Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “transformer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Phase transformation of hydrous ringwoodite to the lower-mantle phases and the formation of dense hydrous silica

In order to understand the effects of H 2 O on the mineral phases forming under the pressure-temperature conditions of the lower mantle, we have conducted laser-heated diamond-anvil cell experiments on hydrous ringwoodite (Mg 2 SiO 4 with 1.1wt% H 2 O) at pressures between 29 and 59 GPa and temperatures between 1200 and 2400 K. Our experimental results show that hydrous ringwoodite (hRw) converts to crystalline dense hydrous silica, stishovite (Stv) or CaCl 2 -type SiO 2 (mStv), containing 1 wt% H 2 O together with Brd and MgO at the pressure-temperature conditions expected for shallow lower-mantle depths between approximately 660 to 1600 km. Considering lack of sign for melting in our experiments, our preferred interpretation of the observation is that Brd partially breaks down to dense hydrous silica and periclase (Pc), forming Brd + Pc + Stv mineralogy. Our experiments may provide an explanation for the enigmatic coexistence of Stv and Fp inclusions in lower-mantle diamonds

58 GEOSCIENCES↗

Design, Deployment, and Characterization of the World’s First Flexible Large Power Transformer

GE Research and its partner Prolec GE have designed, built and deployed in the field the world’s first flexible power transformer. The flexible power transformer is a transmission class 3-phase autotransformer configurable in impedance and in voltage which allows it to serve as a universal spare for multiple units in a given fleet. However, the key innovation in this new concept is the online adjustable leakage impedance which allows the transformer to change its impedance without interrupting the transmission line operation. The flexible power transformer can be designed with up to three low voltage transmission class ratings and up to 12 impedance values changeable both online and offline. This report provides an overview of the design, manufacturing, testing, and commissioning of the 165kV, 60MVA prototype built including the results of the field performance validation tests. The prototype was specified in collaboration with Cooperative Energy, the utility host. It was designed and tested in the factory according to IEEE standard C57.12.00 and followed all protocols for transportation, installation, and commissioning of a power transformer. In addition to the prototype, a flexible protection system capable of automatically adjusting its settings upon the transformer impedance was also developed and deployed in the for testing and validation. On September 3, 2021 the prototype was energized in Cooperative Energy’s substation in Columbia, Mississippi to become the world’s first flexible power transformer in operation. Its performances and impact on the grid operation were demonstrated through different field tests. Results obtained confirm that the impedance of the flexible transformer can be varied under load through its full range, from 4.3% to 9.3%, without adverse impacts on the line operation, the protection system, the transformer stability and health condition. Results also proved that the flexible transformer is very effective in controlling power transfer through the line or load sharing between units operating in parallel. Indeed, it was proven that higher impedances decrease the thruput power of the transformer while lower impedances increase it. Up to 26MW was controllable on a line loading of 45MVA. It was also possible to demonstrate that the variation of the transformer impedance has no effect on the circulating current between units in parallel, except a minor transient during the impedance change. It was also proven that the flexible protection relay can update its protection settings automatically when the impedance change was detected. The prototype has operated continuously for more than 12 months now with a peak load exceeding 50MVA corresponding to >80% of its ONAN power rating. No alarm, trip or sign of failure has been reported by the utility. In addition to the development and deployment of the flexible transformer prototype, investigations were carried out on new nanodielectric fluids to replace the mineral oil used in power transformers with the goal of reducing their footprint and weight. The key parameters that were targeted for improvement included the breakdown voltage to reduce clearances between windings and tank hence the footprint; viscosity and thermal conductivity to increase the cooling efficiency and therefore to reduce the winding material. Several nanodielectric mixtures with mineral oil including with alumina (Al2O3), titania (TiO2) and Borum Nitrate (BN) with different surfactants have been analyzed and tested. Unfortunately, despite encouraging results no nanofluid candidate has been found viable to replace mineral oil. With the formulations tested, breakdown voltages are generally similar to mineral oil at lower particle contents and worse at higher particle contents. Viscosity appreciably increased at particles concertation over 2 wt% and thermal conductivity increased slightly at 5wt% and appears to be 10-15% higher at 10 wt% particle content. It is recommended to continue investigations to find solutions that can help increase the power density of future flexible power transformers. Flexible power transformers can significantly help the future power grid by providing more flexibility and resiliency. Indeed, by providing voltage and impedance flexibility, flexible power transformers reduce the need for multiple spares, hence inventory costs for utilities. With their online controllable impedance, they can provide support to the grid and help manage short-circuit currents, power flow, line congestion, and grid stability which will become more important with higher penetrations of intermittent renewable resources. During the field validation tests, it was demonstrated that up to 26MW was controllable on a line loading of 45MVA when the transformer impedance was varied from its minimum to its maximum range. Also, with the impedance range, the short-circuit currents could be reduced by up to 38% at the load side of the transformer. With its controllable impedance, flexible transformers can be used in future strategies of grid resilience to help better prepare the grid to face forecasted severe events including storms, heat waves and contingencies. The flexible power transformers can also find role in other applications including high voltage transmission cables such as offshore wind farms where solutions for energizing the cables and managing the reactive power are of critical importance. The designed flexible power transformer is now fully validated and ready for commercialization. Further analysis on the benefits of flexible power transformers for grid stability and short-circuit management including current limiting capability, reclosure and line restoration, control of inrush current, sizing of flexible AC components (FACTS) would help its rapid adoption by the industry.

