Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tomographic imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

SU-G-JeP4-15: Feasibility Study of Tumor Monitoring Technique Using Prompt Gamma Rays During Antiproton Therapy

Purpose: The purpose of this study is to suggest a tumor monitoring technique using prompt gamma rays emitted during the reaction between an antiproton and a boron particle, and to verify the increase of the therapeutic effectiveness of the antiproton boron fusion therapy using Monte Carlo simulation code. Methods: We acquired the percentage depth dose of the antiproton beam from a water phantom with and without three boron uptake regions (region A, B, and C) using F6 tally of MCNPX. The tomographic image was reconstructed using prompt gamma ray events from the reaction between the antiproton and boron during the treatment from 32 projections (reconstruction algorithm: MLEM). For the image reconstruction, we were performed using a 80 × 80 pixel matrix with a pixel size of 5 mm. The energy window was set as a 10 % energy window. Results: The prompt gamma ray peak for imaging was observed at 719 keV in the energy spectrum using the F8 tally fuction (energy deposition tally) of the MCNPX code. The tomographic image shows that the boron uptake regions were successfully identified from the simulation results. In terms of the receiver operating characteristic curve analysis, the area under the curve values were 0.647 (region A), 0.679 (region B), and 0.632 (region C). The SNR values increased as the tumor diameter increased. The CNR indicated the relative signal intensity within different regions. The CNR values also increased as the different of BURs diamter increased. Conclusion: We confirmed the feasibility of tumor monitoring during the antiproton therapy as well as the superior therapeutic effect of the antiproton boron fusion therapy. This result can be beneficial for the development of a more accurate particle therapy.

60 APPLIED LIFE SCIENCES↗

Image-based model of the spectrin cytoskeleton for red blood cell simulation

We simulate deformable red blood cells in the microcirculation using the immersed boundary method with a cytoskeletal model that incorporates structural details revealed by tomographic images. The elasticity of red blood cells is known to be supplied by both their lipid bilayer membranes, which resist bending and local changes in area, and their cytoskeletons, which resist in-plane shear. The cytoskeleton consists of spectrin tetramers that are tethered to the lipid bilayer by ankyrin and by actin-based junctional complexes. We model the cytoskeleton as a random geometric graph, with nodes corresponding to junctional complexes and with edges corresponding to spectrin tetramers such that the edge lengths are given by the end-to-end distances between nodes. The statistical properties of this graph are based on distributions gathered from three-dimensional tomographic images of the cytoskeleton by a segmentation algorithm. We show that the elastic response of our model cytoskeleton, in which the spectrin polymers are treated as entropic springs, is in good agreement with the experimentally measured shear modulus. By simulating red blood cells in flow with the immersed boundary method, we compare this discrete cytoskeletal model to an existing continuum model and predict the extent to which dynamic spectrin network connectivity can protect against failure in the case of a red cell subjected to an applied strain. As a result, the methods presented here could form the basis of disease- and patient-specific computational studies of hereditary diseases affecting the red cell cytoskeleton.

59 BASIC BIOLOGICAL SCIENCES↗

Development of a Beam Hardening Correction Method for a microCT Scanner Prototype

The radiographic projections acquired with a microCT were simulated and then corrected for beam hardening effects using the linearized signal to equivalent thickness (LSET) method. This procedure requires a calibration signal for each pixel obtained from a set of images with filters of increasing thickness. The projections are corrected by converting the signal to an equivalent thickness using interpolation over the calibration images. The method was validated using simulated projections of different phantoms. Two calibration sets were simulated using aluminum and water filters of thicknesses ranging from 0 to 5 mm and from 0 to 50 mm, respectively. A simulation of the phantoms' projections using a monoenergetic beam was also obtained to establish the relative intensity on the tomographic images when no cupping artifacts are present. Comparison between corrected and uncorrected tomographic images shows that the LSET method effectively corrects the cupping artifact. Streaking artifacts correction with the LSET method shows better results than with the traditional water correction method. Results are independent of the two calibration materials used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of tomographic particle image velocimetry to complex (dusty) plasmas

Over the past decade, particle image velocimetry (PIV) techniques have been used to obtain detailed measurements of the thermal and transport properties of weakly-coupled dusty plasmas. This paper reports on the application of an extension of these techniques, tomographic PIV (tom-PIV), which provides an instantaneous volumetric measurement of the particle transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TMDs and GPDs at a future Electron-Ion Collider

