Treatment of Irradiated Graphite from French Bugey Reactor - 13424

Beginning in 2009, in order to determine an alternative to direct disposal for decommissioned irradiated graphite from EDF's Bugey NPP, Studsvik and EDF began a test program to determine if graphite decontamination and destruction were practicable using Studsvik's thermal organic reduction (THOR) technology. The testing program focused primarily on the release of C-14, H-3, and Cl-36 and also monitored graphite mass loss. For said testing, a bench-scale steam reformer (BSSR) was constructed with the capability of flowing various compositions of gases at temperatures up to 1300 deg. C over uniformly sized particles of graphite for fixed amounts of time. The BSSR was followed by a condenser, thermal oxidizer, and NaOH bubbler system designed to capture H-3 and C-14. Also, in a separate series of testing, high concentration acid and peroxide solutions were used to soak the graphite and leach out and measure Cl-36. A series of gasification tests were performed to scope gas compositions and temperatures for graphite gasification using steam and oxygen. Results suggested higher temperature steam (1100 deg. C vs. 900 deg. C) yielded a practicable gasification rate but that lower temperature (900 deg. C) gasification was also a practicable treatment alternative if oxygen is fed into the process. A series of decontamination tests were performed to determine the release behavior of and extent to which C-14 and H-3 were released from graphite in a high temperature (900-1300 deg. C), low flow roasting gas environment. In general, testing determined that higher temperatures and longer roasting times were efficacious for releasing H-3 completely and the majority (80%) of C-14. Manipulating oxidizing and reducing gas environments was also found to limit graphite mass loss. A series of soaking tests was performed to measure the amount of Cl-36 in the samples of graphite before and after roasting in the BSSR. Similar to C-14 release, these soaking tests revealed that 70-80% Cl-36 is released during roasting tests. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High Efficiency Engine Technologies Program

Caterpillar's Product Development and Global Technology Division carried out a research program on waste heat recovery with support from DOE (Department of Energy) and the DOE National Energy Technology Laboratory. The objective of the program was to develop a new air management and exhaust energy recovery system that would demonstrate a minimum 10% improvement in thermal efficiency over a base heavy-duty on-highway diesel truck engine. The base engine for this program was a 2007 C15 15.2L series-turbocharged on-highway truck engine with a LPL (low-pressure loop) exhaust recirculation system. The focus of the program was on the development of high efficiency turbomachinery and a high efficiency turbocompound waste heat recovery system. The focus of each area of development was as follows: (1) For turbine stages, the focus was on investigation and development of technologies that would improve on-engine exhaust energy utilization compared to the conventional radial turbines in widespread use today. (2) For compressor stages, the focus was on investigating compressor wheel design parameters beyond the range typically utilized in production, to determine the potential efficiency benefits thereof. (3) For turbocompound, the focus was on the development of a robust bearing system that would provide higher bearing efficiencies compared to systems used in turbocompound power turbines in production. None of the turbocharger technologies investigated involved addition of moving parts, actuators, or exotic materials, thereby increasing the likelihood of a favorable cost-value tradeoff for each technology. And the turbocompound system requires less hardware addition than competing bottoming cycle technologies, making it a more attractive solution from a cost and packaging standpoint. Main outcomes of the program are as follows: (1) Two turbine technologies that demonstrated up to 6% improvement in turbine efficiency on gas stand and 1-3% improvement in thermal efficiency in on-engine testing. (2) A compressor technology that demonstrated 1.5% improvement in compressor efficiency on gas stand compared to production available compressors. (3) A power turbine with high efficiency bearing system that demonstrated excellent rotordynamic stability throughout the required speed range, up to 60,000 rpm. (4) A predicted improvement (using engine simulation) in engine thermal efficiency of 7% at the peak torque design point, when combining the technologies developed in this program.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design, fabrication and test of prototype furnace for continuous growth of wide silicon ribbon

A program having the overall objective of growing wide, thin silicon dendritic web crystals quasi-continuously from a semi-automated facility is discussed. The design considerations and fabrication of the facility as well as the test and operation phase are covered; detailed engineering drawings are included as an appendix. During the test and operation phase of the program, more than eighty growth runs and numerous thermal test runs were performed. At the conclusion of the program, 2.4 cm wide web was being grown at thicknesses of 100 to 300 micrometers. As expected, the thickness and growth rate are closely related. Solar cells made from this material were tested at NASA-Lewis and found to have conversion efficiencies comparable to devices fabricated from Czochralski material.