24 POWER TRANSMISSION AND DISTRIBUTION↗

TRANSENSOR: Transformer Real-time Assessment INtelligent System with Embedded Network of Sensors and Optical Readout. Final Report

Utilities across the world are wrestling with evolving market dynamics, population growth and climate change. Distributed Energy Resources (DERs) such as solar photovoltaics, distributed generators and energy storage systems are becoming important parts of the U.S. energy mix. These factors are driving an increasing need for low-cost grid asset monitoring. Aside from being costly, traditional utility monitoring systems are not sufficiently robust and do not provide real-time visibility into the condition of grid assets such as transformers. Lack of accurate real-time measurements on performance has resulted in the use of lagging indicators, such as oil sample analysis. To address this need, an innovative embedded optical sensing technology, Transformer Real-time Assessment Intelligent System (TRANSENSOR) was developed, validated and demonstrated in this project. To date, TRANSENSOR has focused on transformers but is extendable to other grid assets. In addition to the technology being embedded into new transformers during manufacturing, a retrofit configuration that can be installed on existing transformers in the field was also developed. It is anticipated that the ability to retrofit existing transformers will help accelerate adoption of the underlying TRANSENSOR technology. Phase 1 of the project focused on laboratory development and qualification of the technology. Following iterations and exploration of relevant optical sensing modalities and multiplexed configurations of interest for the transformer environment, an effective candidate configuration was agreed upon, down-selected and custom-designed for embedding into General Electric (GE) network transformers. Two new GE 500 kilovolt ampere (kVA), 27 kilovolt (kV) distribution network transformers were built with embedded fiber-optic (FO) sensors and successfully qualified per industry standards at GE’s Shreveport, Louisiana facility during Phase 1 of the project. Following the successful completion of Phase 1, the team proceeded to Phase 2, which focused on a field demonstration of the technology. Over Phase 2, the first new GE transformer built with embedded fiber-optic sensors was installed in an above-ground cage and connected to the grid at Con Edison’s Astoria facility. A second transformer equipped with TRANSENSOR was installed in an underground vault. Additionally, an older (1982 year model) GE transformer in an above-ground cage was retrofitted with fiber- optic sensors and reconnected to the grid at ConEd’s facility. Analysis of data acquired from the sensors showed interesting correlations with transformer loading. Additionally, key events such as transformer low-voltage network connection, primary-side energizing, and a pressure loss event from an oil sampling were detected by the TRANSENSOR system. Online data processing/feature extraction algorithms for the second transformer in the underground vault detected key features and event alerts that were transmitted through a wireless 4G connection. The remote deployment concept showed promising results with data collection running for a total of 8 months across the three (3) GE transformers instrumented for the Phase 2 field demonstration. This sets the stage well for further development and commercialization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Organic matter transformations are disconnected between surface water and the hyporheic zone