With two options studied at Brookhaven National Lab and Jefferson Laboratory the U.S., an Electron-Ion Collider (EIC) of energy √s=20-100 GeV was under design. Furthermore, the recent 2015 US Nuclear Science Long-Range Planning effort included a future EIC as a recommendation for future construction. The EIC will be unique in colliding polarised electrons off polarised protons and light nuclei, providing the spin degrees of freedom essential to pursue its physics program driven by spin structure, multi-dimensional tomographic images of protons and nuclei, and discovery of the role of collective effects of gluons in nuclei. The foreseen luminosity of the EIC, coupled with its energy variability and reach, will allow unprecedented three-dimensional imaging of the gluon and sea quark distributions, via both TMDs and GPDs, and to explore correlations amongst them. Its hermetic detection capability of correlated fragments promises to similar allow for precise tomographic images of the quark-gluon landscape in nuclei, transcending from light few-body nuclei to the heaviest nuclei, and could uncover how the TMD and GPD landscape changes when gluons display an anticipated collective behavior at the higher energies.

43 PARTICLE ACCELERATORS↗

Application of tomographic particle image velocimetry to studies of transport in complex (dusty) plasma

Over the past twelve years, two-dimensional and stereoscopic particle image velocimetry (PIV) techniques have been used to obtain detailed measurements of the thermal and transport properties of the microparticle component of dusty plasma systems. This letter reports on an extension of these techniques to obtain a volumetric, three-dimensional velocity vector measurement using tomographic PIV. Initial measurements using the tomographic PIV diagnostic are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Breast Cancer Risk Estimation Using Parenchymal Texture Analysis in Digital Breast Tomosynthesis

Mammographic parenchymal texture has been shown to correlate with genetic markers of developing breast cancer. Digital breast tomosynthesis (DBT) is a novel x-ray imaging technique in which tomographic images of the breast are reconstructed from multiple source projections acquired at different angles of the x-ray tube. Compared to digital mammography (DM), DBT eliminates breast tissue overlap, offering superior parenchymal tissue visualization. We hypothesize that texture analysis in DBT could potentially provide a better assessment of parenchymal texture and ultimately result in more accurate assessment of breast cancer risk. As a first step towards validating this hypothesis, we investigated the association between DBT parenchymal texture and breast percent density (PD), a known breast cancer risk factor, and compared it to DM. Bilateral DBT and DM images from 71 women participating in a breast cancer screening trial were analyzed. Filtered-backprojection was used to reconstruct DBT tomographic planes in 1 mm increments with 0.22 mm in-plane resolution. Corresponding DM images were acquired at 0.1 mm pixel resolution. Retroareolar regions of interest (ROIs) equivalent to 2.5 cm{sup 3} were segmented from the DBT images and corresponding 2.5 cm{sup 2} ROIs were segmented from the DM images. Breast PD was mammographically estimated using the Cumulus scale. Overall, DBT texture features demonstrated a stronger correlation than DM to PD. The Pearson correlation coefficients for DBT were r = 0.40 (p<0.001) for contrast and r = -0.52 (p<0.001) for homogeneity; the corresponding DM correlations were r = 0.26 (p = 0.002) and r = -0.33 (p<0.001). Multiple linear regression of the texture features versus breast PD also demonstrated significantly stronger associations in DBT (R{sup 2} = 0.39) compared to DM (R{sup 2} = 0.33). We attribute these observations to the superior parenchymal tissue visualization in DBT. Our study is the first to perform DBT texture analysis in a screening population of women, showing that DBT could potentially provide better breast cancer risk assessment in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigation of Helical Tomotherapy for Partial-Breast Irradiation of Prone-Positioned Patients

Purpose: To investigate whether helical tomotherapy can provide conformal, uniform target-dose coverage for partial-breast irradiation (PBI) of patients positioned prone while achieving organ-at-risk sparing compliant with National Surgical Adjuvant Breast and Bowel Project (NSABP) B-39/Radiation Therapy Oncology Group (RTOG) 0413 guidelines; and to report our initial experience with the delivery of prone-breast PBI treatments using tomotherapy. Methods and Materials: For our pilot study, we generated helical tomotherapy plans upon the images of 10 prone-positioned patients previously treated using conventional techniques. We also generated plans for 4 left-breast prone-positioned PBI patients who were treated using helical tomotherapy, and recalculated the planned sinograms upon the pretreatment megavoltage computed tomographic images. Of the planning target volume (PTV), 95% was prescribed to receive 38.5 Gy, administered twice daily for 5 days. Results: For our pilot study, on average the maximum point dose to the PTV was 41.3 Gy, and 99% or more of the PTV received 90% or more of the prescribed dose. RTOG 0413 dose-volume histogram objectives were fulfilled for all organs at risk except the contralateral breast, which received a maximum point dose as high as 3.2 Gy in 1 case. For the prospective prone-positioned tomotherapy PBI plans, all objectives were met except the contralateral-breast maximum dose, which was 3.7 Gy on average. Dose calculation using the planned sinogram upon the pretreatment megavoltage computed tomographic images indicated consistency with the planned dose distributions. Conclusions: Helical tomotherapy can provide conformal and uniform target-dose coverage simultaneous with adequate sparing of critical structures; in this study only the contralateral breast dose exceeded RTOG 0413 guidelines. Dosimetric results for our 4 prospective patient cases were consistent with those for our 10-case pilot study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Identification of Shielding Material Configurations Using NMIS Imaging