Duncan, C. S.↗

Keynote address

The Space Shuttle test program is described. Consideration is given to thermal vacuum testing, static testing, ground vibration testing, high temperature testing, propulsion system testing, etc. Emphasis is placed on the Shuttle test philosophy and how it differs from that of past programs.

Yardley, J. F.↗

Space Shuttle Orbiter leading edge structural subsystem thermal performance

An extensive qualification test program and the STS-1 flight of the Space Shuttle Orbiter have provided the data necessary to verify the performance of the Orbiter thermal protection system. The reinforced carbon-carbon leading edge structural subsystem is used on areas of the orbiter where temperatures exceed 2300 F. The subsystem consists of the ROC nose cap and wing leading edge panels, metallic attachments, internal insulation, and interface tiles. Thermal response data from the qualification tests and the STS-1 flight, postflight inspection, and analytical predictions support the conclusion that the thermal performance of the subsystem verified the design.

Curry, D. M.↗

Space tug thermal control follow-on

The Space Tug Thermal Control Follow-On program was conducted to further explore some of the thermal control concepts proposed for use in space tug in a breadboard test program. The objectives were to demonstrate the thermal control capabilities of a louver/battery configuration and a thermal conditioning panel/heat pipe radiator configuration. An additional objective was added to model the header pipe and radiator of the second test and correlate the analysis with the test results. These three objectives were achieved and are discussed within this report.

Ward, T. L.↗

Radiative, actively cooled panel tests results

The radiative, actively cooled panel designed to withstand a uniform incident heat flux of 136 kW/sq m to a 444 K surface temperature was evaluated. The test program consisted of preliminary static thermal mechanical loading and aerothermal flow tests. Test results are briefly discussed.

Shore, C. P.↗

Summary of results from the testing of three prototype thermal bus systems for Space Station Freedom

Three Space Station Freedom (SSF) prototype two-phase thermal bus systems, utilizing ammonia as the working fluid, underwent extensive evaluation during 1988 and 1989. All three test articles were exercised in a similar ambient test program to characterize performance under simulated SSF operating conditions. Additionally, thermal buses were integrated with heat pipe radiators and tested in a thermal vacuum (T/V) environment. Testing has shown that two-phase thermal bus performance can be generally bound in an ambient test program; however, integrated T/V testing with heat pipe radiators similar to those that will be used on SSF is required to fully characterize system performance.

Brady, T. K.↗

Results of thermal vacuum tests for the PASP+ flight modules

The PASP PLUS (Photovoltaic Array Space Power Plus Diagnostics) program is a photovoltaic experiment which will be flown on the Air Force satellite APEX (Advanced Photovoltaic And Electronic Experiment). APEX will be launched with a Pegasus during the summer of 1993. There are two other small experiments on APEX but PASP+ is the largest, uses the most power, and accounts for over 90 percent of the data requirements. The orbit is elliptical with apogee and perigee of 1050 and 190 nautical miles respectively. The inclination is 70 deg. The two main objectives of PASP+ are to determine the interactions between high voltage arrays and the space plasma environment and to determine the radiation damage characteristics of several newer types of solar cells. In order to determine the interactions with the space plasma, several of the individual cell strings will be biased to voltages up to plus or minus 500 V, and leakage currents and arcing rates will be measured. The radiation degradation characteristics will be determined by the continuous monitoring of I-V data for all of the cell strings. As part of an overall testing program, the PASP+ panels and controller were put through a thermal vacuum test in order to check the thermal analysis, obtain temperature coefficients for the individual modules, and have an end-to-end test of the entire PASP+ experiment. This thermal vacuum test is described briefly and the results obtained during that testing are discussed.

Curtis, Henry↗

P78-2 (SCATHA) satellite thermal balance test, a laboratory test

Space simulation test programs can be carried out with a high probability of being troublefree with a competent staff, a well-maintained test facility and attention to interfaces; however, full-up thermal balance tests using the solar simulator, temperature control of infrared sources, the gimbal, a large number of thermocouples, and other requirements for a high fidelity thermal balance are still a challenge. The P78-2 (Scatha) satellite was successfully tested with one interruption and a four-day abbreviated retest to verify a modification. This was accomplished in spite of the new test crew, a facility beset with several operational problems, and marginal interface control. These problems were addressed with very good results. Subsequent tests have been highly successful.