Abstract. Biochemical transformations of organic matter (OM) are a primary driver of river corridor biogeochemistry, thereby modulating ecosystem processes at local to global scales. OM transformations are driven by diverse biotic and abiotic processes, but we lack knowledge of how the diversity of those processes varies across river corridors and across surface and subsurface components of river corridors. To fill this gap we quantified the number of putative biotic and abiotic transformations of organic molecules across diverse river corridors using ultra-high-resolution mass spectrometry. The number of unique transformations is used here as a proxy for the diversity of biochemical processes underlying observed profiles of organic molecules. For this, we use public data spanning the contiguous United States (ConUS) from the Worldwide Hydrobiogeochemical Observation Network for Dynamic River Systems (WHONDRS) consortium. Our results show that surface water OM had more biotic and abiotic transformations than OM from shallow hyporheic zone sediments (1–3 cm depth). We observed substantially more biotic than abiotic transformations, and the numbers of biotic and abiotic transformations were highly correlated with each other. We found no relationship between the number of transformations in surface water and sediments and no meaningful relationships with latitude, longitude, or climate. We also found that the composition of transformations in sediments was not linked with transformation composition in adjacent surface waters. We infer that OM transformations represented in surface water are an integrated signal of diverse processes occurring throughout the upstream catchment. In contrast, OM transformations in sediments likely reflect a narrower range of processes within the sampled volume. This indicates decoupling between the processes influencing surface water and sediment OM, despite the potential for hydrologic exchange to homogenize OM. We infer that the processes influencing OM transformations and the scales at which they operate diverge between surface water and sediments.

58 GEOSCIENCES↗

Broadband Characterization and Circuit Model Development of Transmission-Scale Transformers

This report describes broadband measurements of transmission-scale transformers typical in the electric power grid. This work was performed as part of the EMP Resilient Grid LDRD project at Sandia National Laboratories to generate circuit models that can be used for high-altitude electromagnetic pulse (HEMP) coupling simulations and response predictions. The objective of the work was to obtain characterization data of substation yard equipment across a frequency range relevant to HEMP. Vector network analyzer measurements up to 100 MHz were performed on two power transformers at ABB-Hitachi and a single ITEC potential transformer. Custom cable breakouts were designed to interface with the transformer terminals and provide ground connections to the chassis at the base of the transformer bushings. The three-phase terminals of the power transformers were measured as a common mode impedance using a parallel resistive splitter, and the single-phase terminals of the potential transformer were measured directly. A vector fitting algorithm was used to empirically fit circuit models to the resulting two-port networks and input impedances of the measured objects. Simplified circuit representations of the input impedances were also generated to assess the degree of precision needed for high-altitude electromagnetic pulse response predictions, which were performed in Sandia's XYCE circuit simulator platform. HEMP coupling simulations using the transformer models showed significant reduction in the voltage peak and broadening in the pulse width seen at the power transformer compared to the traveling wave voltage. This indicated the importance of the load condition when defining the coupled insult in an electric power substation. Simplified circuit models showed a similar voltage at the transformer with a smoothed waveform. The presence of potential transformers in the simulation did not significantly change the simulated voltage at the power transformer. Single-port input impedance models were also developed to define load conditions when transfer characteristics were not necessary.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mn(II)-induced phase transformation of Mn(IV) oxide in seawater