The Nuclear Materials Identification System (NMIS) uses fast neutron tomographic imaging to nonintrusively examine the interior structure of shielded objects. The pixel values in such images represent the attenuation coefficients of the time and directionally tagged fast neutrons from a deuterium-tritium (DT) neutron generator. The reconstruction techniques use either a filtered back projection or a maximum likelihood expectation maximization algorithm. As a first test of the capabilities of these reconstruction techniques to correctly identify individual parts inside of an object, fast neutron imaging was used to identify the regions of shielding surrounding a depleted uranium casting from a library of possible parts. The shielding consisted of multiple regions of common materials such as steel, lead, aluminum, and polyethylene. First, the full object was imaged, and then each of the individual parts was imaged. Several additional parts that were not present in the original object were also imaged to form a library. The individual parts were compared to the full object, and the correct ones were identified using three different methods. These methods included a visual match, an iterative fit of each part, and a mathematical test comparing the sum of squared errors. The successful results demonstrate an initial application of matching. This suggests that it should be possible to implement more sophisticated matching techniques using automated pixel-by-pixel comparison methods in the future.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nucleon Form Factors experiments with 12 GeV CEBAF

A number of precision form factor experiments at high momentum transfer will be performed with the 11 GeV electron beam of CEBAF. We review the approved proposals and the conceptual schemes of several new suggestions. Form factor data will serve as a major input for the construction of a tomographic image of the nucleon.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design of a portable optical emission tomography system for microwave induced compact plasma for visible to near-infrared emission lines

A new non-invasive diagnostic system is developed for Microwave Induced Plasma (MIP) to reconstruct tomographic images of a 2D emission profile. A compact MIP system has wide application in industry as well as research application such as thrusters for space propulsion, high current ion beams, and creation of negative ions for heating of fusion plasma. Emission profile depends on two crucial parameters, namely, the electron temperature and density (over the entire spatial extent) of the plasma system. Emission tomography provides basic understanding of plasmas and it is very useful to monitor internal structure of plasma phenomena without disturbing its actual processes. This paper presents development of a compact, modular, and versatile Optical Emission Tomography (OET) tool for a cylindrical, magnetically confined MIP system. It has eight slit-hole cameras and each consisting of a complementary metal–oxide–semiconductor linear image sensor for light detection. The optical noise is reduced by using aspheric lens and interference band-pass filters in each camera. The entire cylindrical plasma can be scanned with automated sliding ring mechanism arranged in fan-beam data collection geometry. The design of the camera includes a unique possibility to incorporate different filters to get the particular wavelength light from the plasma. This OET system includes selected band-pass filters for particular argon emission 750 nm, 772 nm, and 811 nm lines and hydrogen emission H{sub α} (656 nm) and H{sub β} (486 nm) lines. Convolution back projection algorithm is used to obtain the tomographic images of plasma emission line. The paper mainly focuses on (a) design of OET system in detail and (b) study of emission profile for 750 nm argon emission lines to validate the system design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Prototype Gamma Tomosynthesis System for Molecular Breast Imaging

We are developing an improved gamma camera for molecular breast imaging (MBI) that allows tomographic imaging and improved signal-to-noise over conventional planar methods. We have built a novel gamma camera for MBI that utilizes limited angle tomography, similar to x-ray tomosynthesis, to generate images with depth information and improved signal-to-noise. A unique feature of the gamma tomosynthesis system is a variable-angle slant hole (VASH) collimator. This collimator allows the camera to remain flush against the compression paddle during the tomographic acquisition, which achieves high spatial resolution and simplified detector motion. We constructed a VASH collimator from a stack of tungsten sheets, each sheet containing a matrix of holes created by photo-etching. With the holes of the sheets aligned, a parallel-hole collimator is created; shearing the sheets creates a variable angle slant hole collimator. The shearing is controlled by a motorized mechanism. The collimator was mounted on a commercial MBI camera and projection data were acquired of a set of capillary tube line sources over a 50° range of angles. The projection data were reconstructed using the iterative MLEM method. Results demonstrated the ability of the system to resolve in the depth dimension, and spatial resolution matched expected values. We conclude that the proposed gamma tomosynthesis system has the potential to provide improved signal-to-noise over conventional MBI methods and allow a reduction in the administered radioactivity and patient dose.

