Ten district hospitals participated in the study from November 19th 2019 to July 15th 2020. Patients were eligible to use the warmer if they were 1) hypothermic (temp < 36·5 °C) or 2) or at risk of hypothermia (weight < 2·5 kg or estimated post menstrual age < 35 weeks) when Kangaroo Mother Care was not available. An encounter was defined as the data from an individual infant on a single day. Trial of a Non Electric Infant Warmer for Prevention and Treatment of Hypothermia in Rwanda [NCT03890211]. Findings: Over the study period, 3179 patients were enrolled across the ten neonatal wards, yielding 12,748 encounters; 464 unique infants used the warmer 892 times, 79% eligible due to hypothermia. Because of limited study nurse resources, the warmer was used in only 18% of eligible encounters. Despite this low rate of warmer use, the rate of euthermia rose from 51% (95% CI 50–52%) of encounters pre-intervention to 67% (66–68%) post-intervention; p < 0·0001. Among the encounters in which the warmer was used, only 11% (9–13%) remained hypothermic. While mortality rates pre- and post-intervention did not change, mortality rate among those who used the warmer was significantly lower than among those who did not (0·9% vs 2·8%, p = 0·01). Use of the warmer did not affect hyperthermia rates. There were no safety concerns or instances of incorrect warmer use. Interpretation: Introduction of the warmer increased rates of euthermia with no associated safety concerns.

60 APPLIED LIFE SCIENCES↗

Assessing cathode–electrolyte interphases in batteries

The cathode-electrolyte interphase plays a pivotal role in determining the usable capacity and cycling stability of electrochemical cells, yet it is overshadowed by its counterpart, the solid-electrolyte interphase. This is primarily due to the prevalence of side reactions, particularly at low potentials on the negative electrode, especially in state-of-the-art Li-ion batteries where the charge cutoff voltage is limited. However, as the quest for high-energy battery technologies intensifies, there is a pressing need to advance the study of cathode-electrolyte interphase properties. Here, we present a comprehensive approach to analyse the cathode-electrolyte interphase in battery systems. We underscore the importance of employing model cathode materials and coin cell protocols to establish baseline performance. Additionally, we delve into the factors behind the inconsistent and occasionally controversial findings related to the cathode-electrolyte interphase. In conclusion, we also address the challenges and opportunities in characterizing and simulating the cathode-electrolyte interphase, offering potential solutions to enhance its relevance to real-world applications.

25 ENERGY STORAGE↗