Manganese (Mn) oxides are key components of oceanic and lacustrine Mn nodules and influence metal cycling through oxidation and adsorption processes. Layered Mn oxides (LMOs) are the most common minerals in these nodules and the immediate products of microbially mediated Mn(II) oxidation by O 2 . LMOs can transform into tunneled Mn oxides (TMOs), Mn oxyhydroxides (MnOOH), or Mn(II,III) phase (Mn 3 O 4 ). LMOs often concur with Mn(II) in the environment and the adsorption and oxidation of Mn(II) by LMOs can greatly promote the transformation of LMOs to those phases. However, the Mn(II)-promoted transformation of LMOs in seawater—rich in various cations (300 mM Na + , 10 mM K + , 50 mM Ca 2+ , and 10 mM Mg 2+ ) remains poorly understood. We examined the transformation of δ-MnO 2 in artificial seawater (pH 8.2) under anoxic conditions with the Mn(II)/MnO 2 ratio (r) ranging from 0.08 to 3.83. To assess the effect of ionic strength (IS), parallel experiments were conducted in a mixed 530 mM NaCl and 10 mM KCl solution (having seawater ionic strength but without Ca 2+ and Mg 2+ ) and in 100 mM NaCl solution as a control. At low r (0.08), δ-MnO 2 transformed into triclinic birnessite and a 4 × 4 TMO in 100 mM NaCl solution, which, however, was suppressed in seawater due to strong interactions of Ca 2+ /Mg 2+ with δ-MnO 2 . In the mixed 530 mM NaCl and 10 mM KCl solution (the same ionic strength as of seawater), the transformation occurred extensively but the products had lower crystallinity compared to in 100 mM NaCl solution. At the high Mn(II)/MnO 2 ratios (0.5 ≤ r ≤ 3.83), δ-MnO 2 transformed extensively into MnOOH phases and hausmannite (Mn 3 O 4 ) in 100 mM NaCl solution. The seawater suppressed the transformation, but the suppression became weaker with increasing Mn(II)/MnO 2 ratio. For example, the transformation was completely suppressed at r = 0.5 but essentially negligible at r = 3.83. The suppression at these high Mn(II)/MnO 2 ratios was mainly ascribed to the influence of Ca 2+ and Mg 2+ rather than of the high IS, and the weaker suppression at the higher Mn(II)/MnO 2 ratio suggests stronger competition of Mn(II) with Ca 2+ /Mg 2+ for interacting with δ-MnO 2 . Moreover, the composition and crystallinity of the transformation products (i.e., the relative abundance of MnOOH (α, β, and γ) and Mn 3 O 4 ) were influenced by both the high ionic strength and the presence of Ca 2+ and Mg 2+ . Therefore, even though Ca 2+ and Mg 2+ concentrations are much lower than Na + in seawater, their impacts on the transformation are dominant. Our study explains why MnOOH phases, hausmannite, and TMOs are less common than LMOs in oceanic environments, partially because seawater chemistry suppresses their formation. LMOs are the most reactive for metal adsorption and oxidation among all Mn oxides. Thus, the high stability of LMOs in an oceanic environment confers the high impacts of Mn oxides on metal cycling in the ocean.

Divalent manganese↗

A survey of techniques for optimizing transformer inference

Recent years have seen a phenomenal rise in the performance and applications of transformer neural networks. The family of transformer networks, including Bidirectional Encoder Representations from Transformer (BERT), Generative Pretrained Transformer (GPT) and Vision Transformer (ViT), have shown their effectiveness across Natural Language Processing (NLP) and Computer Vision (CV) domains. Transformer-based networks such as ChatGPT have impacted the lives of common men. However, the quest for high predictive performance has led to an exponential increase in transformers' memory and compute footprint. Researchers have proposed techniques to optimize transformer inference at all levels of abstraction. Further, this paper presents a comprehensive survey of techniques for optimizing the inference phase of transformer networks. We survey techniques such as knowledge distillation, pruning, quantization, neural architecture search and lightweight network design at the algorithmic level. We further review hardware-level optimization techniques and the design of novel hardware accelerators for transformers. We summarize the quantitative results on the number of parameters/FLOPs and the accuracy of several models/techniques to showcase the tradeoff exercised by them. We also outline future directions in this rapidly evolving field of research. We believe that this survey will educate both novice and seasoned researchers and also spark a plethora of research efforts in this field.