Parrish, R. P., Jr.↗

Thermal Management Technology Status

The thermal control requirements of a large space station are considered. Motivations for advanced thermal technology are discussed. Two test programs, designed to evaluate the analytical and theoretical basis from which thermal technology directions are determined, are described.

Parish, R. C.↗

Analytical flow/thermal modeling of combustion gas flows in Redesigned Solid Rocket Motor test joints

A one-dimensional analytical tool, TOPAZ (Transient One-dimensional Pipe flow AnalyZer), was used to model the flow characteristics of hot combustion gases through Redesigned Solid Rocket Motor (RSRM) joints and to compute the resultant material surface temperatures and o-ring seal erosion of the joints. The capabilities of the analytical tool were validated with test data during the Seventy Pound Charge (SPC) motor test program. The predicted RSRM joint thermal response to ignition transients was compared with test data for full-scale motor tests. The one-dimensional analyzer is found to be an effective tool for simulating combustion gas flows in RSRM joints and for predicting flow and thermal properties.

Woods, G. H.↗

Twenty Years On!: Updating the IEA BESTEST Building Thermal Fabric Test Cases for ASHRAE Standard 140

ANSI/ASHRAE Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs applies the IEA BESTEST building thermal fabric test cases and example simulation results originally published in 1995. These software accuracy test cases and their example simulation results, which comprise the first test suite adapted for the initial 2001 version of Standard 140, are approaching their 20th anniversary. In response to the evolution of the state of the art in building thermal fabric modeling since the test cases and example simulation results were developed, work is commencing to update the normative test specification and the informative example results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Results of shuttle EMU thermal vacuum tests incorporating an infrared imaging camera data acquisition system

Manned tests in Chamber B at NASA JSC were conducted in May and June of 1990 to better quantify the Space Shuttle Extravehicular Mobility Unit's (EMU) thermal performance in the cold environmental extremes of space. Use of an infrared imaging camera with real-time video monitoring of the output significantly added to the scope, quality and interpretation of the test conduct and data acquisition. Results of this test program have been effective in the thermal certification of a new insulation configuration and the '5000 Series' glove. In addition, the acceptable thermal performance of flight garments with visually deteriorated insulation was successfully demonstrated, thereby saving significant inspection and garment replacement cost. This test program also established a new method for collecting data vital to improving crew thermal comfort in a cold environment.

Anderson, James E.↗

Twenty Years On!: Updating the IEA BESTEST Building Thermal Fabric Test Cases for ASHRAE Standard 140: Preprint

ANSI/ASHRAE Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs applies the IEA BESTEST building thermal fabric test cases and example simulation results originally published in 1995. These software accuracy test cases and their example simulation results, which comprise the first test suite adapted for the initial 2001 version of Standard 140, are approaching their 20th anniversary. In response to the evolution of the state of the art in building thermal fabric modeling since the test cases and example simulation results were developed, work is commencing to update the normative test specification and the informative example results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Shuttle antenna radome technology test program. Volume 2: Development of S-band antenna interface design

The effects of the Thermal Protection Subsystem (TPS) contamination on the space shuttle orbiter S band quad antenna due to multiple mission buildup are discussed. A test fixture was designed, fabricated and exposed to ten cycles of simulated ground and flight environments. Radiation pattern and impedance tests were performed to measure the effects of the contaminates. The degradation in antenna performance was attributed to the silicone waterproofing in the TPS tiles rather than exposure to the contaminating sources used in the test program. Validation of the accuracy of an analytical thermal model is discussed. Thermal vacuum tests with a test fixture and a representative S band quad antenna were conducted to evaluate the predictions of the analytical thermal model for two orbital heating conditions and entry from each orbit. The results show that the accuracy of predicting the test fixture thermal responses is largely dependent on the ability to define the boundary and ambient conditions. When the test conditions were accurately included in the analytical model, the predictions were in excellent agreement with measurements.

Kuhlman, E. A.↗