Gilland, David↗

Tomographic FLEET with a wedge array for multi-point three-component velocimetry

Femtosecond laser electronic excitation tagging (FLEET) velocimetry is an important diagnostic technique for seedless velocimetry measurements particularly in supersonic and hypersonic flows. Typical FLEET measurements feature a single laser line and camera system to achieve one-component velocimetry along a line, although some multiple-spot and multiple-component configurations have been demonstrated. In this work, tomographic imaging is used to track the three-dimensional location of many FLEET spots. A quadscope is used to combine four unique views onto a single high-speed image intensifier and camera. Tomographic reconstructions of the FLEET emission are analyzed for three-component velocimetry from multiple FLEET spots. Glass wedges are used to create many (nine) closely spaced FLEET spots with less than 10% transmission losses. These developments lead to a significant improvement in the dimensionality and spatial coverage of a FLEET instrument with some increases in experimental complexity and data processing. Multiple-point three-component FLEET velocimetry is demonstrated in an underexpanded jet.

47 OTHER INSTRUMENTATION↗

Efficient gradient field generation providing a multi-dimensional arbitrary shifted field-free point for magnetic particle imaging

Magnetic Particle Imaging (MPI) is a tomographic imaging modality capable to visualize tracers using magnetic fields. A high magnetic gradient strength is mandatory, to achieve a reasonable image quality. Therefore, a power optimization of the coil configuration is essential. In order to realize a multi-dimensional efficient gradient field generator, the following improvements compared to conventionally used Maxwell coil configurations are proposed: (i) curved rectangular coils, (ii) interleaved coils, and (iii) multi-layered coils. Combining these adaptions results in total power reduction of three orders of magnitude, which is an essential step for the feasibility of building full-body human MPI scanners.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A stochastic approach to estimate the uncertainty of dose mapping caused by uncertainties in b-spline registration

Purpose: In fractionated radiation therapy, image guidance with daily tomographic imaging becomes more and more clinical routine. In principle, this allows for daily computation of the delivered dose and for accumulation of these daily dose distributions to determine the actually delivered total dose to the patient. However, uncertainties in the mapping of the images can translate into errors of the accumulated total dose, depending on the dose gradient. In this work, an approach to estimate the uncertainty of mapping between medical images is proposed that identifies areas bearing a significant risk of inaccurate dose accumulation. Methods: This method accounts for the geometric uncertainty of image registration and the heterogeneity of the dose distribution, which is to be mapped. Its performance is demonstrated in context of dose mapping based on b-spline registration. It is based on evaluation of the sensitivity of dose mapping to variations of the b-spline coefficients combined with evaluation of the sensitivity of the registration metric with respect to the variations of the coefficients. It was evaluated based on patient data that was deformed based on a breathing model, where the ground truth of the deformation, and hence the actual true dose mapping error, is known. Results: The proposed approach has the potential to distinguish areas of the image where dose mapping is likely to be accurate from other areas of the same image, where a larger uncertainty must be expected. Conclusions: An approach to identify areas where dose mapping is likely to be inaccurate was developed and implemented. This method was tested for dose mapping, but it may be applied in context of other mapping tasks as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sci-Thur PM - Colourful Interactions: Highlights 06: Patient-specific calibration of cone-beam computed tomographic (CBCT) image sets for on-line dose tracking and plan assessment

Purpose: To develop a radiotherapy dose tracking and plan evaluation technique using cone-beam computed tomography (CBCT) images. Methods: We developed a patient-specific method of calibrating CBCT image sets for dose calculation. The planning CT was first registered with the CBCT using deformable image registration (DIR). A scatter plot was generated between the CT numbers of the planning CT and CBCT for each slice. The CBCT calibration curve was obtained by least-square fitting of the data, and applied to each CBCT slice. The calibrated CBCT was then merged with original planning CT to extend the small field of view of CBCT. Finally, the treatment plan was copied to the merged CT for dose tracking and plan evaluation. The proposed patient-specific calibration method was also compared to two methods proposed in literature. To evaluate the accuracy of each technique, 15 head-and-neck patients requiring plan adaptation were arbitrarily selected from our institution. The original plan was calculated on each method’s data set, including a second planning CT acquired within 48 hours of the CBCT (serving as gold standard). Clinically relevant dose metrics and 3D gamma analysis of dose distributions were compared between the different techniques. Results: Compared to the gold standard of using planning CTs, the patient-specific CBCT calibration method was shown to provide promising results with gamma pass rates above 95% and average dose metric agreement within 2.5%. Conclusions: The patient-specific CBCT calibration method could potentially be used for on-line dose tracking and plan evaluation, without requiring a re-planning CT session.

60 APPLIED LIFE SCIENCES↗