97 MATHEMATICS AND COMPUTING↗

A Novel Gene Stacking Method in Plant Transformation Utilizing Split Selectable Markers

Gene stacking, the process of introducing multiple genes into a single plant to enhance desired traits, is essential for plant genetic improvement through both conventional breeding and genetic transformation. In general, transformation-based gene stacking can be achieved through either co-transformation to simultaneously introduce multiple genes or sequential multi-round transformation. While co-transformation is generally faster and more efficient than sequential multi-round transformation, it often requires two selectable marker genes, which confer resistance to antibiotics, for selecting transgenic events. However, in most cases, there is only one best selectable marker gene for a specific plant species or genotype. Also, it is harder to optimize the concentrations of two antibiotics for co-transformation than using one antibiotic for selecting transgenic events. To overcome this challenge, we recently developed an innovative split selectable marker system for plant co-transformation, allowing the use of one selectable marker gene to select transgenic events. This method involves constructing two binary vectors, each carrying a subset of genes of interest and a partial fragment of the selectable marker gene, which is connected to a partial intein fragment. Following Agrobacterium -mediated co-transformation, plants harboring both binary vectors are selected using a single antibiotic, such as kanamycin. This split-marker system can be used to co-transform multiple genes into both herbaceous and woody plants, accelerating genetic improvement of polygenic traits or integrative improvement of multiple traits to simultaneously increase crop yield and quality.

59 BASIC BIOLOGICAL SCIENCES↗

Effect of bacterial cell addition on Fe(III) reduction and soil organic matter transformation in a farmland soil

The coupled biogeochemical processes of Fe(III) reduction and organic matter transformation profoundly impact terrestrial carbon cycling. However, little is known about the microbial role in soil organic matter (SOM) transformation during Fe(III) bio-reduction. Here we investigated the bio-reduction behavior of a black farmland soil and corresponding SOM transformation under circumneutral and anoxic conditions. A model dissimilatory Fe reducing bacterium, Geobacter sulfurreducens, was added in either live or dead form in order to enhance Fe(III) reduction in soil and to evaluate the accompanying transformation of SOM. The progress of Fe reduction was monitored and SOM transformation was characterized by various spectroscopy methods. Results showed that addition of either dead or live G. sulfurreducens cells increased the Fe(III) reduction rate and extent. Without cell addition, SOM transformation was insignificant within 13 days of incubation, only with some consumption of aliphatic/protein compounds, apparently due to their higher bio-degradability. Addition of dead or live cells resulted in more drastic SOM transformation, but through different mechanisms. With dead cell amendment, cell necromass and debris stimulated the activity of indigenous soil microbes by serving as extra carbon/energy sources. During Fe(III) reduction, the aliphatic/protein compounds were preferentially consumed by indigenous microbial communities, similar to the treatment without cell addition but with a greater extent of consumption. In comparison, addition of live G. sulfurreducens cells stimulated degradation of less bioavailable compounds, including more saturated and higher molecular weight SOM. It is possible that fast depletion of labile SOM by live G. sulfurreducens cells favored utilization of less bioavailable molecules (such as those with more aromatic structures) by the originally dormant species in native microbial community, suggesting an active role of live Fe(III)-reducing bacteria in affecting SOM transformation. In addition, fast assimilation of microbial related carbon, such as aromatic proteins and microbial byproducts, into SOM pools was also observed. Overall, our results suggest that addition of Fe(III)-reducing bacteria to a native soil can enhance Fe(III) reduction and accelerate the turnover of SOM through various mechanisms. The study provides new insights into coupled Fe(III) reduction and SOM transformation, as well as the “priming effect” of SOM using microbial cells as substrate.

54 ENVIRONMENTAL SCIENCES↗